Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC 320N SRINIVAS BUILDING CHINNAMMAL STREET SAIBABA COLONY COIMBATORE TAMIL NADU 641038 | COIMBATORE | TAMIL NADU | 641038 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.5 L+₹25,488 (2.74%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST PRICE | |
| 3 | L3₹9.6 L+₹31,860 (3.43%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST PRICE | |
| 4 | Rejected-Technical 2 4 J S TOWER G 4 BLOCK A AVVAIYAR STREET MEENAMBAKAM CHENNAI 600 027 | KANCHIPURAM | TAMIL NADU | 600027 | - | Rejected-Technical NOT SATIFYING TECHNICAL SPECIFICATION | |
| 5 | Rejected-Technical VI 183 BADKULLA STATION PARA BADKULLA STATION PARA NADIA WEST BENGAL 741121 UDYAM WB 15 0042615 19AJHPB7693L1ZL B R | NADIA | WEST BENGAL | 741121 | - | Rejected-Technical NOT SATIFYING TECHNICAL SPECIFICATION |
| Sl No | Description | Qty | Unit | SINETEC TECHNOLOGIES H3 | MIG TECHNICAL SERVICES H2 | M MAHARANI & K CHANDRA H1 |
|---|---|---|---|---|---|---|
| 1.00Specifications of Digital Storage Oscilloscope | ||||||
| 1.03 | SN Feature Specification
1 Analog channels 2
2 Analog channel bandwidth 70 MHz
3 Sample rate 1 GS/s All channels
4 Record length 20K points
Vertical system Analog channels
5 Input sensitivity range 1 mV/div to 10 V/div max. in 1-2-5 sequence with probe attenuation set to 1X
6 DC gain accuracy ±3.0 % step gain, derated at 0.1 %/°C above 30°C
7 Maximum Input Voltage 300 VRMS, Installation Category II; derate above 4 MHz at 20 dB per decade to 200 MHz
8 Offset range
1 mV/div to 50 mV/div: ± 1 V
100 mV/div to 500 mV/div: ± 10 V
1 V/div to 5 V/div : ± 100 V
9 Bandwidth limit 20 MHz
10 Input coupling DC, AC
11 Input impedance 1 MΩ ±2 % in parallel with 14 pF ±2 pF
12 Vertical zoom Vertically expand or compress a live or stopped waveform
13 Vertical Resolution 8 bits
Acquisition modes
Sample Acquire sampled values
Peak Detect Captures glitches as narrow as 4 nsec at all sweep speeds.
Average From 2 to 256 waveforms included in average.
Hi-Resolution Averages multiple sample of one acquisition interval into one waveform
point.
Roll Scrolls waveforms right to left across the screen at sweep speeds slower
than or equal to 40 ms/div
Horizontal system analog channels
14 Time base range 2 ns/div to 100 sec/div in a 1-2-4 sequence
15 Horizontal zoom Horizontally expand or compress a live or stopped waveform
16 Deskew range ± 100 nsec
17 Time base accuracy ±25 x 10-6 over any >1 ms interval
Trigger system
18 Trigger modes Auto, normal, and single sequence
19 Trigger coupling DC, Noise Reject, High Frequency Reject, Low Frequency Reject
20 Trigger source CH1, CH2, AUX IN, AC Line
21 External trigger input Should be available
Trigger Types
22 Edge Positive or negative slope on any channel. Coupling includes DC, HF reject, LF reject, and noise reject.
23 Pulse Width Trigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time.
24 Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
25 Trigger signal frequency readout Should provide a frequency readout of the trigger source up to instrument bandwidth.
Waveform measurements
Cursors Time, Amplitude, Screen
Automated measurements Should provide 32 measurements, of which up to six can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time,
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR, and Delay RR.
Should have an option to disable auto set and automated measurements features with password protection
Gating Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors or full record length.
Waveform math
Arithmetic Add, Subtract, and Multiply waveforms
FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.
Display
26 Display type Equal to or more than 7 Inch TFT color display with 15 horizontal and 10 vertical divisions
27 Display resolution 800 horizontal by 480 vertical displayed pixels (WVGA)
28 Waveform styles Vectors, Variable persistence, and Infinite persistence.
29 Format YT and XY
Input/Output ports
30 USB Host Port Should support USB 2.0 host ports for mass storage devices
31 USB 2.0 device port USB connector allows for communication/control of oscilloscope through USBTMC or GPIB with a relevant entity
32 Security Lock Kensington Style Lock
Probe compensation signal
Amplitude 5 V
Frequency 1 kHz
Power Source
Line power 100 - 240 VAC RMS ± 10%
Power source frequency 45 Hz to 65 Hz (100 to 240 V)
360 Hz to 440 Hz (100 to 132 V)
Power consumption Less than 40 W (max)
Dimensions
Instrument only
Height less than 180 mm
Width less than 350 mm
Depth less than 120 mm
Cooling Clearance requirements Appropriate clearance should be provided on left side, right side and rear side of the instrument
Operating Temperature 0 °C to +50 °C
Non-operating Temperature -30 °C to +70 °C
Humidity
Operating 5% to 90% relative humidity at temperatures up to +30 °C,
5% to 60% relative humidity at temperatures greater than +30 °C and up to
+50 °C, non-condensing
Non-operating 5% to 90% relative humidity at temperatures up to +30 °C,
5% to 60% relative humidity at temperatures greater than +30°C and up to
+60 °C, non-condensing | 9 | Nos | 7,87,500 ₹9,29,250 Lowest | 8,09,100 ₹9,54,738 | 8,14,500 ₹9,61,110 |
Tender Value
Refer Docs
Closing Date
27 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PRINCIPAL
GOVERNMENT COLLEGE OF ENGINEERING BARGUR-635104
PURCHASE OF ANALOG CHANNEL DIGITAL STORAGE OSCILLOSCOPE
2025_DoTE_530052_1
0731/A2/2025
Open Tender
Machinery and Machining Tools
Supply
10 days
GOVERNMENT COLLEGE OF ENGINEERING BARGUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
16 Sept 2025
5 Mar 2025
29 Mar 2025
5 Mar 2025
27 Mar 2025
5 Mar 2025
Specifications of Digital Storage Oscilloscope
SN Feature Specification 1 Analog channels 2 2 Analog channel bandwidth 70 MHz 3 Sample rate 1 GS/s All channels 4 Record length 20K points Vertical system Analog channels 5 Input sensitivity range 1 mV/div to 10 V/div max. in 1-2-5 sequence with probe attenuation set to 1X 6 DC gain accuracy ±3.0 % step gain, derated at 0.1 %/°C above 30°C 7 Maximum Input Voltage 300 VRMS, Installation Category II; derate above 4 MHz at 20 dB per decade to 200 MHz 8 Offset range 1 mV/div to 50 mV/div: ± 1 V 100 mV/div to 500 mV/div: ± 10 V 1 V/div to 5 V/div : ± 100 V 9 Bandwidth limit 20 MHz 10 Input coupling DC, AC 11 Input impedance 1 MΩ ±2 % in parallel with 14 pF ±2 pF 12 Vertical zoom Vertically expand or compress a live or stopped waveform 13 Vertical Resolution 8 bits Acquisition modes Sample Acquire sampled values Peak Detect Captures glitches as narrow as 4 nsec at all sweep speeds. Average From 2 to 256 waveforms included in average. Hi-Resolution Averages multiple sample of one acquisition interval into one waveform point. Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div Horizontal system analog channels 14 Time base range 2 ns/div to 100 sec/div in a 1-2-4 sequence 15 Horizontal zoom Horizontally expand or compress a live or stopped waveform 16 Deskew range ± 100 nsec 17 Time base accuracy ±25 x 10-6 over any >1 ms interval Trigger system 18 Trigger modes Auto, normal, and single sequence 19 Trigger coupling DC, Noise Reject, High Frequency Reject, Low Frequency Reject 20 Trigger source CH1, CH2, AUX IN, AC Line 21 External trigger input Should be available Trigger Types 22 Edge Positive or negative slope on any channel. Coupling includes DC, HF reject, LF reject, and noise reject. 23 Pulse Width Trigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time. 24 Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again 25 Trigger signal frequency readout Should provide a frequency readout of the trigger source up to instrument bandwidth. Waveform measurements Cursors Time, Amplitude, Screen Automated measurements Should provide 32 measurements, of which up to six can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR, and Delay RR. Should have an option to disable auto set and automated measurements features with password protection Gating Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors or full record length. Waveform math Arithmetic Add, Subtract, and Multiply waveforms FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris. Display 26 Display type Equal to or more than 7 Inch TFT color display with 15 horizontal and 10 vertical divisions 27 Display resolution 800 horizontal by 480 vertical displayed pixels (WVGA) 28 Waveform styles Vectors, Variable persistence, and Infinite persistence. 29 Format YT and XY Input/Output ports 30 USB Host Port Should support USB 2.0 host ports for mass storage devices 31 USB 2.0 device port USB connector allows for communication/control of oscilloscope through USBTMC or GPIB with a relevant entity 32 Security Lock Kensington Style Lock Probe compensation signal Amplitude 5 V Frequency 1 kHz Power Source Line power 100 - 240 VAC RMS ± 10% Power source frequency 45 Hz to 65 Hz (100 to 240 V) 360 Hz to 440 Hz (100 to 132 V) Power consumption Less than 40 W (max) Dimensions Instrument only Height less than 180 mm Width less than 350 mm Depth less than 120 mm Cooling Clearance requirements Appropriate clearance should be provided on left side, right side and rear side of the instrument Operating Temperature 0 °C to +50 °C Non-operating Temperature -30 °C to +70 °C Humidity Operating 5% to 90% relative humidity at temperatures up to +30 °C, 5% to 60% relative humidity at temperatures greater than +30 °C and up to +50 °C, non-condensing Non-operating 5% to 90% relative humidity at temperatures up to +30 °C, 5% to 60% relative humidity at temperatures greater than +30°C and up to +60 °C, non-condensing
MIG TECHNICAL SERVICES (BID ID -1274964)
SINETEC TECHNOLOGIES (BID ID -1271087)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .