| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹28.9 L+₹5.4 L (22.9%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹29.6 L+₹6.1 L (26.0%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹32.3 L+₹8.8 L (37.6%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹33.7 L+₹10.2 L (43.5%)Rejected-AOC | L5 | Rejected-AOC Rejected not being l1 |
Tender Value
₹41.3 L
EMD Value
₹82,500
Closing Date
13 Jun 2025, 6:00 pmClosed
Lt Col Sanjay Siwach, GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR / MAINT OF EXT ELECT INCL LT OHT LINES, LT PANELS, APFC PANELS , MCCBS, EARTHING , UG CABLES ,LT POLES , STREET/ PERIMETER LIGHTS AND CONNECTED WORKS AT JAK LI RC UNDER GE 970 EWS
2025_MES_708544_1
GE 970 EWS-04/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAK LI RC SRINAGAR
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹82,500
Yes
22 Jul 2025
16 May 2025
18 Jun 2025
16 May 2025
13 Jun 2025
31 May 2025
Amount
Taking out old unserviceable ACSR conductor of any size from existing poles at various locations of JAK LI RC parameter tree distribued area incl aluminium binding wires,jumpering,bindings, insulators cross arms, bracings, supports , clamps and back plate stay wire etc complete all as specified and directed.
M & L for ACSR conductor including stringing on LT poles complete incl aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and directed.
M & L for galvanised steel wire 4 mm dia to be stringed as continuous earthing wire on over head LT lines complete all as directed incl taking down the old rusted earth wire complete all as specified and directed.
S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as specified and directed.
M & L for galvanised stay strand size 7/4 mm complete all as directed incl taking down the old unserviceable stay wire complete all as specified and directed.
M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down complete all as specified and directed.
Taking out old unserviceable steel tubular poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed.
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding incl aluminium winding wires, tapes etc and jumpering for any type of conductor complete of single run conductor all as directed. Note: Triming of tree branches upto 3 mtrs from the conductor is deemed to be included in the rates quoted complete all as specified and directed.
Supply and fix in replacement of insulator pin type porcelain vitereous , white brown or green insulator including one galvanised mild steel spindle, two galvinised washer and one GI nut 100 mm height and 65 mm dia for 1100 Volt grade complete all as specified and directed.
Supply and fix in replacement of insulator shackle type, porcelain, vitereous, white brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washer and nuts for working pressure 1100 Volts height 100mm, dia 115mm, section of strap (31x5) mm dia of bolt 14 mm complete all as specified and directed.
Supply and fix in replacement of loop type insulator vitreous white,brown or green insulator small size,with over all dimensions 65 x 90 mm,clearance of hole 16 mm complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down existing cable, complete, all as specified and directed .
10 Sqmm 2 Core.
16 Sqmm 2 Core.
16 Sqmm 4 Core.
25 Sqmm 3.5 Core.
35 Sqmm 3.5 Core.
50 Sqmm 3.5 Core.
70 Sqmm 3.5 Core.
95 Sqmm 3.5 Core.
120 Sqmm 3.5 Core.
150 Sqmm 3.5 Core.
240 Sqmm 4 Core.
Supply and fixing of ACB 4 Pole, 415 V, with with adjustable thermal and magnetic relay type, 630 Amps capacity incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 400Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay, Ics=100% Icu, 75% Icu incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 400Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay, Ics=100% Icu, 75% Icu incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 250Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 200Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 160Amps 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 125Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 100Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 63Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed. Make : L&Tor equivalent
Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed.
Supply and replacing of 1100 volts grade heavy duty cable PVC insulated copper conductor as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 10 sqmm 2 core complete all as specified and directed.
M & L for trimming of tree branches touching or leaning over overhead power lines of one span 2 to 5 span in same pole will be measure as one unit) and removing of cut tree branches from the site complete all as directed.
M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point, testing complete all as specified and directed.
M & L for earth continuity conductor using GI strip 32 x 6 mm as earthing lead complete all as directed incl taking down the old unserviceable complete all as specified and directed.
M & L for house service bracket (hook type ) complete with 3.0M long GI pipe 40mm dia medium grade two nos 90 degree bends , MS Hook and stay or guy complete all as specified and directed.
Supply and installation of on load change over switch in sheet metal enclosure of capacity 63 Amps, 4 pole complete all as specified and directed.
Taking down existng unserviceable street/security light fittings HPSV/HPMV/MH/Tube light fittinsgs of any capacity any type from pole/wall afte disconnection the connecting wires , carrying to store yard for necessry repair/replacement of spares etc complete all as specified and as directed. Note: new spares required to be replaced and cost shall be deemed in the quoted rate.
Refixing only the street light fittings after repair obtained from item No. 36 here in before incuding making connections with cables and testng complete all as specified and as directed. Note: Cable required for replacement shall be measured and paid separately.
S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 45W mounted on MCPCB suitable for 35mm dia pipe in gress protection IP-66 complete all as specified and as directed.
S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.
S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.
S & F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 70W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.
Taking down after disconnection of old UNSV of Post top light fitting and supply and fixing of LED based energy saving & environment friendly long life versatile luminaire made in pressure die cast housing and heat sink with aluminium extruded with IP-65 of 30 watt complete with front toughened glass cover including connection with 2.5 sqmm 3 core PVC insulated copper wire complete all as specified. Make : Bajaj or equivalent in Havells/CG.
Tking down after disconnection of lod UNSV of high mast light fittings and supply and fixing in replacement of lED based saving & enviorment friendly long life versatile flood light Lumos IP-65 of 200 W complete with front glass cover complete as specified. Make Bajaj or its equivalent make of philips/CG
Supply and fixing in replacement of LED driver for suitable for 45W to 60 W complete all as specified and directed.Make: Hvells/Bajaj/CG
Supply and fixing in replacement of LED driver for suitable for 70 W to 120 W complete all as specified and directed. Make: Hvells/Bajaj/CG
Replacement of connection junction box made out of 1.6mm thick MS sheet front openable, weather & vermin proof incl painting two coats of synthetic enamels paint over coat of red oxide primer. Connection box shall be suitable for housing & incl AI bus bar 25 Amps Cap 2 Nos. MCB SP6 Amps-01 No and having provision of cable hole in bottom for two to three cables of size 10 Sqmm 2 core armoured cable connection boxshall be fitted on street light pole and fixing arrangements i.e MS clamps etc deemed to be provided by the contractor, size of box 200x150x100mm complete all as specified and directed.
M & L for Cutting out the burnt out cable end and reconnecting with providing new lugs,tapes etc for cable size 25 sqmm 3.5 core to 50 sqmm 3.5 core complete all as specified and directed.
M & L for Cutting out the burnt out cable end and reconnecting with providing new lugs,tapes etc for cable size 70 sqmm 3.5 core to 150 sqmm 3.5 core complete all as specified and directed.
S & F PVC Line spacer of superior quality of 4 Way spiral type all as specified and as directed.
S & F PVC Line spacer of superior quality of 6 Way spiral type all as specified and as directed.
M & L for earth continuity conductor /main earthing lead fixed to wall/batten or recess/chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm complete all as specified and directed.
M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and GI strip as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point, testing complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in any type of soil complete all as specified and directed.
Excavation in trenches exceeding 1.5 mtr wide and exceeding 1.5 mtr depth and getting out in any type of soil complete all as specified and directed.
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer complete all as specified and directed.
Removing excavated material to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches complete all as directed. Note : Punned thickness only measured and paid.
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for foundation of pole & stay complete all as specified and directed.
M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as specified and directed.
M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for copining of pole complete all as specified and directed.
Notes :- An amount of ` 3,43,622.00 on account of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum
M/s Jaipal Associates (BID ID -3315246)
M/s Nasir Rasool Dar (BID ID -3314047)
M/S Noor Mohammad Shalla (BID ID -3322093)
M/S GHULAM HASSAN KUCHAY (BID ID -3314799)
M/S MIR SAJAD ENTERPRISES (BID ID -3321798)
M/S N A Enterprises (BID ID -3311443)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .