Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.1 LAccepted-Finance 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | 1 | Accepted-Finance 1 | |
| 2 | 2₹6.4 L+₹29,822 (4.85%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance 2 |
Tender Value
₹6.2 L
EMD Value
₹12,339
Closing Date
1 Mar 2024, 12:00 pmClosed
EEE/RZ
EEE/RZ
Construction of Toilet Blocks 1 one for boys and one for Girls at MCP Sultanpuri B-2 2 one for boys and one for Girls at MCP Sultanpuri G-Block (3) one for boys and one for Girls at MCP Sultanpuri P-1 4 one for boys and one for Girls at MCP Sec
2024_MCD_188204_1
EEE-III/RZ/TC/2023-24/29.2
Open Tender
Electrical Works
Item Rate
60 days
EEE/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹12,339
1 Mar 2024
24 Feb 2024
1 Mar 2024
24 Feb 2024
1 Mar 2024
24 Feb 2024
Amount
OD27761/2023-2024:DSR-22 ( 5.2) Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
OD27762/2023-2024:DSR-22(5.15) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD27763/2023-2024:DSR-22 (14.16.1) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD28006/2023-2024:DSR-22 (5.18) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD27764/2023-2024:DSR-22 (7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
OD27992/2023-2024:SR22 (7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. up to 35 sq mm
OD27765/2023-2024:DSR-22 (7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
OD27772/2023-2024:DSR22 (1.8.3)Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD27773/2023-2024:SITC of single phase mono block pump set complete with all accessories workable on 240/415 volt, 50 Hz ac supply a)1.H.P (0.75 W) single phase pump set head from 12 meter suction and delivery 25x25mm
OD27774/2023-2024:SR22 (1.58) Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD27776/2023-2024:Supply of 15"(380mm) Sweep 1400 r.p.m. exhaust fan heavy duty complete with shutter, blade etc. as required
OD27777/2023-2024:DSR-22( 1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep
OD27990/2023-2024:SR22 (1.14.2) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire
OD27781/2023-2024:DSR22 (1.21.1) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.42:Supply of 14/15 Watt LED retrofit lamp suitable for B22 holder
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD27991/2023-2024:DSR-22 (2.3.2) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (b) 8 way Double door
OD27988/2023-2024:DSR-22 (2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
OD27989/2023-2024:DSR-22 (2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)63 A.
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.155.(b):Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 HP (Single Phase)
122.2.156.(a):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 2.5 sq.mm
122.2.159:Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
122.2.154B.(a):Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head.
SRI BALAJI ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .