Loading…
Loading…
Tender Value
₹3.4 Cr
EMD Value
₹6.9 L
Closing Date
20 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; whereV= Advertised value of the tender in crores of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Annexure-VIB of GCC April-2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:a)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, orb)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, orc)One similar work costing not less than the amount equal to 60% of advertised value of the tender.(i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:a)Three similar works costing not less than the amount equal to 30% of advertised value of each component of tender, orb)Two similar works costing not less than the amount equal to 40% of advertised value of each component of tender, orc)One similar work costing not less than the amount equal to 60% of advertised value of each component of tender.Note for (B)(i): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components.
4 conditions · 2 needing a document upload
As per Tender Document.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
As per Tender Document.
Supply, Installation, Testing & commissioning of Indoor and outdoor signalling work for alteration in Electronic Interlocking (EI) system at Khandwa station of Bhusawal Division of Central Railway for provision of Absolute block working between Khandwa & Mordar in connection of GC between Khandwa-Akola section of South Central Railway.
BSL-SnT-C-S-2026-27-02
BSL-SnT-C-S-2026-27-02
Open
Works - General
11 Months
Jalgaon, Maharashtra
₹0
₹6.9 L
20 Aug 2026
29 Jul 2026
6 Aug 2026
317 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 99,38,769.48 | ||
| — | 1.00 | — | — | ||
| Supply of as made documents (Manuals for Installation, Testing, and maintenance of the system) (One set consists of 6 set of following drawings per station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians/Jr. Engineers. (Installation and maintenance level ) (ii) Functioning and system overview (Higher Management Level) (iii) Completion documents as per special conditions of contract. (iv) Design & supply of circuits and plans to suit layout given in the signaling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plan and wiring diagram shall be prepared on AutoCAD Drawing and supplied with C D . This will include supply of Control-cum-Indication Panel/VDU diagram, Square sheet, wiring diagrams (Application Logic and Interface circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power supply Distribution / Power Equipment arrangement (with program switch) Diagram, Auto change over diagram (if supplied by the contractor), and all other relevant drawings.NOTE : The contractor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure that each sheet has a block for signature of Railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of comments by Railways, the Contractor will make copies of the approved documents and return the approved documents to Railways. The contractor will then make necessary correction to Application Logic Software duly incorporating Railways' alterations/corrections/comments, if any. After complete testing/ commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways for approval. Along with the completion application logic, difference report (showing addition & deletion in different colors) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of duly approved completion tracings will be submitted to Railways. | — | — | — | 1,58,869.3 | |
| — | 2.00 | — | — | ||
| Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations. | — | — | — | 61,374.16 | |
| — | 1.00 | — | — | ||
| Supply of PVC Indoor cable 1x60x0.6mm dia color coding of insulation of inner core shall be in six color viz Blue, Red, Grey, Green,Brown & Black conforming to IRS 76/89 (Amd.3) or latest. | — | — | — | 3,07,307.4 | |
| — | 1.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x2.5 Sq.mm (50 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 46,427.1 | |
| — | 1.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 1,40,681.96 | |
| — | 2.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 4,17,984.32 | |
| — | 1.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | — | — | — | 3,29,990.54 | |
| — | 5.00 | — | — | ||
| Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. | — | — | — | 33,069.5 | |
| — | 48.00 | — | — | ||
| Supply of low maintenance Lead Acid secondary cells 2V 80AH as per spec. IRS 88/2004 version 1.0 with latest amendments. | — | — | — | 93,172.8 | |
| — | 10.00 | — | — | ||
| Supply of QNA1-K AC immunized relay, 8F-8B, 24 VDC along with plug, retaining clip and connectors conforming to BRS:931A & RDSO letter no STS/E/Relays/UEA/PI dated 30.05.97 Annexure-II IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | — | — | — | 41,772 | |
| — | 10.00 | — | — | ||
| Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | — | — | — | 39,636.2 | |
| — | 10.00 | — | — | ||
| Supply of QTA2 AC immunized track relay, 9 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) | — | — | — | 38,243.8 | |
| — | 5.00 | — | — | ||
| Supply of QBAT track Relay, AC immunized, 2F-2B, contacts, 9 ohms. Complete with plug, board, retaining clip and connectors as per RDSO/SPN/84 Ver. 2.0 with Amendment No.1 or latest. | — | — | — | 32,632.9 | |
| — | 10.00 | — | — | ||
| Supply of QBCA1 AC immunized relay, 2FHD 4F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY. And RS S46/74 with Amendment No.1 & firms specification. | — | — | — | 47,931.6 | |
| — | 10.00 | — | — | ||
| Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A. | — | — | — | 47,270.8 | |
| — | 5.00 | — | — | ||
| Supply of Key Lock Relay working on 24V DC, AC immunized with different ward combinations (Three ward plates to be supplied with each relay). RDSO/SPN/219/2016 Version 1.0 with Amendment No.01. | — | — | — | 35,748.1 | |
| — | 2.00 | — | — | ||
| Supply of Block filter unit as per IRS:S-68/89 and Block bell equipment as per IRS:TC- 44/88 (Amd. 1). | — | — | — | 45,052.4 | |
| — | 2.00 | — | — | ||
| Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Micowave Radio. | — | — | — | 70,856.64 | |
| — | 2.00 | — | — | ||
| Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 km distance. | — | — | — | 1,45,491.64 | |
| — | 50.00 | — | — | ||
| Supply of PPTC Fuse GP 60-400 UL-94 certification (12V/4A) TF, TR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | — | — | — | 413 | |
| — | 50.00 | — | — | ||
| Supply of PPTC Fuse GP 30-100 (24V/1.4A) TPR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | — | — | — | 413 | |
| — | 50.00 | — | — | ||
| Supply of PPTC Fuse GP 250-185 UL-94 certification (24V/4A)110V AC for track chargers. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | — | — | — | 413 | |
| — | 40.00 | — | — | ||
| Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. | — | — | — | 50,881.6 | |
| — | 25.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs) | — | — | — | 1,681.5 | |
| — | 5.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. | — | — | — | 1,36,567.3 | |
| — | 2.00 | — | — | ||
| Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. | — | — | — | 14,110.44 | |
| — | 5.00 | — | — | ||
| Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. | — | — | — | 47,902.1 | |
| — | 4.00 | — | — | ||
| Supply of Shunt signal post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.) | — | — | — | 12,508 | |
| — | 7.00 | — | — | ||
| Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. | — | — | — | 65,617.44 | |
| — | 4.00 | — | — | ||
| Supply of Cast Iron Shunt signal surface base 80 mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, as per RDSO Drg. No.SA- 23156/ Drg. No.RST/11413 as per extant C. Rly practice. | — | — | — | 8,269.44 | |
| — | 11.00 | — | — | ||
| Supply of Signal No.Plates as per Drg No RST-11393/ SK-842 | — | — | — | 5,802.06 | |
| — | 3.00 | — | — | ||
| OFF set bracket 5-1/2" to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes. | — | — | — | 2,906.34 | |
| — | 3.00 | — | — | ||
| OFF set bracket 3-1/2' for signals & Routes. Drawing No.SA23840(Adv) Alt-2 as per extent C.Rly practice. | — | — | — | 14,616.66 | |
| — | 4.00 | — | — | ||
| Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment. | — | — | — | 2,246.72 | |
| — | 4.00 | — | — | ||
| Supply of Stop Board / IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice. | — | — | — | 13,041.36 | |
| — | 2.00 | — | — | ||
| Supply of different warning Board as per Goods warning Board (SK-784) RDSO Drg No. SA 2380 (Adv), SA 2370/M-, Block section limit Board RDSO Drg No. SA 2373 - Paint and retroreflective arrangement as per Railways drawing. | — | — | — | 6,596.2 | |
| — | 10.00 | — | — | ||
| Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. | — | — | — | 2,891 | |
| — | 5.00 | — | — | ||
| Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost | — | — | — | 1,52,361.6 | |
| — | 5.00 | — | — | ||
| Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost | — | — | — | 1,57,164.2 | |
| — | 4.00 | — | — | ||
| Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps. | — | — | — | 55,370.32 | |
| — | 2.00 | — | — | ||
| Supply of 1 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | — | — | — | 69,339.16 | |
| — | 2.00 | — | — | ||
| Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | — | — | — | 86,066.84 | |
| — | 1.00 | — | — | ||
| Supply of 3 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | — | — | — | 45,632.96 | |
| — | 2.00 | — | — | ||
| Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | — | — | — | 16,883.44 | |
| — | 20.00 | — | — | ||
| Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995. | — | — | — | 1,09,716.4 | |
| — | 3000.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. | — | — | — | 2,30,100 | |
| — | 100.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. | — | — | — | 16,992 | |
| — | 100.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity | — | — | — | 7,316 | |
| — | 15.00 | — | — | ||
| Supply of Tik-tak, piano type switches, 5 A (as per IS Specification). | — | — | — | 531 | |
| — | 15.00 | — | — | ||
| Supply of three pole plug and socket 5 Amp (as per IS Specification). | — | — | — | 3,628.5 | |
| — | 15.00 | — | — | ||
| Supply of Lamp 110V / 24W, 2 pin for Loc. | — | — | — | 354 | |
| — | 15.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration. | — | — | — | 2,52,260.4 | |
| — | 5.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration. | — | — | — | 66,593.3 | |
| — | 20.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815 | — | — | — | 22,443.6 | |
| — | 3.00 | — | — | ||
| Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. | — | — | — | 4,20,003.3 | |
| — | 25.00 | — | — | ||
| Supply of Track Lead junction Boxes as per C.Rly Drg.No.RST 11509 made from fiber glass alongwith terminal blocks. | — | — | — | 25,901 | |
| — | 5.00 | — | — | ||
| Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3 ) with latest amendments. | — | — | — | 18,284.1 | |
| — | 5.00 | — | — | ||
| Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments ( with phenolic moulded base). | — | — | — | 6,425.1 | |
| — | 5.00 | — | — | ||
| Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 11,805.9 | |
| — | 2000.00 | — | — | ||
| Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. | — | — | — | 4,720 | |
| — | 1000.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used. | — | — | — | 54,280 | |
| — | 50.00 | — | — | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13-62 | — | — | — | 4,425 | |
| — | 4.00 | — | — | ||
| Supply of single section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or Latest.Each set consist of following:-a) High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos along with 10 mtr cable-2 sets),b)Track side digital axle counter unit.-2 nos.c) 24V 6F/4B, 1000 ohm "Q" type relay Box duly wired - 2 Nos.d) Clamp with detector plates and hardware etc-4 Nose) Reset Box 2 Nos ii) Mushroom/Location Box suitable for housing Track side equipment (2 Nos.)2) Transportation, Installation testing & commissioning:- Transportation, Installation testing & commissioning of equipment field training (one man day per set) at site or as desired by site Engineer. These includes:-a) Foundation & erection of Track side Equipment i.e. Mushroom/ Location Box (If required). This includes supply of all associated materials.,b) Individual Earthing of all detection Point for the OEM recommended earth value certified by OEM site engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec.no: RDSO/SPN/197/2008 or latest. Resetting equipment to the connected to the EI Ring earth.c) Installation to be carried out by OEM certified Engineer.3) Tool Kit consisting of :-a) Digital True RMS multi meter of suitable make for above Digital Axle counter system with probe set- 1nob) Train Simulator (High frequency)-1 noc) Extender Card - 1 nod) Dummy wheel-1 noe) Different type of spanners suitable for above Digital Axle counter - 1 setf) Torque wrenches suitable for the aboe-1 nog) Screw driver set suitable for the above - 1 set.h) Carrying Bag for Tools - 1 noi) 6 nos Electrostatic Discharge Wrist Band for cards/ modules protection. | — | — | — | 18,58,839.84 | |
| — | 30.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. | — | — | — | 32,143.2 | |
| — | 30.00 | — | — | ||
| Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. | — | — | — | 10,195.2 | |
| — | 4500.00 | — | — | ||
| Supply of RCC Trunking with capping. Size 250mm x 200mm Drg.No.RST/C/291/A | — | — | — | 33,98,400 | |
| — | 1000.00 | — | — | ||
| Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. | — | — | — | 1,18,000 | |
| — | 5.00 | — | — | ||
| Supply of DIN Channel for the terminals 1 Mtrs each | — | — | — | 1,103.3 | |
| — | 1000.00 | — | — | ||
| Supply of End plates for modular terminal block | — | — | — | 23,600 | |
| — | 50.00 | — | — | ||
| Supply of End Clamp for modular terminal block | — | — | — | 885 | |
| — | 5.00 | — | — | ||
| Supply of Thermo-Shrink cable joining kit (Reinforced) TSF-2 type generally confirming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.:CR/SPN/TC/57 (A)/2015 Dt: 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit (Table-B) for armour continuity. | — | — | — | 15,989 | |
| — | 10.00 | — | — | ||
| SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. | — | — | — | 28,166.6 | |
| — | 5.00 | — | — | ||
| Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. | — | — | — | 92,458.9 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
KHANDWAMORDARTentativeSIP_compressed1.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo.1.pdf
ATTACHMENT
GCCCorrectionSlipNo.2.pdf
ATTACHMENT
GCCCorrectionSlipNo.3.pdf
ATTACHMENT
GCCCorrectionSlipNo.4.pdf
ATTACHMENT
GCCCorrectionSlipNo.5.pdf
ATTACHMENT
GCCCorrectionSlipNo.6.pdf
ATTACHMENT
GCCCorrectionSlipNo.7.pdf
ATTACHMENT
GCCCorrectionSlipNo.8.pdf
ATTACHMENT
GCCCorrectionSlipNo.9.pdf
ATTACHMENT
GCCCorrectionSlipNo.10.pdf
ATTACHMENT
GCCCorrectionSlipNo.11.pdf
ATTACHMENT
KAVACHpolicyLetter.pdf
ATTACHMENT
ExemptionfromPVC.pdf
ATTACHMENT
ListofSAFETYCRITICALSIGNALITEMSMANDATORYINSPECTEDBYRDSO.pdf
ATTACHMENT
CableVicinitycircular09-2023.pdf
ATTACHMENT
Depthofcableletter.pdf
ATTACHMENT
SpecialIntructionGuidelinesissuedbyCAOCOffice.pdf
ATTACHMENT
KNWTenderDocumentPtII.pdf
ATTACHMENT
KNWTenderDocumentPtI_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .