Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹49.5 L+₹4.1 L (9.01%)Rejected-Finance NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.0 L+₹4.6 L (10.1%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.6 L+₹5.2 L (11.5%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.4 L+₹6.0 L (13.1%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹97,600
Closing Date
5 Oct 2023, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
SPECIAL REPAIRS/ REPLACEMENT OF EXISTING CI PIPE LINE AND CERTAIN MINOR WORK AT AF STN SULUR
2023_MES_618693_1
8609/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹97,600
Yes
10 Nov 2023
14 Sept 2023
6 Oct 2023
14 Sept 2023
5 Oct 2023
29 Sept 2023
14 Sept 2023 - 26 Sept 2023
Amount
SCHEDULE A BOQ
Supply & fix TPN, MCB 20 to 32 amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and including suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 3:- (a) 4 runs of 10 sqmm cable along with 2 runs of 10 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 sqmm drawn through in and including suitable size PVC casing capping and all accessories fixed to wall/floors along with 1 run of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 6:- (a) 2 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S&F factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed.
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified.
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing and capping fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly for one switch socket outlet 3 pin 5 Amps on independent board complete all as specified and directed.
Supply & fix modular Socket, 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix modular switch 1 way 6 Amp,1 module complete all as specified and directed.
Supply & fix modular Metal flush box, 3 module complete all as specified and directed.
Supply & fix modular White cover plate with frame, 3 module complete all as specified and directed.
S & F Rotational moulded polythene water storage tank of 500 Ltrs capacity (ISI Marked) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet hoisted and fixed in position all as specified in SSR part -I complete all as specified and directed.
M & L for making connection of PP-R distribution branch with PP-R main of sizes 16 to 40 mm bore by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S & F ball brass valves of size 25mm bore, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
S & F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. all as specified and directed.
Note for item No 19 :- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b ) Wall thickness of pipes shall be all as per IS : 15801
Supply and fixing PP-R Gate Valves (Brass insert) 32 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S & F Galvanised steel water tubing, medium grade of size 20 mm bore with all fittings and laid in trenches complete all as specified and directed.
Supply and fixing PP-R Gate Valves (Brass insert) 25 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
Excavation in trenches not exe 1.5m wide and not exc 1.5 mtr depth for laying cable, pipes etc and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated material to a distance not exc. 50m and depositing where directed at level not exc 1.5 m above complete all as specified and as directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (cost for copper strip up to 7.5m is deemed to be inclusive in quoted rate). Any additional requirement will be paid and measured seperately inder relevent item here-in-below
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
S & F Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed.
Note for Item No 47 :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed.
S&F epoxy base insulators of suitable size 40mm height for fixing copper earth strip on wall/ceiling/floor/poles etc.
Supply and fix Water heater with storage type, vertical, electric single phase 240 V, 2 KW heating element, Capacity 25 ltrs, BEE 5 star rated complete all as specified and directed.
Note for item No 51 :- The Contractor shall give a written guarantee for a period of two years from completion of work.
Supply & fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Casing and capping with all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 54:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC casing and capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply & fix industrial type metal clad plug top & socket single pole and a neutral link earth enclosure with one MCB SP 20 Amp complete all as specified and directed.
S&F Stop valves, 20 mm Bore fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F 20 mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
Taking down unserviceable steel / CI / Ductile iron pipes and connections and removal to kept store for the following sizes complete all as specified and directed.
32 mm bore
50 mm bore
63 mm bore
90 mm bore
100 mm bore
S & F 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, laid in trenches with following sized PP-R pipes complete all as specified and directed.
32 mm outer dia
50 mm outer dia
63 mm outer dia
90 mm outer dia
Note for item No 66 to 70 :- (a) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b ) Wall thickness of pipes shall be all as per IS : 15801
(c) Earth work excavation, return filling and removal of excavated soil shall be measured and paid seperately under relevent items here-in above.
Taking down unserviceable Sluice valve removal to store for the following sizes complete all as specified and directed.
100 mm bore
80 mm bore
S & F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 100 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
S & F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 80 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
Supply and fixing in repairs PP-R Gate Valves (Brass insert) 63 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
Supply and fixing in repairs PP-R Gate Valves (Brass insert) 50 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
Supply and fixing in repairs PP-R Gate Valves (Brass insert) 32 mm outer dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
M&L in repairs Construction of Valve Chamber of size 1000x1000x750 mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded stone aggregate for foundation, 200 mm thick Brickwork with fly ash bricks using modular bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
M & L plain cement concrete Type C-2, 1:3:6 using 40 mm graded granite stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
S & F Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" for 100mm bore with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete all as specified and as directed.
Note for Item No 84:- Earth work excavation, return filling and removal of excavated soil shall be measured and paid seperately under relevent items here-in above.
S & F in repairs DI fittings Bend,(any type ,radius and angle) tapers any type (straight, bend,increasing,decreasing or double socket etc), Tee pieces, connection pieces, collers, caps and plugs complete all as specified and directed
shalom constructions
SREEKRUPA ENTERPRISES
devan enterprises
A.GOVINDARAJ
S.RAMACHANDRAN
T C KARUNANITHI
p.chinnasamy
N SARAVANAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .