Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAdmitted-Finance 57 B FEEDER ROAD GROUND FLOOR 57 B FEEDER ROAD BARRACKPORE NORTH 24 PARGANAS WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹36.1 L | L1 | Admitted-Finance |
| 2 | L2₹41.4 L+₹5.3 L (14.7%)Admitted-Finance | ₹41.4 L+₹5.3 L (14.7%) | L2 | Admitted-Finance |
| 3 | L3₹45.5 L+₹9.3 L (25.8%)Admitted-Finance 116 SHANTINAGAR ROAD BHADRAKALI UTTARPARA HOOGHLY WEST BENGAL 712232 | HOOGHLY | WEST BENGAL | 712232 | ₹45.5 L+₹9.3 L (25.8%) | L3 | Admitted-Finance |
| 4 | L4₹49.9 L+₹13.8 L (38.2%)Admitted-Finance 217 TILJALA ROAD TILJALA ROAD KOLKATA TILJALA ROAD KOLKATA WEST BENGAL 700046 KOLKATA WEST BENGAL 700046 | KOLKATA | WEST BENGAL | 700046 | ₹49.9 L+₹13.8 L (38.2%) | L4 | Admitted-Finance |
| 5 | L5₹54.0 L+₹17.8 L (49.4%)Admitted-Finance | ₹54.0 L+₹17.8 L (49.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Lyric International L6 | AIR Q SOLUTIONS L3 | M/s Auto-Tech Projects Pvt. Ltd L5 | AIR COOLING SOLUTIONS L4 | TRANSTECH L2 | ALPHA GAMMA AIR SOLUTIONS PVT. LTD. L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minimum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407.The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 asbelow and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) | 63 | HP | 23,795 ₹14,99,085 | 31,500 ₹19,84,500 | 22,652 ₹14,27,076 | 20,484.15 ₹12,90,501.45 Lowest | 28,280 ₹17,81,640 | 30,000 ₹18,90,000 |
| 2.00Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price. | |||||||||
| 2.01 | Hi-Wall Type Indoor Unit - Capacity - 0.8TR | 2 | Nos. | 29,000 ₹58,000 | 36,000 ₹72,000 | 23,642 ₹47,284 | 22,965 ₹45,930 | 20,584 ₹41,168 | 18,000 ₹36,000 Lowest |
| 2.02 | Hi-Wall Type Indoor Unit - Capacity - 1.0TR | 2 | Nos. | 29,500 ₹59,000 | 38,000 ₹76,000 | 25,331 ₹50,662 | 23,504 ₹47,008 | 22,117 ₹44,234 | 19,000 ₹38,000 Lowest |
| 2.03 | Hi-Wall Type Indoor Unit - Capacity - 1.3TR | 2 | Nos. | 31,900 ₹63,800 | 39,000 ₹78,000 | 29,047 ₹58,094 | 23,975.5 ₹47,951 | 25,486 ₹50,972 | 20,000 ₹40,000 Lowest |
| 2.04 | Hi-Wall Type Indoor Unit - Capacity - 1.5TR | 13 | Nos. | 32,500 ₹4,22,500 | 41,000 ₹5,33,000 | 29,722 ₹3,86,386 | 27,278 ₹3,54,614 | 26,099 ₹3,39,287 | 21,000 ₹2,73,000 Lowest |
| 2.05 | Hi-Wall Type Indoor Unit - Capacity - 1.7TR | 9 | Nos. | 33,500 ₹3,01,500 | 42,000 ₹3,78,000 | 32,695 ₹2,94,255 | 28,019.5 ₹2,52,175.5 | 28,794 ₹2,59,146 | 22,000 ₹1,98,000 Lowest |
| 2.06 | Hi-Wall Type Indoor Unit - Capacity - 2.0TR | 3 | Nos. | 37,900 ₹1,13,700 | 45,000 ₹1,35,000 | 32,695 ₹98,085 | 28,019.5 ₹84,058.5 | 28,794 ₹86,382 | 22,500 ₹67,500 Lowest |
| 2.07 | Hi-Wall Type Indoor Unit - Capacity - 2.5TR | 6 | Nos. | 42,900 ₹2,57,400 | 63,500 ₹3,81,000 | 36,883 ₹2,21,298 | 51,710 ₹3,10,260 | 32,592 ₹1,95,552 | 25,000 ₹1,50,000 Lowest |
| 3.00VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION | |||||||||
Tender Value
₹41.9 L
EMD Value
₹83,870
Closing Date
19 Mar 2026, 12:00 pmClosed
Superintending Engineer (E and M)
RAC Section, IIT Kharagpur
Supply, Installation, Testing and Commissioning of Air conditioning work for Rubber Technology Research Lab,RTC of IIT Kharagpur.
2026_IITKG_900208_1
IITKGP/RAC/VRF/RTC/2026
Open Tender
Miscellaneous Works
Item Rate
100 days
Rubber Technology Resarch Lab
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹83,870
Meeting Room of SE (E and M)
17 Apr 2026
25 Feb 2026
20 Mar 2026
25 Feb 2026
19 Mar 2026
25 Feb 2026
5 Mar 2026
Supply, Installation, Testing & Commissioning of Air Cooled type outdoor units of VRF system having hermetically sealed inverter scroll compressor, condenser coil fabricated from Seamless Copper tube & Plate type Al. Fins of Multi Row, Axial Flow, top discharge throw condenser fan, Condenser fan - motor unit, all system controls-safety. The system should have flexibility to handle total 280 Rmt of ref. piping. ODU shall be placed on structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration. The system shall have minimum COP of 3.7 at ARI condition as per CPWD guidelines. Each Outdoor units with High Pressure switch, Fan driver overload protector, Over current relay, Inverter Overload Protector & Fusible Plug. The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP protection will be suitable for outdoor installation. The VRF System shall have green ref. gas only- R410A/ R407.The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 asbelow and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity >40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building)
Indoor Units Supply, Installation, Testing & Commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil, outer cabinet, drain pan mechanism insulation, pipe connections, clamp metal, washer fixing plate, sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting, fresh air intake connector for cassettes etc. of various capacities as per specifications. Power cabling (3mtr from unit) with conduit from power socket & plug top to indoor is inclusive of price.
Hi-Wall Type Indoor Unit - Capacity - 0.8TR
Hi-Wall Type Indoor Unit - Capacity - 1.0TR
Hi-Wall Type Indoor Unit - Capacity - 1.3TR
Hi-Wall Type Indoor Unit - Capacity - 1.5TR
Hi-Wall Type Indoor Unit - Capacity - 1.7TR
Hi-Wall Type Indoor Unit - Capacity - 2.0TR
Hi-Wall Type Indoor Unit - Capacity - 2.5TR
VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS WITH PRECAST INSULATION
REMOTE CONTROLLER
Supply, installation, testing & commissioning of Cordlesss remotes for VRF indoor units
SITC of VRF Refrigerant Piping: Supply, installation, testing & commissioning of Seamless heavy gauge Copper piping of following size duly insulated with 13 mm/ 19mm thk. Nitrile Rubber Insulation covered with aluminium foil ( As per Specified with K Value of 0.027-0.029 K Cal/Hr.M Deg C at 0-16 Deg C) . Refrigeration piping will have to be taken in the piping rack / Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. The exposed refrigerent insulated piping shall be covered with UV Resistance canvass coating.
34.93 mm O.D.(with 19 mm insulation )
31.8 mm O.D.(with 19 mm insulation )
28.6 mm O.D.(with 19 mm insulation )
25.4 mm O.D..(with 19 mm insulation )
22.2 mm O.D..(with 19 mm insulation )
19.05 mm O.D..(with 19 mm insulation )
15.88 mm O.D..(with 19 mm insulation )
12.7 mm O.D..(with 19 mm insulation )
22.2 mm O.D..(with 13 mm insulation )
19.1 mm O.D..(with 13 mm insulation )
15.9 mm O.D..(with 13 mm insulation )
12.7 mm O.D.(with 13mm insulation )
9.52 mm O.D.(with 13mm insulation )
6.35 mm O.D.(with 13mm insulation )
Supply, Installation and Testing of rigid PVC Drain Piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
25 mm dia
SITC of GI perforated Cable Tray for the refrigerant pipe hanging & Covering
Supply & fixing of control cum transmission wiring of Copper conductor Shielded cable along with PVC conduit / casing for looping between indoor & outdoor VRF system.
2 C X 1.5 Sq. mm (Communication cable)
3 C X 1.5 Sq. mm - PVC insulated & PVC sheathed cable for IDU power connection
Supply, installation, testing & commissioning of require size copper conductor steel armoured power cable with termination to individual Outdoor units.(From Power Panel to VRF ODU)
Civil foundation of VRF ODU
Making wall opening for passage in the wall/glass for ref & drain pipes and cables and making good of the same for all the indoor/ outdoor units.
Decorative Pelmets of required size for fixing of IDUs on wall with 16 mm thich anti termite laminated board.
Supply, installation, testing and commissioning of Higher Efficient models of NON-INVERTER TYPE SPLIT AC, Three STAR RATING OF BEE (Bureau of Energy Efficiency) AIR CONDITIONERS of 1.5 TR capacity confirming to latest Indian Standards and suitable for operation on 230 Volts + 10 %, single Phase, 50 Hz AC supply with rotary compressor, Refrigerant and capable to perform cooling, dehumidifying, Air Circulating, auto swing with remote control with Cool/Fan/Dry/Auto mode with suitable thermostat. The unit should have LED Display. (Preferred make: Mitsubishi Electric/ Mitsubishi heavy/ O general/ Bluestar/ Voltas/ Daikin/ Hitachi/ Carrier/ LG)
Comprehensive AMC of the VRF system for four years after DLP.
Comprehensive AMC 1st Year after DLP
Comprehensive AMC 2nd Year after DLP
Comprehensive AMC 3rd Year after DLP
Comprehensive AMC 4th Year after DLP
stage.html
html • 0.03 MB
techsummary_946207.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.38 MB
BOQ_946207.xls
BOQ • 0.41 MB
Corrigendum1.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .