Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC work allotted | |
| 2 | L2₹6.8 L+₹92,579 (15.7%)Rejected-Finance | L2 | Rejected-Finance Rejected L2 |
Tender Value
₹6.0 L
EMD Value
₹12,080
Closing Date
22 Feb 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Providing Special Repair to EI in PWD BandR Mechanical Workshop, Karnal
2021_HRY_158773_1
158773 Special repair to EI Mech.W/shop Karnal
Open Tender
Electrical Works
Works
60 days
Karnal
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹12,080
19 May 2021
5 Feb 2021
22 Feb 2021
5 Feb 2021
22 Feb 2021
5 Feb 2021
Amount
31.9 Supply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. Size 2.50 sqmm ( 80 / 0.20mm).
Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections . 31.12 (a) (ii) Cat-B Double pole switch 32 amp 240 Volts.
31.12 (a) (xv) Cat-B Triple pole switch with neutral link 63 amp. 415 Volts.
31.12 (a) (xvi) Cat-B Triple pole switch with neutral link 100 amp. 415 Volts.
31.12(a) (xvii) Cat-A Triple pole switch with neutral link 200 amp. 415 Volts.
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 31.12 c (i) 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
31.12 c (ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
31.12 c (iii) 250 amp. 415 V , 35 KA 3-phase.
31.12 c (iv) 300 amp. to 400 amp. 415 V , 35 KA 3-phase.
31.13 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
31.14 (i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
31.15 (ii) Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp.
31.16 (i) Supply and erection of blanking sheet in existing distribution board.
31.17 Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
31.17(a) (ii) SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
31.17(a) (ii) TP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
31.17(a) (ii) TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp.
31.17(a) (iii) TP MCB of 9 KA breaking capacity 40 amp. to 63 amp.
31.17(a) (iii) TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
31.18 (vii) Call bell 220 / 230 volts A.C. bakelite with double coil.
31.18 (ix) (a) Bell push with 4 metres 2-core , 0.50 sqmm (16 / 0.20 mm).PVC flexible wire.
31.18 (xi) Bakelite angle / straight button holder large size.
31.18 (xii) Switch 5 amp. On existing sheet.
31.18 (xiii) Wall socket 5 amp. On existing sheet.
31.18 (xiv) 15 amp. Switch on existing sheet .
31.18 (xv) 3 pin 15 amp. Multi socket on existing sheet.
31.18 (xvii) 3 pin 15 amp. ordinary socket on existing sheet. Ceiling rose flush / surface type .
31.18 (xviii) Bakelite sheet including fixing with brass screws and washers. 5 mm thick .
31.18 (xxii) Erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20watts 610 mm long fluorescent tube with fittings by means of 2 Nos. , 20 mm diameter 1.60 mm thickness conduit pipe with spring loaded brass flanges at both ends including 0.75 sqmm (24/0.20 mm) PVC copper flexible cable for connecting the tube to the adjascent light point including cost of conduit pipe flanges . PVC flxible cable and petty material required for the same ( Upto 1/2 metre length of pipe ).
31.20 (i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
31.20 (iii) Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
31.20 (v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
31.20 (vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. 31.21 (x) Galvanised iron pipe 25 mm dia on flushed.
31.22(i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
31.22(ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
31.22(xi) Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
31.22(xvii) Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 31.26 (xxviii) Ard. 70 Sq. mm 3.5 Core Cable .
31.26 (xxx) Ard. 120 Sq. mm 3.5 Core Cable .
31.26 (xxxix) Ard. 10 Sq. mm 4 Core Cable .
31.26 (xIi) Ard. 25 Sq. mm 4 Core Cable .
31.26 (xIii) Ard. 35 Sq. mm 4 Core Cable .
31.26 (xIii) Un-ard.35 Sq. mm 4 Core Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 31.28 (ii) 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
31.28 (iii) 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
31.28(iv) 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core .
31.28 (v) 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core
31.30 (III) ( xv ) Supply and erection of 32 mm dia meter 1.5 metre long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clamps including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections .
31.30 (IV) Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangemrnt , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections .
31.31 (a) (ii) Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S.sheet fixed with rag bolts on wall or on existing pedestal / angle iron frame including bonding to earth , detatchable top and bottom painting and necessary connections etc.(Copper bars duly tinned ). 100 amp. 4 bars of 55 cm each (cross section 25 mm x 3 mm) chamber over all size 60 cm x 45 cm x 18 cm .
31.31 (a) (iv) 200 amp. 4 bars of 55 cm each (cross section 25 mm x 5 mm) chamber over all size 60 cm x 45 cm x 18 cm .
31.35 (i) (b) Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 20 mm dia .
31.35 (ix) Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm .
31.38 Wiring only in 1.5 Sqmm PVC insulated copper conductor cable in existing conduit pipe and MS boxes covered with 5mm thick bakelite sheet including cost of switch, wall socket, ceiling rose etc. Fan Point Short point
Medium Point
Long point.
Light Point Short point
Medium Point
Long point.
Call bell point Long point.
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point
Medium Point
3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc. Long point.
31.40 Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe . Size 1.5 sqmm ( 3/0.81 )
Size 2.5 sqmm ( 3/1.05 )
Size 4 sqmm ( 7/0.85 )
Size 10 sqmm ( 7/1.35 )
31.41 Supply and erection of Double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4-way , SP&N ( Horizontal)
8-way , SP&N ( Horizontal)
12-way , SP&N ( Horizontal)
4-way , TP&N ( Horizontal) (8+12)
8-way , TP&N ( Horizontal) (8+24)
31.44 Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 25 mm dia.
31.48 Supply and erection of MS Saddle and clamps duly galvanised , on wall / RCC parapit for fixing underground cable at a distance of 0.60 metre center to center fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work.
31.53 Supply and erection of 50mm diameter 1.5mtr. Long GI bracket (B-Class) making an angle 10 to 15 degree with horizontal plane for mounting street light fitting on GI bracket on wall with 2 Nos. 50mmx3mm thick MS flat including cost of cutting welding of GI pipe complete with cement sand mixture bolts and nuts etc. including making necessary connection with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work.
31.55 Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer-in-Charge of the Work.
31.56 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp. 1 way switch
20 amp. switch
10 amp. Socket
16 amp. Socket
Bell Push
Fan Regulator
Blanking plate.
31.57 Providing and fixing GI concealed sheet metal boxes with inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respect. 1 & 2 Modules
4 Modules
6 Modules
8 Modules
12 Modules
31.67 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work HDPE pipe 63 / 50mm outer dia / inner dia.
Ms Royal Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .