Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L3₹9.8 L+₹1.6 L (18.9%)Rejected-Finance 02 SIDDHANT RESIDENCY NEAR AMBAD POLICE STATION SINHASTHA NAGAR CIDCO NASHIK MAHARASHTRA 422009 UDYAM MH 23 0069304 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹11.9 L+₹3.7 L (44.3%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹22,300
Closing Date
16 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL DHANU KUMAR RAI
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
REPAIR AND MAINTENANCE OF RUNWAY PERIMETER LIGHTS AND CABLE, CONTROL PANEL BOARDS AND ERTHING AT TECHNICAL AREA AT ICGAS DAMAN
2023_MES_589723_1
8669/E8
Open Tender
Civil Works
Item Rate
180 days
ICGAS DAMAN
Class E and Category b(i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹22,300
8 Aug 2023
18 Apr 2023
18 May 2023
18 Apr 2023
16 May 2023
2 May 2023
Amount
Supply and fix LED street light fitting 25 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed. Make:-Philips model No.BRP042 LED25 CW SLE S1 PSU GR P4210 or equivalent make in Crompton/Bajaj/Havells/ Halonix
Supply and fix GI bracket made out of 32 mm dia GI pipe, medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces. The bracket pipe shall be welded to the MS strip of size 32mmX 5mm thick at three places for purpose of giving strengthening to the bracket pipe and fixing with necessary suitable nuts,bolts & washers and removing of old unserviceable item complete all as specified and directed. Make of GI pipe:- Jindal/Tata/BST
Supply and fix FRP looping box of size out side (230x170x105mm) and inside (200x140x95 mm), connector and comprising of MCB SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall etc and including removing old unserviceable item complete all as specified and directed. Make:- FRP Box- National/Sintex, MCB SP- Havells, Legrand, ABB, Schneider
Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;2.5 sqmm and including connection and testing inlcuding removing old unserviceable item complete all as specified and directed. Make:-Havell/Finolex/Plaza/Polycab
Supply, lay and testing LT cable XLPE insulated, galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 185 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. Note for item No 5 to 8: Excavation/Earth work, sand cushioning, cable cover, protection pipe shall be measured and paid separately Make for item No 5 to 8:- Havells/Finolex/Polycab( ISI Marked)
Supply,lay and testing LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 50 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. .
Supply,lay and testing LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 16 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply,lay and testing LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 10 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum depth, height, width of panel is 450x1800x1500 mm respectively, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :- (a) MCCB 200 Amps,FP, 36 KA,415 volts,50Hz- Incomer (b) MCCB 100 Amps,FP, 25 KA,415 volts,50Hz-02 Nos (c) MCCB 63 Amps,FP, 16 KA,415 volts,50Hz- 02 Nos (d) MCB 63 Amps,FP,10 KA,415 volts,50Hz-02 Nos (e) Digital, voltmeter,Ammeter,with CTs,VSS & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating -01 set Note:- (i) contractor shall provide CPRI certification of the panel. (ii) Make for MCCB :-Schneider/L&T/Legrand/Standard (ISI Marked) .Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25X 4 mm from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation/earth work in any strata and returning filling, removal of surplus soil and testing for required value including removing unserviceable item complete all as specified and directed.
Supply and lay GI pipe 50mm dia light grade in any lenght with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of airfield lighting cable and electric cable including removing old unserviceable item complete all as specified and directed.
Supply and lay GI pipe 80mm dia light grade in any lenght with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of airfield lighting cable and electric cable including removing old unserviceable item complete all as specified and directed. Make for item No. 11 & 12 :- Jindal/Tata/BST/Hindusthan
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth; for laying of cables, protection pipes and foundations etc. and getting out in any soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying reinforced precast concrete cable cover,class LV, Type 1, flt, size 250mmx150mmx40mm complete all as specified and directed
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches upto 23 cm and punning to 18 cm to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for payment purpose.
SHRI SULAI ELECTRICALS
Harsh Infrastructure
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .