Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.5 LAccepted-AOC | L-1 | Accepted-AOC being lowest 1 | |
| 2 | L-2₹7.1 L+₹8,212 (1.17%)Rejected-AOC | L-2 | Rejected-AOC being not lowest 1 | |
| 3 | L-3₹7.1 L+₹11,380 (1.62%)Rejected-AOC | L-3 | Rejected-AOC being not lowest 1 |
Tender Value
₹6.5 L
EMD Value
₹12,920
Closing Date
25 Mar 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er. Rajesh Vashisht
Additional Superintending Engineer, Nangal Dam Division, BBMB, Nangal Township
Construction of one No. room each near Ganguwal spillway and Lohand escape along NHC
2021_BBMB_78110_1
71/2021/NDD
Open Tender
Civil Works
Item Rate
180 days
Ganguwal and Lohand
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹12,920
16 Mar 2023
2 Dec 2021
25 Mar 2022
2 Dec 2021
25 Mar 2022
2 Dec 2021
120 days
Amount
Cvil work
Excavation in Soil (any type) using Hydraulic Excavator CK 90 excavations with hydraulic excavator of 9 cum bucket capacity including cutting rimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead upto 30 mtr. [As per CSR item No. 6.19]
Cement concrete 1:8:16 with stone ballast 40 mm gauge using concrete mixer volumetric type. [As CSR per item No. 10.6 (b) ii]
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. [As per CSR-2020 item No. 11.3-i]
First class burnt brick work laid in cement sand mortar1:6 in first storey up to 4m above plinth level.[ As per CSR-2020 item No. 11.4 (i)]
Damp proof course 4cm thick of cement condcrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded. [As per CSR item No. 10.26]
115 mm thick brick wall laid in cement sand morter 1:4 without reinforcement in superstructure. [ As per CSR-2020 item No. 11.36]
Centerning and shuttering for sides and soffits of beam, berms launching girders bressumers, lintel (CSR item 9.6)
Centering and shuttering for flat surface such as suspended floor, roofs, including chajjas , shelter etc (CSR items no. 9.8)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrated but excluding steel reinforcement centering and shuttering in superstructure. [ As per CSR-2020 item No. 10.20]
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position. [ As per CSR-2020 item No. 18.18 ]
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf/cm2) conforming to IS : 4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf/sqcm) pipe 110 mm dia.[ As per CSR-2020 item No. 13.74 a (i)]
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend [As per CSR-2020 item No. 13.75-a]
20mm thick cement plaster 1:6 in two coat works.[ As per CSR-2020 item No. 15.28]
12.5 mm thick cement plaster 1:6.[ As per CSR-2020 item No. 15.11]
Plastering on underside of ceiling 10 mm thick cement plaster 1:3. [ As per CSR-2020 item No. 15.43]
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling. [As per CSR-2020 item No. 14.3]
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (using mechanical mixer for mixing of material. [As per CSR-2020 items No :- 14.6]
Floating coat of 1.5mm thick neat cement laid in one operation to the topping. [CSR 2020 Item no.14.4]
Supplying and fixing of Pressed steel sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished with 2 coats of ready mixed painted lead non setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. (a) Door and window frame of size 118mmx60mm with 40mm wide single rebate weighing 3.43kg /mtr.[ As per CSR-2020 item No. 18.24 (a) ]
Supplying and fixing of Pressed steel sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished with 2 coats of ready mixed painted lead non setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. (b) Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter. [As per CSR-2020 item No. 18.24 (d) ]
Providing and fixing helical door spring 150mm (superior quality) including necessary screws, complete iron helical spring. [As per CSR-2020 item No. 17.41 (b)]
35 mm thick Kail wood doors shutter and window shutter panelled, glazed or glazed and panelled including hinges screws chokes cleats and cords etc. complete fixed in position (Single Leaf)-b 35 mm thick. [As per CSR-2020 item No.17.17 (i) b]
Wire gauze door shutter with Kail wood without springs housed in chowkhats b) 30 mm thick (single leaf) [ As per CSR-2020 item No.17.17 (ii) b]
Finishing walls with cement-based water-soluble exterior paint such as snowcem, robbiacem etc. two coats to give an even shade. [ As per CSR-2020 item No. 16.14]
Applying pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc. [As per CSR-2020 item No. 16.16]
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. [As per CSR-2020 item No. 16.17]
Electrical Work
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq.mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four-way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): -(i) Wiring fan point (Without fan box) [As per CSR item No. 34.01-a-i]
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq.mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four-way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): -(ii) Wiring light point [As per CSR item No. 34.01-ii]
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq.mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four-way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): -(iii) Wiring 6Amp. wall socket point [As per CSR item No. 34.01-iv]
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq.mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four-way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface): -(iv) Wiring 16/20Amp. power plug control point. [As per CSR item No. 34.01-vi]
THE DASGRAIN CO OP L AND C SOCIETY
THE GAG CO OP L AND C SOCIETY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .