| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L1 | Accepted-AOC ELIGIBLE | |
| 2 | L2₹49.0 L+₹47,254.50 (0.97%)Rejected-AOC 43 MANAK BHAVAN FIRST FLOOR GUMANPURA KOTA 324 007 RAJASTHAN | KOTA | KOTA | RAJASTHAN | 324007 | L2 | Rejected-AOC ELIGIBLE | |
| 3 | L3₹53.4 L+₹4.9 L (10.0%)Rejected-AOC | L3 | Rejected-AOC ELIGIBLE | |
| 4 | Rejected-Technical | - | Rejected-Technical Two class below than eligible class |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
19 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
REPAIRS TO ROOF AC SHEET TANK CLEANING REPLACEMENT OF TANKS AND CLEANING AND REPAIR TO HANGAR ROOF VALLEY GUTTER TRANSLUCENT SHEET REPAIR TO PLINTH PROTECTION RCC WORK CHAJJA CUPBOARDS PLASTER AND OTHER MISC WORKS IN RAKSHANAGAR IN AFS OJHAR
2023_MES_579242_2
80565
Open Tender
Civil Works
Item Rate
270 days
GE AF Ojhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF OJHAR
₹1.1 L
10 Jul 2023
21 Apr 2023
26 May 2023
21 Apr 2023
19 May 2023
5 May 2023
Amount
Cleaning of old RCC/PVC water tank of capacity exc1000 litres but n. exc. 2000litres, removing all scale and dirt using detergent powder and bleaching powder etc from tanks and from mouth of pipe etc, and hoisting if required and reconnecting to the pipe and writing of cleaning date on tank with paint after removing the old cleaning date complete all as specified & as directed.
Cleaning of old RCC water tank of capacity exc. 5000 litres but n. exc. 8000 litres, removing all scale and dirt using detergent powder and bleaching powder etc from tanks and from mouth of pipe etc, and hoisting if required and reconnecting to the pipe and writing of cleaning date on tank with paint after removing the old cleaning date complete all as specified & as directed.
Cleaning of old PVC water tank of capacity exc.250 litres but n. exc. 500 litres, removing all scale and dirt using detergent powder and bleaching powder etc from tanks and from mouth of pipe etc, and hoisting if required and reconnecting to the pipe and writing of cleaning date on tank with paint after removing the old cleaning date complete all as specified & as directed.
Cleaning of old PVC water tank of capacity exc.500 litres but n. exc. 1000 litres, removing all scale and dirt using detergent powder and bleaching powder etc from tanks and from mouth of pipe etc, and hoisting if required and reconnecting to the pipe and writing of cleaning date on tank with paint after removing the old cleaning date complete all as specified & as directed. Note for Item Nos 1 to 4 : Tank after cleaning shall be shown to the user and got signed by the user and put up to Engr-in-Charge weekly for verification. Any damage to ball cock, float valve, checknuts and any leakage/ any interruption in water supply occured due to negligence of Contractor the same shall be rectified by the Contractor and nothing shall be paid extra on this account.
Disconnecting existing PVC water tanks of any description, of capacity exc. 250 litres but n. exc. 500 litres, setting aside for cleaning etc. and hoisting if required reconnecting and re-fixing in position complete all as specified & as directed.
Disconnecting existing PVC water tanks of any description, of capacity exc. 500 litres but n. exc. 1000 litres, setting aside for cleaning etc. and hoisting if required reconnecting and re-fixing in position.complete all as specified & as directed.
Disconnecting existing PVC water tanks of any description, of capacity exc. 1000 litres but n. exc. 2000 litres, setting aside for cleaning and removing all scale and dirt using detergent powder and bleaching powder etc, and hoisting if required, reconnecting and refixing complete including ball valve in position and writing date of cleaning on tank with paint after removing the old cleaning date complete all as specified & as directed.
Supply and fixing in repairs 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed
Supply and fixing in repairs 1000 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed.
Supply and fixing in repairs 15 mm bore float valve of high pressure PTMT with epoxy coated aluminuim rod and high density plastic ball screwed for iron pipe and fixed in tank which situated up to 15 m height building including necessary ladder for climbing if required complete all as specified and as directed.
All as per item No.10 above but 20 mm bore
All as per item No. 10 above but 25 mm bore
Supply and fixing in repairs gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed to bore dia of pipe in 15 mm, complete all as specified and as directed.
Supply and fixing in repairs gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed to bore dia of pipe in 20 mm, complete all as specified and as directed.
Supply and fixing in repairs gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed to bore dia of pipe in 25 mm, complete all as specified and as directed.
Taking down steel tubing of 15 mm dia bore and connections from walls and ceilings or laid in floor including cleaning for refixing, complete all as specified and as directed.
Taking down steel tubing of 20 mm dia bore and connections from walls and ceilings or laid in floor including cleaning for refixing, complete all as specified and as directed.
Taking down steel tubing of 25 mm dia bore and connections from walls and ceilings or laid in floor including cleaning for refixing, complete all as specified and as directed.
Supply and fix Galvanised Iron tubes 15 mm dia medium grade with all fittings and fixtures such as bends, elbows, tees, short pieces, back nuts, connectors, diminishing pieces, caps, pegs and clamps union etc. laid in wall/floor/ceiling as in concealed work including cutting chases in wall and making good surface complete all as specified and as directed.
Supply and fix Galvanised Iron tubes 20 mm dia medium grade with all fittings and fixtures such as bends, elbows, tees, short pieces, back nuts, connectors, diminishing pieces, caps, pegs and clamps union etc. laid in wall/floor/ceiling as in concealed work including cutting chases in wall and making good surface complete all as specified and as directed.
Supply and fix Galvanised Iron tubes 25 mm dia medium grade with all fittings and fixtures such as bends, elbows, tees, short pieces, back nuts, connectors, diminishing pieces, caps, pegs and clamps union etc. laid in wall/floor/ceiling as in concealed work including cutting chases in wall and making good surface complete all as specified and as directed.
Re-fixing old serviceable steel tubing 15mm bore and supply of new fittings as required at site and fixed in new or old position (walls, ceiling, floors, etc.) complete all as specified and as directed.
Re-fixing old serviceable steel tubing 20 mm bore and supply of new fittings as required at site and fixed in new or old position (walls, ceiling, floors, etc.) complete all as specified and as directed.
Re-fixing old serviceable steel tubing 25 mm bore and supply of new fittings as required at site and fixed in new or old position (walls, ceiling, floors, etc.) complete all as specified and as directed. Note : Work shall be executed in different locations as per site requirement including in short lengths.
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bituminous primer completely, cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/kerb walls etc including removing of the rubbish to a distance outside MoD land, complete all as specified and as directed. Note : Contractor will not throw the debris from roof and suitable arrangements shall be made to bring down the materials.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including PCC of existing roof, PCC tiles with screed bed and removing the demolished material outside MoD land, complete all as specified and as directed.
Material and labour for providing cement concrete 1:2:4 type B0 (Using 12.5mm graded stone aggregate) as in bed plate/roof kerb/PCC padding and haunching etc all as specified and directed Note : PCC shall be laid in slope and thickness shall be average(minimum average thickness 25mm or as per site requirement for maintaining the slope) as per site including filling in depression by providing concrete bench marks for maintaining the perfect slope to drain out the rain water as directed by Engr-in-Charge. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship.
Material and labour for rendering 15 mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 0.12 litre per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Notes : (i) Water proofing compound shall be measured and paid separately (ii) Plaster shall be laid in slope and thickness shall be average as per site including filling in depression by providing cement mortar bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship.
Material and labour for rendering 5 mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 0.12 litre per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement complete all as specified and directed Note : Water proofing compound shall be measured and paid separately
Material and labour for providing cement slurry @ 3Kg per sqm on existing roof surface before laying PCC/ Plaster, complete all as specified and directed
Supply only Liquid water proofing compound
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of wall with cement mortar 1:3 and after insertion of APP in the groove all specified and directed.
Material and labour for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment as the following:- (a) Bituminous primer @ 0.3litres per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified membrane with minimum wt of 3.0 Kg per square metre (one layer) laid by torch application method. Make: M/S TEXSA Ltd (moply FP) or M/S STP Ltd or ASIAN PAINTS (Hydrostop) or M/s Tikki tar Ltd (Tiki Dan) (c ) Applying two coats of bituminous based aluminium paint @ 0.20 Kg in two coats per square metre over membrane. Note : The overlaps of APP shall be as per SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminous paint applied by brushes only.
Dismantling Asbestos cement /FRP /GI (corrugated, semi- corrugated, etc.) sheets in roof coverings up to height 25M and taking care of earthing strip complete all as specified and directed.
Refixing of CGI corrugated sheets/Ridge/Sides sheets/Gutters with Drill machine and fixed with self taping screws complete all as specified and directed. Note : Contractor shall arrange for climbing upto 16 mtr ht and followed the all safety precautions as per labour law.
Material and labour for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm TCT thick of any colour approved by GE having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with 5 Nos. self tapping screws on each sheet /each support rubber lining and filling of gap with cement mortar in CM 1:4 with wall and sheet up to 16 mtr height complete all as specified and as directed
Material and labour for pre-painted galvalume aluminum zinc coating GI based plain steel sheet (min 750mm width) 0.50mm TCT thick of any colour approved by GE having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for 2 mm thick polycarbonate sheet with both side including top & bottom aluminium to match with the profile of existing roof sheet and EPDM rubber gasket fixed with self tapping screws in roof/wall up to any height, both side UV Proctected complete all as specified and as directed Make : Duratuff/lexon Notes : (i) Any extra accesseries required for fixing of Polycarbonate sheet between Galvalume sheets roofing deemed to be included in quoted rates. (ii) Contractor shall make his own arrangment for climbing and working on hangers up to 16 mtr ht. All safety measures are to be followed by the Contractor as per safety guidlines.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Supply and fix Hand rails, half round or other mild steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shapeas directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
Supply and fix Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, portions framed and hung as gates,inc pintle hinges,stops,hand-made sliding bolts etc and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed
Supply and fix Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed
Dismantling wall/ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
Supply and fix Horizontal level suspended ceiling comprising of GI Clip-in Micro perforated 600x600mm (nominal size) tiles of 12mm thick galvanised steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white colour with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on other side. Tile shall have perforated of hole diameter 2.5mm and open area 16% with linear and diagonal pitch of 5.5mm and 7.7mm respectively along with a border of 10mm. The tile shall be electrostatically polyster powder coated using RoHS compliant powder having coating thickness ranging from 60-80microns. Back side of the tile shall have Soundtex fleece hot pressed mechanically for uniform bonding to achieve NRC up to 0.7 all as per manufactures instructions, complete all as specified and as directed.
Supply & fixing in repair of mineral fibre accoustical ceiling system with fine fissurred tiles regular of size 600mmx600mmx16mm thick on existing frame work complete all as specified and directed.
Supply & fixing in repair 4 mm thick Asbestos cement plain building boards in ceiling, fixed to existing timber framework with screws complete all as specified and directed.
Hacking out of existing PCC and taking down plaster near rainwater spot size 450x450mm and M&L 10 mm thick plaster the surface with cement mortar 1:3 in slope toward rain water pipe spot complete all as specified and directed
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Material and labour for Brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1 : 6, complete all as specified and directed
Labour only for brickwork (except bricks) straight or curved on plan exc 6m mean radius, built in CM 1 : 6, complete all as specified and directed
Material and labour for 15 mm thick cement plaster in CM 1:4 on brick surface finished even and smooth without using extra cement on external surface of wall, complete all as specified and directed.
Material and labour for 10 mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement on internal surface of wall, complete all as specified and directed.
Material and labour for removing of tree roots of any girth and height , shrubs and bushes from wall surface/roof top/chajjas up to 15 M height including repairing of cracks and filling the tree root channels and dismantled areas with chemical/ Acid and render unfit for growth of vegetation on building surface and making good in cement mortar 1:3 and to match the surface with existing finishes including all T&P required and considering all saftey measures to carry out work upto ht 15 mtrs of bldg etc lncluding removal of shrubs up to 50 m distance complete all as specified and directed.
Demolition of reinforced cement concrete in any position like roofs, RCC tanks, floors other than ground floors, beam, staircases, landings, chajjas, projections, facias and similar suspended work, reinforcement cut as required to facilate demolition for portions ordered to be dismanttled up to 15 m height and necessary saftey measures, complete all as specified and directed.
Material and labour for reinforced cement concrete 1:2:4, type B1 nominal mix using 20 mm graded broken stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, shelves and the like complete all as specified and directed.
Material and labour for reinforced cement concrete 1:2:4, type B1 nominal mix using 20 mm graded broken stone aggregate as in chajjas, fins etc complete all as specified and directed. Note for Srl item No 55 & 56: Reinforcement shall be measured and paid separately under relevant item of this schedule.
Use and removal of Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves, slabs including supports edges, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
Material and labour for TMT steel bars 10 mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Taking down cement plaster on brick or stone wall any description including raking out joints, hacking for key, scrubbing down with water etc.compete all as specified as directed.
Material and labour for 15mm thick rendering on brick/concrete surfaces on broken edges of chajjas, facia, slab, roof projectioon and any other brick/concrete surface in patch work in CM 1:4 and finishing fair and even without using extra cement with using 2% Integral water proofing compound by wt of cement compete all as specified as directed. Notes : (i) Water proofing compound will be measured and paid separately under relevant item (ii) Quoted rate shall be deemed to include for work up to four storey building & height upto 15 metre including all safety measures, scaffoldings etc., required for carrying out the work
All as per Srl Item No 60 above but 20mm thick in 2 coats.
Supply only integral water proofing compound
Material and labour for rendering 10mm thick on fair faces on ceiling with cement mortar 1:3 & finished even and smooth without using extra cement compete all as specified as directed
Supply and fix Zinc coated Hexagonal Self taping screw length 65mm with washer fixed to existing hanger roof/wall cladding sheets complete all as specified as directed.
Material and labour for sealing the holes/gaps on existing CGI/ Galvalume sheeting roof/Wall of hangers with 100mm x 100mm Self Adhesive patch over a coat of Techothane - PU White 1mm thick and made leakage proof including cleaning by removal of existing rust etc.all as per manufacturers instruction compete all as specified as directed Make : Tikki tar, Chuoksey, STP or Asian
Material and labour for sealing the holes/gaps on existing CGI/ Galvalume sheeting roof/Wall of hangers with 100mm wide Self Adhesive tape over a coat of Techothane - PU White 1mm thick and made leakage proof including cleaning by removal of existing rust etc.all as per manufacturers instruction compete all as specified as directed Make : Tikki tar, Chuoksey, STP or Asian Notes for Srl Item No 65 & 66 : (i) The work shall be carried out in hangers of 16mtr height. (ii) Existing sheets in hanger is galvalume sheet which contains holes and other misc works in different locations of three hangers. (iii) Being very sensetive location the labourers shall have to move on hanger roofs. contractor will follow every safety norms of labour during the exectuion to avoid any mishap. If any mishaps happen due to non follow of safety norms/ accessories / equipments required, contractor shall be held responisible.
Hacking out old broken glass (any thickness, size, quality or description) from steel frame surrounded, glazing with putty compete all as specified as directed
Supply and fix Rough cast wired glass 6.4mm thick size exc 0.75 Sqm but n exc 1.5 sqm and glazing fixed with provision of MS 'U' clip with nut & bolt, made leakege proof with bitumen based gaskets around the glass at joint of MS frame and fixed with oil putty of strength to with stand with the extreme weather norms in external exposed site complete all as specified and directed Note : Contractor shall make his own arrangment for climbing and working on hangers not exceeding 16 mtr ht.
Material and labour for prevent leakage/seepage from roof shall be cleaned by removing dirt dust etc, all cracks to be treated with suitable crack filling compound and applying two coats of flexible acrylic modified cementitious water proofing system @ 2kg/Sqm at 1mm thickness, Tech force 2K strong of M/s Choksey or URP admixed with cement in 1:1 proportion without water in one coat Dr Fixit or equivalent complete all as specified and directed. Note : The surface Shall be tested with ponding test. If any failure occurs, then the same shall be redone without any extra cost with in 24 Hrs.
Dismantling of Boarding of any description including shutters of existing cup boards complete all as specified and directed
Supply and fix 18 mm thick black board laminated on one side of commercial quality exterior Grade -I fixed with screws as in cup board shutters/shelves and pelmet box etc including lipping/beading all over shutter complete all specified and directed
Supply and fix 40mm width of flaps Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed
Supply and fix fancy type Cup Board knobs for kitchen /drawer shutter complete all as specified and directed
Supply and fix magnetic door lock, Stainless Steel, ISI marked for door shutters of Cup Board and kitchen shutters complete all as specified and directed
Supply and fix in repairs Stainless Steel work, Gde 304 in railing/swimming pool ladder/grab bar including all fittings complete all as specified and directed.
Supply and fix Rubber based door bottom strip with aluminium angle not less than 25x25mm including fixing arrangement with screws properly & all as per manufacturers instruction complete all as specified and directed.
Supply and fixing in repairs ornamental designed pattern type precast cement concrete louvres and jallies, 50mm thick (measured solid) including precast post of standard sections in different geometrical shapes, including all mouldings 1:2:4, type B0 (using 12.5 mm graded stone aggregate) set in CM 1:4 including embedding precast post etc including two coats of exterior emulsion paint over a coat of primer of different colour, pattern as approved, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware , AC or RCC or PVC Pipes) of any dia including all fittings any size all as specified & as directed.
Supply and fix PVC (SWR) pipes 160mm dia single, socketed in any length with rubber ring joints fixed to walls with MS clamps complete all as specified and directed.
Supply and fix PVC (SWR) bends 160mm dia complete all as specified and directed.
Supply and fix PVC (SWR) shoe 160mm dia complete all as specified and directed.
Supply and fix in repairs stainless steel railing and balusters with stainless steel hollow section, Square bars/ any other type of section grade SS 204 required for design as approved including all fabrication, grinding and making edges / fabrication perfectly smooth by buffing, complete all as specified and directed.
Supply and fix in repairs 3.15 mm thick plain, mild steel sheeting, in ridges, hips, valley gutters, drip, funnels make in shape/ design as directed and straight flashings (length and girth as fixed) with grade of Fe 410-W 9gde-E-250) Quality B complete all as specified and directed. Notes : (i) Contractor shall made own arrangement for climbing and working on hangers not exceeding 16 mtr ht. (ii) Dismantling the valley gutter through mechanical cutter ( No welding rod is allowed during cutting/Dismantaling of existing of gutters) on existing place for taking down and follow all safety & fire rules. (iii) 100mm minimum overlap shall be provided at the joints of gutters and welding must be water tight and there shall be no seepage/leakage at joints of gutters. only straight length of the gutters shall be measured for payment
Note : The amount against Schedule of Credit on Page No. 36 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance.
M/s Prem Associates
M/S PRAMOD SURESHCHANDRA AHER
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .