| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.3 L+₹36,106 (2.26%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.6 L+₹70,256 (4.41%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Jun 2023, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-31/2023-24 REPAIR/MAINT OF AIR CONDITIONING, REFRIGERATOR, WATER COOLER AND OTHER COOLING APPLIANCES AT AF STN PALAM UNDER GE (AF) GURGAON NO 1.
2023_MES_595365_1
GE AF No 1/GUR-31/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹50,000
Yes
30 Jun 2023
15 May 2023
15 Jun 2023
15 May 2023
13 Jun 2023
30 May 2023
Amount
Servicing of window type AC 1.5/2 TR capacity including oiling greasing of fan motor replacement of synthetic filter & checking of electric circuit for smooth functioning of AC (S&F of unserviceable burnt spare parts of machine shall be meaured and paid for separately under repsective items) complete all as directed. (Items such as welding rod, LPG can & Brazing rod for welding , nitrogen leak testing etc. included in this item).
All as per item No 1 above but split AC of 1.5/2 TR-ditto-.
Supply & fixing in replacement of starting relay suitable for 1.5 TR/2TR capacity AC complete all as specified and directed. make: Classic/Renutrol or equivalent as specfied
S&F in replacement of over load protector suitable for 1.5/2.0 TR capacity -ditto-. Make: Classic/Renutrol or equivalent as specfied
S &F in replacement of starting capacitor 60+6/ 60 mfd suitable for 1.5 ton capacity AC complete all as specified and directed. Make:- Tesla/Usha/GDR/Tibcon/EPCOS or equivalent as specfied
S&F in replacemernt of capacitor 55+6/ 55 mfd suitable for 1.5 ton capacity AC complete all as specified and directed. Make: Usha/Asian/Tibcon/EPCOS
All as per item No 6 above but 50+6/ 50 mfd suitable for 1.5 ton capacity- ditto-.
All as per item No 6 above but 45+6/ 45 mfd suitable for 2.0 ton capacity -ditto-.
All as per item No 6 above but 36+6/ 36 mfd suitable for 2.0 ton capacity ditto-.
All as per item No 6 above but 1/2 to 6 mfd suitable as per site requirement ditto-
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity /Window AC complete all as specified and directed
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity Split AC complete all as specified and directed
S&F in replacement of thermostate switch suitable1.5/2 Ton capacity AC complete all as specified and directed
S&F in replacement of front grill suitable for 1.5/2.0 TR capacity of window AC complete all as specified and directed.
All as per item No 14 above but base plate suitable for 1.5/2.0 TR capacity of window AC complete all as specified and directed
S&F in replacement of metal clad socket 20 Amp complete all as specified and directed Make; Crompton/Havells/Philips or equivalent as approved.
All as per item No 16 above but metal clad plug complete all as specified and directed. Make Crompton/Havells/Philips
Taking out unserviceable fan-cum-blower motor and M&L for rewinding and repairing of fan-cum-blower motor of window tpe AC 1.5/2.00 TR capacity with supper enamelled copper winding wire of existing gauge complete all as specified and directed by Egnineer-in-charge
All as per item No 18 above but fan motor for split type AC 1.5/2.0 TR -ditto-
All as per item No 18 above but blower motor for split type AC 1.5/2.0 TR -ditto-.
S&F new reciprocating type compressor of capacity 1.5 TR in replacement to unserviceable compressor complete all as specified and directed. Make: Emerson copeland/Tecumesh /Carrier. Note:- Charging of gas shall be paid separately undre respective item of schedule)
All as per item No 21 above but capacity 2.0 TR -ditto-.
"S&F new fan-cum-blower motor with propeller, fan blade, rubber seal, holding clamps nuts & bolts for 1.5/2 TR window AC in replacemnt to unserviceable motor complete all as specified and directed. make AUE/ANU/GE Motors/Marathan
S&F new blower blade for 1.5/2 TR window AC in replacement of old unserviceable fan blade complete all as specified and directed.
S&F new fan blade for 1.5/2 TR window/split AC in replacement of old unserviceable fan blade complete all as specified and directed.
S&F new blower for 1.5/2 TR split AC in replacement of old unserviceable blower complete all as specified and directed.
Supply & charging the refrigerant gas R-22 to window/split type AC upto 2 TR capacity including test complete all as specified and directed
Supply & charging the refrigerant gas R-410A to split type AC upto 2 ton capacity including testing complete all as specified and directed by Engr-in-charge
Supply & charging the refrigerant gas R-32 to split type AC upto 2 ton capacity including testing complete all as specified and directed by Engr-in-charge
S&F in replacement of MCB 20 to 32 Amps cap 230 volt AC supply complete all as specified and directed. make: MDS/Havells or equivalent
Supply & fix sheet metal single pole and neutral enclosure with a two pin and earth plug and socket compelte with one signle pole MCB 20 Amps Make: Havells/Crompton or equivalent
S&F new rotary type compressor of capacity 1.5 TR suitable for working on R-22 Refrigerant in replacement to unserviceable compressor complete all as specified and directed. make: Mitsubhishi/Tech mesh product/LG Hitach (Charging of gas shall be paid separately/under respective item)
All as per item No 32 above but 2.0 TR -ditto-.
S&F new rotary type compressor of capacity 1.5 TR sunitable for working on R-410 A refrigerant in replacment to unserviceable compressor Make: Mitsubishi/Techmesh/LG/HiTachi/Carrier (Charing of gas shall be paid separately under respective item)
All as per item No 34 above but capacity 2.0 TR -ditto-.
Supply & fix in replacement new inverter type PCB card suitable for 1.0/1.5/2. 0 TR capacity of split ACs including suitable for invertor AC's of said capacity all as specified and directed
M&L for repairing of inverter PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and directed
M&L for repairing of PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and directed
Supply & fix in replacement new swing motor suitable for 1.5/2.0 TR capacity of window/Split AC complete all as specified and directed
Supply & fix in replacemnt of PVC drain pipe 15mm dia with fittings and fixing accessories complete all as specified and directed
S&F reverse valve suitable for split type AC 1.5/2.0 TR including additional copper tubing of any size brazing work, presure testing dehydration gas charging upto required level and necessray modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and directed
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigerant in replacement of old unserviceable condenser. Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule
All as per item No 42 above but split type AC's -ditto-.
S&F condensor with copper tubing and aluminium fins suitabel for 1.5/2.0 TR window type AC suitable for working on R-410A refriegrant in replacement of old unserviceable condenser. Note: Supply & filling of refrigerant gas shall be measured and paid separately under respective item of this schedule
All as per item No 44 above but split type AC's
Taking out old perished insulation and M&L for insulating the suction and discharge copper tubing from indoor unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed
Taking out old unserviceable copper tubing and M&L for suction and discharge copper tubing in replacement of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre.
All as per item No 47 above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5mm thickness
Taking out old unserviceable suction line valve assy of size 1/2" dia from outdoor unit of split tpe AC and S&F new suction including soldering and braizing all as specified and directed
All as per item No 49 above but discharge valve assy size 3/8" dia
S&F PVC flexible pipe inclusive of all clamps (40mm, 32mm, 28mm, 16mm, 10mm), tie belt (10inch, 12 inchs) and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed
S&F in replacement electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5sqmm 4 core, complete all as specified and directed Make: National/Havells/Kalinga/Plaza
S&F in replacement electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 4 sqmm 4 core, complete all as specified and directed. Make: National/Havells/Kalinga/Plaza or equivalent as specified.
Supply & fix AC stand wall mounted/floor mounted type suitable for existing type/Model of AC's complete all as specified and directed by Engr-in-charge
M& for shifting of window/split AC's from existing loaction into New location dismantling of window/split AC's with electrical connection carefully and transported to New location as directed by the Engr-in-charge and cutting of window grill /brick wall including making good patches both the location & servicing of said AC's including point wiring suitable for window/split AC's not less than 215 sqmm (copper conductor and fixing of plg for window AC's remaining area complete all as specified and directed by Engineer-in-charge
Supply & fix in replacement of indoor unit suitbale existing type capacity of split AC's complete all as specified by Engr-in-charge (1.5/2TR) all as specified and directed Make: Voltas/LG/Hi-Tachi or equivalent as specified.
M&L for one 3 pin socket outlet 15 amps independent with cabes 4 Sqmm size complete all as specified and directed by Enginer-in-charg
REFRIGERATOR
Supply & fix new compresor 1/8 HP suitable for refrigerator of capacity 165 to 200 ltr in replacemnt of burnt defective compressor. The work includes taking out the defective compresor and tsting on completion all as specified and directed. Make: Techumesh/LG/Whirlpool. Note: (a) Charing of gas R-134 and shall be paid separately under respective item
All as per item No 58 above but refigerator capacity 220 to 400 ltrs -ditto-.
S&F in replacement of evaporator cooling coil of rferigerant 165 to 400 ltrs capacity complete all as speciifed and directed by Egnineer-in-charge
S&F in replacement of evaporator cooling coil of refrigerant 220 to 400 ltrs capacity complete all as specified and directed
S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size (Make Hitech/Renturol or equivalent
S&F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and directed
Taking out existing old rusted bottom body and frame door form refrigerator & M&L repariing of any size & capacity or refrigerator body bottom and frame door with mild steel flat, angle iron & plain GI sheet of existing gauge by electric welding incuding preparation of surface and painting with spray paint on steel and iron surface of approved make shall be used complete all as specified and directed
M&L for spray painting of refrigerator of any size make with synthetic enamelled paint (GUCCO Delux paint) 2 coat over existing surface. The work includes surface preparation filling of damaged portion complete all as specified and directed
Taking out burnt defective compressor 1/3 HP from deep freezer of capacity upto 425 ltr & S&F new compresor 1/3 HP capacity suitable for deep freezers 425 ltrs capacity of make Kelvinator/Ashoka including dehydrating of system and charging of comp oil & refeigerant gas complete all as specified and directed Make: Kirloskar/Techumesh)
S&F in replacement of exhaust condensor motor for deep freezer of capacity upto 425 ltr as specified and directed.
S&F in replacement of thermostatic switch for refrigerator of any make and 165 to 400 ltrs capacity all as specified
Spply & fix in replacemnet door gasket suitable for refrigerator of capacity 165 to 400 ltr single door
Supply & fixing Hydrocarbon Can(400-600ml) gas in refrigerator of capacity 165 to 400 ltrs complete including testing all as specified and directed
Supply & fixing R-134A Can(400-600ml) gas in refrigerator of capacity 165 to 400 ltrs complete including testing all as specified and directed
Supply & fixing R-600 Can(400-600ml) gas in refrigerator of capacity 165 to 400 ltrs complete including testing all as specified and directed
Supply & charging the refrigerant gas R-134A in deep freezer of capacity 200 to 425 ltrs including testing complete all as specified and directed
(WATER COOLER)
Servicing and cleaning of water cooler 40 to 80 ltr capacity form inside and outside with potassium permaganatse including servicing of fan motor, condensoer, fan balde and ite connected water and refrigerant fitting (S&F of spare parts required for smooth fuctioning of the machine shall be measured and paid for separately under respective items), testing water tank leakage complete all as specified and directed
All as per item No 74 above but capacity 120 to 150 lts
S&F new compressor in replacement suitabel for 40 to 80 ltrs capacity water coolers any make> Re-fixing on its origianl position and testing for smooth functioning. Note: (1) Supply & charging of gas R-22/R-1348 shall be paid separately under respective item.
All as per item No 76 above but capacity 120 to 150 ltrs -ditto-
M& L for charging refrigerant gas R-22 in the water cooler of any make 40 to 80 ltrs capacity including testing and detecting leakage with nitrogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 78 above but capacity 110 to 150 -ditto-.
M&L for charging refrigerant gas R-134A in the water cooler of any make capacity 40 to 80 ltrs including testing and detecting leakage with nirogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 80 above but capacity 120 to 150 ltrs -ditto-
S&F in replacement of overload relay box tyupe make shriram/renutrol suitable for water cooler complete all as specified and directed by Engineer-in-charge
S&F in replacement of thermostat switch make Danfoss/Renutrol suitable for water cooler of any make and size complete all as directed by Engineer-in-charge
S&F in replacement of starting relay suitable for water cooler make: Usha/Sriram/Renutrol/Classic all as specified and directed by engineer-in-charge
S&F in replacement of overload relay make: Classic/Renutrol No 1022/522 complete all as specified and directed
M&L spray painting of water of cooler of any make 40 to 80 ltrs capacity as per existing coloru (after scraping the old damaged paint making good to the disturbed surface to match with the existing surface) and shade with synthetic enamelled complete all as specified and directed
All as per item No 86 above but capacity 120 to 150 ltr -ditto-.
S&F in replacement of defective push cook 15mm dia chromium plated heavy duty suitable for water cooler of any make capacity complete all as specified and directed by Engineer-in-charge
S&F in replacemnt fo PVC float valve assembly 15mm dia for water cooler of any make 40 to 80 lotrs capacity complete all as specified
S&F in replacement of PVC float valve assembly 15mm dia for water cooler of any make 120 to 150 ltrs capacity complete all as specified and directed
S&F in replacement of running capacitor 25 mfd complete all as specified and diirected by engr-in-charge. Make: Usha/Tibcon/Havells
S&F in replacement of running capacitor 30 mfd complete all as specified and diirected by engr-in-charge. Make: Usha/Tibcon/Havells
M& L in replacement of water cooler base including fabrication with angle iron frame, bottom base MS sheet of 15 gauge including welding brazing repalcemnt of MS hinge half swing of top cover, top gasket all as sper site eqauriement incuding paitning a coat of red oxide primer) as directed by Enginer-in-charge
S&F in replacemtn electric cable PVC insulated rubber sheathed circular copper conductor of size 2.5 sqmm single core, Make: National /Havells/Kalinga/Plaza or equivalent
S&F in replacemtn electric cable PVC insulated rubber sheathed circular copper conductor of size 1.5 sqmm single core, Make: National /Havells/Kalinga/Plaza or equivalent.
S&F new fan motor suitable for water cooler of capacity 40 to 80 ltrs complete all as specified and directed
All as per item No 96 above but capacity 120 to 150 ltrs -ditto-
S&F in replacement of aluminium fan blade suitable for 40 to 80 ltrs of water cooler all as specified and directed .
All as per item No 98 above but capacity 120 to 150 ltrs -ditto-.
S&F in replacement of condenser copper tubing with aluminium fins suitable for 40 to 80 ltr capacity water cooler complete all as specified and directed.
All as per item No 100 above but capacity 120 to 150 ltrs -ditto-.
(DESERT COOLER)
M&L for cleaning of water tank of desert coolers and cleaning of side panels with steel wire brush scratching old paint from complete desert cooler externally and internally and painting of the same with synthetic enamel paint (ash/hammerton epint) one coat extrernally with spray painting and with a coat of wate resistance paitn inside over a suitable primer coat incl replacement of internal wiring of suitable size complete all as specified and directed
Taking down existing unserviceable fan copper motor assembly complete with blades mounting frame leg with rubber bush from desert coolers and S&F motor assembly complete with blades, mounting frames legs with rubber bus for desert cooler of capacity 3000/4000/50000 cum hrs and testing complete all as specified and directed by Engineer-in-charge (Make Usha, Crompton, Khaitan).
M&L for replacement of unserviceable /burnt submersible pump for desert cooler suitable for operation on 230 volts AC supply of capacity 18 watt complete all as specified and directed by Engineer-in-charge. (Make USHA, Crompton, Khaitan).
Taking out with nylon threads suitable for any make of desert cooler and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum maximum capacity 3000 cum/hr to 5000 cum hrs incuding S&F iron with PVC insulated protective guards for holding the wood pads firmly complete all as specified and as directed.
S&F body in replacement of desert cooler 4000 cum/hrs capacity made out of galvanized iron sheets with bottom tank of 18 gauges, top cover of 20 gauge and side panels of 23 gauge GI sheet duly fitted with 1/3" thick woold wool pads including heavy duty 22 gauge frame grill burried with one piano type amps complete all as specified and directed
All as per item No 106 above but 3000 cum/hr capacity -ditto-
S&F side panels for desert cooler of capacity 3000 cum/hr made with 22 gauge GI sheet complete all as specified
S&F side panels for desert cooler of capacity 4000 cum/hrs made with 22 gauge GI shet complete all as specified and directed
S&F side panels for desert cooler of capacity 5000 cum/hrs made with 22 gauge GI sheet complete all as specified
S&F in replacement of PVC water distribution system of desert coolers complete with PVC elbow, PVC pipe heavy duty 15mm dia all as directed
S&F in replacement of 15mm float valve PVC complete all as specified Make: Prayag/Polytuff or equvalent as specified.
Taking out the existing desert cooler from ground/1st floor for repairs & fixing only of desert cooler at ground/1st floor after servicing/repair at required position as including painting complete of existing MS angle iron stand as per existing colour all as directed and complete all as specified and directed.
S&F in replacement electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 1.00 sqmm 3 core, Make: National /Havells/Kalinga/Plaza or equivalent.
S&F GI tubing 15mm bore in ground/1st floor with its connected fittings such as the elbows, nipple and as directed by Engineer-in-charge
S&F in replacement of PVC stop cock 15mm complete all as directed by Engineer-in-charge. Make: Prayag/Polytuff or equivalent as approved.
S&F in replacement of PVC connection 600mm long complete all as directed by Engineer-in-charge. Make: Prayag/Polytuff or equivalent as approved.
S&F in replacement of PVC connection 900mm long complete all as directed by Engineer-in-charge. Make: Prayag/Polytuff or equivalent as approved.
S&F in replacment of switch point 5 Amps, complete all as directed by Engineer-in-charge.
S&F in replacement of plug top 5 Amps, complete all as directed by Engineer-in-charge. Make: Anchor/Kinjal/Sanico or equivalent as approved.
All as per item No 122 but 15 Amps Make-Anchor/Jindal/Sanico or equivalent as approved.
M&L for opening, dismantling, tracing the faults, repairing, servicing and re-assembling the voltage stabilizer suitable for 230 volts 50 Hz, AC supply single phase of capacity 4/5KVA complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of transformer complete with super enamelled copper winding wire of same gauge including varnishing, draying, insulating complete for voltage stabilizer 4/5 KVA capacity suitable or working 30 volts, 50 Hz AC supply complete all as specified and directed by Engineer-in-Charge.
All as per item No. 125 above but replacement of electromagnetic power relay A-50, 24 volts series SR complete all as specified and directed by Engineer-in-Charge.
All as per item No. 125 above but replacement of voltmeter (0-300) volts of Make as per existing complete all as specified and directed by Engineer-in-Charge.
All as per item No. 125 above but replacement of PCB as per existing make complete all as specified and directed by Engineer-in-Charge.
All as per item No. 125 above but replacement of input & output connection terminal plate complete all as specified and directed by Engineer-in-Charge.
1. The contractor shall provide and deploy sufficient technician with helpers (as approved by GE / Engineer-in-charge) for maintenance of summer appliances at all Units and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints & complete the same complaint detailed by JE E/M /Engineer-in-charge with in 24 hrs.2. The complaints shall be rectified with in 24 hrs. If the complaints is/are not complited on same day (except repair/ replacement of major items like repair/ replacement of compressor, cooling coil, condensing coil, fan motor ducting work of AC plant & insulation work. these work can be completed in time period (max 36 Hrs) as decided by Engineer-in-charge after which recovery shall be made as under), the recovery will be done as follows. (a) After 24 Hrs Rs - 1000.00 Per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station PALAM.
Note:- The amount of Rs 1,27,358.00/- against Schedule of Credit on Page Nos 123 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S Anand Enterprises
Sumit Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .