| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.5 L+₹7.0 L (31.3%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹32.0 L+₹9.5 L (42.1%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹34.0 L
EMD Value
₹67,940
Closing Date
28 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Amritsar
CWE Amritsar Old Cantt Amritsar
SPL REPAIR REPLACEMENT OF BER VACCUM CIRCUIT BREAKER OF 11 KV CAPACITY FOR MAIN RECEIVING STN AT UNDER GE GURDASPUR
2021_MES_472267_1
CWE/ASR-30/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Gurdaspur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Gurdaspur
₹67,940
Yes
24 Nov 2021
2 Sept 2021
5 Oct 2021
2 Sept 2021
28 Sept 2021
16 Sept 2021
90 days
Amount
Taking down carefully including disconnecting existing, totally enclosed metal clad switchgear from Sub Stn and deposit in MES Store Yard for safe custody all as directed by Engr-in-Charge
Supplying, installing, commissioning & testing HT 11 KV, 3 Phase 50 Hz, rupturing capacity 350 MVA, indoor type, totally metal clad with-drawable type Vacuum Circuit Breaker outgoing panels with copper bus bar of suitable rating horizontal isolation type VCB of capacity 1200 Amps rated current as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with CRCA sheet not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing section and shall be totally dust and vermin proof. The panel shall be tested for IAC level 25 kA No of operation of Vacuum Interrupter Bottles for better performance (i) Mechanical life – 30,000 cycles (ii) Rated electro -mechanical operations – 10,000 Cycles (iii) Rated Short Circuit current – as per IEC 622271-100-200. VCB parameters are as below: (i) Rated voltage level/PF withstand voltage/Impulse level 12KV/28KV/75 KVp (ii) Continuous current rating minimum 1200 Amp (iii) Short circuit withstand current rating minimum 25 KA for 3 seconds (iv) 01 No. minimum 1200 amps horizontal draw out type vacuum circuit breaker in 12 KV metal clad floor mounted panel complete with following : - (a) Manually & motor operated(230V AC,50 Hz) spring charged type, manually and electrically open (electrical (220VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication “OFF’ push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in C5 service position.
Supplying, installing, commissioning & testing HT 11 KV, 3 Phase 50 Hz, rupturing capacity 350 MVA, indoor type, totally metal clad with-drawable type Vacuum Circuit Breaker outgoing panels with copper bus bar of suitable rating horizontal isolation type VCB of capacity 630 Amps rated current as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with CRCA sheet not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing section and shall be totally dust and vermin proof. The panel shall be tested for IAC level 25 kA No of operation of Vacuum Interrupter Bottles for better performance (i) Mechanical life – 30,000 cycles (ii) Rated electro-mechanical operations – 10,000 Cycles (iii) Rated Short Circuit current – as per IEC 62271-100-200. VCB parameters are as below: (i) Rated voltage level/PF withstand voltage/Impulse level 12KV/28KV/75 KVp (ii) Continuous current rating minimum 630Amp (iii) Short circuit withstand current rating minimum 25 KA for 3 seconds (iv) 01 No. minimum 630 amps horizontal draw out type vacuum circuit breaker in 12 KV metal clad floor mounted panel complete with following : - (a) Manually & motor operated(230V AC,50 Hz) spring charged type, manually and electrically open (electrical (220VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication “OFF’ push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in C5 service position.
M & L for arrangement of standby electric supply to the incoming and outgoing feeders for the shut down period till commissioning and functioning of new VCBs complete. Note:- The cost of the rental VCBs & connection to the existing system to give interrupted power supply to the whole cantt is deemed to be included in the quoted rate of contract. Note : (i) In case of any interruption /background in the rental/stand by VCB, the VCB should be make opernation by 2 hrs of time frame, failing which a penalty of Rs. 2000/- per hours will be levied on the contractor.
Supplying and laying synthetic Rubber insulated mats 2.5mmthick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safetyof size 2m x 1 mtr
Material and Labour for earthing complete with GI earth plate electrode 600mm x 600mm, 6mm thick, burried in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate to a depth not lesss than 1.5 meter below the ground level, earth plate surrounded by 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth strip of size 32 x 6 mm by means of GI nuts, bolts and washers. Earth conductor strip laid in 40 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) Test point of GI strip of size 32mmx6mm. (b) Watering pipe of GI pipe light grade 20mm bore (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for lifting of pit cover (d) Frame of cover made of 40x40x4 mm angle iron Note:- (i) The cost of excavation & earth work shall be included in the quoted rates. (ii) Earth lead beyond 7.5 m from electrode to earth terminal shall be measured separately (iii) On testing, after completion, if desired earth resistance is not obtained, the earthing will be redone at no extra cost and quoted rates shall be to include this aspect.
Supply, laying, testing & commissioning in replacement HT UG XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electic cable with stranded aluminim conductor 11000 volts (Earthed) grade of crossectional area 185 Sqmm 3 core laid in trenches/ducts/through pipes/in floor road/along the pole etc all as specified & directed by Engr-in-charge.
M&L for end termination indoor 11 KV Alumunium (Earthed) grade cold shrink type jointing kit complete with jointing material and acessories suitable for 3 core XLPE armoured conductor cable of size 120 to 185 Sqmm all as specified and directed.
kailu construction co
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .