| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹22.5 L+₹7.6 L (51.0%)Rejected-AOC SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹24.2 L+₹9.3 L (62.4%)Rejected-AOC 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹26.5 L+₹11.6 L (77.6%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹27.0 L+₹12.1 L (81.2%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
4 Feb 2023, 6:00 pmClosed
GE E/M RR HOSPITAL
GE E/M RR HOSPITAL RAO TULA RAM MARG DELHI CANTT 10
REPAIR/MAINT OF PACKAGE TYPE DUCTABLE AIR CONDITIONING PLANT OF VARIOUS CAPACITIES ,VRF ACS ,AHUS LT PANEL BOARDS AND ALLIED WORKS AT AHRR UNDER GE E/M RR HOSP DELHI CANTT-10
2023_MES_573690_1
GE/H-40/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSP DELHI CANTT-10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹58,000
Yes
10 Mar 2023
7 Jan 2023
6 Feb 2023
7 Jan 2023
4 Feb 2023
21 Jan 2023
Amount
Material and labour for serviceing of out door VRF ACs capacity up to 12 HP (Dendal New building) as per OEM direction with the help of Pressure Booster Pump along with chemical removing front PVC grills, air filters, cleaning, washing, removing dirt and including checking power connection .cheleaning / wash of cooling coil of outdoor cooling unit and condenser coil of out door unit and re-assembling the dismantled components of its original position complete all as specified and directed by Engr-in-Charge.
Material and labour for serviceing of out door VRF ACs capacity up to 10HP (Dendal New building) as per OEM direction with the help of Pressure Booster Pump along with chemical removing front PVC grills, air filters, cleaning, washing, removing dirt and including checking power connection .cheleaning / wash of cooling coil of outdoor cooling unit and condenser coil of out door unit and re-assembling the dismantled components of its original position complete all as specified and directed by Engr-in-Charge. Note - For ser item 1 and 2, during the contract period if more then one serviceing is requited based cooling efficiency deemed in the quoted rate and time to time checkup for the healthy condition of instruments/equiptment are deemed in the quoted rate.Serviceing hard ink sign copy should be deposit in this office before payment procedure.
Material and Labour for serviceing of Cassette unit of various capacity with the help of Air pressure and chemical washing including cleaning of air filter refixing in its original position complete all as specified and directed by Engr-in-Charge.
Material andn labour for fan coil unit (FCU) serviceing with the help of chemical cleaning and Pressure boster pump complete all as specified and directed by Engr-in-Charge.
Material and labour for Top up Gas Charging with R-410/R-22 for 22 HP VRF circuit (12 HP+10 HP) x4 Circuit and Package type AC any make or any cpacity all as directed by Engr-in-Charge.
M&L for throughly checkup for VRF outdoor & indoor communication estabilishing (12 HP+10 HP) x4 circuite all as directed by Engr-in-Charge.
S&F, in replacement of copper tubing of 3/8” dia suitable for VRF AC/Package type ACs as per existiong copper tube including brazing / cutting / bendinng all as specified and directed by Engr-in-Charge.
All as per item No. 07 here-in-before but copper tubing of 5/8” dia.
M & L for serviceing Air cooled scrool type chiller unit with multi compresor capaacity 15 TR to 30 TR ( -ART,JRC,BMT and Lab) as per direction of OEM comprising with folowing works (a) cleaning the cooling ,condense coil with the help of Pressure Booster Pump recommended chemical and removing extra deposit material (b) Checking the helthly condition of compressor along with electric cable connection. (c) PCB should be original sitting as per OEM recommendation and checking all electric cable connection ,during the serviceing if any type of cable for connection in the cheller unit should be replased by the contractor with out any cost effect .(d) Leakage test and pressure shoud be carried out during the serviceing .(e) During the serviceing if the required welding /brazing /nut/bolt and which are not menthion in the schedule but necessary for serviceing or made functional should be repaced by the contractor with out financial effects , complete all as specified and directed by Engr-in-charge. Note - during the contract period if more then one serviceing is requited based cooling efficiency and time to time checkup for the helthy condition of instruments/equiptment are deemed in the quoted rate.Serviceing hard ink sign copy should be deposit in this office before the payment procedure.
M&L for dismantling of electric driven horizontal induction motor of capacity 1.5 to 3 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as specified and directed by Engr-in-Charge. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
All as per srl item no 11.00 here-in-before but for 7.5 HP capacity complete all as specified and directed by Engr-in-Charge.
M&L for complete overhauling of condenser / chiller centrifugal pump set of up to 7.5 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing electric connection, dismantling the U/S pump set from MS foundation, detaching the pump, opening the pump, remelting the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body; complete replacement of impeller set with new; required replacement of Cushy foot anti vibration pad with and incl carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, gland packing, coupling assembly etc. and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as specified and directed by Engr-in-Charge. Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate .
S&F, in replacement of control MCB, C Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCB 32 Amp,4 pole, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCB 40 Amp,4 pole, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCB 63 Amp,4 pole, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCCB 63 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCCB 100 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCCB 160 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCCB 630 Amps, 3 pole, Micro processor based with breaking capacity 36KA, Ics = 100% Icu, with adjustable natural pole protection ,Innovative front indication LEDs ,adjustable over load setting alongwith Spreader terminals and phase barriers and taking downun serviceable one complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement, of MCCB 800 Amps, 3 pole, Micro processor based with breaking capacity 36KA, Ics = 100% Icu, with adjustable natural pole protection ,Innovative front indication LEDs ,adjustable over load setting alongwith Spreader terminals and phase barriers and taking downun serviceable one complete all as specified and directed by Engr-in-Charge.
Supply and fix three pole power contactor capacity 25 Apms type MNX25 415 Volt ,50 Hz,conforming IS/IEC 60947-4-1 & IEC 60947 suitable for 2NO+2NC,coil voltage 240 Volts,based on DIN Rail mounting facility complete all as specified and directed by Engr-in-Charge.
Supply and fix three pole power contactor capacity 18 Apms type MNX18 415 Volt ,50 Hz,conforming IS/IEC 60947-4-1 & IEC 60947 suitable for 1NO+1NC,coil voltage 24 Volts,based on DIN Rail mounting facility,including oxilary mounting kit, complete all as specified and directed by Engr-in-Charge.
Supply and fix three pole power contactor capacity 12 Apms type MNX12 415 Volt ,50 Hz,conforming IS/IEC 60947-4-1 & IEC 60947 suitable for 1NO+1NC,coil voltage 24 Volts,based on DIN Rail mounting facility,including oxilary mounting kit, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement front mounting auxilary contact blocks for suitable contactor any description type 2NO+2NC (MNX/MCX) complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement front mounting auxilary contact blocks for suitable contactor any description type 1NO+1NC (MNX) complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of over load relay MN2 range 3 - 5 Amps, with built in single phase preventer, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of over load relay MN2 range 9-15 Amps, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection includign taking down old unserrviceable item, complete all as specified and directed by Engr-in-Charge.
Supply & fixing In replacement of Star Delta electronic timer time delay 3 to 30 second as per existing size and complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of single phase preventor relay TYPE Sz5(6wire version ) 415 V ,mode of operation Auto/Manual/Bypass, auto restrat with in 30 sec suitable for Star-delta strater incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of LED type indicator lamp of red/blue/green colour for phase indication, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Start/Stop push button, projecting head (push function) type, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of current transformer of 30/5A,15 VA Class 1 burden, suitable to measuring current, complete all as specified and directed by Engr-in-Charge.
M & L for panel wiring in replacement of un-armoured 10 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as specified and directed by Engr-in-Charge.
M & L for panel wiring in replacement of un-armoured 6 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
M & L for panel wiring in replacement of un-armoured 0.75 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of unservicable connector of suitablefor 16 Sq mm capacity 15A for making electric connections in LT panel board, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of old unservicable PVC chanel for panel wiring complete all as specified and directed by Engr-in-Charge.
M&L for applying one coat of synthetic enameled spray paint of existing colour on steel/iron surfaces of pipes, LT panel boards etc with and incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc and making surfaces smooth for achieving better grip between surface and primer, complete all as specified and directed by Engr-in-Charge.
S & F Sheet metal enclosure of size 600 mm X 450 mm X 300 mm made with the help of 2 mm thick CRCA Sheet suitable for MCCB /Star & Delta switch gear/relay etc,Switch gear should be hold on the shock proof Iylam sheet of 10 mm htick , fornt door should be openable type holding with hinges and lock and key system for protection , start/ stop button and three phase indicator lamp including volt/ameter approches or hole made on front door ,single phase MCB busbar 200Amps Capacity consist in the boses, complete all as specified and directed by Engr-in-Charge. Note - fasten for nut and bolt /anchoring hook /drilling/colour painting deemed inthe quotd rate and Switch gear should be measured and paid seperately.
S & F three phase VFD (Variable Frequency Drive ) 7.5 Hp to 15 Hp capacity compact type with micro processor suitable for controlling of motor speed working voltage 415 Volt,50 Hz including cable connection as per existing position and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Taking down of old defective/unserviceable and worn out material from package type ACs of capacity 17.0 TR or 8.5 TR like out door /indoor motor ,compressor,any type of contactor , V-Belt,expension valv,drier,Air filter and condenser coil etc complete all as specified and directed by Engr-in-Charge.
M&L for three phase out door fan motor capacity 370 watt,415 volt ,50 Hz for Pakage type AC's of capacity 17.0 TR complete all as specified and directed by Engr-in-Charge.
M & L for three phase indoor fan motor capacity 370 watt,415 volt ,50 Hz for Pakage type AC's of capacity 17.0 TR complete all as specified and directed by Engr-in-Charge.
S& F in testing and commissioning scroll Compressor capacity 8.5 TR for pakage type ACs and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make - Carrier (as per existing compressor)
Supply and fix V-Belt for the compressor type B-36 suitable for package type AC Capacity 17.0 TR including taking down u/s item complete all as specified and directed by Engr-in-Charge.
M&L for three phase ,415V 50 Hz motor rewinding capacity 3 HP including taking down old unserviceable , making the good fixing in the same position complete all as specified and directed by Engr-in-Charge.
M&L for accurate and stable feeding mechanism that supports scanning complete all as specified and directed by Engr-in-Charge.
S & F testing and commisioning Expension valve it should be converts high-pressure liquid to low-pressure liquid suitable for the package type AC s 17.0 TR /8.5 TR capacity including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
S & F ODF filter drier 5/8" suitable for existing package type AC of capacity 17 TR,/8.5 TR ACs including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F Air filter for package type ACs of capacity 17.0 TR /8.5 TR including taking down old unserviceable one all complete all as specified and directed by Engr-in-Charge.
S & F testing and commissioning of 5/8 inches and 3/8 inches high pressure /high tempraure (Constructed of industrial grade bras ) highly responsive valve.It should open and close in less than 1 second, electric oprated for package type AC s capacity 17.0 TR complete all as specified and directed by Engr-in-Charge.
M & L for 17.0 TR cooling coil including cleaning with chemical, removing settled down dust or chemical partical from the coil and out door unit two quote painting over one qoute of primer with rubbing of existing painting, to make the surface smooth complete all as specified and directed by Engr-in-Charge.
S & F testing and commissiong copper condence coil suitable for 8.5 TR and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
S & F of fan of size 18 inches (including testing and commissioning) working with three phase 415 Volt 50 Hz suitable for package type ACs of capacity 8.5 TR complete all as specified and directed by Engr-in-Charge.
S & F testing and commissioning of remort controll kit, comprising with following features ,memory retention,LCD backlite, large display panel & luxury style,Power button Built-in power indicator, easy to identify the work of the host state,automatic controll (cooling, dehumidification, ventilation, heating),switching for high power supply and prevent to high voltage /low voltage ,sleep mode function,Compressor 3-minute delay protection etc as per existing model complete all as specified and directed by Engr-in-Charge.
S & F testing and commissioning of blower unit for Pakage type ACs of capacity 8.5 TR complete all as specified and directed by Engr-in-Charge.
M & L for serviceing with the help of chemical / buster pump and cleaning the out door and in door unit including washing ,dust ,greasing ,checking the controll cable and all connected items complete all as specified and directed by Engr-in-Charge.
M&L for Serviceing of single phase Voltage Stabelizer of 4 to 5 KVA capacity including taking out warnt and unservicible material made functional including painting refix in original position all as specified and directed by Engr -in-Charge . Note - Spair parts like switch ,digital input/out put display,cable treminal ,gland and cable 1.5 sq mm/2.5 Sq mm up to 1.5 mtr deemed in the quoted rate , Transformer and PCB card measured paid seperately complete all as specified and directed by Engr-in-Charge.
S & F copper winding Tranformer for voltage stabelizer of capacity 4/5 KVA including connection of lead and connected all acessary and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
S & F PCB Card for voltage stabelizer of capacity 4/5 KVA made function unserviceable stabelizer and taking down old U/S PCB complete all as specified and directed by Engr-in-Charge.
S & F PVC insulated insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 10 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable complete all as specified and directed by Engr-in-Charge.
S & F PVC insulated insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 16 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable complete all as specified and directed by Engr-in-Charge.
S & F PVC insulated insulated LT XLPE armoured heavy duty electric cable 3.5 core with aluminium conductor,1100 volt grade cross-sectional area 25 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable complete all as specified and directed by Engr-in-Charge.
INDO CONSTRUCTION
Sai Enterprises
SNOWY ENGINEERING INC
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .