| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC Lowest quoted tenderer | |
| 2 | L2₹32.7 L+₹29,991.60 (0.93%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹33.3 L+₹96,095.10 (2.97%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹33.9 L+₹1.5 L (4.77%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹36.0 L+₹3.6 L (11.3%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹75,900
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Allahabad
HQ CWE New Cantt Allahabad
PROVN OF RING MAINT CIRCUIT AND CONNECTED WORKS FOR OFFRS COLONY, PAWAN VIHAR AND NAIDU ENCLAVE AT OLD CANTT UNDER GE (EAST) ALLAHABAD.
2021_MES_489422_1
81650/E/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (East) Allahabad
₹75,900
Yes
10 Feb 2022
20 Nov 2021
29 Dec 2021
21 Nov 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including bottom surface to required level or slope for laying of cable etc. complete all as specified and directed.
Returning filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches and consolidated complete all as specified and directed. NOTE : Punned thickness 18 cm only shall be considered for payment.
Supply and laying un-reinforced precast concrete cable cover, Class HVP, type 1 with peak size 300mmx180mmx40mm complete all as specified and directed.
S & F for 80 mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hardstanding complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steely strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 V grade, of size 3 core 95 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed.
Earthing complete with galvanised iron strip 32×6mm as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
M&L Danger notice plate 1.6mm thick mild steel sheet, vitrcous enamelled white with letters, figures and conventional skull and bones in signal red and fixed with MS clamps, bolts and nuts of approved size for HT 25x20cm size complete all as specified and directed.
S&F cable route indicator made of 15x15x6mm thick MS plate welded with 8mmx30cm long MS rod grouted in PCC block of size .2x.2x.3m and writing HT cable complete all as specified and directed.
M&L for boring holes for Insertion of 80/50/40 mm dia GI pipe under PCC Road/ Taxi track/ hard standing not more than 12mm deep complete all as specified and directed.
KANISHKA ENTERPRISES
Diamond Electric Co.
GUPTA ENGINEERING WORKS
M/S VIJAY SINGH
ANKIT SHIP REPAIRERS AND SUPPLIERS
New Era Engineers
PARAMOUNT ELECTRICALS
RAMESH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .