SE, EUDC-TECHNICAL, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
REPAIRING AND OVERHAULING OF 11 KV VCB WORK
2026_PVVNL_1185014_2
42/EUDC-T/2026-27/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
UNDER EUDD-33 KV YEIDA NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
SE, EUDC-TECHNICAL, NOIDA
₹5,000
Yes
5 Oct 2026
5 Oct 2026
13 Oct 2026
5 Oct 2026
13 Oct 2026
5 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1REAPIRING AND OVERHAULING OF 11 KV DIFFERENT MAKE VCB COMPLETE IN ALL ELECTRICAL/MECHANICAL WORKS INCLUDING REPAIRING & SETTING OF DEFECTIVE SYSTEM WITH SPARE PARTS & LEVERS FOR SMOOTH & PROPER OPERATIONS AND REMOVAL OF ELECTRICAL / MECHANICAL DEFECT OF 11 KV VCB FROM SWITCHGEARS INCLUDING MAKING BURNT WIRING, CHECKING PROPER & OK TRIPPING SYSTEM FROM RELAY OF 11 KV VCB WITH PANEL AT INSTALLED VARIOUS 33/11 KV SUB-STATIONS AT INSTALLED VARIOUS 33/11 KV SUBSTATION AS PER FOLLOWING :- NOTE: - THE REPAIR WORK SHALL BE INVOLVED IN CARRYING OUT THE REPAIR WORKS VCBs THE MAIN ITEMS / PARTS (DAMAGE / UNSERVICEABLE) SHALL BE PROVIDED BY THE DEPARTMENT FOR REPLACEMENT OF THE SAME & GEARS, BEARINGS, STUDS, INDICATOR LAMPS, FLEXIBLE COPPER WIRE LUGS, TIE, BAKELITE SOCKET, NUTS & BOLTS ETC. SHALL BE PROVIDED BY THE CONTRACTOR. | |||||
| 1.01 | PROVIDING AND REPLACEMENT OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING. | 1 | Nos. | 100 | ₹100 |
| 1.02 | PROVIDING AND REPLACEMENT OF 11KV VCB SPRING CHARGING MOTOR OF APPROPRIATE RATING/STANDARD MAKE. | 1 | Nos. | 100 | ₹100 |
| 1.03 | PROVIDING AND REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING. | 1 | Nos. | 100 | ₹100 |
| 1.04 | PROVIDING AND REPLACEMENT OF DEFECTIVE/BURNT AUXILLIARY SWITCH OF APPROPRIATE RATING. | 1 | Nos. | 100 | ₹100 |
| 1.05 | PROVIDING AND REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY. | 1 | Nos. | 100 | ₹100 |
| 1.06 | PROVIDING AND REPLACEMENT OF DEFECTIVE SPOUT R.Y.B. PHASE INCOMING & BUS BAR SIDE. | 1 | Nos. | 100 | ₹100 |
| 1.07 | PROVIDING AND REPLACEMENT OF DEFECTIVE JAW (MALE / FEMALE) FOR 11 KV VCB TROLLEY. | 1 | Nos. | 100 | ₹100 |
| 1.08 | PROVIDING AND REPLACEMENT OF DEFECTIVE AMPERE METER. | 1 | Nos. | 100 | ₹100 |
| 1.09 | PROVIDING AND REPLACEMENT OF DEFECTIVE TNC SWITCH. | 1 | Nos. | 100 | ₹100 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.39 MB
DOC.pdf
Tender Documents • 0.96 MB
BOQ_2251996.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .