Supply, installation, testing and commissioning of Telecom material in connection with "Ratlam Division: - Augmentation, upgradation of Telecom infrastructure with MPLS NOC at DRM office premises and reliability improvement by replacing telecommunication gears."
SnT-RTM-26-Tele-11~WR
SnT-RTM-26-Tele-11
Open
Works - General
12 Months
Ratlam, Madhya Pradesh
₹0
₹7.6 L
30 Jun 2026
27 May 2026
16 Jun 2026
B1-SOR execution
B2-NS execution
Item Breakup - A1-SOR supply
180.00 length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.
80.00 Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer.
450.00 2004 or latest; 100mm dia. (int. Dia) 3.65 Metre mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. Total 2552156.40
Item Breakup - A2-NS supply
Supply of Thermo shrink Universal Numbers Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. Inspection by RDSO.
Supply of Thermo shrink Universal Numbers Jointing kit (TSF-1) for PIJF Cable (For 10/20 pair) as per RDSO Spec No. RDSO/SPN/TC/57/2015, Rev.1, Amd.1 or latest. Inspection by RDSO.
Half Round RCC pipes & collars of 150 Numbers mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type
Supply of Two transformer type (2T) VF Numbers transformer derivation and termination of underground cable circuit Impedance ratio is 470:1120 as per RDSO specification no. IRS:TC- 76/2021 or latest (Cylindrical type)
Supply of Permanently Lubricated (PLB) Metre High density polyethylene (HDPE) Telecom duct for use as underground cable conduits -40/33 mm as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev.2.0 amnd 1,2,3 or latest. (Necessary coupler and bend included in above) RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 2 x 24 fiber optic fiber splice Numbers straight joint enclosure (SJC) complete with all accessories. As per RDSO/SPN/TC/ 68/2014 Rev.3 or latest amendment.
Supply of 6 Pin Emergency Socket as per Numbers RDSO/SPN/TC-42/20. Suitable to existing Emergency socket box installed in division.
Supply of Emergency Socket Box Asper Numbers RDSO DRG No TCA-20060(ADV) EMERGENCY SOCKET BOX IN M.S. MATERIAL BODY WITHOUT 6-PIN EMERGENCY SOCKET. Make: -EPSILON/ BENTRON/ ACES/TELECOM MANUFACTURING.
Supply of Fault Analyser Equipment as Numbers per given technical specification.
Supply of Remote end Dual sim 4g Numbers wireless router as per specification
Supply of Software license for Far end Numbers Dual sim 4g wireless router with lifetime validity (unconditional)
Supply of OFC patch chord with ST/SC/LC Numbers connector at one end ST/SC/LC connector at another end as per site requirement (suitable for media convertor/ SFP supplied) & length of patch cords 10 meters as per RDSO/SPN/TC/69/2007 Rev. 1.0 or latest
Supply of Standard 19" Rack Mountable Numbers LER(Label Edge Router) ,IP- MPLS Router with Redundant DC power feed-48V DC nominal, equipped with interfaces: 2 x 10G(optical) SFP+ Ports along with 2Nos of 40 Kms 10G SFP+ LC Modules, 4 x 1GbE (Optical)interface along with 4 Nos of 1GbESingle Mode Bi-directional SFP(10KMs) Modules and 4 x 1GbE(Copper) interfaces & Modules and slot for 16 x E1 (G.703), {supply of16 E1 card is not included in this item}, Mounting kit with all necessary accessories & Software, Perpetual Licenses. As Per RDSO Document No. STT/TAN/IP-MPLS/2020 Version 01. (Router should be compatible to existing router installed in division) {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply of 100G QSFP28 Module with 80 Numbers Km range for above MPLS Routers as per specification attached.
Supply of 8 port Manageable POE switch Numbers with 2 SFPs and its standard installation as per specification {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply of HDMI Copper Cable 10 mtr long Numbers Supported up to 4K ,.With Following Specification- 1) Support-4K , 2)Version- V2.0, 3)Band width- 18Gbps, 4)Warranty- Minimum 1 year Make- Impression or superior RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 19" covered racks ,Valrack/ Numbers Vero president/Rittal/APC/D link make or similar having size of approximately 2.2 mtr . (42U) height X 800 mm width X 800 mm depth as per specification
Supply of 24 Port LIU Rack Mountable Numbers loaded connector of SC type as per instruction of Engineer in charge. The Contractor should supply all miscellaneous items like connector pigtails etc. for complete installation of the fixed optical fiber interconnection unit as per specification.
Supply of CAT-6 cable of Dlink, Digisol, Metre Securenet,paramount, polycab make (with identification mark/ferrules etc.)
Supply of White PVC Pipe of dia 1 Inch of Metre as per Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
Supply of 35 Sq mm Multi-strand Single Metre Core PVC insulated Copper Cable asper IS: 694 for connecting Main Earth Electrode to MEEB in the equipment room.
Supply of 24V and 48V Type 3 SPD Class Numbers D for data and communication lines with impulse current rating Iimp 5 KA, nominal discharge current In 5 KA, maximum discharge current Imax 20 KA, with indicative type LED indication and pluggable module for easy maintenance, conforming to RDSO SPN 144 2006. Make- Citel Model No. DLAS1 24D3 and DLAS1 48D3 or ABB or Phoenix contact or schneider electric. make should be approved by engineer in charge.
Supply of Type 3 SPD Class D for coaxial Numbers line for RF and VHF applications with impulse current rating Iimp 1 KA, nominal discharge current In 5 KA, maximum discharge current Imax 20 KA, having frequency range DC to 3.5 GHz and removable GDT for easy maintenance, conforming to RDSO SPN TC 98 2011. Make- Model No. P8AX25 B MF or P8AX25 N MF or P8AX25 U MF or ABB or Phoenix contact or schneider electric. make should be approved by engineer in charge.
Supply of Class B and C SPD for 230 V AC Numbers system for IPS input with impulse current rating Iimp 25 KA for L to N and 50 KA for N to PE, with box and internal wiring, conforming to RDSO SPN 165 2012 or latest. Make Model No. DS260RS 230 plus DS100EG 600 plus DS41S 320 or ABB or Phoenix contact or schneider electric. make should be approved by engineer in charge. Total 13344667.28
Item Breakup - B1-SOR execution
180.00 Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008. RATLAM DIVISION-S AND T/WESTERN RLY
180.00 items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
60.00 up to 1 Km including Loading from Starting point, unloading & Stacking at destination.
7200.00 thereof
4800.00 charge arranging /providing of labors for Days various safety related works such as protection of track etc. with contractor's T&P, equipment, hand signal flags, spanners, hammers, etc. as per specification special conditions and detailed scope of work as furnished in the tender and directed by the engineer incharge.
700.00 particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Half Case.
5500.00 route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in- charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
180.00 /Preparation of cable way/Chase 150mm wide at the bottom and 300 mm deep in hard rock (Drg prepared by contactor & approved by Engineer In charge) for laying of S&T cables where minimum required depth not possible & which is verified and agreed by Engineer In charge of the work or his representative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. Refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a separate item in the schedule of work. RATLAM DIVISION-S AND T/WESTERN RLY
direction without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring).
480.00 collars in trenches at places of track and Metre road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.)
450.00 pipes 100 mm Dia (4.5 mm thickness) as Metre per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.
12000.00 pairs/ quads in trenches/ GI pipes/ RCC Metre pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
400.00 route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. Total 10751183.50
Item Breakup - B2-NS execution
Jointing of 4 / 6 quad /Signaling cable Numbers with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost
Laying of half round RCC pipe after Running laying the cables in the trenches. (Cable Metre laying is covered separately)
Blowing of OFC through HDPE duct & Metre protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn or laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting 'Direct in trench' method then this item shall be paid as per accepted rate of this schedule. Blowing/Laying shall be started from one end and each drum laying shall be monitored after blowing/laying and before leaving the site, trace/cable parameters for all the fiber/ conductors shall be taken from one central location by contractor's engineer with his own OTDR , optic talk set/ measuring equipments with railway engineer
Laying of HDPE pipe as per approved Metre cable route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain selead till blowing is done
Splicing of laid under above itemsOFC Numbers cable and making the splicejoint in dust free environment withcontractor's own equipment andlabour. Straight joint enclosure(SJC) is covered under schedule 'A'remaining all required materials,tools, plants shall be arranged bythe contractor. splicing shall bestarted from one end and eachsplicing shall be monitored aftersplicing and after closing theenclosure for all the fibers from onecentral location by contractor'sengineer with his own OTDR andoptic Talk set with railway engineer trace for the fibers shall be takenand signed jointly, if any fibredsplice shows high loss/lossy event,the same shall be redone beforecompletion of splicing work. Thesplice loss shall be as per thepolicy/technical circulars issued bythe railways from time to time RATLAM DIVISION-S AND T/WESTERN RLY
Supply and installation of RCC pre- Numbers fabricated OFC jointing Pits as per DRG. No- RDSO/TCDO/COP-21 (a)/latest. The material shall besupplied as per the instructions ofengineer in charge
Fabrication of EC socket boxassembly Numbers and erection of fabricatedassembly at the location indicatedin the route plan and as perdirection of Engineer incharge. Thisincludes cutting of rails to requiredsize, supply and welding of GI Pipeand base plate, fixing of EC socketbox, transportation of material tosite, digging of pit and erection ofwhole assembly at site. The workalso includes the termination of 6Quad/PIJF cable on the strips of 6-pin EC socket inside box.Rail postwill be supplied by Railway
Painting of emergency socketassembly, Numbers and rail post bysupplying one coat of red- oxide asbase colour and then painting theassembly as per zebra painting inblack and white colours of 100mmwidth
Breaking PFCutting/wall cutting ,Laying of OFC/STP/Power cable/other SnT cables etc in Trenches and through all types of protection VizHDPE/GI/ RCC/DWC/PVC Pipes as the case may be. This includes smooth surfacing to lay cables and stone pavement/Pavers. Minimum size of trench 0.3m widthx 0.60m depth
Supply laying & fixing of Anti Static vinyl Square Flooring with black conductive layer Foot sandwiched between two antistatic layer thickness of 2mm ± 01mm self fire extinguishing as approve by engineer incharge
Installation & wireless router RATLAM DIVISION-S AND T/WESTERN RLY
Supply and Installation of MULTIPLE Pair MEDIA AUTO CHANGEOVER CONVERTER- 4 PORT, for simultaneously interconnecting Digital Axle Converter, UFSBI, Block Phone etc. across a Block Section/ IBs over multiple media. Product has the following features: a)Two 120 ohm E1 Main Links with RJ45 connector, having (1+1) hot standby facility b)Two optical Main Links with (1+1 hot standby dual core path and single core path) having 20 Km driving distance. c)Four V.21N.23 (E&M) 2-wire/4-wire user interface with auto changeover to Quad links in case of failure of all Main Links. Each user port is configurable as 2W or 4W without any restriction. d)Unit supports power OFF fail safe mechanism. In case the unit is switched OFF, all analog user devices are bypassed to the Quad link automatically. - e)Unit supports four numbers of Potential free contacts which can be linked with data logger/RTU for E1 Status, Optical status & Power Supply status. ' f)Unit supports front panel resettable audible buzzer in case of main link fails (optical or E1). g)Unit suppqrts front panel LED indicators for Quad health status, E1 dual, Optical dual path. h)Uriit %B7 has dual hot standby DC power supply having 24VDC/48VDC i)"Unit is 1U height with 19 inch rack mountable-facility j)Unit supports operating temperature from -5 degree Celsius to +55 degree Celsius. Accepted Make/Brand:-CYGNUS or Team-Link or Webfil, Compatible with the existing system.
Supply and Installation of E1 Surge Numbers Protector as per Specification
NOC Room Interior & Furniture as per Square Technical Specification attached Foot RATLAM DIVISION-S AND T/WESTERN RLY
Design , Fabrication & Supply of rack Set mountable modular intelligent service IP MPLS aggregator router with minimum switching speed of200 Gbps, unit to supportL2VPN ,L3 VPN, MPLS-TE , unit to be capable to support 8x10G(optical) ports distributed in two cards and possible to upgrade16x10G (optical), this should also support multiple routing functions such as OSPF, ISIS,BGP & MP- BGP and support LDP and RSVP - TE to dynamically establish MPLS tunnels & PW service. It should support dual main control card redundancy design supporting 1:1 hot backup. The router should have console and SNMP interface, FAN Module , Redundant control card modules and Redundant48V DC power supply modules including connection cable and fixing accessories etc. The Router should have required interface slots to accommodate8x10Gbe interface, capable to upgrade to 16 x 10Gbpsmodules from day one(supply of these interface cards is not covered in this item). Unit to be capable to support 25G / 100Gmodule for aggregation purpose. The router should support all the software features, environmental standards and security features as mentioned in RDSO technical document no. STT/TAN/IP-MPLS/2020 Ver2.0 or latest for the LSR Router (Router should be compatible to existing router installed in division) {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}.
Supply and installation of 2MP Full HD Numbers night vision Dome camera (including necessary enclosures, clamps, housing, fixing arrangements to fix cameras on ceiling, PF shelters, poles, gates and with 3 year OEM warranty ) (Make: should be complied MAKE IN INDIA policy)
Supply commissioning of 43"(minimum) Smart LED display of confirming as per technical specification With HDMI port. Installation as per engineer in charge. (with 3-year OEM warranty) Make: SONY, SAMSUNG, LG.
Supply and installation of 2MP Full HD Numbers night vision bullet camera (including necessary enclosures, clamps, housing, fixing arrangements to fix cameras on ceiling, PF shelters, poles, gates and with 3 year OEM warranty ) (Make: should be complied MAKE IN INDIA policy)
Supply & installation of 32 channel NVR Numbers number of video input channels-32,No. of video output channels-32,recording resolution-4K(3840X2160), supporting compression techniques-H.264, H.265, MPEG-4, MPEG,H.265,H.264+,minimum cameras views on single display-16. (Make: should be complied MAKE IN INDIA policy) RATLAM DIVISION-S AND T/WESTERN RLY
Supply and testing of 4TB Surveillance Numbers Hard Disc Drive of 4TB capacity with 64MB Cache & SATA 6GB/S interface for DVR/NVR. Make:- Seagate, Western Digital,Hitachi,Sony or reputed make
Removal of paver blocks/tilesand cutting Metre of trench acrosson platform for a depth of 15cm & width of 15 cm withmarble cutting machine &filling the trench after layingthe cables & restoring thesurface with original tiles with smooth finish as per instructions of site in-charge at site. All the materials except pipe are to be arranged by the contractor at site, the debris is to be cleared from platform to outside the station premises
Installation, Testing & Commissioning of Numbers 24 Port LIU with suitable Connector as per the instructions of Engineer in Charge
Supply Installation & Commissioning of Numbers Layer 2 Manageable, 24 Port POE, 24 GE10/100/1000 Base X Ethernet port with POE+support and 4x1GE SFP Port for uplink with 4 no of 1GEBX SM SFP modules fully loaded, with all accessories per RDSO/SPN/TC/65/2021,Rev.6.0 with Amd 1,2 & 3 or latest
Wiring, drawing, fixing, laying and Metre clipping of all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer
Supply & installation of GRP/FRPcable Metre tray & required accessories asper specification
Supply, Commissioning of Professional Large Format LED Video Display Unit, 55" (inches) or larger, Full HD 1920 x 1080,Brightness: 350cd/m, contrast ratio1100:1, HDMI & DVI port, Including wall mount kit. as per clause no. 9.0 of RDSO/SPN/TC/65/2021 Rev. 6.0 or latest. Make: SONY, SAMSUNG, LG, TCL
Supply and fixing of GI channel of size Numbers 100 mm x 50 mm x 06mm, 1.2 Mtr. Long (fixing of channel with Girder to be done with hook/ 'J'bolts of suitable size to held the load of the troughing/Pipe on girder /other type bridges in yards and mid sections for carrying telecom cables
Splicing of fibres OFC Cable and making Numbers Splice joint with contractor's own splicing machine and tools and consumables. (Rates are for single fiber splice)
Excavation of the cable trench in hard Metre soil and/or Murrum soil mixed with boulders 300 mm wide at the bottom and 1.2 mtr deep or for less depth refilling the same with 1:3:6 CC of 200 mm thickness RATLAM DIVISION-S AND T/WESTERN RLY
Installation of IP MPLS Routerand Set switches, with powerdistribution panel and allaccessories in the 19"Rack ,DDF, Aluminum runway ladder,patch cord etc and their testingand commissioning. Thisincludes termination of all E1'son DDF, connection of pigtails,optical patch cords and 48 V busto the IPMPLS equipmentincluding supply of wires andconnectors. It also includes proper mounting of rack,provision of Aluminum runwayladder, casing and capping andconduit pipe as per requirementat each station, other materialsfrom stores supplied byRailways for installation. (Conduit pipe/ casing andcapping, aluminum runwayladder and all othermiscellaneous materials shouldbe supplied by the contractor)
Supply of straight joint enclosure Numbers [SJC]complete with all accessories of 48 Fiber OFC and splicing of 2 X48 Fiber OFC in joint as per RDSO/SPN/TC/68/2025, Rev. 2.0 or latest Total 13186847.93
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .