Reliability improvement work of track circuit by provision of MSDAC in parallel of existing DCTC at NYN,PCOI and SFG stations of Prayagraj Division.
PRYJ-Sig-040-2025-26~NCR
PRYJ-Sig-040-2025-26
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹11.0 L
9 Mar 2026
7 Feb 2026
23 Feb 2026
"Multi section Digital Axle Counter (MSDAC) supply,design, installation, testing and commissioning of multi section digital axle counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version 3 with Latest amendments or latest. Suitable for commissioning of yard/Auto Section/dual detection (DCTC/AFTC with MSDAC). MSDAC should have facility to reset track sections. Design of axle counter circuit indoor installation testing and commissioning of multi section digital axle counter (per unit), supply of essential 10% spares covering all types of cards, wheel sensors for MSDAC. Supply of Diagnostic system for Remote diagnostics Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, gloves and multimeter fluke 115 (1 Nos. per 14 DP). NOTE: 1. If any housing is required to keep outdoor 1 equipment, it has to be supplied with the equipment with no extra cost. 2. Maintenance free earthing (supply and installation) for track device/mushroom housing etc. to be done by the contractor if required by system design. No extra cost/ payment will be made by this Railway: 3. Automatic resetting facilities through hardware/software for auto resetting to be provided by contractor by his own materials for this no extra cost/payment will be made by Railways. 4. MSDAC system networking to be done with central control room. Required hardware PC/ network F equipment to be provided by the contractor, no extra cost/payment will be made for this by Railway. El Channel/media will be provided by Railway for this purpose from nearest Railway station. 5. All other Hardware like TPR, Extra card to make dual DP, Modem, ethernet switches etc. if required for commissioning and final track section pick up will be supplied by contractor, no extra payment will be made by this Railway. 6 Separate evaluator for UP and Down line to be provided at Station/RH as decided by Railway site engineer. For the communication between evaluator to evaluator (RH to Station) Quad/ OFC Link (dark fiber) will be provided by Railway. Any other Networking equipment if required will be supplied by contractor at no extra cost. 7. Manual resetting through reset box and LV box at station to be provided as per requirement. "Inspection by-RDSO
Supply of Tools Kit for Digital Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec.RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012, Ver.3 or latest respectively). The tool kit shall be minimum equipped with the following equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 no (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 no. (vi) Marking Jig - 1 no. (vii) Adapter card - 1 no. (viii) Extended wired socket to inetrface with diagnostic plug - 1 no. (viii) Selector switch on panel base - 1 no. (ix) DAC EC card puller etc."Inspection by-RITES"
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consists of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) 3 Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable."Inspection by-RDSO"
Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00-meter-long high tensile low carbon steel circular rods molecularly bonded with 4 copper and outer surface (minimum copper bonding thickness of 250 microns to made irement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Spec. No. RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are: (i) SDO/RDSO/E&B/001 for typical installation of Earth. (ii)SDO/RDSO/E&B/002 for typical bonding and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements. "Inspection by-Consignee"
"Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, 5 suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified." Inspection by-RITES
Supply & installation of RFID based Electronic cable route marker for S&T/Power cable, which can be buried at a depth range 1.5 meter. Make -Stanlay/3M or similar. This Item Includes the GPS marking of RFID Marker with the help of RFID Locator or App based system."Inspection by-RITES"
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of loose soil. This work 7 includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done. "Inspection by- Consignee"
"Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of 8 cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes."Inspection by-Consignee" "
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer."Inspection by-Consignee"
Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer.The GI pipe is to be filled with chattered 10 compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest."Inspection by-Consignee"
"Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of 11 minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable." Inspection by-Consignee
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. Th e bore shall be done at the depth of minimum 1400 mm from the ground level. Th e 12 ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only aft er DWC/HDPE/GI pipe is laid in the bore."Inspection by-Consignee"
"Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, 13 with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys." Inspection by-RITES
"Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or latest, 14 with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys." Inspection by-Consignee
Supply of Disconnect Terminal block for four conductors with screwing cage/clamp type, 15 sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks."Inspection by-RDSO"
"Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. "Inspection by-RDSO" "
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full) "Inspection by-Consignee"
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half) "Inspection by-Consignee"
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full ( ( As per drg no. AGC/FULL LOC/ 2023/01 issued vide NCR letter no. NCR/S&T/8005/TYPICAL/PT-4 19 Dt.14.08.2025 or latest ) ) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.Inspection by-Consignee
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Half ( ( As per drg no. AGC/HALF LOC/ 2023/01 issued vide NCR letter no. NCR/S&T/8005/TYPICAL/PT-4 Dt.14.08.2025 or latest ) with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.Inspection by-Consignee
Supply of phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No. IS 2036 of 1995 or latest. Test report of manufacture to be supplied.Inspection by-Consignee
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, 22 fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. Th e iron angle for fixing shall be minimum 3 mm thick. Th is also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. Th e work shall be done as per instructions of Rly engineer at site. (Apparatus case Full) Inspection by-Consignee
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, 23 fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. Th e iron angle for fixing shall be minimum 3 mm thick. Th is also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half) Inspection by-Consignee
Supply and installation of earth electrode as per standard practice and as per NCR Drawing No. S&T/CONST/6.4/97. It includes supply of GI pipe of 3 meter length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter deep 24 and fi xing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing No. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS fl at size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS fl at to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge.Inspection by-Consignee
Embedded software modification in (1) FEP in test room and (2) CMU in test room, to accept and transfer the relevant station data to a client PC. Inspection by-Consignee
"Alteration of Existing Circuit Diagrams consisting of the items as mentioned & submission 26 of Three paper copies for approval (i)Wiring Diagrams (ii) Relay Disposition Charts (iii) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for El Systems" Inspection by-Consignee (Sheet= Per Sheet)
Alteration of Existing Location Box Drawings (Including Contact Analysis, Fuse Particulars etc.) and submission of Three paper copies for approval. Inspection by-Consignee (Sheet=Per Sheet)
Supply of Remote service terminal (portable) fully compatible with NMS software. Service 28 terminal shall be workable from any location of the network. It should be possible to read the fault status of the STM, MUX, cross connect etc. in the network from the service terminal. Make and model to be approved by railways before supply.Inspection by-Consignee
Supply of Modular Power Supply DC-DC Converters, Input: 110VDC, Output: 24VDC/10A or Input: 110VDC, Output: 12VDC/10A Make- Gallant or better."Inspection by-RDSO"
Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest."Inspection by-RDSO"
Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire ,85 conductor 31 each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge."Inspection by-Consignee"
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge."Inspection by-Consignee"
Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge."Inspection by-RITES"
Supply and installation of Cable Termination(CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements 34 and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant and powder coated."Inspection by-Consignee"
Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, 35 capacitors, insulators. grouting bolts, tripods etc. as per approved drawing of NCR [Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion). Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)"Inspection by- Consignee"
Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, 36 scaffolding, ladders. runway for cables, fixing of Relay / Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on NCR & the instructions of Rly engineer at site."Inspection by-Consignee"
Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board 37 (base plate), connectors,retaining clips etc. and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH"."Inspection by-RDSO"
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks 38 and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge. (Supply of all above terminals has been covered separately). "Inspection by-Consignee" Per
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals 39 provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. Th e item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. Th e outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engineer incharge of the work."Inspection by-Consignee" Unit Above/
Supply of PVC insulated multi strand 35 Sq. mm. Cu Cable as per IS:694 or latest for connecting earth bus bar to earth electrode."Inspection by-Consignee" 5100188.1
"Modification / Alteration in existing EI (Electronic Interlocking) as perlatest RDSO guidelines/TAN. It includes: Design and modifi cation in existing Interface and Interlocking circuits and logic of EI system including modifi cation in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifi cations and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. Th e work also includes the supply of modifi ed Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying 41 out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Note-1 :The work also includes the directinterfaced of the Datalogger withElectronics interlocking systemthrough Ethernet based serialport. All necessary hardware required for EI- Datalogger Ethernet based interface such asprotocol convertor and switchesare to be supplied by the vendor. Note-2 : The work also includesthat if Ethernet based EI-TCAS interface is already commissionedin the station, then EI logic shouldin such a way that it communicateall required bits as decided by railway to Kavach. Any modification required at Kavach end (Kavach Logic) to maintainthe EI- TCAS interface would be the responsibility of the Railway. Note-3 : FAT would be conducted two round if SAT would notfeasible at site. (For NYN and SFG)" Inspection by-Consignee 16068250.
"Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modifi cation in existing Interface and Interlocking circuits and logic of EI system including modifi cation in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifi cations and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. Th e work also includes the supply of modifi ed Selection 42 table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Note-1 :The work also includes the directinterfaced of the Datalogger withElectronics interlocking systemthrough Ethernet based serialport. All necessary hardware required for EI- Datalogger Ethernet based interface such asprotocol convertor and switchesare to be supplied by the vendor. Note-2 : The work also includesthat if Ethernet based EI-TCAS interface is already commissionedin the station, then EI logic shouldin such a way that it communicateall required bits as decided by railway to Kavach. Any modification required at Kavach end (Kavach Logic) to maintainthe EI- TCAS interface would be the responsibility of the Railway. Note-3 : FAT would be conducted two round if SAT would notfeasible at site. (For PCOI)" Inspection by-Consignee
Supply and placing of trunking and capping (RCC Duct) of size 300mmx300mm as per STS/E/Cable-Laying Practices Vol-IV Date: 16.05.2024, or latest for 'Guidelines on signalling cable laying. "Inspection by-RITES"
Software modification and relay wiring of old and new relays / analog input with Data Logger 44 to communicate with the Data Entry Terminal of the ASM and pass the information through the Data Logger network (for existing datalogger station and LSC). Note: It also includes wiring of the new bits to the datalogger as per engineer's instructions. Software modification of the existing datalogger to suit the EI- Datalogger Ethernet-based interface."Inspection by-Consignee"
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .