Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹34.3 L+₹17,996 (0.53%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹34.6 L+₹52,020 (1.53%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹37.9 L+₹3.8 L (11.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹40.7 L+₹6.6 L (19.5%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
29 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR / CLEANING OF SEWAGE LINES, SEPTIC TANKS AND SOAKAGE WELLS AT AURANGABAD UNDER GE (S) AHMEDNAGAR
2023_MES_587960_1
8967/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
12 May 2023
1 Apr 2023
1 May 2023
1 Apr 2023
29 Apr 2023
15 Apr 2023
1 Apr 2023 - 8 Apr 2023
Amount
Labour only for removing blockage of WC (Indian or EWC), urinal, bath and kitchen, gully trap including cleaning of pan, floor trap and removing blockage of down pipe upto first manhole complete all as specified and as directed. Notes. (i) The item shall be operated on demand/complaint of users and shall be executed on specific written directions of Engineer-in-charge/JE. (ii) Complint shall be issued on dockets which shall be returned to Engineer-in-Charge/JE on removal of blockages . All written dockets shall be serially numbered, jointly signed including user signature as token of completion with building number/quarter number and the same shall be entered in measurment book for the purpose of measurment and payment. (iii) A recovery of Rs. 200/- for each complaint shall be deducted from the payment due to the contractor in case the complaint is not attended and blockage is removed within 24 hours. Decision of GE shall be final and binding in this regard.
Cleaning of SGSW/RCC pipe line upto 150mm dia between manholes by mechanical operated machine for removing blockage, debries from pipes taking out the blocked sludge debries etc collected in the manholes from pipe, cleaning and depositing sludge/debries to excavated pit/area, spreading necessary insecticise where sludge is deposited and covered with soil all as specified and as directed. Note:- A recovery of Rs. 200/- for each complaint shall be deducted from the payment due to the contractor in case the complaint is not attended and line is not cleaned within 24 hours. Decision of GE shall be final and binding in this regard.
All as per serial item No 2 above but for 200mm to 250mm bore pipes.
All as per serial item No 2 above but for 300mm to 450mm bore pipes.
Dewatering and removing the sludge from septic tank in covered vehicle of 25 to 50 users, cleaning the septic tank with water and removing the sludge outside th MD land, deposited in excavated pit and carrying out necessary disinfection where sludge is deposited complete all as specified and as directed
All as per serial item No 5 above but for septic tanks of capacity 100 to 150 users.
All as per serial item No 5 above but for septic tanks of capacity 200 to 500 users.
Dewatering sokage well in covered vehicle of 25 to 50 Users and removing the sludge outside the MD land & depositing, to carry out necessary disinfection where sludge is deposited all as specified and directed for septic tank of following capacity.
Excavation in trenches, n exc 1.50m wide and n exc 1.50m in depth; for foundations, etc. or for manholes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil all as specified and as directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and as directed.
Removing excavated soil to a distance exc 250m but n exc 500m and depositing where directed at a level not exceeding 1.50m above the starting point all as specified and as directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 150mm all as specified and as directed.
All as per serial item No 12 above but for 200mm bore pipe.
M&L for SGSW pipes, grade 'A', 150 mm internal dia, laid in trenches over plain cement concrete bed and joited and pointed in cement mortar 1:1 complete and jointed complete all as specified and as directed. Note: Excavation, earthwork and PCC shall be measured and paid seperately under respective item.
All as per serial item No 14 above but for 200mm bore pipe.
M&L for 150 mm internal dia reinforced concrete pipes with collars, class NP2, laid in trenches over concrete bed, jointed with collar and complete all as specified and as directed. Note: Excavation, earthwork and PCC shall be measured and paid seperately under respective item.
All as per serial item No 16 above but for 200mm bore pipes.
M&L for cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified and as directed.
All as per serial item No 18 above but for 200mm bore pipes.
Demolition of cement concrete (reinforced) of ny description and in any position not otherwise specially provided for complete all as specified and as directed.
Demolition of brick work/precast concrete block masonary / stone masonry including coping etc complete built in cement or cement lime mortar all as specified and as directed.
M&L for cement concrete 1:4:8, type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in manhole covers including necessary forms and moulds etc and finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in copings, haunchings and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as spcified and as directed.
M&L for brick work with subclass B bricks, straight or curved on plan exc 6m mean redius built in cement mortar 1:6 complete all as specified and as directed.
M&L for TMT bars, 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as spcified and as directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F in repairs, 110mm bore PVC (SWR) bend any radius, with oval access door all as specified and as directed.
S&F in repairs, 75m bore PVC (SWR) bend any radius, with oval access door all as specified and as directed.
S&F in repairs, 110mm bore PVC (SWR) , branch piece, single (single Y) equal or unequal with oval access door all as specified and as directed.
S&F in repairs, 75mm bore PVC (SWR) , branch piece, single (single Y) equal or unequal with oval access door all as specified and as directed.
S&F in repairs, 110mm bore PVC (SWR) , branch piece, double (double Y) equal or unequal with oval access door all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) floor trap, 75mm dia of outlet, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repairs PVC (SWR) gully trap, 125/110mm, plain with grating including jointing with solvent cement and fixed in PCC 1:2:4 (using 20mm graded stone aggregate) complete all as specified and as directed.
M/S Tirupati Goroba Shendge
SKS Electricals
M/s.M G Kulkarni
sonu enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .