Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 7 CHANDRAVIJAY CHS L T ROAD MUMBAI SUBURBAN MUMBAI MAHARASHTRA 400081 | MUMBAI SUBURBAN | MAHARASHTRA | 400081 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹2.6 L (14.3%)Rejected-AOC PLOT NO 82A SECTOR 5 IMT MANESAR GURGAON HARYANA 122051 | GURUGRAM | HARYANA | 122051 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | VARDAN ENVIROLAB L2 | MAHABAL ENVIRO ENGINEERS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00AIR POLLUTION | |||||
| 1.10 | Determination of Mercury in the Stack emission of 1x500 MW,SGTPS,MPPGCL,Birsinghpur. | 12 | Monthly | 7,200 ₹8,496 Lowest | 15,120 ₹17,841.6 |
| 1.20Determination of parameters of Ambient Air Quality at wind-ward direction (S.W.)(near CAAQMS-1) inside power house premises for following:- | |||||
| 1.21 | Lead (Pb) in µg/M3 | 104 | twice in a week | 15,600 ₹18,408 | 11,960 ₹14,112.8 Lowest |
| 1.22 | Ammonia (NH3) in µg/M3 | 104 | twice in a week | 15,600 ₹18,408 | 11,960 ₹14,112.8 Lowest |
| 1.23 | Benzene (C6H6) in µg/M3 | 104 | twice in a week | 20,800 ₹24,544 | 11,960 ₹14,112.8 Lowest |
| 1.24 | Benzo (a) Pyrene (BaP)
(particulate phase only) in ng/M3 | 104 | twice in a week | 20,800 ₹24,544 | 11,960 ₹14,112.8 Lowest |
| 1.25 | Arsenic (As) in ng/M3 | 104 | twice in a week | 20,800 ₹24,544 | 11,960 ₹14,112.8 Lowest |
| 1.26 | Nickel (Ni) in ng/M3 | 104 | twice in a week | 20,800 ₹24,544 | 11,960 ₹14,112.8 Lowest |
| 1.27 | Mercury (Hg) in ng/M3 | 12 | Monthly | 2,400 ₹2,832 | 2,280 ₹2,690.4 Lowest |
Tender Value
₹22.7 L
EMD Value
₹45,500
Closing Date
2 May 2023, 3:00 pmClosed
SE PnW, SGTPS, MPPGCL, Bisinghpur
SE PnW, SGTPS, MPPGCL, Bisinghpur
Annual work contract for Third party monitoring work of Air, Water, Noise pollution and collection and testing of used oil (Lubricating Oil, Transformer oil and Fire resistance fluid (FRF)) for 4x210 MW and 1x500 MW, at SGTPS MPPGCL Birsinghpur.
2023_MPPGC_253885_1
253885
Open Tender
Miscellaneous Works
Fixed-rate
365 days
SGTPS, MPPGCL, Birsinghpur
As per NIT
17 documents required · 17 mandatory
₹1,000
Yes
₹45,500
Yes
15 Oct 2025
27 Mar 2023
8 May 2023
27 Mar 2023
2 May 2023
27 Mar 2023
AIR POLLUTION
Determination of Mercury in the Stack emission of 1x500 MW,SGTPS,MPPGCL,Birsinghpur.
Determination of parameters of Ambient Air Quality at wind-ward direction (S.W.)(near CAAQMS-1) inside power house premises for following:-
Lead (Pb) in µg/M3
Ammonia (NH3) in µg/M3
Benzene (C6H6) in µg/M3
Benzo (a) Pyrene (BaP) (particulate phase only) in ng/M3
Arsenic (As) in ng/M3
Nickel (Ni) in ng/M3
Mercury (Hg) in ng/M3
Determination of parameters of Ambient Air Quality at Lee-ward direction (N.E.)(near CAAQMS-2 room) inside power house premises for following:-
Perticulate matter (size less than 10 µm) or PM10 in µg /M3
SO2 in µg /M3
NO2 in µg/M3
CO in mg/m3
Perticulate matter (size less than 2.5 µm) or PM2.5 in µg /M3
Ozone (O3) in µg/M3
Lead µg/M3
Ammonia (NH3) in µg/M3
Benzene (C6H6) in µg/M3
Benzo (a) Pyrene (Bap) (-particulate phase only) in ng/M3
Arsenic (As) in ng/M3
Nickel (Ni) in ng/M3
Mercury (Hg) in ng/M3
Determination of parameters of Ambient Air Quality in Colony/residantial area :-
CO in Mg/M3
Ozone (O3) in µg/M3
Lead (Pb) in µg/M3
Ammonia (NH3) in µg/M3
Benzene (C6H6) in µg/M3
Benzo (a) Pyrene (BaP) (particulate phase only) in ng/M3
Arsenic (As) in ng/M3
Nickel (Ni) in ng/M3
Mercury (Hg) in ng/M3
Determination of parameters of Ambient air quality in two directions :- 01. At wind-ward (SW) direction - (Changera village) 02. At Lee-ward (NE) direction - (Mundaria village) outside power house premises for following:-
Perticulate matter (size less than 10 µm) or PM10 in µg /M3
SO2 in µg /M3
NO2 in µg/M3
CO in mg/m3
Perticulate matter (size less than 2.5 µm) or PM2.5 in µg /M3
Ozone (O3) in µg/M3
Lead µg/M3
Ammonia (NH3) in µg/M3
Benzene (C6H6) in µg/M3
Benzo (a) Pyrene (Bap) (-particulate phase only) in ng/M3
Arsenic (As) in ng/M3
Nickel (Ni) in ng/M3
Mercury (Hg) in ng/M3
WATER POLLUTION
Collection and Testing of Ash Bund Effluent from Ash Dyke for following, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified :-
Oil & Grease (mg/l)
Colour (Hazen unit)
Total dissolved solid (mg/l)
COD (mg/l)
Toxicity (Toxicity Factor-TF)
Odour
Arsenic (As) (mg/l)
Mercury(Hg) (mg/l)
Chromium (mg/l)
Lead (mg/l)
Collection & Analysis of following water samples as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified :--
Reservoir Water Sample before confluence point of plant discharge (01 no. sample)
Reservoir Water Sample at 100 mtr from confluence point of Once through condansor cooling system (01 no. sample)
Ground Water Samples at distance of 10 km from power house in four directions (04 nos. Sample) Total 06 Nos. Samples for following:-
pH/Temp.(0C)
Total suspended solids (mg/l)
Oil & Grease (mg/l)
TDS (mg/l)
BOD & COD (mg/l)
Turbidity (NTU)
Total Hardness (mg/l)
Copper (mg/L)
Iron (mg/l)
Chromium (mg/l)
Cyanide (mg/l)
Fluoride (mg/l)
Cadmium(mg/l)
Lead (mg/l)
Arsenic(mg/l)
Mercury (mg/l)
Titanium (mg/l)
Zinc (mg/l)
Dissolved Oxygen (mg/l)
Carbonates (mg/l)
Bicarbonates (mg/l)
Sulphates (mg/l)
Chlorides (mg/l)
Alkalinity (mg/l)
Sodium (mg/l)
Potassium (mg/l)
Collection & Analysis of treated Effluent of Effluent Treatment Plant (ETP), as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
Oil & Grease (mg/l)
TDS (mg/l)
BOD3 days 27oC & COD (mg/l)
Dissolved Oxygen (mg/l)
Chlorides (mg/l)
Collection & Testing of 03 Nos. Peizometer well point Samples, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
pH/Temp. (0C)
Total suspended solids (mg/l)
Oil & Grease (mg/l)
TDS (mg/l)
BOD & COD (mg/l)
Turbidity (mg/l)
Total Hardness (mg/l)
Copper (mg/l)
Iron (mg/l)
Chromium (mg/l)
Cyanide (mg/l)
Fluoride (mg/l)
Cadmium (mg/l)
Lead (mg/l)
Arsenic (mg/l)
Mercury (mg/l)
Titanium (mg/l)
Zinc (mg/l)
Dissolved Oxygen (mg/l)
Carbonates (mg/l)
Bicarbonates (mg/l)
Sulphates (mg/l)
Chlorides (mg/l)
Alkalinity (mg/l)
Sodium (mg/l)
Potassium (mg/l)
Collection & Analysis of D.M. Plant Effluent, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
Temp.(0C)
Total suspended solids (mg/l)
Oil & Grease (mg/l)
TDS (mg/l)
Alkalinity (mg/l)
Copper (mg/l)
Iron (mg/l)
Collection & Analysis of Industrial Drain Samples - 05 Nos. Boiler Blow Down & 05 Nos. Condenser Cooling Discharge, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, Total 10 nos. samples for following:-
pH/Temp.(0C)
Total suspended solids (mg/l)
Oil & Grease (mg/l)
TDS (mg/l)
Alkalinity (mg/l)
Copper (mg/l)
Iron (mg/l)
Collection & Testing of Domestic Water Sample before & after treatment including bactereological testing for E. Coli & Total coliform bacteria, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified. Total 02 Nos. samples.
NOISE POLLUTION
Noise Pollution Monitoring Inside & Outside the Power House at following locations as below:-
Near Turbine
Near Boiler
WT Plant
PF Mill Area
Crusher House
Coal Handling Plant
Ground floor near condenser
Office area in power house
Colony area
Hospital area
All four directions at 10 km redius around the power house
Collection and analysis of used oil (Lubricating oil, Transformer oil & fire resistance fluid (FRF) oil, as per schedule -V of Hazardous & other waste (Management & Trans-boundary Movement) Rule-2016 for the following parameters:-
Polychlorinated Biphenyl (PCBs)
Lead (PPM)
Arsenic (PPM)
Cadmium+chromium+Nickel (PPM)
Polyaromatic Hydrocarbons (PAH) %
VARDAN ENVIROLAB
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .