| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹11.9 L+₹15,631.90 (1.33%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.0 L+₹22,772.40 (1.94%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹12.3 L+₹60,421.40 (5.15%)Rejected-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹12.4 L+₹68,984.90 (5.88%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
1 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 68 2021 22 ADDITION ALTERATION OF BUILDING NO NP 04 UNDER GE(N) UDHAMPUR
2022_MES_499107_1
GE/U(N)-68/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹25,000
Yes
15 Mar 2022
3 Jan 2022
3 Feb 2022
3 Jan 2022
1 Feb 2022
17 Jan 2022
60 days
Amount
M&L for taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in charge
M&L for 15 mm thick rendering on surfaces otherthan fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar 1:6 complete all as specified and directed by Engineer in charge
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar 1:4 complete all as specified and directed by Engineer in charge
M&L for 10 mm thick rendering on fair faces of concrete surfaces, finished even and smooth,as in ceiling in cement mortar 1:4 complete all as specified and directed by Engineer in charge
M&L for demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and directed by Engineer in charge
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection even and smooth with using extra cement complete all as specified.
M&L for dismantling floor hearth or wall tiling including cement mortar bedding removing rubbish off the premises, complete all as specified.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and rough to receive tiles as in floors complete all as specified and directed by Engineer in charge
M&L for Light shade Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick cement mortar 1:4 screed, set and jointed with grey cement slurry & pointed with grout of matching shade, complete all as specified and directed by Engineer in charge
Ditto all as per item 10 above but as in skirting over vertical surfaces & including 10 mm thick cement mortar 1:3 screed, set and jointed with grey cement slurry and pointed in grout of matching shade of tiles complete all as specified.
M&L for dismantling asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and directed by Engineer in charge
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in charge
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover filletscomplete all as specified and directed by Engineer in charge
S&F non asbestos fibre Cement board ceiling 4mm, thick in 600x600mm panel designed ceiling conforming to IS-14862 type B category three incl GI frame work, hold fast, suspenderscomplete all as specified and directed by Engineer in charge
M&L for steel windows and ventilators/box type comprised of tubular frame and shutters made out of 1.58mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed of welded incl 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work, incl other fittings, hinges, handles tarred hold fasts PCC blocks etc incl two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F powder coated aluminium doors air tight anodized frame made of size 100x45mm of sheet thickness 1.5mm with one or more rebate including jointing cleats hinges etc for fixing anodized aluminium door shutter fully paneled )two NOs of panel on each shutter) with 5.5 mm thick tinted plain glass shutter rail made of 80x45mm of sheet thickness 1.5mm (top, bottom, middle and side rail). Single/double leaf side hung type including necessary joint cleats, anodized aluminium fitting/aluminium fitting such as aluminium butt hinges 100mm long 4 NOs on each shutter, aluminium anodized tower bolt 200mm long 3 NOs for each door, aluminium anodized handle 150 mm 2 NOs ‘D’ type for each. Shutter & locking 6 lever of make Harrison one on each door, bottom door spring one on each shutter including hydrullic door closer. All door fitting except cleat shall be Ist marked (size of each door shall be as per site requirement) complete all as specified and directed by Engineer in charge
M&L for taking down shutter without taking out chowkhats exceeding 1.5 sqm but not exceeding 4 sqm complete all as specified and directed
M&L for taking down chowkhats without taking off shutters from the frames ( with shutters) area n.ex 1.5 sqm each complete all as specified and directed by Engineer in charge
M&L for plate girder or single stanchions, built up of one beam of channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections(Fe 410-W(Gde E-250) quality B complete all as specified and directed by Engineer in charge
M&L for two coat of Oil bound distemper over 2 to 3mm thick birla white putty including a coat of primer along with preparation of newly plastered surfaces of wall complete all as specified and directed by Engineer in charge
M&L for two coat of cement base paint over a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and directed by Engineer in charge
M & L for providing Chequred cement concrete tiles 25cm x 25cm x22 mm thick tiles set , jointed and pointed in neat cement slurry in floors with grey cement ant pigment laid over & incl 20 mm thk screed bed in CM 1:4 complete all as specified and directed by Engineer in charge
M & L PCC 75 mm th 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base flooring complete all as specified and directed by Engineer in charge
M&L for complete removal of existing treatment, preparation of surface and applying two coats of oil bound distemper over one coat of wall care putty and primer complete all as specified and directed by Engineer in charge
M & L two coat of cement base paint over a coat of alkali resistant priming paint over old plastered surfaces of wall including preparing surfaces after complete removal of existing treatment complete all as specified and directed by Engineer in charge
S & F 19mm thick pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination , all as per specification commercial type complete all as specified and directed by Engineer in charge
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer in charge
M&L for Reinforced Cement Concrete 1:1½:3, type A-1, using 20 mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4complete all as specified and directed by Engineer in charge
M&L for 8 mm dia and over, mild steel TMT bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed by Engineer in charge
M&L for use & waste of formwork to soffits of suspended slabs such as shelves, roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with rough finished surfaces of concrete, complete all as specified.
M&L for brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified.
M&L for factory made pressed steel frames having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified.
S & F 35mm thick 2nd class H.W plain framed shutters two panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer in charge
M&L for one coat of synthetic enamel paint on old treated wooden surfaces incl preparation of old surface of any description not otherwise described over 10 cm width or girth complete all as specified and directed by Engineer in charge
M&L for one coat of synthetic enamel paint on steel surfaces incl preparation of old surface of any description not otherwise described over 10 cm width or girth complete all as specified and directed by Engineer in charge
S&F 3mm thick sheet glass ordinary quality not exc 0.50Sqm in each pane fixed with oil putty complete all as specified.
S & F 250mm mild steel slding door bolts, plate type, stove enamelled black with bright bolt not lesss than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer in charge
S & F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer in charge
S & F 150 mm , Extruded aluminium ally handles, fabricated type., anodised complete all as specified and directed by Engineer in charge
S&F 100 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed by Engineer in charge
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer in charge
Taking down carefully point wiring copper/aluminium including existing concealed conduit except from junction of wall and ceiling to ceiling fan terminal box(light, fan, socket, and power) complete (fittings such as switches ceiling roses, pendent regtulators sockets etc to be measured and paid for separately removing materials to store for keeping of safe custody and making good the disturbed surfaces complete all as specified and as directed.
M&L for point wiring with PVC insulated unsheathed, FRLS 1100 volts grade stranded copper conductor cable single core 1.5 Sqmm for one light / fan point controlled by one way switch, and wire to be drawn in and including rigid pvc concealed conduit of dia not less tham 25mmof 2mm wall thickness complete with all accessories including GI anealed metal box 1.2 mm thick switch board of suitable size be fixed flush wall , with 3 mm thick ebonite sheet cover and necessary screws, cap washers etc. or to be fixed on wall respectively as directed by EIC and providing earth continuity wire using PVC insulated, un sheathed single core stranded copper conductor FRLS cable of size 1.5 Sqmm.
All as per item No. 45 above but for one 5 Amps socket outlet on independent board.
All as per item No. 45 above but wire size 2x2.5 Sqmm and and providing earth continuity wire using PVC insulated, unsheathed single core stranded copper conductor FRLS cable of size 2.5 Sqmm. to controlled the 3 pin 5 / 15 Amps socket outlet on independent board.
M&L for point wiring with 1.5 Sq. mm copper conductor, single core, PVC sheathed, cable, to controle one 3 pin socket outlet, 5 Amps on the same board with other switch.
S&F Switch Piano, flush type, One way, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Two in one, 3 Pin, 5 Amps, flush type socket outlet complete all as directed by Engineer- in - Charge.
S&F Switch Piano, flush type, One way, single pole, 15 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Two in one, 3 Pin, 5/15 Amps, flush type socket outlet suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as directed by Engineer - in - Charge.
S&F Stepped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc. as required complete all as directed by Engineer- in - Charge.
S&F in replacement E-Lite LED Curve lighting fixture 12 watt LED batten,T5 with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old unserviceable tube light fitting 1x 18 watt from the site reuse to measured seprately or disposal by credit all as per the direction of Engr-in-Charge. Make -Havells as per ordering code in wipro or C&S, Syska cat No SSK-T5-12w or equivalent model of Bajaj/Philips/Surya/CG subject to sample approved by the Accepting Officer
S&F in replacement Ultra modern recess mounting liminiare suitable for armstorng/grid/POP ceiling complete with separate electronic driver with LED 34/36 watt make :- CG cat No LCPL-36-CDL(2X2) or equivalent in Syska cat No SSK-TVP-12030-36W Havells Cat No : PLUTOSURFACE2X2PLS34WLED857S subject to sample approved by the Accepting Officer
Supply and fixing LED Bulk head (6500K) fitting of 9Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by engineer in charge Make : SYSKA equivalent to Havells/crompton greaves subject to sample approved by the Accepting Officer
S&F Slim linear LED lighting fixture 18/20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 36/40W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ syska CAT No CAT NO : SSK RA 1801 subject to sample approved by the Accepting Officer
S&F in replacement security (street) light fitting 25 watt, new generation energy saving & environmental friendly long life versatile pressure die cost aluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver, including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light complete all as per direction of Engr-in-Charge. Make:SYSKA Cat no SSK-ST-25W(SN) or equivalent in CG cat No : LSTS-25-CDL subject to sample approved by the Accepting Officer
S&F for Muziris Picture light flexible neck for adjusting beam bronze finish for superior feel long life life light source of 7W complete all as per direction of Engr-in-Charge Make : Philips Cat No : 31402 or equivallent to SYSKA / WIPRO subject to sample approved by the Accepting Officer
M&L for taking down fan/Exhaust fan, ceiling cable end, dismantling blades and kept in safe custody for repairing/servising complete all as per direction of Engr-in-Charge
M&L for repair of ceiling fan 1200mm sweep/ Exhaust fan of any make obtained from above item, oiling, greasing after cleaning slot, over hauling & replacement of defective split pin nut bolts washer etc including spray painting with enammeled paint with the help of spray gun and marking of MES No with black enammeled paint all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling/Exhaust fan and connecting up including provision of stranded 3core flexible 1.0sqmm copper conductor cable from ceiling rose or connector to fan all as specified and directed by Engr-in-charge.
M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on complition with following:- (a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
M&L for taking down old unserviceable copper / aluminium submain wiring any type / size from existing old surface for further repair / replacement complete all as per direction of Engr-in-Charge
M&L for wiring for circuit / Submain Wiring in PVC surface conduit not less than 25 mm dia with 2 x 06Sq.mm main wire and 1 x 06 Sq.mm earth wire of FRLS, PVC insulated copper conductor, single core cable complete all as directed by Engineer - in - Charge.
M&L for taking down old unserviceable MCB DB with MCB etc after disconnecting for re use or for credit all as directed by engineer in charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as per direction of Engr-in-Charge
Supply and fixing exhaust fans steel body,AC ingle phasee 230 volts of size 300 mm sweep with blades and frame and louver complete all as specified and directed
S & F in replacement single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as per direction of Engr-in-Charge
S&F 'C' series SPN MCB 40 Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting complete all as per direction of Engr-in-Charge
Supply fixing connection and testing MCB SP 6-32 Amps 'C' Curve complete all as per direction of Engr-in-Charge
Supply fixing connection and testing MCB SP 40 Amps 'C' Curve all as specified and as directed by Engineer in charge.
Supply and fix on load change over switch 4 pole 415 V AC, 50 Hz in sheet metal enclosure TPN of capacity 63 Amp all as complete all as per direction of Engr-in-Charge
M&L for taking down all unserviceable aluminium strip complete with insulater and test points all as directed by Engineer in charge.
Supply and fixing of Aluminium strips of size 25x3.15mm complete with fixing by screw and brazing complete for roof conductors/down conductors fixing on porcelain insulators with screws complete all as directed.
S&F test point air terminal block made of gunmetal or phosphorous bronze size 75x75x25 mm drilled and screwed including 3 nos of 8mm dia 25mm long hexagonal head screws complete all as per direction of Engr-in-Charge
S&F single pointed Air termination aluminium rod 12mm dia 300 mm long complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth strip of 32x 6mm by means of GI nuts, bolts and washers. Strip laid in 50mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) Test point GI strip of size 32mm x6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
SupplyIing, laying / fixing and testing in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing complete all as per direction of Engr-in-Charge
M&L for excavation in trenches in any type of soil n exc 1.5m deep and not exc 1.5m wide for laying of under ground cable, electric pole and getting out complete all as directed.
M&L for returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil complete all as per direction of Engr-in-Charge
M&L for removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as per direction of Engr-in-Charge
M&L for dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt complete all as per direction of Engr-in-Charge
M&L for GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as per direction of Engr-in-Charge
M & L for replacement of DB0XX MCB protected socket with sheet steel enclosure complete WITH MCB SP 25Amp all as specified and as directed by Engineer in charge.
S & F sheet metal TPN DBs - DPX3 160 MCCB DBs 4 way (DPX3 160+ 12) with metal door 415 volts grade IP 43 Protection Grade fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge
S & F and connecting with necessary copper lugs DPX3 thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 KW INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.
joginder singh and sons
M/S JANDIAL ENTERPRISES
TULSI RAINA AND SONS
SATYA SALES AND BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .