Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹46.3 L+₹94,282.80 (2.08%)Rejected-AOC HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹47.8 L+₹2.5 L (5.49%)Rejected-AOC | L3 | Rejected-AOC Higher bid value |
| Sl No | Description | Qty | Unit | VAISHNO ASSOCIATES L2 | M/S ORIENTAL MOTORS COMPANY L3 | M/S MUGHATOLI AYE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. | 39 | Cum | 620 ₹24,180 | 630 ₹24,570 | 600 ₹23,400 Lowest |
| 2.00 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. | 23 | Each | 85 ₹1,955 | 83 ₹1,909 | 80 ₹1,840 Lowest |
| 3.00 | Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. | 11 | Each | 130 ₹1,430 | 135 ₹1,485 | 120 ₹1,320 Lowest |
| 4.00 | Taking down shutter not exceeding 1 Sqm each complete all as specified and as directed. | 5 | Each | 85 ₹425 | 83 ₹415 | 80 ₹400 Lowest |
| 5.00 | Taking down shutter of any description exceeding 1.0 Sqm nexc 2Sqm each complete all as specified and as directed. | 2 | Each | 150 ₹300 | 148 ₹296 | 100 ₹200 Lowest |
| 6.00 | M&L for second class hardwood as in scantlings clean sawn timber fixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed. | 0.65 | Cum | 55,500 ₹36,075 | 55,550 ₹36,107.5 | 55,000 ₹35,750 Lowest |
| 7.00 | All as per Ser item No 6.00 (here-in-before) but except timber complete all as specified and directed. | 0.2 | Cum | 10,150 ₹2,030 | 10,250 ₹2,050 | 10,000 ₹2,000 Lowest |
| 8.00 | M&L 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement and surface finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including provn of GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. | 74 | Sqm | 480 ₹35,520 | 490 ₹36,260 | 475 ₹35,150 Lowest |
| 9.00 | Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed. | 68 | Sqm | 120 ₹8,160 | 125 ₹8,500 | 100 ₹6,800 Lowest |
| 10.00 | M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed and bird proofing in walls incl all laps cutting and waste complete all as specified and as directed. | 92 | Sqm | 255 ₹23,460 | 170 ₹15,640 Lowest | 250 ₹23,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Dec 2025, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPL REPAIR TO BLDG NO T 55 IN N ZONE SPL REPAIR TO BLDG NO T 36 AND T 39 OF 1 COY 15 EW BN PROVN OF PATHWAY ALONGWITH COVERED SHED FROM BLDG NO T 9 TO OPT 24 IN F ZONE AND ADDN ALTN OF FLOORING FOR BLDG NO P 487 AND P 486 IN E ZONE
2025_MES_743681_1
8947/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Class D
Category a(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹90,000
20 Feb 2026
9 Dec 2025
31 Dec 2025
9 Dec 2025
29 Dec 2025
22 Dec 2025
9 Dec 2025 - 16 Dec 2025
M&L for second class hardwood as in scantlings clean sawn timber fixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed.
All as per Ser item No 6.00 (here-in-before) but except timber complete all as specified and directed.
M&L 12 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed.
M&L 25 mm thick PCC type B-0, 1:2:4 (using 10mm graded stone aggregate) as in sub base of flooring finished even and fair using extra cement complete all as specified and as directed.
M & L for PCC (1:2:4), type B-2, 100 mm thick (using 40 mm graded stone aggregate) as in hardstanding, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Abrasion resistant self-levelling epoxy floor coating with solventless epoxy 3mm thick (2mm Screed and 1mm top coat) withstand attacks by oils lubricants, alkalis,acids,water, abrasion and impact like no other polymers with excelent bonding properties applied with following methods complete all as specified and as per manufactures instruction and as directed by Engineer in Charge. :- (i) Cleaning and Surface Preparation. (ii) Primer Coating (iii) Cracks and joint filling (iv) Epoxy finish coating
M&L for light shade coloured vitrified ceramic tiles 8-9mm thick (Square / rectangular) of area exceeding 0.36sqm but not exceeding 0.42 Sqm each, in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in Cement Mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
S&F steel work in tubular trusses, post, purlins including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240 complete all as specified and directed by Engineer - in – Charge
S&F anodised aluminium powder coated section as in aluminium frame for doors, windows, ventilators including shutters,with one or more rebates including joining cleat for fixing complete all as specified and as directed. Note:- Necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc are deemed to be included in quoted rates.
M&L for second class hardwood plain fillets exc 13sqcm and not exc. 25sqcm, square or rectangular in section, wrought, secured with nails or brads complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of primer on new plastered surfaces of walls including preparation of new surface complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer over 2mm thick of wall care putty(in two layers) on wall surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coat of exterior weather paint over one coat of primer over a coat of 2mm thick wall care putty on wall surface complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for cement concrete type B-1 (1:2:4) (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed.
M&L for PCC 1:4:8 Type D-2(using 40mm graded aggregate) 75 mm thick as in sub base finished even and rough
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A including dismantling of old steel from its position complete all as specified and as directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to GDE Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-painted self embossed, textured designer board E-Board Classic to be fixed or laid with GI frame grid/section size 600mm x 600mm with main runner 38x24x0.9 mm thick, cross tee 8.6x24x0.9mm and wall angle 19 x19x0.9mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size including dismantling of old unsv ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets of any description and at any location complete all as specified and as directed.
S&F in repair aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts wells cesspits man-holes pier holes etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2, (using 40mm graded stone aggregate) and paving 100 mm thick complete all as specified and as directed.
S&F mild steel screw bolts of diameter of neck 16 to 20 mm (machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length of bolt exc 22.5 cm and n exc 30 cm long complete all as specified and as directed.
M&L for chequered cement concrete tiles of size not less than 300x300x25mm thick laid over and including 15mm thick screed bed for laying floor finishes in cement mortar 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and as directed.
M&L for Point wiring in repairs complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. as required at site and 50 mm deep complete all as specified and as directed.
One light point controlled by one, one way switch .
One Exh/Ceiling fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No-99.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
S&F Switch piano flush type single pole, one way 5A complete all as specified and as directed.
S&F Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 5A flush type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and as directed.
S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and as directed.
M&L for sub main wiring with two runs of 4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including taking down old unsv one complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length
S&F in repairs LED Light fitting 1 x 20 watt (4 Ft), basic all purpose surface and wall mounted LED battern with polycarbonate housing & intergrated electric driver with all accessories incl connecting up with and incl twin/ three core twisted flexible copper conductor cable of suitable size in and incl flexible hose from ceiling rose to fitting complete all as specified and as directed.
S&F in repairs LED Light fitting 1 x 10 watt (2 Ft), Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with, including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core and flexible pipe from ceiling rose to the light fitting complete all as specified and as directed.
Supply , fixing and testing in repairs/replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with and including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed.
S&F in repairs/replacement for Decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 base complete all as specified and as directed.
S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker TPN 40 to 100 Amp (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F in repairs MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed
S&F in repairs MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F in repairs MCB SP 5-40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
Taking down carefully exisiting water heater storage 25 Ltrs Capacity, PVC connection GI Tubes, Bip taps, and stop valve safecustody and refixing, testing after compltion of the work complete all as sp
ecified and as directed. Note : All fansteners Nut and Bolts deemed to quoted rate.
Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore complete all as specified and as directed.
S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F 15mm bore Bib tap fancy type chromium plated with long shank complete all as specified and as directed .
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core including taking up/down old unsv one complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core including taking up/down old unsv one complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall only be measured and paid.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tender8947.pdf
Tender Documents • 1.66 MB
BOQ_832714.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .