Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.3 L+₹2.0 L (6.29%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹34.7 L+₹3.3 L (10.6%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹42.8 L+₹11.4 L (36.4%)Rejected-Finance KOTHI NO 766 PHASE III MODEL TOWN BATHINDA PB | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹45.5 L+₹14.1 L (45.1%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
REPAIR TO ROOF, ROOF SHEETS AND PARAPET WALL TO CERTAIN BLDG AND REPAIR/CLEANING OF SEWAGE LINE IN ZONE M UNDER AGE BR-V OF GE (N) BATHINDA MIL STN
2023_MES_604354_2
8938/NIT-19/23-24
Open Tender
Civil Works
Item Rate
330 days
BATHINDA
Class D Category a(i) (ii)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹70,000
Yes
1 Sept 2023
10 Jul 2023
31 Jul 2023
10 Jul 2023
29 Jul 2023
17 Jul 2023
10 Jul 2023 - 15 Jul 2023
Amount
SCHEDULE 'A' B/R Works
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning top surface of concrete roof slab, lime terracing, or surface of tiles, with wire brush including flashing and junction of parapets etc. and surface painting with layer of blown grade bitumen of any penetration applied hot @ 1.70 Kg per Sqm and 15mm thick screed /rendering in cement mortar (1:6), priming the surface @ 0.30 Kg per Sqm and laying 3mm thick APP based polymer membrane of weighing not less than 3.5 Kg per Sqm reinforced with polyster non woven fabric (weight not less than 150 Gm per Sqm) laid on primed surface at by torch application with side overlap 75mm and end overlap 100mm and tucked into the chasesas a treatment for moderate condition complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
All as peritem No 05 above but except brick tiles (old serviceable brick tiles to be reused after proper cleaning & washing)
Material and labour for PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.30 Kg per Sqm and providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.5 kg per Sqm, reinforced with non woven polyester reinforcemenmt matt weighing not less than 160 Gm per Sqm polysester core, having soften point not less than 150ºC longitudinal tensile strength not less than 650 N per 5cm, tearing strength of 180 N, torch application, side overlap 75mm and end overlap 100mm including ponding test all as specified and directed including demolition of existing treatment including plaster and removing the rubbish to a distance exceeding 1 Km but not exceeding 2 Km, complete all as specified and as directed by Engineer-in-charge.
Roughening surfaces of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc and brushing with neat cement slurry @ 3.0 Kg of cement per Sqm all as directed
M & L for 40 mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in flooring/ roof padding including mixing with WPC and finished even and fair complete all as specified. (Note :- WPC shall be measured and paid for separately.)
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and including ball valve and gate valve, including dismantling/ taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge.
Demolition of RCC as in roof slabs (other than ground floors), beams, stair case, landing, chajjas, and similar suspended work (reinforcement cut as required to facilitate demolition) all as specified and directed by Engr-in-Charge.
M & L for RCC 1:2:4 Type B0 (12.5mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like. (Reinforcement will be measured and paid for separately)
M & L for RCC 1:2:4 Type B0 (12.5mm graded stone aggregates) as in fins, fascias, louvers, parapets, and railings exc. 60cm in height, balustrade, and the like. (Reinforcement will be measured and paid for separately)
Use and waste of form work to sides and soffits of floor or roof beams, roof slabs, cantilevers, shelves etc and similar items rough finished surface complete all as specified and directed by Engr-in-Charge
Use and waste of form work to sides and soffits of fins, louvers, parapet, fascia and similar items rough finished surface complete all as specified complete all as specified and directed by Engr-in-Charge
S & F mild steel TMT bars 10 mm dia , and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe 410-W, Gde E-250 complete all as specified .
All as per ser item No.25 here-in-before but 6 to 8mm dia complete all as specified and directed by Engr-in-Charge.
M & L for guniting/ short crating of RCC columns, beams , fins, facias and similar items as per manufacturers instruction average thickness exc 25 mm but not exc 40 mm complete all as specified and directed by Engr-in-Charge.
M & L for guniting/ short crating of RCC columns, beams , fins, facias and similar items as per manufacturers instruction average thickness not exc 25 mm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Cleaning and removing all scale and dirt, etc., from existing serviceable PVC tanks (OHT) of capacity upto 500 litre, disconnecting or lowering, taking out mud from tank after proper drain out the water (manually or mechanically) including from mouths of circulating pipes etc. after cleaning checking all inlet and out let connections and tightening the same as required, lid of tank refix properly, complete all as specified and as directed by Engineer-in- charge.
Cleaning and removing all scale and dirt, etc., from existing serviceable PVC tanks (OHT) of capacity exc. 500 litre but not exc. 1000 litre, disconnecting or lowering, taking out mud from tank after proper drain out the water (manually or mechanically) including from mouths of circulating pipes etc. after cleaning checking all inlet and out let connections and tightening the same as required, lid of tank refix properly, complete all as specified and as directed by Engineer-in- charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying chalk whitening, preparatory to distempering and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Supply and fixing in repair/replacement Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair/replacement of Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) including taking down existing framed work/framed truss complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 including taking down existing framed work/framed truss complete all as specified & directed by Engineer-in- charge.
Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc., choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc., choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 10mtr) including cleaning of manholes (any type rectangular / square / circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 10 mtr but not exceeding 20 mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 250/300mm dia (length of pipe line manhole to manhole exceeding 10 mtr but not exceeding 20 mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Note for item No 39 and 43 (i) Contractor must employ Minimum Four nos labourer's daily . (ii) Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge. (iii) In case of non attaedence of complaints against BOQ item 39 & 40 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day and for complaints against BOQ item 41 to 43 above, a penalty of Rs 100/- per complaint per day will be recovered from the contractor due. (iv) The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc. and all other other materials for execution of the work shall be included in the unit rate.
Removing the manhole cover (CI or RCC) for opening of septic tank or sewage wells (any type rectangular or circular) of any size and any capacity in foul condition and bailing out of mudy water, taking out semi solid sludge/solid contents/night soil from tank by manually or mechanically by sewage suction pump (at contractor's discretion) making it fully functional and cleaning the internal surfaces with water to the entire satisfaction of Engineer-in-Charge including all necessary tools and plants required for removal of all wastes, solid or liquid sludge from the site through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork and refixing the manhole cover to its original position complete all as specified and as directed by Engineer-in-Charge. Note:- (i) All the tools and plants including mechanical pump, closed lorry and other allied arrangements for making septic tank clean and functional will be made available by the contractor without any extra cost to the Govt. (ii) The mode of measurement shall be considered 25% of the actual volume of septic tank/ manholes (contains human excreta and water). Cost for the dewatering/bailing out of mudy water shall be including in the unit rate(i.e. qty of solid sludge contents) nothing extra shall be paid on this account.
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth for foundations of manholes, sewerage pipe lines etc including getting out complete all as specified and as directed by Engineer-in-Charge .
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe upto and including 150 mm bore pipes, complete all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate to drain pipe including packing under & hunching against the sides of pipe 150 mm dia ( internal) after they are laid and tested in trenches, complete all as specified and directed by Engineer-in-Charge.
Material & labour for 150 mm dia ( internal) SGSW pipes grade ‘A’ laid in trenches & jointed, complete all as specified and as directed by Engineer-in-Charge .
Demolition of cement concrete of any description in ground floor or in any position not exceeding 15 cm thickness, complete all as specified and as directed by Engineer-in-Charge .
Material & labour for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings & mass concrete, sub base, plinth protection, complete all as specified and as directed by Engineer-in-charge.
Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching, flooring and coping, complete all as specified and as directed by Engineer-in-charge.
Material & labour for 15 mm thick cement plaster in CM 1: 4 on fair / unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for 10 mm thick cement plaster in CM 1: 4 on fair / unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement, including mixing of WPC in mortar @ 3% of cement content,complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material & labour pre-cast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in pre-cast manhole cover slabs of any thickness, size or shape including all necessary form work, finishing concrete surface fair & even and set in CM 1:4, including demolition of old cover, complete all as specified and directed by Engineer-in-Charge.
Supply and fixed mild steel work in rungs, hooks, handels, manhole covers, hold fast & small articles, complete all as specified and as directed by the Engineer-in-Charge.
Returning/filling in including spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick each, complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material to distance not exceeding 1.5 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge .
Supply only integral water proofing powder ISI make complete all as specified and directed by Engineer-in Charge.
Supply & Fixed in repair CI cover suitable for 75mm dia CI bend/Tee etc. fixed with bolt and gasket, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixed in repair CI cover suitable for 100mm dia CI bend/Tee etc. fixed with bolt and gasket, complete all as specified and directed by Engineer-in-Charge.
Dismantling and disconecting of existing cast iron soil vent pipe fixed to wall laid in trenches including all fitting & accessories, of any size complete all as specified and directed by Engineer-in Charge.
Supply & Fixed 100 mm dia cast iron soil waste and vent pipes (sand cast) in any length with or without laid in floor with cement joints, complete all as specified and directed by Engineer-in Charge.
Supply and fixed 100 mm dia cast iron soil waste and vent pipes (sand cast) in any length fixed to wall with cement joints including supply & fixing Stack clamps of 50mm x 5mm flat iron & 16mm dia round iron stays, including nuts & bolts & securing ends of stays to wall & roof, complete all as specified and directed by Engineer-in Charge.
Supply & Fixed 75 mm dia cast iron soil waste and vent pipes (sand cast) in any length with or without laid in floor with cement joints, complete all as specified and directed by Engineer-in Charge.
Supply and fixed 75 mm dia cast iron soil waste and vent pipes (sand cast) in any length fixed to wall with cement joints including supply & fixing Stack clamps of 50mm x 5mm flat iron & 16mm dia round iron stays, including nuts & bolts & securing ends of stays to wall & roof, complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair 100 mm bore cast iron bends/Tees of any radius diminshing pieces or tappers (larger bore measured), complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair 100 mm bore cast iron bends/Tees of any radius diminshing pieces or tappers (larger bore measured) with oval access door, complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair CI cowl 100mm bore fixed with cement joint in cement mortor 1:2, complete all as specified and directed by Engineer-in Charge.
Supply & Fixed CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches of 100 mm with oval access door bore, complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair 75 mm bore cast iron bends/Tees of any radius diminshing pieces or tappers (larger bore measured), complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair 75 mm bore cast iron bends/Tees of any radius diminshing pieces or tappers (larger bore measured) with oval access door, complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair CI cowl 75mm bore fixed with cement joint in cement mortor 1:2, complete all as specified and directed by Engineer-in Charge.
Supply & Fixed CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches of 75 mm with oval access door bore, complete all as specified and directed by Engineer-in Charge.
Supply and fixed in repair cast iron floor trap, 75 mm outlet dia, with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by Engineer-in Charge
Supply & Fixed in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) size of cover 0.70 x 0.70 conferming to IS 12592, fixed in cement cocrete 1:2:4, complete all as specified and directed by Engineer-inCharge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
Material & Labour for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exceed 0.11 sqm but not exceed 0.18 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6, complete all as specified and directed by Engineer-inCharge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests and CI 'P' or 'S' trap (excluding flushing cistern, flush pipe above floor), including demolation of tile, PCC, taking out mass concrete filling and re filling PCC (1:7:12) type F2 after fixing of WC and trap with proper joints leakproof including PVC flush pipe upto finished floor level, and making good with 30mm thick cement concrete (1:2:4) type B0 finished rough as a sub base to recieved tile work and including all other connected work as required upto entire satisfaction of Engineer-in-charge, complete all as specified and as directed by Engineer-in- charge. (NOTE : Tile work with screed shall be measured and paid separately under appropriate item of this schedule.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair PVC low level cistern 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pvc pipe of low or high density or PVC 32 mm dia for low level cistern and PVC connections, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including PCC work, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair PVC (SWR) vent cowl suitable for 110mm bore PVC pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair PVC (SWR) vent cowl suitable for 75mm bore PVC pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) floor trap suitable for 100/110mm bore pipe, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in- charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
M/S BHAGWATI CONSTRUCTION COMPANY
V K CONTRACTOR
M/S KARTIK BUILDERS
R K GOYAL & COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .