Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹47.0 L
EMD Value
₹94,000
Closing Date
31 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIR / MAINT OF E/M INSTALLATIONS UNDER GE (AF) MARATHAHALLI BANGALORE
2026_MES_793319_1
GE (AF) MARATHAHALLI / 8885 / E8
Open Tender
Civil Works
Item Rate
330 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹94,000
Yes
10 Oct 2026
10 Oct 2026
2 Nov 2026
10 Oct 2026
31 Oct 2026
24 Oct 2026
11 Oct 2026 - 22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down GI/acrylic sign board of any type any size from existing locations near sub station buildingss complete all as directed by EIC .Note : Demolition of pcc supports/base and earth work will me measured and paid under respective item . | 10 | Each Job | - | - |
| 2 | Supply fabricating and fixing steel board stand made of 50 mm dia stainless steel heavy duty pipe of SS 304 grade ,suitable for outdoor purpose as per site requirement for fixing aluminium composite panel of various sizes of duly lettered and emblen ,fixed with nuts ,bolts of screw or any other arrangement ,along with frame of 20 mm dia SS pipe complete all as directed by EIC .
Note :Necessary excavation and earthwork ,PCCMfor embedding pipes ,20 mm dia SS pipe for frame and ACP sheet will be measured and paid separately under respective items . | 150 | Running Feet | - | - |
| 3 | Supply,fabricating and steel board frames ,posts and connecting pipes made of 20 mm dia stainless heavy duty pipe SS 304 grade suitable for outdoor purpose boards ,as per site requirement for fixing aluminium composite panel of various sizes ,fixed with nuts bolts of screw or any other arrangement complete all as directed by Engineer in Charge .
Note :ACP Sheet will be measured and paid for separately under respective items . | 150 | Running Feet | - | - |
| 4 | Supply and fix ACP sign board sheets of not less than 4 mm (2 mm sheets sticked back to back ) of various sizes ,including writing details of installations/machinery bith sides vinyl pasting on radium sticker with self glowing letters ,emblems along with lamination on both sides as perd irections of EIC | 250 | Square feet | - | - |
| 5 | Material and labour for writing letters of size upto 2 inch height ,with exterior grade enamel water proof paint on panels/feeder fillar boxes etc including representing incoming and outgoing connections complete all as specified and directed by Engineer in charge . | 250 | Each Letter | - | - |
| 6 | Material and labour for writing letters of size upto 1.5 inch height ,with exterior grade enamel water proof paint on panels/feeder fillar boxes etc including representing incoming and outgoing connections complete all as specified and directed by Engineer in charge . | 4,000 | Each Letter | - | - |
| 7 | Painting of details with Trf Capacity ,Sr No,Model No .Manfacturing Year , on the plinth of transformer with the direction of Engineer in charge complete all as specified and as directed | 10 | Each | - | - |
| 8 | Taking down old board and S& F Display board (Earth pit marker) made out of 25 mm angular frame with 45 cm height one side welded with 2mm thick MS sheet, frame work of size 15cmx15cm including excavation , PCC foundation and duly painted with redoxide & two coats black enamel paint with following letter display with white paint earth pit marker.
a) Earthing pit No:- b) Earthing resistance:- c) E-N volt:- d) Check done on:- e) Check due On:- | 80 | Each | - | - |
| 9 | Supply Shock treatment chart as per IE rules ,size should not be less than 4 feet x 3 feet ,printing on PVC foam board complete all as specified and as directed with direction of EIC | 10 | Each | - | - |
| 10 | Supply Electrical safety rules as per IE norms,size should not be less than 4 feet x 3 feet ,printing on PVC foam boardc omplete all as specfied and as directed with direction of Engineer in charge . | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_889645.xls
BOQ • 0.33 MB
TENDER.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .