| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.4 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.5 Cr+₹8.1 L (5.62%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.5 Cr+₹8.1 L (5.62%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.5 Cr+₹8.5 L (5.85%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr+₹8.5 L (5.85%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.7 Cr+₹20.2 L (14.0%)Rejected-Finance | ₹1.7 Cr+₹20.2 L (14.0%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹2.1 Cr+₹63.3 L (43.7%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹2.1 Cr+₹63.3 L (43.7%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L2 | RAMESH BABU CO L4 | M/S SRI BALAJI ENTERPRISES L5 | UNIVERSAL ENGINEERING L3 | devan enterprises L1 | SUPER COOL L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance along with blower assembly filter and other components including checking electrical connections complete all as specified and as directed. | 2 | Each Job | 1,450 ₹2,900 | 1,100 ₹2,200 Lowest | 1,550 ₹3,100 | 1,500 ₹3,000 | 1,350 ₹2,700 | 3,000 ₹6,000 |
| 2.00 | Material and labour for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed. | 1 | Each | 1,650 ₹1,650 | 1,000 ₹1,000 Lowest | 1,700 ₹1,700 | 3,000 ₹3,000 | 3,000 ₹3,000 | 35,000 ₹35,000 |
| 3.00 | Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed.
Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ. | 5 | Each Job | 2,600 ₹13,000 | 1,900 ₹9,500 Lowest | 2,650 ₹13,250 | 2,600 ₹13,000 | 2,200 ₹11,000 | 10,000 ₹50,000 |
| 4.00 | Supply and fix PCB (circuit plate) of in-door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 3 | Each | 5,300 ₹15,900 | 5,000 ₹15,000 | 6,000 ₹18,000 | 5,000 ₹15,000 | 4,800 ₹14,400 Lowest | 13,000 ₹39,000 |
| 5.00 | Supply and fix PCB (circuit plate) of out door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 2 | Each | 3,650 ₹7,300 | 3,000 ₹6,000 Lowest | 3,500 ₹7,000 | 3,550 ₹7,100 | 3,500 ₹7,000 | 19,000 ₹38,000 |
| 6.00 | Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. | 2 | Each | 44,500 ₹89,000 | 42,500 ₹85,000 | 44,200 ₹88,400 | 47,000 ₹94,000 | 45,000 ₹90,000 | 23,000 ₹46,000 Lowest |
| 7.00 | Removing the window/ split type AC up to 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.
Note :- The rate of following deemed to be included in quoted rate :-
a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower
b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower
c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary
d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete
(e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
(f) Spares will be measured and paid separately.
(g) Refrigerant gas will be measured & paid separately. | 150 | Each Job | 950 ₹1,42,500 | 1,600 ₹2,40,000 | 1,000 ₹1,50,000 | 1,000 ₹1,50,000 | 1,300 ₹1,95,000 | 900 ₹1,35,000 Lowest |
| 8.00 | Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing one complete all as specified and directed. | 110 | RM | 45 ₹4,950 | 50 ₹5,500 | 55 ₹6,050 | 40 ₹4,400 Lowest | 40 ₹4,400 Lowest | 100 ₹11,000 |
| 9.00 | Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location complete all as specified and directed. | 35 | Each | 2,200 ₹77,000 | 2,000 ₹70,000 | 2,300 ₹80,500 | 2,050 ₹71,750 | 1,850 ₹64,750 Lowest | 3,500 ₹1,22,500 |
| 10.00 | Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed. | 15 | Each | 300 ₹4,500 | 350 ₹5,250 | 350 ₹5,250 | 300 ₹4,500 | 280 ₹4,200 Lowest | 350 ₹5,250 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
10 Sept 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF VARIOUS TYPE OF ACs SUMMER APPLIANCES SECURITY AND ELECTRICAL INFRASTRUCTURE SWITCH GEAR EARTHING AND OTHER MISC E M WORKS AT AFTC 2 DC AREA AND AFS JALAHALLI EAST WEST AREA
2025_MES_726042_1
8188/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
Garrison Engineer M AF Jalahalli
₹2.3 L
29 Sept 2025
13 Aug 2025
17 Sept 2025
13 Aug 2025
10 Sept 2025
3 Sept 2025
13 Aug 2025 - 20 Aug 2025
Amount
Material and labour for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance along with blower assembly filter and other components including checking electrical connections complete all as specified and as directed.
Material and labour for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed.
Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ.
Supply and fix PCB (circuit plate) of in-door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed.
Supply and fix PCB (circuit plate) of out door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Removing the window/ split type AC up to 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM. (f) Spares will be measured and paid separately. (g) Refrigerant gas will be measured & paid separately.
Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing one complete all as specified and directed.
Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed.
Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing one and complete all as specified and directed.
Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed.
Supply and fixing Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed.
Supply and fixing as in repair of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix dummy nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TR including taking down existing one complete all as specified and directed.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix as in repair PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed.
Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed.
Supply and fix indoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton including taking down existing one complete all as specified and directed.
Removing old unserviceable split type air conditioner outdoor unit frame and Supply and fix outdoor unit frame of the split type air conditioner 1.5/2 TR capacity, complete with refixing with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed.
Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed.
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed.
Material and labour for shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed. Make : Havells/ Indo asian/ Legrand
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
M&L core cutting of of size 50 mm dia in stone wall with the help of machine and preparing surface to make good matching with existing surface coloured complete all as specified and directed.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d) The work shall be done by a specialized team of Engineer/Technicians of OEM.
Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed.
Supply and fixing PCB board of inverter type split type AC for 1.5 Ton/2 Ton including taking down existing unserviceable one at any location complete all as specified and directed.
Material and labour for shifting of Air Conditioner, Window type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Inspection, checking adjustment and minor repair of unserviceable window type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc., complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing Blower motor (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing unserviceable one complete all as specified and directed.
Supply and fix Filter (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one complete all as specified and directed.
Supply and fix condenser fan blade suitable for 1.5 Ton split/ window AC including taking down existing unserviceable one and complete all as specified and directed.
Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for window type AC of capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fixing Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of window type AC up to and including 1.5/ 2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one complete all as specified and directed.
Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed. Note: Toping up of gas will be measured and paid separately
M&L core cutting of of size 50 mm dia in bricks wall with the help of machine and preparing surface to make good matching with existing surface coloured complete all as specified and directed.
Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified and directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and as directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 308 to 350 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement) complete all as specified and as directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas will be measured and paid separately
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing ice superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 260 to 308 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed.
Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note:Topping up of gas will be measured and paid separately
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
Supply and fixing Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed.
Material and labour for preparing the old painted surface of refrigerator of capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 165 to 260 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
Supply and fixing in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed.
Supply and fixing Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Thermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, complete all as specified and directed.
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed .
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Servicing the Voltage Stabilizer 0.5 KVA/2KVA single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note: Topping up of gas will be measured and paid separately
Servicing the Voltage Stabilizer 4 KVA to 5 KVA single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 150/180 litres capacity, complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 160 to 180 Litres capacity complete all as specified and directed.
Supply and fixing Door gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed.
Material and labour for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed.
Supply and fixing PVC drain out pipe 30mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
Supply and fixing Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed.
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed.
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid separately
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas will be measured and paid separately
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
Supply and fixing Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed.
Supply and fixing Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Material and labour for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas will be measured and paid separately
Supply and fixing Carbon (filter) 12” size incl taking down old unsv complete all as specified and as directed.
Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed.
Supply and fixing Multi capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas.
Material and labour for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
M & L for Over hauling and repair/replacement of unserviceable items of Portable RO unit of capacity 80 LPD by disconnecting all pipe lines , filters catridges, RO Membrane , motor, float valve and water storage tank, all filter catridges(Pre Activated carbon ,Post Activated carbon, inline sedimant , pre particle filter), motor carbon brushes, pressure pump diaphram, float valve,solenoid valve,12/24v SMPS power supply unit , damaged piles lines , bends ,tee , elbow, water flow restrictor including cleaning of water storage tanks and testing (TDS ), fixing of pre filters all respect and replacement of minor spare such as carbon brush ,tee ,elbow,pipe line,teflon tape,screws,nuts etc include in this quoted rate for smooth functioning of RO Plant complete all as specified and as directed. Note : Major spare parts shall be measured and paid seperately as supply only under relevant items of BOQ.
Supply only pre-activated carbon filter with clamps suitable for RO unit all as specified
Supply only RO pressure Pump Diaphram Head unit suitable for RO unit all as specified
Supply only Reverse Osmosis membrane with clamps suitable for RO unit all as specified
Supply only pre particle filter with food grade housing arrangement and with clamps suitable for RO unit all as specified
Supply only float switch suitable for RO unit all as specified
Supply only Inline sediment filter with clamps suitable for RO unit all as specified
Supply only Pressure pump 12/24v suitable for RO unit all as specified
Supply only Post-activated carbon filter with clamps suitable for RO unit all as specified
Supply only TDS,PH,Chlorine mesauring digital device all as specified
Supply only 12/24v SMPS suitable for RO unit all as specified
Supply only solenoid 12/24v suitable for RO unit all as specified
Supply and fixing as in repair pre filter housing element with suitable size of filter to protect RO including PVC pipe of required length and all connected items complete all as specified and directed.
Material and labour for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod and winding etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 134 (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Jalahalli
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. separately.
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient ISI mark with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient. Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. separately.
Material and labour for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 405 litres including vacuuming and charging the refrigerant Refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid separately
Supply and fixing Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and fixing hermetic sealed new compressor (in replacement) 1/6 HP suitable for deep freezer of capacity 405 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 405 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed
Supply and fixing Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and fixing Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply only Regrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and as directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. (Note:- Rewinding, and materials to be replaced are measured separately.)
(a) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(b) Defective unserviceable part like fan bush, bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
(c) The entire job will be carried out in Air Force stn Jalahalli
(d) Necessary T&P such as ladder, helper shall be contractor responsibility.
(e) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(f) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(g) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(h) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed.
Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed.
Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450mm sweep complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450 mm sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing complete all as specified and directed.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 250mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 300 mm sweep complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 250mm sweep complete all as specified and directed.
Supply and fixing Exhaust fan 250 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 250 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty, 1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 300 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to hight 11 mtr complete all as specified and directed. Note : All safety measures is the responsible of the contractor
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
Supply and fixing Exhaust Fan 450 mm sweep, 230/240 volt AC single phase, heavy duty, 1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping ets as per site requirement on walls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc complete for the following :- Make of wire: Polycab/Plaza/Havells Note: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 210 here in before but for One light point/fan point controlled by one way 5 Amp switch.
All as per item No. 210 here in before but for One light point controlled by two way 5 Amp switch.
All as per item No. 210 here in before but for one bell point controlled by one way bel push.
All as per item No. 210 here in before but for One 3 pin socket out let 5 Amp on the same board
All as per item No. 210 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per item No. 210 here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
All as per item No. 210 here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed Make : Anchor/Havells/L&T
S & F electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T
S & F fan regulator 120W, for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T
Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F of MCB single pole 240 volts 6 to 32 Amps 10 KA C curve complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in repairs 35/36 W( WH) LED recessed type 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. Make : Philips/ Bajaj /CG/Havells.
S&F in replacement factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB in repair and replacement of SPN 240 volts 16 to 40 Amps 10 KA C curve complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in replacement factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directedMake : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etc in soft/loose soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material to out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down. Pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply and laying in repair of GI pipe light grade for cable protection of size 80mm bore with fittings, complete all as specified and directed.
Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 75 Sqmm to 120 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 120 Sqmm to 185 Sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lemp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following:-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 25 KA - 02 Nos. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 16 KA - 02 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase S upply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 05 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supplying and laying reinforced precast concrete cable cover, class EHV, type 2 with flat, size 450mm x 180mmx 40mm, all as specified and as directed.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HT UG), 11000 volts grade with stranded aluminium conductor of size 3 core 95 Sqmm (Earthed) including taking out existing unserviceable cable complete all as specified and as directed. Make: Havells/Polycab/RPG Asian Note - Earthwork and bricks to be measured and paid separately under respective items.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core complete all as specified and as directed. Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 8 hours of receipt of intimation through telephone from Engineer-in-charge failing which recovery of Rs. 10000.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “Each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch, irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately
Supply and fixing ON LOAD change over switch 4 pole 630 Amps with sheet metal enclosure in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connecting fasteners, burnt cables, accessories, all as per site requirement/existing make/model, complete all as specified and as directed. Make: L&T, HAVELLS, INDO ASIAN
Attending complaints for non-functional/ unserviceable street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc) by deploying technically qualified and experienced technicians to find out defects and taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tape to insulate the LT joint etc and testing complete all as specified and as directed at AF Station East and West Area Jalahalli.
Note : The following items are deemed to be inclusive of quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day)
A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.
Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS.
Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department.
Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department.
Material required for the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the lights fittings shall deemed to be included in the rate quoted.
Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.
All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
Contractor has to ensure serviceability of all Street/ Security Lights in above mentioned DOMESTIC & TECHNICAL AREA on Daily basis in any weather condition at their own arrangement.
In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
The decision of the Accepting Officer in this regards shall be final and binding.
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 200 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 120 to 150 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 80 to 100 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures including taking down of old one complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent
Supply and fix as in repair NO/NC of capacity suitable for 32-40 A contactor including taking down of old one complete all as specified and as directed . Make:- Legrand /Indo Asian /L&T
Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed and directed. Make:- Legrand /Indo Asian /L& T
M&L for wiring of unserviciable Timer panel box and replacement of existing size of copper wire with copper lugs and other connected items complete all as specified and as directed
Supply and fix contactor of capacity 32- 40 A 3 Pole 415 V with 2NO+2NC including taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 36 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fix digital timer switch 24 hrs including taking down of old one complete all as specified and as directed. Make:- Legrand /Indo Asian /L&T
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 40 to 45 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 60 to 75 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Taking down and errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.
M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to pole including necessary form work slightly rounding or squaring, complete all as specified and as directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 90 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 60 to 72 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. .Make :- Havells/Polycab/ RPG Asian
Material and labour in repair for 3.5 core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed.
Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 25 Sqmm to 35 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
S & F aluminum lugs suitable for aluminum cable of size 10 to 35 Sqmm complete all as specified and directed
S & F copper lugs suitable for copper cable of size 10 to 35 Sqmm complete all as specified and directed
Supply and fix in repair LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.
Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL
Material and labour for applying one coat of cement base paint to RCC pole 7/9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of Aluminium paint. Cement base paint shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.
Material and labour for Painting of steel tubular pole 7/9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fix in repair of LED street light 45/48 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:Halonix/Philips/CG/Bajaj
Supply and fix in repair Time switch Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed. Make : L&T/ Havells/ Indoasian
Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj
Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Halonix/Bajaj/ Philips/CG
Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed. Make: Bajaj / Philips/Halonix/ CG
Material and labour in repair for 4 core10 Sqmm XLPE insulated heavy duty electric cable with aluminium single stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. .Make :- Havells/Polycab/ RPG Asian
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 10 Sqmm to 16 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 No including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fix in repair of LED street light 35/36 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make : Philips/CG/Bajaj/ Halonix
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed.
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells
Supplying, errecting and fixing as in repair GI tubular swaged welded pole of over all height 6.0 m long complete with GI base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed . Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.
Supply and fix in repair smart integrated solar all in one LED solar street light fitting 12 V,13 Watts with IP 66/65 protection, built-in MPPT charge controller,Lithium ion battery,mono crystalline solar panel, PIR motion sensor complete with anodised reflector, toughened heat resistant glass cover, LED 25 watts white colour lamp, connector block with all accessories pre wired including bracket,welding,drilling,bolts,nuts and any alteration required for fixing the panel with existing pole, complete all as specified and as directed. Make:Philips/CG/Havells/Bajaj
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 330 here in before but for one light point/fan/bell point controlled by one way switch.
All as per item No. 330 here in before but for one light point controlled by two way switch.
All as per item No. 330 here in before but for one bell point controlled by one bell push.
All as per item No. 330 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 330 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 330 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
All as per Sl No 330 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular switch bell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and fix White cover plate with frame,2/3 module
Supply and fix White cover plate with frame,4 module
Supply and fix White cover plate with frame,8 module
Supply and fix White cover plate with frame,6 module
Supply and fix White cover plate with frame,12 module
S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed Make : Legrand/ Crabtree/ Anchor
Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F of MCB single pole 240 volts 40 to 63 Amps 10 KA C curve complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in repairs 35/36 W (WH) LED Surface type 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. Make : Philips/ Bajaj /CG/Havells.
S&F in replacement factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB in repair and replacement of SPN 240 volts 40 to 63 Amps 10 KA C curve complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
Supply and fix 4 Pole MCCB, 415 volts, fixed type, 250 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells
S & F aluminum lugs suitable for aluminum cable of size 50 to 95 Sqmm complete all as specified and directed
S & F aluminum lugs suitable for aluminum cable of size 120 to 185 Sqmm complete all as specified and directed
Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 95 Sqmm to 120 Sqmm, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 95 Sqmm to 120 Sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply and fix in repair MCCB of capacity 400 Amps 415 Volts 4 pole with breaking capacity 36 KA in LT panel boards / feeder pillar boxes including disconnecting existing from electric connection including necessary connecting fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model, complete all as specified and directed. Make: L&T, HAVELLS, INDO ASIAN
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Changeover front operated of capacity 250 Amps ,4 Pole ,415 Volts 01 No (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 02 Nos. (e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 40 Amp, 10 KA - 01 No. (f) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 06 Nos. (c) MCB SPN of 240 V of capacity 40 Amps 10 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermi proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants &Halogen free. The manufacturer of boards/panels shall be submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulatiocirculation & to minimize temp rise. Panel should be fitted with one No of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 400 Amps ,36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 315 Amps , 36 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 250 Amps ,25 KA - 01 No. (d) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 160 Amps ,25 KA - 02 Nos. (e ) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder -01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schenider/L&T/C&S. (vi) MCCB should be ICu = 100 % ICs . (v) Make of LT Panel /FPB shall be as per mentioned in list of makes (PS).
Note :- An amount of Rs 2,43,424.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
LAKSHMI ELECTRICAL ENTERPRISES (BID ID -3418874)
UNIVERSAL ENGINEERING (BID ID -3421205)
RAMESH BABU CO (BID ID -3420454)
M/S SRI BALAJI ENTERPRISES (BID ID -3420520)
SUPER COOL (BID ID -3421722)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .