Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | ₹38.1 L Quoted ₹43.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹44.7 L+₹1.7 L (3.96%)Rejected-Finance | ₹44.7 L+₹1.7 L (3.96%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹47.3 L+₹4.3 L (10.1%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹47.3 L+₹4.3 L (10.1%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹48.9 L+₹5.9 L (13.8%)Rejected-Finance | ₹48.9 L+₹5.9 L (13.8%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹49.8 L+₹6.8 L (15.9%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | ₹49.8 L+₹6.8 L (15.9%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
9 May 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR AND MAINT OF CEILING FAN, EXHAUST FAN, HEATING APPLIANCES, SOLAR APPLIANCES AT ZONE-I AND ZONE-II UNDER THE JURISDICTION OF GE (A) JAISALMER
2022_MES_517775_1
8174/22-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,000
Yes
23 Jun 2022
12 Apr 2022
11 May 2022
12 Apr 2022
9 May 2022
25 Apr 2022
Amount
Supply & fix including taking down for the following items in :-
(a) Fan condenser, 2.5 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp complete all as specified and directed by Engineer-in-charge.
(b) Fan condenser, 4 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp complete all as specified and directed by Engineer-in-charge.
(c) Fan regulator electronic Modular step type, 120 watts, 1 module/2 Module complete all as specified and directed by Engineer-in-charge.
(d) Steppped type electronic fan regulator flush type on the existing sheet 120 watts, complete all as specified and directed by Engineer-in-charge.
(e) Rubber reel insulator, 3 Nos nut bolt, washer and lock pin complete all as specified and directed by Engineer-in-charge.
(f) Ceiling fan blade complete all as specified and directed by Engineer-in-charge.
(g) Exhaust fan blade size up to 450 mm complete all as specified and directed by Engineer-in-charge.
(h) Ceiling fan hook for fixing fan complete all as specified and directed by Engineer-in-charge. Note :- Rate quoted by the Contractor shall deemed to inclusive of chipping of RCC slab for exposing of reinforcement and insertion & taying of fan hook and making good the disturbed surface to match with existing specification.
(j) Ceiling fan downrod suitable size with brass bolt and nut, GI hook/pin as per requirement of site of any size complete all as specified and directed by Engineer-in-charge.
Taking down ceiling fan / Exhaust fan/Wall mounted fan/Air circulator fan of any sweep sealing cable ends dismanting blade and removing fan and blade to store complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for ball bearing suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for ball bearing suitable for exhaust fans up to 450mm size complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for brass GM bush suitable for fan any size complete all as specified and directed by Engineer-in-charge.
M & L for rewinding of fan of any sweep with supper enameled copper wire of gauge as per existing winding including varnishing and drying complete reassembling & testing complete for following sizes all as specified and directed by Engineer-in-charge.
(a) Ceiling fan of size 1200/1400 mm Sweep
(b) Exhaust Fan of size 250/300/380 mm
(c) Exhaust Fan of size 400/450 mm
(d) Wall mounted fan 450 mm Sweep
(e) Air circulator 600 mm sweep
M&L for Painting to ceiling fan/exhaust fan complete in situ as per existing colour with one coat of synthetic enamel paint by using mechanical spraying including filling cavity with filler after cleaning all dust etc complete all as specified and directed by Engineer-in-charge.
Fixng only ceiling fan and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-charge.
Fixng only exhaust fan/Wall Mounting/Air circulator and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-charge.
Taking down storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/50 ltrs of any type and make, in MES store Yard complete all as specified and directed by Engineer-in-charge.
Refixing storage type water heater storage type capacity 25/50 ltrs of any type and checking the serviceablity of all parts of such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge. Note :-Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below.
Supply & Fix including taking out for heating elements, 1.5 KW ISI mark 230 volts complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking out for heating elements, 2 KW ISI mark 230 volts complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for thermostat immersion point ,Length 175 mm to 250 mm, Temperature 0 to 75 degree C, 230 volts/AC complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of safety valve for 25/50 ltr geyser complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of pressure releasing valve for 25/50 ltr geyser complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for Metal clad plug top and socket, 3 pin, 20 Amps complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for Three pin plug top, 16 amp capacity, 240 VAC, heavy duty complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for MCB SP 16 Amps single pole, 230volt, 50 Hz complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for Fastners screw for fixing Geyser storage capacity 25/50 ltrs of any type and make complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of PVC connection pipe duly chromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete , length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified and directed by Engineer-In-Charge.
Supply & Fix including taking down for replacement of indicator lamp assembly for geyser complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of 3 core PVC insulated and sheathed cable with copper conductor of size 40/0.076 complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of inlet & outlet assembly plate suitable for 25 ltrs capacity geyser as per existing pattern complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for replacement of inlet & outlet assembly plate suitable for 50 ltrs capacity geyser as per existing pattern complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for Inner tank of geyser of 25 Ltr capacity of made out of steel tank in replecement of leakage tank of geyser complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for Inner tank of geyser of 50 Ltr capacity of made out of steel tank in replecement of leakage tank of geyser complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for STOP COCK cast copper alloy, screwed down high pressure screwed both ends for iron pipe of 15 mm bore fancy type chromium plated complete all as specified and directed by Engineer-in-charge.
S & F including taking down for Bib tap chromium plated 15 mm dia cast copper alloy with butter fly handle, screwed down, screwed one ends for pipe of 15 mm dia complete all as specified and directed by Engineer-in-charge.
Dismantling old defective FPC solar water heater collector of any type any make complete all as specified and directed by Engineer-in-charge.
Taking down of Old U/S hot water tank of any capacity any make complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 200 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 2 KW and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 150 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 2 KW and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 100 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with thermostat and heater coil 2 KW and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 200 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 20 tube holes of 58mm diameter and outer PPGI with 20 Nos of 58x1800 mm tubes , thermostat and heater coil 2 KW and suitable size of MS powder coated stand 25x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 150 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 15 tube holes of 58mm diameter and outer PPGI PUF insulation with 15 Nos of 58x1800 mm tubes with thermostat and heater coil 2 KW and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S & F MNRE registered/approved 100 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304 with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation with 10 tube holes of 58mm diameter and outer PPGI with 10 Nos of 58x1800 mm tubes with thermostat and heater coil 2 KW and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engineer-in-charge.
S&F including taking down tubes of Evacuated tube collector (ETC) type 1800mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engineer-in-charge.
S&F including taking down tubes of Evacuated tube collector (ETC) type 2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete all as specified and directed by Engineer-in-charge.
Taking down of old U/S rusted MS structure of solar water tank any type any shape complete all as specified and directed by Engineer-in-charge.
Taking down of old U/S rusted MS structure of cold water tank any type any shape complete all as specified and directed by Engineer-in-charge.
S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like includind caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates grade Fe-290 (Gde E-165), including all lattice bars, stiffeners, gusset plates etc welded together, anchor duly painted with two coats of synthetic enamel paint over and coat of red oxide primer and and forming PCC work and 12mm thick etc complete to avoid any deformation complete all as specified and directed by Engineer-in-charge.
Taking down old U/S , broken pipe of any type any size complete all as specified and directed by Engineer-in-charge.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete of size 20mm including union, bends and tees complete all as specified and directed by Engineer-in-charge.
S&F including taking down for heating element for solar water heating system of capacity 3 KW complete all as specified and directed by Engineer-in-charge.
S&F including taking down for heating element for solar water heating system of capacity 2 KW complete all as specified and directed by Engineer-in-charge.
S&F including taking down for thermostat suitable for 100 to 500 litres capacity of solar water heater complete all as specified and directed by Engineer-in-charge.
Dismantling & taking out the unserviceable Gun-metal, globe or gate valves of any size from geyser/solar connection pipe complete all as specified and directed by Engineer-in-charge.
S&F for Gun-metal, globe or gate valves, with iron wheel head ,screwed both ends from iron pipe and fixed size 15 mm complete all as specified and directed by Engineer-in-charge.
S&F for Gun-metal, globe or gate valves, with iron wheel head ,screwed both ends from iron pipe and fixed size 20 mm complete all as specified and directed by Engineer-in-charge.
S&F for Gun-metal, globe or gate valves, with iron wheel head ,screwed both ends from iron pipe and fixed size 25 mm complete all as specified and directed by Engineer-in-charge.
Supply & Fix including taking down for rotational moulded synthetic (HDPE) water storage tank with float valve 20mm brass of capacity of 500 litre capacity triple layered, cylindrical vertical with closed top hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed by Engineer-in-charge.
S&F including taking out Ball brass valves, high pressure, with polythene float valve 20mm and flynut complete, screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S & F including taking out for GI tubing 20 mm dia medium grade galvanised with necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings complete all as specified and directed by Engineer-in-charge.
S & F including taking out for GI tubing 15 mm dia medium grade galvanised with necessary fittings such as tees, elbows, bends, reducers, union etc laid in wall ceiling & Floor including all fittings complete all as specified and directed by Engineer-in-charge.
S & F including taking down sheet metal single pole and neutral enclosure with a two pin and eath plug and socket complete with one single pole MCB 20 Amp 240 V complete all as specified and directed by Engineer-in-charge.
M & L including taking down for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (Note :- Two runsof 4.00 Sqmm cable & one run of 4.00 Sqmm cable shall be paid as one unit length)
M & L including taking down for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in PVC casing caping including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
M/S SUMAN ENTERPRISES
M/s Shree Construction Company
Leelashah Enterprises
M/s Yash Electrical and Maintenance
JAI ENGINEERING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .