Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.9 CrAccepted-AOC PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹3.9 Cr Quoted ₹4.0 Cr | L-1 | Accepted-AOC Being lowest bidder |
| 2 | L-2₹4.4 Cr+₹47.1 L (11.9%)Rejected-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹4.4 Cr+₹47.1 L (11.9%) | L-2 | Rejected-AOC Not being lowest |
| 3 | L-3₹4.5 Cr+₹54.0 L (13.7%)Rejected-AOC | ₹4.5 Cr+₹54.0 L (13.7%) | L-3 | Rejected-AOC Not being lowest |
Tender Value
₹4.9 Cr
EMD Value
₹5.7 L
Closing Date
29 Oct 2022, 6:00 pmClosed
CE RND DELHI
HQ CE RND, Probyn Road, Delhi-110054
ADDITION/ALTERATION OF AND SPECIAL REPAIR TO EXISTING SECURITY WALL/WATCH TOWERS INSIDE TECHNICAL AREA OF ITR CHANDIPUR
2022_MES_552338_1
CE RND/DLI-14/CHANDI/2022-23
Open Tender
Civil Works
Item Rate
365 days
Chandipur
Please refer tender documents
8 documents required · 8 mandatory
₹3,000
GE I RND Chandipur
₹5.7 L
Yes
9 Dec 2022
16 Sept 2022
5 Nov 2022
16 Sept 2022
29 Oct 2022
15 Oct 2022
Amount
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filing and mass concrete complete all as specified and directed.
M & L for Brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and directed.
M & L for Hardcore of broken stone or boulders n exc 63 mm, deposited, spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M & L for Cement concrete 1:3:6, 100 mm thick as in Sub base type C2 (using 40 mm graded stone aggregate) complete all as specified and directed.
M & L for Cement concrete 1:2:4, type B0 (using 12.5mm graded stone aggregate) 50 mm thick as in floors finishing cement concrete even and smooth using extra cement complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point for soils complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1 : 4 finished even and fair on brick work or concrete surfaces (external) using water proofing compound mixed as per manufacturer's instuction all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:6 finished even and smooth on brick work or conctete surfaces (internal) complerte all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:3 finished even and smooth with out using extra cement on brick work or concrete surfaces of soffit slabs ceiling surfaces etc. all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
Demolition of unreinforced cement concrete of any description in any position not otherwise specially provided for complete all as specified and directed.
M & L for PCC 1:2:4, 50 mm thick, type B0 using 12.5 mm stone aggregate as in padding and in any situation finising even and fair for getting proper slope/covering complete all as specified and directed. (Note : PCC shall be done mixer machine only).
M & L for rendering 10 mm thick average in cement mortar 1:4 over padding of roof surfaces mixed with WPC as per manufacturer's instructions, finished even and smooth without using extra cement after preparation of surfaces complete all as specified and directed. (Note : WPC will be measered separately complete all as specified and directed).
M & L for APP based polymeric menbrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (Wt.not less than 150 gm/Sqm) laid over a coat of blown bitumen primer @0.30 Kg/Sqm and bonded completely with torch application with side over lap 75mm and enc lap minimum 100mm and sealing over lap and joints and as per mafufacturer's instruction and applying one coat of aluminum paint @ 300 ml per sqm on surface of any description/above the APP membrane and all as directed all as specified (Note : Aluminum paint shall be measured and paid separately)
Supply only aluminum paint
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1.3 to ends or edges of landings, steps, cills, sunshades, shelves, lintel etc and cutting chases not exceeding 10 cm girth in brick / stone wall complete all as specified and directed.
M & L for RCC 1:2:4 type B1(Nominal Mix) with using 20mm graded stone agg as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M & L for preparation of new plastered or un plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for Non - skid joint free coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M & L for Non - skid joint free coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10 mm thick backing coat in cement mortar 1: 4, as on vertical surfaces such as skirting, dados, etc, complete all as specified and as directed.
S & F powder coated aluminium frame for doors, windows with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F for powder coated aluminium door shutters aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing,handles 2 Nos in each door , hinges , anodised aluminium snap beading, screws etc complete all as specified and directed.
S & F for powder coated aluminium window shutter slinding type without sash bars , aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber packing, , anodised aluminium snap beading, screws , anodised aluminium fittings such as peg stays 150 mm long(1 No), hinges type B-21 100 mm long (2 Nos) suitable handle ( 1 No) in each shutter complete all as specified and directed.
S & F 5.50 mm thick tinted sheet glass n. exc 0.5 sqm in each pane fixed to windows complete all as specified and directed.
S & F 5.50 mm thick tinted sheet glass exc 0.5 sqm in each pane fixed to aluminium doors and windows frame complete all as specified and directed
M & L for preparation of old surfaces and applying one coat of synthetic enamel paint to wooden surfaces over 10 cm width or girth complete all as specified and as directed.
M&L for 30mm thick guniting work to RCC column, beams, chajjas, ceiling balconies, slabs, landing etc by removing loose concrete including removing rust with short blasting including chipping and cleaning of surfaces with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mesh not less than 95x95x3mm adhesive plaster grade to concrete admixture and providing guiniting pressure 2 to 2.5 Kg/Sqm with admixture 1 part of cement and 1/2 part sand and average making the surfaces even and smooth including necessary form work and 5mm thick plaster in cement mortar 1:4 over repaired surfaces complete and two coats of cement based paint complete all as specified and directed by Engr-in-Charge. Note : Rate of adhesive admixture wiremesh/reinforcement and cement base paint deemed inclusive in unit rate incl taking down plaster/concrete upto reinforcement.
M & L for preparation of old surfaces and applying one coat of synthetic enamel paint to steel surfaces over 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge.
Boring for Bored cast in situ straight piles 400mm dia, 9.8 metres depth in soil and getting out and disposal of spoil to a distance of 50 metres using DMC method complete all as specified and as directed.
M & L for Carrying out initial load test as per IS : 2911(part-IV) 1985 for pile 400 mm dia and 9.8 m deep complete all as specified and as directed. (a) Vertical load test for safe load in compression.
M & L for Carrying out routine load test as per IS:2911(part-IV) 1985 complete on a single pile upto 1.5 times of the designed load for pile 400 mm dia and 9.80 m deep complete all as specified and as directed.
M & L for RCC M-30 design mix with using 20mm graded stone agg as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for Formwork to sides of rough finished surface of concrete foundations, footings, bases of columns, raft and raft beams pile caps, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces of concrete etc all as specified and directed.
M & L for TMT bars 10mm dia and over cut to length, bent to shape,required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia or securing with clips etc complete all as specified and directed.
Description complete all as per item no 41 here in before, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M & L for RCC M-30 design mix with using 20mm graded stone agg as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-30 design mix with using 20mm graded stone agg as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for Formwork to sides of rough finish surfaces of concrete pillars, posts, struts, piers, columns, and stanchions fair finished surfaces of concrete etc all as specified and directed.
M & L for Formwork to sides and soffits of rough finish surfaces of concrete floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams fair finished surfaces of concrete etc all as specified and directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specially provided for complete all as specified and diected.
Dismantling barbed wire of any size and any dia all as per directed by Engr-in-Charge complete all as specified and diected.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl aii quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and diected.
Description complete all as per item No 03 here in beforeas above but except brick
M & L for rendering 15 mm thick cement mortar in cement mortar 1:4 etc complete all as specified and directed.
M&L for two coats of cement based paint over a coat alkali resistant primer on newly plastered surfaces of walls of any description all as specified and directed as per manufacturers instructions.
S & F mild steel work, Grade Fe-410-0 or Fe- 310-0, as in angle iron post including cutting tops to shape, as directed for drilling holes notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc, including suitable fixing arrangement of struts to the existing post complete all as specified and as directed.
M & L for Providing and fixing concertina spiral coil fencing with punched tape concertina coil 600mm dia and 6 m max openable length, upto 3 m height of wall with angle iron Y shaped or as described with 9 horizontal R.B.T. reinforced barbed wire stud tied with G.I. staples and G.I. clips/ GI Cotter Pin to retain horizontal, incl necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engr - in - Charge, with reinforced barbed wire tape (RBT)/spring core (2.5mm thick) wire of tensile strength of 165 kg /sqmm with tape (0.52mm thick) and weight 43.47gm/m. (Note : barbed wire shall be measured separately)
S & F for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed.
S & F for framed work of Fe 410-W (Gde-E-250) Quality - A, as in doors or gates of angle or other section with gusset plates, braces etc complete drilled for fixing of steel sheeting or other covering. Doors to be prepared for hangidng or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section , including taking out embedded in concrete/brick wk portion and making good disturbedf ground.
M & L for Providing, cement concrete 1:3:6 type C1 as in roof kerbs or mud stops, rounded or champered on edges as in coping complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L complete removal of existing treatment from wall surfaces and applying two coats of cement based paint over a coat alkali resistant primer on old plastered or unplastered wall surfaces of walls including preparation of surfaces, complete all as specified.
M&L point wiring using FRLSH grade PVC insulated, unsheathed, stranded copper conductor of size 1.5 sqmm and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed stranded copper conductor as earth continuity wire to be drawn in and including non metallic rigid PVC conduit concealed in wall including cutting and chassing the wall as per site requirement and making good disturbed surface of wall complete all as specified and directed as under:-
One light point or one fan point controlled by one switch with cables 1.5 sq.mm size
One 5 Amps switch socket combination on independent board
S&F switch piano flush button one way 05/06 Amp complete all as specified and directed.
S&F socket out let 2 in 1, 3 pin 5 amps flush type
S&F ceiling rose surface type bakelite 65x50mm with three terminals
M&L submain wiring using two runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire concealed in wall and to be drawn in and including PVC conduit 25mm dia including cutting and chassing wall surface as per site requirement all as specified and directed.
S&F MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, SPN 4 way 240 V, flush in wall including making good disturbed surfaces complete all as specified and directed.
S&F MCB, SPN 6-32 Amps rating 240V, 'C' series, 10 KA, including taking out old
S&F MCB, SP 6 to 32 Amps, 240V, 'C' series, 10 KA, including taking out old
S&F durable LED T-8 tube light fittings 1x18 watts (4Ft) in extruded surface/suspended water proof industrial luminiare with polycarbonated housing with diffuser complete with decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S&F cabin fan, heavy duty 300mm sweep oscillating type with regulator with hanging cords, AC, 230 V and connecting up including provision of copper and flexible 3 core of size 0.5 Sqmm and OVC connector block complete all as specified and directed.
M&L earthing with galvanized steel earth plate electrode of size 600mmx600mmx6mm buried directly in ground connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alterantive layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1, 1:3:6 (using 20mm graded stone aggregate), 50,mm thick precast RCC type B1(1:2:4)(using 20mm graded stone aggregate) pit cover reinforced with 8 mm dia deformed bar and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc. 50 mtr and necessary connection and testing complete all as shown electrical plate No.3 of SSR Part-I, 2009 complete all as specified and directed.
Supply and fixing 3 runs of PVC insulated FRLSH copper conductor cable using (2x1.5sqmm + 1x1.5 sqmm) ingle core wire for connection of street light fitting from junction box to street light and drawn in non metalic rigid PVC conduit of size 20 mm dia fixed on pole including taking down unserviceable old wire and conduit complete all as specified and directed.
S&F LED flood lights with driver and SPD of capacity 150 Watts SMD with pressure die-cast aluminium housing complete with all accessories connected to power supply point with suitable length of wire, separate connector box control switch complete all as specified and directed.
S&F timer switches astro type (having longitude and latitude of Indian cities in memory) 250 volts single phase of 20 Amps rating with contractor fitted inside steel enclousers complete all as specified and directed.
Supply and laying testing cable XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core.
M&L for local sand coushing with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable & 150 mm sand after laying the cable and filling the sand in cable duct inside the sub station building complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and fixing high beam revolving LED 200 watts search light suitable for view range not less than 500 mtr, all weather proof IP-65 grade and suitable for mounting on watch towers, manual rotation in all directions and comprising of mounting base for 360 degree swivelling operation, high efficiency LEDs,free from UV interference, narrow bean angle 5 degree, life more than 1,00,00 burning hours, instants illumination by LED high reflective mirror back lense/reflector suitable to fit in various stands as per use with UDCA mounted stand suitable for mounting of light on roof of the watch towers. The height of UDCA will be 1.5 mtr (or as per requirement) and their operating lever will be mounted at suitable height so that luminary can be operated easily from inside of the cabin (i.e., below the roof of watch tower . The UDCA stand will be well designed so that the search light can be rotate one round around its vertical axis with 30 degree tilting & locking facility at the position complete all as specified and directed.
S&F air termination single pointed aluminium rod 12 mm dia and 300mm long all including fixing materials required for fixing at hanger roof all as specified and directed.
M&L test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed.
S&F steel tubing, light grade, galvanised with all fittings, 40 mm bore 3 m long the roof by making base of PCC (1:2:4) type B-1 block of 300mmx300mmx300mm for fixing of GI pipe complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60x60cmx6.0 mm thick electrode as buried directly in ground (earth pit not less than 3 mtr below normal ground level connected to GI earth strip 32mmx6mm thick by means of bolts nuts, check nuts and washers at complete etc all as shown in elecyrical plate No-3 of SSR part-I connected to earthing test point all as specified or indicated including PCC pit in PCC (1:3:6) type C-1 cast iron frame 50 mm thick pre cast RCC (1:1½ :3) nominal mix cover slab reinforce with 8mm dia mild steel bar including necessary excavation earth work in soft/loose soil and disposal of soil to a distance n.exc 50 mtr and funnel with 20 mm bore ligh gradewatering pipe wire mesh and light grade GI protection pipe 40 mm bore including testing complete including taking out old unserviceable earting material complete all as specified and directed.
M&L for aluminium strip of size 25x3.15 mm with saddle and fixing screw and porcelain insulator for roof conductors and down conductor above ground.
M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otehrwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and driected.
M & L for rendering 15 mm thick in cement mortar 1 : 4 finished even and fair on brick work or concrete surfaces (external) using water proofing compound mixed as per manufacturer's instuction with and including wire netting (chicken mesh) of galvanised steel wire 1.40 mm dia fixed with tinned tacks/nails and wire staples and size of mesh is 20 mm complete all as directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m deep and not exc 1.5 m wide wide and getting out in soft /lose soil for laying of cable all as specifed and directe.d
BLANK
LIRA CONSTRUCTIONS PVT LTD
CHHABINDRA KUMAR PRADHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .