Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
1 Aug 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
M AND P
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Contractor has to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with a supervisor competency certificate as per Regulation 29 of the Central Electricity Authority (Measure relating to Safety and Electric Supply) Regulation 2010 or latest / as per Rules 45 of the Indian Electricity Rules 1956 along with the tender documents, failing which the offer is liable to be rejected.
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/we have read the General Conditions of Contract (GCC) with all Correction Slips up to date, NIT, Tender Document, Corrigendum (if issued) carefully and submitted all the relevant documents as per the requirement of Tender Document. I/we understand that if I/we failed to submit any required document, my bid will be liable for summarily rejection.
Electrification arrangement for DPRS testing Shed, Extension of DPRS Shed, Extension of Vande Bharat Shed and extension of Finishing Shop in Workshop area RCF Kapurthala.
RCF-EL-MTC-82A-ET-26-27
RCF-EL-MTC-82A-ET-26-27
Open
Works - General
12 Months
Kapurthala, Punjab
₹0
₹6.0 L
1 Aug 2026
10 Jul 2026
18 Jul 2026
104 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,01,28,304.08 | ||
| — | 536.00 | — | — | ||
| Supply ,installation ,erection, testing and commissioning of Indoor Industrial LED Light 150 watt luminaries fittings Make: Crompton, Havelles, Philips providing of all necessary & required accessories for proper fixing, mounting & installation i.e., Brackets, Clamps, Hook, SS and /or Anti-rusted Brass (Electroplated) Fasteners, Nuts, Bolts, Washers and GI pipe suitable for hanging or fixing on pillars etc. as required quantity are in the scope of tenderer. | — | — | — | 28,26,542.4 | |
| — | 172.00 | — | — | ||
| Supply, Installation & Commissioning of Small Tool DB's as per explanatory notes. | — | — | — | 11,97,980 | |
| — | 442.00 | — | — | ||
| Supply, installation, testing &commissioning of 4-way Cable Junction Boxes CRCA powder coated with 20 amp. connector 3 phase with neutral size not less than 180x180x80 mm with cover on truss at required height complete with fixing arrangement and suitable for 4 Core x 16 SQ MM U/A cable. | — | — | — | 1,76,176.78 | |
| — | 105.00 | — | — | ||
| Supply, Installation and Commissioning of Tap out boxes 300mm wide x 500mm long x200mm deep with cover. Powder coated CRCA Sheet thickness shall be 2.5 mm, with aluminium bus bar 50 mm widex5mm thick with DMC insulator base for 3 phases and neutral separately. | — | — | — | 4,20,000 | |
| — | 10.00 | — | — | ||
| Supply, Installation and Commissioning of Tap out boxes (with R,Y,B and N bus bar) 300mm widex350mm longx200mm as per explanatory notes | — | — | — | 26,000 | |
| — | 18.00 | — | — | ||
| Supply, installation, Testing and commissioning of Lighting FDB as per explanatory notes. | — | — | — | 1,79,100 | |
| — | 2320.00 | — | — | ||
| Supply, Installation & Commissioning Of 300 MM Wide Cable Tray as per explanatory notes. | — | — | — | 11,56,960.8 | |
| — | 16.00 | — | — | ||
| Supply, Testing & Commissioning of Earthing Station as per explanatory notes. | — | — | — | 1,30,720 | |
| — | 4360.00 | — | — | ||
| Supply & providing of MS conduit pipe of 16 SWG 25mm dia ISI marked | — | — | — | 3,20,808.8 | |
| — | 8.00 | — | — | ||
| Supply, Installation and commissioning Timelite DB 70A 3 Pole contactor /230V Dual Digital Timer Switch (Digital Timer 2 CO TDA 43111) of Indoasian make or equivalent make. As per Explanatory Note. | — | — | — | 1,35,610 | |
| — | 1200.00 | — | — | ||
| Supply, Installation, testing and commissioning of Pit Light 10-watt Led Light as per explanatory notes | — | — | — | 6,19,500 | |
| — | 220.00 | — | — | ||
| Supply and Laying of RCC Hume /HDPE pipe suitable for 400 sq mm XLPE cable conforming to relevant IS inside dia. | — | — | — | 89,999.8 | |
| — | 7.00 | — | — | ||
| Supply, installation, termination, testing & commissioning of floor mounted outdoor type with double door both side open front & back Sub Distribution Board as per explanatory notes. | — | — | — | 8,75,000 | |
| — | 7.00 | — | — | ||
| Supply, installation, termination, testing & commissioning of floor outdoor type with double door both side open front & back Main Distribution Board as per explanatory notes. | — | — | — | 23,99,999.98 | |
| — | 2100.00 | — | — | ||
| Supply of 4x 400 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armoured cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 35,03,892 | |
| — | 150.00 | — | — | ||
| Supply of 4x 150 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armoured cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 93,633 | |
| — | 4760.00 | — | — | ||
| Supply of 4x 95 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armoured cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 25,10,709.6 | |
| — | 1350.00 | — | — | ||
| Supply of 4x 70 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armoured cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 4,36,482 | |
| — | 900.00 | — | — | ||
| Supply of 4x 50 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armored cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 2,61,000 | |
| — | 2200.00 | — | — | ||
| Supply of 4x 35 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armored cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 5,56,996 | |
| — | 5794.00 | — | — | ||
| Supply of 4x 25 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armored cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 6,82,243.5 | |
| — | 1900.00 | — | — | ||
| Supply of 4x 16 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armored cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 2,96,191 | |
| — | 6000.00 | — | — | ||
| Supply of 2x10 Sq.mm XLPE insulated PVC outer Sheathed aluminum conductor armored cable suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1)-1988. with amendment number 1&2 &3 reaffirmed 2005. | — | — | — | 6,49,380 | |
| — | 24664.00 | — | — | ||
| laying and fixing of XLPE insulated PVC outer Sheathed aluminum conductor armored cable up to 400 sq.mm. | — | — | — | 2,96,461.28 | |
| — | 2200.00 | — | — | ||
| Excavation of cable trench under road/Rly line crossing/Pavement area for laying of cable 1.5 meter deep and 400 mm wide including repair the same. As per Explanatory Note | — | — | — | 2,88,002 | |
| — | 22.00 | — | — | ||
| Supplying & making cable End termination of4x400 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 19,398.06 | |
| — | 12.00 | — | — | ||
| Supplying & making cable End termination of4x150 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 4,452 | |
| — | 105.00 | — | — | ||
| Supplying & making cable End termination of4x95 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 31,500 | |
| — | 60.00 | — | — | ||
| Supplying & making cable End termination of4x70 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 11,940 | |
| — | 40.00 | — | — | ||
| Supplying & making cable End termination of4x50 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 4,000 | |
| — | 356.00 | — | — | ||
| Supplying & making cable End termination of4x35 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 28,480 | |
| — | 396.00 | — | — | ||
| Supplying & making cable End termination of4x25 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland, nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 31,680 | |
| — | 112.00 | — | — | ||
| Supplying & making cable End termination of4x16 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 7,191.52 | |
| — | 446.00 | — | — | ||
| Supplying & making cable End termination of 2x10 Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland, nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory | — | — | — | 28,227.34 | |
| — | 22954.00 | — | — | ||
| Supply & Laying of 8 SWG GI earth wire with proper thimbling . | — | — | — | 3,44,080.46 | |
| — | 1500.00 | — | — | ||
| Supply wiring, testing and commissioning of light point with 2x1.5 sq.mm multi stranded copper conductor, conforming to IS-694-1990 with 1 sq.mm green multi stranded copper wire as earth) | — | — | — | 1,42,500 | |
| — | 2130.00 | — | — | ||
| Supply wiring, testing and commissioning of light point with 2x2.5 sq.mm multi stranded copper conductor, conforming to IS-694-1990 with 1 sq.mm green multi stranded copper wire as earth). | — | — | — | 1,19,024.4 | |
| — | 2166.00 | — | — | ||
| Supply and fixing of Flexible Conduit pipe 10 sq.mm. | — | — | — | 75,810 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 25 Presence/Absence Indicator as per explanatory notes | — | — | — | 12,65,000 | |
| — | — | — | KV AC | ||
| — | — | — | OHE | ||
| — | — | — | Power | ||
| — | 214.00 | — | — | ||
| Supply of Industrial type Air Circulators (Man cooler) as per explanatory notes. | — | — | — | 34,06,880 | |
| — | 214.00 | — | — | ||
| Supply, installation and commission of Direct Online Starter in sheet steel enclosure range 1.6 to 2.5 Amps. Contactor coil-415V-440 VAC with overload relay suitable for 1.0 HP 3 phase motor. Make-Siemens, BCH or L&T. | — | — | — | 2,55,516 | |
| — | 214.00 | — | — | ||
| Mounting/ Fixing and commissioning of man cooler on wall/pillar by welding of base plate required at site and wiring of man cooler from starter to fan. | — | — | — | 21,293 | |
| — | 3880.00 | — | — | ||
| Supply Wiring, testing and commissioning of Air circulator with 3x2.5 size of FRLS PVC insulated multi stranded copper conductor wire, conforming to IS-694-1990, in existing MS Conduit 25 mm dia. | — | — | — | 4,57,141.6 | |
| — | 700.00 | — | — | ||
| Supply Wiring, testing and commissioning of Air circulator with 3x1.5 size of FRLS PVC insulated multi stranded copper conductor wire, conforming to IS-694-1990, in existing MS Conduit 25 mm dia. | — | — | — | 66,500 | |
| — | 2680.00 | — | — | ||
| Supply Wiring, testing and commissioning of Air circulator with 1x1.5size of FRLS PVC insulated multi stranded copper conductor wire, conforming to IS-694-1990, in existing MS Conduit 25 mm dia. | — | — | — | 1,20,600 | |
| — | 32.00 | — | — | ||
| Supply, Installation & Commissioning of DB For Air Circulator as per explanatory notes. | — | — | — | 2,64,974.72 | |
| — | 200.00 | — | — | ||
| Supply and fixing of Flexible Conduit pipe 20 sq.mm. | — | — | — | 8,000 | |
| — | 18.00 | — | — | ||
| Supply, installation & commissioning of pillar/wall mounted three phase Jack supply DB made of CRCA sheet 1.6 mm thick, powder coated thickness not less than 40 micron with 02 nos industrial sockets (CEE Type ) 63 amp and 02 nos TPN MCCB 63 amp and 02 nos 125 Amp cable connector as per specification and drawing approved by RCF with fixing arrangement base plate or U channel angle frame properly with suitable nut bolts fasteners/ welding on metal column/RCC wall pillar as required | — | — | — | 2,50,740 | |
| — | 164.00 | — | — | ||
| Supply, installation & commissioning of Pre cooling socket 5 pins 415 V AC 125Amp panel mounted industrial pre cooling socket out let watertight proof with 125amp 3 pole MCCB 35kA in wall/pillar mounted CRCA sheet 2mmthick sheet, box size 350mm x 150mm x550mm (LxBxH)) for ac coach testing arrangement of mentioned make only .As per explanatory Note. | — | — | — | 22,06,146.04 | |
| — | 64.00 | — | — | ||
| Supply, installation & commissioning of pillar/wall mounted three phase welding set DB as per explanatory notes | — | — | — | 8,27,840 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderofDPRSshed82A.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .