Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹45.7 L+₹7.6 L (19.8%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹47.9 L+₹9.7 L (25.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
22 Oct 2022, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
Special Repairs to Bldg No P-3 and P-4 (MT Shed), T-73 (ASC), Ceiling Fans and Street Light at Aurangabad under GE (S) Ahmednagar
2022_MES_553853_1
8910/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Aurangabad
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹97,600
Yes
14 Nov 2022
23 Sept 2022
24 Oct 2022
23 Sept 2022
22 Oct 2022
8 Oct 2022
23 Sept 2022 - 30 Sept 2022
Amount
Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc 15 cm thickness, (above or below ground level) all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles all as specified and as directed.
Taking down chowkats or frames, area n.exc 1.5 Sqm each (without taking off shutters from frames) all as specified and as directed.
Taking down chowkats or frame, area exc 1.5 Sqm but n.exc 4.00 Sqm each (without taking off shutters from the frames) all as specified and as directed.
Taking down trusses etc., any type and size of wooden/steel members, above 4m upto 8m span all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and as directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position all as specified and as directed.
Dismantling stone slabs/Cudappah/Kota stone slab of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar all as specified and as directed
Taking down cement or cement lime plaster on brick/stone walls etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Excavation in trenches, n exc 1.50m wide and n exc 1.50m in depth; for foundations, etc. or for manholes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil all as specified and as directed.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and as directed.
Removing excavated soil to distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed.
M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6, type C1 (using 20 mm graded aggregate) as in filling back of chowkats, hold fast blocks, bed blocks and like complete all as specified and as directed.
M&L for pre-cast reinforced cement concrete, 1:2:4, type B-1, using 20 mm graded stone aggregates as in manhole cover slabs and the like including necessary forms, moulds etc and finishing concrete surcace even and smooth without using extra cement complete all as specified and as directed. Note : Reinforcement shall be measured and paid seperately.
M&L for applying one coat of epoxy Zinc primer (DR. FIXIT or equivalent make) to existing reinforcement bars of columns, beams and slab and applying one coat of bonding agent (DR FIXIT Pidicrete MPB or equivalent make) mixed with cement (ratio 1:1) and finally levelling with DR FIXIT (or equivalent make) Polymer mortar PX mortar including removing loose concrete portions of columns, beams and slab carefully, cleaning thoroughly by making the surfaces free from dust, rust etc complete all as specified and as directed.
M&L for brick work with old size,fly ash bricks, straight or curved on plan exc 6m mean redius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
S&F 35mm thick second class hardwood factory made, plain, framed, panelled shutter (two panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm thick veneered particle board with commercial veneering on both faces; size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated and fixed complete all as specified and as directed.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel, and fixed all as specified and as directed.
S&F 200mm long mild steel barrel tower bolts, stove enamelled black with bright bolt all as specified and as directed.
S&F 150 mm size mild steel pressed handle, oval type, stove enamelled black complete all as specified and as directed.
S&F 300 mm long mild steel sliding door bolt, stove enamelled black with bright bolt not less than 16 mm dia with & including a minimum of 6 bolts & nuts four on bolt plate and two on staple plate complete all as specified and as directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed.
S&F mild steel flat iron in wind ties for roof including securing bolts, nosing, posts/struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets including all necessary drilling holes, notching for wire etc conforming to Fe 290. Gde-165 complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or rivetted or forged into spikes, framed guard bars and similar work conforming to Fe 290. Gde-165 complete all as specified and as directed.
S&F mild steel screw bolts, 11mm to 15mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10 cm long all as specified and as directed.
S&F prepainted galvalume aluminum zinc coating GI based corrugated steel sheets 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F prepainted galvalume aluminum zinc coating GI based plain steel sheets 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F 1.25 mm thick mild steel plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F rolled mild steel joist, channel, angle or tee sections as in main and cross beams, hip and jack rafters; purlins etc fixed with angle cleats or other connecting plates conforming to Fe 290 (Gde-E- 165) complete all as specified and as directed.
S&F rolled mild steel plates (plain or chequred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 290. Gde-165 complete all as specified and as directed.
S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe 290 (Gde- 165) complete all as specified and as directed.
S&F mild steel framed work confirming to Fe 290. Gde-165 as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F mild steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and as directed.
S&F mild steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and as directed.
S&F factory made mild steel ventilator with top hung shutter including hinges, steel peg stays etc complete all as specified & directed.
S&F 9mm thick primium quality laminated PVC tiles 600mm x 600 mm in false ceilling, fixed with screws, including GI frame work for false ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to center/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm center to center GI cleat and steel expansion fasteners with and including ceilling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to center frame work including hanger 6 mm dia GI wire upto 1200 mm length adjustable level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long including dismantling existing false ceiling boards,hangers & framework complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, parapet, chajja etc comprising with the following treatment/specification from bottom to top including taking down/demolition existing decayed water proofing treatment with plaster/PCC padding of any thickness on roof:- (i) Taking out old bituminous felt roof treatment including plaster/PCC padding and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 500 mtr distance from starting point. (ii) 25mm thick(average) PCC type B-0,(1:2:4) using 12.5mm graded stone aggregate finished even & smooth without using extra cement mixed with WPC @ 3% by weight of cement. (iii) Cleaning of roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compount will be measured & paid seperatly.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaing out and filling solidly with a hot mixture of bitumen and clean dry sand in ratio 1:1 (by weight) all as specified and as directed.
Supply only integral water proofing compound, ISI mark all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8, type D2 (using 40 mm graded stone aggregates) as in sub-base complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregates) as in floor, etc finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 3mm thick 38mm wide/deep, glass strips as in dividing strips for floor, fixed in position to confirm to design complete all as specified and as directed
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregates) as in plinth protection, finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for machine cut kota stone flooring, 20-25 mm thick (size of kota stone slab 22"x22") laid over and including 20 mm thick bedding layer of cement mortar 1:6 jointed with grey cement slurry mixed with pigments to match the shade of slab including cutting, rubbing and mirror polishing including removing dust complete all as specified and as directed.
All as per serial item No. 48 here-in-before but 18 to 20 mm thick kota stone on vertical surfaces such as in skiting /dado of size as required at site over and including10 mm thick backing coat of cement mortar (1:4) complete all as specified and as directed.
M&L for 20-25mm thick Cudappah stone slabs as in shelves laid, bedded and jointed in cement mortar 1:4 complete all as specified and as directed.
Rounding to edges of stone slabs such as cooking platform, edges of steps, shelves and like, finished smooth all as specified and as directed
M&L for 60 mm thick precast cement concrete interlocking tiles (glossy finish/ rubber matt finish) hydraulically pressed cemented tiles of grey colour with pigments, (glossy finish/ rubber mat finish) factory made, M-35 grade as in floor laid over & including 25 mm thick sand cushioning and including filling of interstices with fine sand complete all as specified and as directed. Note Size, shape & pattern of tiles shall be as decided.
M&L for precast cement concrete coloured chequered tiles with glossy finish of size 25cm x 25cm 25mm thick, machine pressed with grey cement and pigments, laid over & including 20mm thick screed bed in cement mortar 1:6, set, jointed and pointed in neat cement slurry complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces (external plaster), finished surfaces even and fair all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces (Internal plaster), finished surfaces even and smooth without using extra cement all as specified and as directed.
M&L for rendering 5mm thick in cement mortar 1:3 on fair faces of ceiling concrete surfaces, finished surfaces even and smooth without using extra cement all as specified and as directed.
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc in walls ceiling's stanchions beams etc including all laps cutting and waste all as specified and as directed.
M&L for preparing new plastered surface of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of walls, cornices etc and applying one coat of white wash completed all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying one coat of white wash as specified and as directed.
M&L for preparation of new plastered surfaces of walls applying two coats of cement base paint over a coat of primer all as specified and as directed
M&L for preparation of old plastered surfaces of walls applying one coat of cement base paint all as specified and as directed
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane all as specified and as directed
M&L for preparing new surfaces of wood and wood based materials of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding light fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multi-stranded copper conductor cable of 1100 Volts grade, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) of suitable size and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multi-stranded), PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards for mounting switches, sockets, fan Regulators, accessories etc for one light/fan point controlled by one, one way switch all as specified and as directed. NOTE: 1.Proper colour coding shall be adoptd for wiring (for phase-RED,YELLOW,BLUE & for Earth-Green and Neutral-Black) 2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.)
All as per serial item No 68 but for 5 Amps socket in same board complete all as specified and as directed.
All as per serial Item No 68 but for 5 Amps socket in independent board complete all as specified and as directed.
All as per serial item No 68 but for power point 3 pin, switch socket, 15 Amp with PVC copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board including one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall incl including PVC box 2 mm complete all as specified and as directed
All as per item No 71 but with 4.0 Sqmm copper conductor cable for 15 Amps socket outlet complete all as specified and as directed.
S&F switch piano, flush type, one way, single pole, 5Amp, 20 volts complete all as specified and as directed.
S&F modular switch, single pole, one way, 6/10 Amps, 1 module complete all as specified and as directed.
S&F modular switch, single pole, one way, 15/16 Amps, 1 module complete all as specified and as directed.
S&F switch socket cobination, 2 in 1, 3 pin, 5 and 15 Amp, flush type complete all as specified and as directed.
S&F modular socket, 6 amp 2/3 pin, combined, 2 module complete all as specified and as directed.
S&F modular socket, 6 A/16 amp 2/3 pin, combined, 2 module complete all as specified and as directed.
S&F ceiling rose, surface bakelite, three terminal type complete all as specified and as directed.
S&F in repairs, LED lights fitting 1x 18W, 220V, AC, decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in repairs, LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F in repairs, 35/40 Watt, building mounted LED Security light fitting complete made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2 m long bend to shape required, fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40 x 5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting, complete all as specified and as directed.
S&F in repairs, LED street light fitting, 60 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2 m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40 x 5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting, complete all as specified and as directed.
S&F in repairs, LED street light fitting, 90 Watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete., including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2 m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40 x 5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting, complete all as specified and as directed.
S&F 1200mm sweep, 230V, ceiling fans complete with blades, down rod, electronic regulator and accessories, minimumin air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed.
S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed.
S&F in repairs, sheet metal enclosure, SPN with 2 pin and earth plug and socket complete with and including single pole, 20 Amps MCB, 240V all as specified and as directed.
S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F in repairs, MCB SPN (DP) 240 volts, 40 to 63 Amps ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F in repairs, MCB TPN 415 volts, 100 Amps, ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
Supply, laying, jointing and testing PVC XLPE insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 16 Sqmm, 2 core, laid in trenches/ fixed on wall including electric connections on both ends with suitable lugs,binding wire including taking down existing cable all as required at site all as specified and as directed
Supply, laying, jointing and testing PVC XLPE insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 50 Sqmm, 3.5 core, laid in trenches/ fixed on wall including electric connections on both ends with suitable lugs,binding wire including taking down existing cable all as required at site all as specified and as directed
S&F 1100 V, heavy duty cable, PVC insulated, aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection, suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire, one twin core cable flat of stranded multistrand conductor size 6.0 sqmm including taking down existing cable complete all as specified and directed.
M&L for dry river sand in trenches for cushioning (8 cm below the cable and 15 cm above the cable) of underground cable including spreading, levelling, hand punning complete all as specified and as directed. Note:Punned thickness will be measured and paid.
Supply and laying in replacement of un-reinforced precast concrete cable cover, class LV type-1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and as directed.
S&F in repairs, GI tubing, light grade, 40 mm bore dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and as directed.
M&L for sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC conduit (ISI marked) with all accessories such as Tees, elbows, junction box etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing caping/ Conduit, complete all as specified and as directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm cable and one run of PVC conduit will be measured as one Rm unit .
M&L for sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC conduit (ISI marked) with all accessories such as Tees, elbows, junction box etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing caping/ Conduit, complete all as specified and as directed. Note : Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm cable and one run of PVC conduit will be measured as one Rm unit .
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
D V Engineers and Contractors Pvt Ltd
M/S. M.A. Sharief engineers and contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .