| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.6 L+₹39,410.35 (1.40%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.8 L+₹52,547.14 (1.86%)Rejected-AOC GANAKPARA CITY TOWN UDALGURI P O BHOLABARI P S KALAIGAON DIST UDALGURI ASSAM PIN 784525 | DARRANG | ASSAM | 784525 | L3 | Rejected-AOC L3 |
Tender Value
₹26.3 L
EMD Value
₹52,547
Closing Date
2 Mar 2020, 4:30 pmClosed
Add. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Construction of Boundary Wall, Building repairing and Garage at Kalaigaon Transport Office in Udalguri District.
2020_BTC_16550_1
ACE-35/TECH/UDL(R B)/IFB/2018-19/159
Open Tender
Civil Works - Building
Item Rate
180 days
Kalaigaon, Udalguri Dist.
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Principal Secretary, BTC, Kokrajhar
₹52,547
Yes
13 May 2020
17 Feb 2020
3 Mar 2020
17 Feb 2020
2 Mar 2020
17 Feb 2020
17 Feb 2020 - 2 Mar 2020
Amount
Construction of Garage 1.1. Earth work in excavation for foundation trenches of wall relating walls, footing of column, steps septic tank etc. (A) Up to a depth of 2m below the existing G.L. (a) In ordinary soil. Post, Wall
4.1.1. Providing soiling in foundation and under floor with stone/best quality Jhama bricks and packed etc. (a) Brick flat soiling, Post, Wall
2.1.1. Plain cement concrete work with coarse agg. Of size 13mm to 32mm in foundation bed for flooring step wall etc. (a) In prop. 1:3:6, Post, Wall
18.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant IS code etc. (a) Other ISI approved T.M.T. reinforcement bar (SRMB/BISCON/ X TECH) (For Assam Type Bldg, drain, B. wall etc.) 16mm dia, Post, T. Beam, C. Beam, 12mm dia, Post, Linter, 10mm dia, Jali
(C ) ISI approved M.S. bar 6mm dia, post, T. Beam, Linter
3.2.1. Providing from work of 12mm thick Plywood Board so as to give a rough finish incl. centering shuttering etc. 3.2.1.1. Column, pillars, posts & strut of square/rectangular etc. Base, Post.
3.1.1.4. Sides and soffits of beam, beam hunching, cantilever etc. Lintel etc. T. Beam, Lintel
2.2.1. Providing and laying plain/reinforced cement concrete concrete work With coarse sand and 20mm down graded stone etc. (a) In substructure up to P.L. foundation, footing, column With base tie and Plinth level (b) M20 or Prop. 1:1.5:3
(b) In substructure from P.L. up to 1st floor level. (ii) Columns, pillars, post, strut, suspended floor, Roof etc. (b) M20 or in prop. 1:1.5:3, Post, L/C Beam
4.1.4. Brick work in cement mortar with 1st class brick incl. racking Out joints and dewatering etc. (i) in sub structure (b) In prop. 1:4 Wall, Ramp
30.2. Construction of granular sub-base by providing close graded material spteading in uniform layers with motor grader on prepared surface etc. (with an initial lead of 5km) (b) Using Grading I material. Room
(d) Extra Lead beyond initial lead of 5.00 km, Gitibari to Site
2.1.3. Providing and laying 25mm thick damp roof course with Cement concrete in prop. 1:1.5:3 etc., Wall
4.1.8. 1st class brick nogged wall in cement mortar including racking out joint and curing complete above PL up to 1st floor level. (A) 112mm thick brick wall (a) In prop. 1:4
18.3.1. Providing fitting. Hosting and fixing of roof trust incl. Purlin fabricated out of MS black tube conforming to relevant IS code as per approved design etc. 65mm dia O.D. Pipes. 50mm dia O.D. Pipes
8.1.35. Providing Pre Painted Galvanized Iron Sheet Roofing (Dyna roof/Satham/Durakolor/Century Wells) at all level etc. (v) 0.60mm thick.
8.1.36. Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges/Velley/Gitter/Finishing) (Dyna roof/Sathyam etc, (iv) 0.60mm thick
9.4.1. Providing brage board of size 200mm X 20mm with 1st class local Hollokh/Bansum etc.
6.2.2. 15mm thick cement Plaster in single coat on single or Brick walls for interior plastering up to 1st floor level etc. (a) On Rough side (b) in prop 1:4, Wall
(b) On fair side (b) in prop 1:4 Wall, Post, Lintel
30.6. 15mm tick cement plaster in single coat with hardener of Recron/Degusa/Fosros on brick/concrete for plastering including arises, internal rounded angles, chamfers and /or rounded angles not exceeding 80mm in girth and finished etc. (a) in prop. 1:3
5.1.10. Cement plaster skirting with cement mortar in prop. 1:3 finished with a floating coat of neat cement etc. (a) 15mm thick.
2.1.2. Plain cement concrete floor base in prop. 1:3:6 laid in altermate bays as specified with coarse agg of size 13mm to 32mm including etc. (iii) 100mm thick, floor
13.4.7. Wall painting (two coats) with plastic emulsion paint Approved brand and manufacture (Asian paint/Berger Paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade etc. (a) Plastic emulsion paint Approved brand and manufacture (Asian paint/Berger Paint/ICI paint/J&N paint/Nerolac) Wall
13.9.2. Finishing old/new wall with waterproofing weather coat Smooth anti-fungal exterior painting of Apex brand of Asian paints of required shade etc. Wall, Post, Lintel
13.6.3. Applying primary coat over new wood and wood based Surface over 100mm in grith/width after and incl. preparing the surface etc. (b) With ready mixed paint, wood primer (Pink)
13.6.5. Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint etc. (a) General Purpose (Asian paint/Nerolac paint/J&N paint)
CONSTRUCTION OF BRICK BOUNDARY WALL(50 Rm) 1.1. Earth work in excavation for foundation trenches of walls, retaining wall, footing of columns, steps, septic tank etc. (A) Up to a depth of 2m below the existing GL (a) In ordinary soil. Post, Wall
4.1.1. Providing brick soling in foundation and under floor with stone/best quality Jhama brick sent pack etc. (a) Brick flat soling. Post, Wall
2.1.1. Plain cement concrete work with coarse agg of size 13mm to 32mm in foundation bed for 32mm in foundation bed for footing steps, wall etc. (b) In prop. 1:4:8, Post, Wall
2.1.3. Providing and laying 25mm thick damp roof course with Cement concrete in prop. 1:1.5:3 etc., Wall
18.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant I.S. code etc. (b) Other ISI approved T.M.T. reinforcement bar (SRMB/BISCON/ X TECH) (For Assam Type Bldg. drain, boundary wall etc. 12mm dia Post, Tbeam 8mm dia Jali
(C ) ISI approved M.S. Rod , 6mm dia: Stirrup, Post, T. beam
3.2.1. Providing from work of 12mm thick Plywood Board so as to give a rough finish incl. centering shuttering etc. 3.2.1.1. Column, pillars, posts & strut of square/rectangular etc. Base,
3.1.1.2. Sides of tie beam, plinth beam, grade beam etc.
2.2.1. Providing and laying plain/reinforced cement concrete work with coarse sand and 20mm down graded stone etc. (I) Using Mixer Machine (A) In substructure up to P.L. foundation, footing, column, base tie and plinth beam etc. (N) Without using admixture, plasticizer. (b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from P.L. up to 1st floor level. (ii) Column, pillar, Post, struts, suspended floor, roof etc. (N) Without using admixture, plasticizer. (b) M20 grade concrete or Prop. 1:1.5:3, Post
4.1.4. Brick work in cement mortar with 1st class brick incl. racking Out joints and dewatering etc. (i) in sub structure up to plinth level. (b) In prop. 1:4 Wall,
4.1.8. 112mm thick 1st class brick with 1st class brick incl. Racking out joints and curing complete above P.L. up to 1st floor level. (a) In prop 1:4, Wall
6.2.2. 15mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level etc. (A) On rough side, Wall
13.2.3. (a) Applying on coat of cement primer of approved brand and manufacture on wall surface after thoroughly brooming the surface etc.
(b) Finishing wall with water profing cement paint of approved brand and manufacture of required shade on new wall surface (Two coats) to give an even shade etc.
VERTICAL EXTENSION OF BOUNDARY WALL WITH GRILL(128.5 Rm) 23.1. Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials etc. Wall
23.3. Demolishing RCC work including stacking of steel bar and disposal of unserviceable material etc. Post
18.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant I.S. code etc. (b) Other ISI approved T.M.T. reinforcement bar (SRMB/BISCON/ X TECH) (For Assam Type Bldg. drain, boundary wall etc. 12mm dia Post,
(C ) ISI approved M.S. Rod , 6mm dia: Post
3.2.1. Providing from work of 12mm thick Plywood Board so as to give a rough finish incl. centering shuttering etc. 3.2.1.1. Column, pillars, posts & strut of square/rectangular etc. Base, Post
2.2.1. Providing and laying plain/reinforced cement concrete work with coarse sand and 20mm down graded stone etc. (I) Using Mixer Machine (A) In super structure from P.L. up to 1st floor level (ii) Column, pillar, posts, struts, suspended floor, roof etc. (N) Without using admixture, plasticizer. (b) M 20 grade concrete or Prop. 1:1.5:3, Post
4.1.8. 1st class brick nogged wall in cement mortar including racking out joint and curing complete above PL up to 1st floor level. (A) 112mm thick brick wall (a) In prop. 1:4 wall
6.2.3. 15mm thick cement plaster in single coat on rough side of Brick/concrete walls for interior plastering up to 1st floor level etc. (A) On rough side (b) In prop. 1:4, Wall
10.2. Providing fitting and fixing M.S. grill of required for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round handed bolts and nuts or screws. (C ) Fixed to Brick work/PCC/RCC grill
13.7.2. Applying primary coat over new matel and matel based Surface over 100mm in grith/width after and incl. preparing the surface etc. (b) With ready mixed paint, matel primer (Pink) grill
13.7.4. Painting two coats (excluding priming coat) on new steel and other materials surface with enamel paint etc. (i) Surface over 100mm in width or grith. (b) General purpose (Asian paint/Nerolac paint/J&N paint)
13.2.3. (a) Applying on coat of cement primer of approved brand and manufacture on wall surface after thoroughly brooming the surface etc. Wall, Post
(b) Finishing wall with water profing cement paint of approved brand and manufacture of required shade on new wall surface (Two coats) to give an even shade etc.
VERTICAL EXTENSION OF BOUNDARY WALL INCLUDING RCC WORK(106 Rm) 23.7. Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials etc. Wall
23.3. Demolishing RCC work including stacking of steel bar and disposal of unserviceable material etc. Post
18.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant I.S. code etc. (b) Other ISI approved T.M.T. reinforcement bar (SRMB/BISCON/ X TECH) (For Assam Type Bldg, drain, boundary wall etc. 12mm dia, Post
(C ) ISI approved M.S. Rod 6mm dia, Post
3.2.1. Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering shuttering etc. 3.2.1.1. Column, pillars, posts & strut of square/rectangular etc. Post
2.2.1. Providing and laying plain/reinforced cement concrete work with coarse sand and 20mm down graded stone etc. (I) Using Mixer Machine (B) In super structure from P.L. up to 1st floor level. (ii) Column, pillar, posts, struts, suspended floor, roof etc. (I) Without using admixture, plasticizer. (b) M20 grade concrete or Prop 1:1.5:3, Post
4.1.4. Brick work in cement mortar with 1st class brick including racking out joints and dewatering etc. (I) In super structure from PL up to first floor level. (b) In prop. 1:4 Wall
4.1.8. 1st class brick with 1st class brick incl. Racking out joints and curing complete above P.L. up to 1st floor level. (A) 112mm thick brick wall (a) In prop. 1:4, Wall
6.2.3. 15mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level etc. (A) On rough side (b) In prop 1:4, Wall
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly booming the surface etc. Wall
(b) Finishing wall with water profing cement paint of approved brand and manufacture of required shade on new wall surface (Two coats) to give an even shade etc.
Heavy Duty Iron Gate Double Leaf 1.1. Earth work in excavation for foundation trenches of walls, retaining wall, footing of column, steps, Septic tank etc. (a) Up to a depth of 2m belew the existing GL. (a) In ordinary soil.
4.1.1. Providing brick soling in foundation and under floor with stone/best quality Jhama brick sent pack etc. (a) Brick flat soling. Post, Wall
2.1.1. Plain cement concrete work with coarse agg of size 13mm to 32mm in foundation bed for 32mm in foundation bed for footing steps, wall etc. (b) In prop. 1:4:8, Post, Wall
18.1.1. Supplying fitting and fixing in position reinforcement bars conforming to relevant I.S. code etc. (b) Other ISI approved T.M.T reinforcement bar (SRMB/BISCON/X TECH) (For assam type Bldg, drain, boundary wall etc. 16mm dia: Post, Beam. 12mm dia: Post, 10mm dia, Jali
(C ) ISI approved M.S. bar 6mm dia, post, Beam
3.2.1. Providing from work of 12mm thick Plywood Board so as to give a rough finish incl. centering shuttering etc. 3.2.1.1. Column, Pillars, posts & strut of square/rectangular etc. Post
3.2.1.2. Sides of tie beam, plinth beam, grade beam etc. For depth not exceeding 1.00m, Tie beam
2.2.1. Providing and laying plain/reinforced cement concrete work with coarse sand and 20mm down graded stone etc. (I) Using Mixer Machine (A) In substructure up to P.L. foundation, footing, column with base tie and plinth beam etc. (N) Without using admixture, plasticizer. (b) M20 gade concrete or Prop.1.1.5:3
(B) In super structure from P.L. up to 1st floor level (ii) Column, pillar, posts, struts, suspended floor roof etc. (A) M20 grade concrete or Prop. 1:1.5:3. Post
4.1.4. Brick work in cement mortar with 1st class brick including racking out joints and dewatering etc (I) In sub structure up to plinth level. (b) In prop. 1.4
6.2.2. 15mm thick cement plaster in single coat on rough side of brick/concrete walls for interior plastering up to 1st floor level etc. (A) On rough side. (b) In prop 1:4
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly booming the surface etc.
(b) Finishing wall with water profing cement paint of approved brand and manufacture of required shade on new wall surface (Two coats) to give an even shade etc.
17.11. Providing fitting and fixing double leaf Iron gate etc. complete
13.7.2. Applying primary coat over new Mattel and Mattel based surface over 100mm in girth/width after and including prearing the surface. (b) With ready mixed paint, matel primer (Pink)
13.7.4. Painting two coats (excluding priming coat) on new matel and matel based surface with enamel paint etc. (a) General purpose (Asian paint/Nerolac paint/J&N paint)
Madan Debnath
LANKESWAR RABHA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .