Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAccepted-AOC | ₹6.3 Cr Quoted ₹6.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹6.6 Cr+₹6.0 L (0.92%)Rejected-AOC | ₹6.6 Cr+₹6.0 L (0.92%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹6.6 Cr+₹12.1 L (1.86%)Rejected-AOC 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹6.6 Cr+₹12.1 L (1.86%) | L3 | Rejected-AOC Rejected |
Tender Value
₹6.2 Cr
EMD Value
₹3.2 L
Closing Date
4 Mar 2024, 3:00 pmClosed
Chief Engineer
Office of Chief Engineer, Sardar Patel Road, Dote Campus, Chennai 25
Construction of Additional 12 Class room and 4 Laboratories building in Kalaignar Karunanidhi Government Arts College at Thiruvannamalai in Thiruvannamalai District.(2nd call)
2024_HE_426015_1
Kalaingar_2023
Open Tender
Civil Works
Lump-sum
365 days
Thiruvannamalai
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹3.2 L
Yes
16 Jul 2024
16 Feb 2024
5 Mar 2024
16 Feb 2024
4 Mar 2024
16 Feb 2024
Amount
Earthwork excavation for foundation in all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary, refilling the foundation with excavated earth and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of 2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
Earthwork Open excavation in all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary refilling the foundation with excavated earth other than sandy soil in layers of not more than 15 cm thick layers well rammed and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of 2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Filling in foundation and basement with filling m sand in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Cement concrete 1:5:10 (one cement, five M sand and ten aggregate) using 40mm gauge hard broken blue granite stone jelly for foundation and basement including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification and as directed by the departmental officers.
Refilling basement with excavated earth other than sand with an initial head lead of 100 mts. and depositing the earth as shonw by the departmental officers in layers of not more than 15cm thick well rammed, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers..
Supplying and filling in foundation and basement with Gravel in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Providing additional strutting using casurina poles to centering of RCC slabs or plane surfaces for every addtional 1 metre height or part there of but not less than 30cm over the initial height of 3m from floor level using casurina props of 10cm to 13cm dia including cross bracings etc., complete complying with standard specification and as directed by the departmental officer.
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance using with IS:456-2000, 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of m sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For foundation and basement
In Superstructure in Ground floor
In Superstructure in first floor
In Superstructure in second floor
In Superstructure in third floor
Supplying, fabricating and placing inposition of steel reinforcement using MS/Ribbed tor steel rods for all RCC works as per the design given including cost of steel and G.I binding wire also in all floors etc., complete complying with standard specification and as directed by the departmental officers.. ( The contractor will have to make his own arrangement for the supply of M.S plain rod/ RTS rod and black binding wire )
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) For column footing plinth beam etc.
Supplying and erecting steel centering including necessary supports for plain surfaces, for all RCC works including strutting upto 3.29m in all floors using mild steel shutters of size 90cmx60cm of BG 10 stiffened with mild steel angles of size 25mmx 25mmx3mm laid over silver oak (Country wood) Joists of size 10cmx6.5cm spaced at about 90cm c/c and supported by casurina props of 10cm to 13cm dia. (spaced at 75cm c/c) etc., complete complying with standard specification and as directed by the departmental officers. (The centering will be removed after specified period of concrete without damaging the concrete)
For plane surface such as RCC floor slab, roof slab, beam litels bed blocks, landing slab, waist slabs and beams, etc.,
For plane surfaces such as RCC square or rectangular column, top and bottom slab of sunshade, boxing sill etc. complete as directed
For plane surface such as Vertical surfaces such as sunshade, boxing vertical drops, facia for sunshade and other vertical walls etc.,
Brick work in cement mortar 1:6 (one cement and five M sand) using Fly Ash bricks of size 230×110×70mm including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For foundation and basement
For superstructure in ground floor
For superstructure in first floor
For superstructure in second floor
For superstructure in Third floor
Brick work in cement mortar 1:5 (one cement and five M sand) using Fly Ash bricks of size 230×110×70mm including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For foundation and basement
For superstructure in ground floor
Brick partion wall 11.10cm thick in cement mortar 1:3 (one cement and three M sand) using Fly Ash bricks of size 230×110×70mm including fixing hoop iron reinforcement if found necessary, laying, finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
For superstructure in ground floor
For superstructure in first floor
For superstructure in second floor
Providing Anti – termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work). Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth. Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout. Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment.
Special ceiling plastering and finishing all reinforced cement concrete exposed surface such as reinforced cement concrete slab, sunshades, staircase steps landing slab with cement mortar 1:3 (One cement and three p sand) 10mm thick including hacking the surface and providing necessary cement mortar nosing beadings wherever necessary using the same mortar as directed by the Departmental Officers complete complying with standard specification.
Plastering with cement mortar 1:5 (one cement and five p-sand) 12mm thick in all floors using fine river sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Plastering with cement mortar 1:3 (one cement and three p sand) 12mm thick with WPC 2% by weight of cement used in all floors using fine river sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Providing mixing laying polymer based water proofing treatment for the sunkan toilet by applying cement based fiexable WPC conforming to IS 2645 to a thickness of 1mm of the prepared surface of the roof slab / floor slab as per specification mendioned above providing cm 1:3 water proofing cover plaster to a thickness 12mm. The malaime coating with admixture of approved make rate quoted is inclusive of preparation of surface which including cleaning of surface polymer morter, curing, labour, tools equipments etc., rate inclusive of cement and sand required for the treatment the coat and labour charges for fixing 25mm dia pressure pipe 15 kg / m2 to length of 45 cm for drip pipe etc., complete complying with standard specification and as directed by the departmental officers..
Brick Jelly Lime Concrete of 1:2:5 (One Lime,Two m Sand and Five Brick jelly ) with 40 mm hand broken brick jelly for Sunken portions including dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
Finishing the top roof with one course of solar reflecting ceramic tiles of size 305x305x7mm thick of approved quality set in cement mortar 1:3 (One cement and three sand) (12mm thick ) and mixed with for 10M2 / 4.00 kg Epoxy Packing conforming to ISS including curing etc., complete complying with standard specification and as directed by the Departmental officers.
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 Cft. by volume and laid over the RCC roof slab in a single layer and consolidated to the required design and finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers.
For superstructure in first floor
Finishing the top of roof with one course of Machine pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three M-sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide and water proofing compound etc., complete complying with standard specification and as directed by the departmental officers.
Plain Cement concrete 1:2:4 (One cement two m-sand and four aggregate) using machine crushed 20mm gauge hard broken granite stone jelly excluding cenetering, shuttering and, but including laying, curing and finishing etc., complete complying with standard specification and as directed by the departmental officers.
For superstructure in second floor
Supplying and fixing in position best approved of ISI quality of following dia PVC rain water down fall pipes having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification and as directed by the departmental officers..
160mm dia of PVC rain water down fall pipes (for three floors)
110mm dia of PVC rain water down fall pipes (for three floor)
160mm dia of PVC rain water down fall pipes (for two floors)
110mm dia of PVC rain water down fall pipes (for one floor)
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the departmental officers..
Painting the walls two coats with best Oil bound distemper of approved quality (to be approved by the Executive Engineer before use on works) over one coat of primer for newly plastered wall including preparation of surface and finishing neatly including cost of all materials, brushes, scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers.
Painting the exterior walls surface two coats of best and approved first quality and colour of Exterior emulsion paint in all floors over one coat of primer including preparation of surface, wall putty two coats with good quality including cost of wall putty , emmary sheet, plates, etc. and including labour charges for rubbing the wall scrapping putty pasting works and making good smooth surface and finishing neatly etc., . complying with standard specification and as directed by the departmental officers etc. complete. ( The make, quality and colour of paint should be got approved by the departmental officer before use of work)
Supplying and painting the walls with two coats of cement paint over one coat of cement primer as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).
Supplying and painting the walls with two coats of cement paint as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).
Paving the floor with Stain free nano polished vitrified tiles (like Marbonite or equivalent) of approved quality and colour of size 600 x 600x 8 mm thickness in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the Departmental officers. (The tiles should be got approved by the Departmental officers before use on works).
Paving the floor with Tactile paver type of new tack BT yellow colour ceramic tiles of approved quality and colour of size 305 x 305 x 15mm in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works).
Paving the floor with colour design ceramic tiles of approved quality and colour of size 305 x 305 x 6mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works).
Paving the floor with pre polished concrete Hydraulically pressed Anti skid tiles (like Eurocon Tiles) 20mm thick in all floors set in cement mortar 1:3 (One cement and three sand), 20mm thick and pointing with the cement including adding suitable colouring pigments of match with colour of tiles and finishing and curing as directed by the departmental officers including cost of tiles, and all other materials, transportation charges and labour charges for laying of tiles as directed by the departmental officers complete complying with standard specification. (The tiles should be got approved by the departmental officers before use on work.)
Paving the floor with pre polished concrete Anti skid step tiles (like Eurocon Tiles) 20mm thick in all floors set in cement mortar 1:3 (One cement and three sand), 20mm thick and pointing with the cement including adding suitable colouring pigments of match with colour of tiles and finishing and curing as directed by the departmental officers including cost of tiles, and all other materials, transportation charges and labour charges for laying of tiles as directed by the departmental officers complete complying with standard specification. (The tiles should be got approved by the departmental officers before use on work.)
Dadooing the walls with colour design glazed tiles of size 300mmx 450mmx 8mm of approved quality in all floors set in cement mortar 1:2 mix (one cement & two M-sand) 10mm thick and pointing with white cement using 0.4 kg/m2 including adding suitablee colour pigments to suit the colour of tiles including finishing the joints neatly and curing etc.,complete complying with standard specifications. (The tiles should be got approved by departmental officers before use on the work).
Fabricating supplying and fixing in position CRCA pressed steel box section 18 gauge or 1.25mm thick for door frames of section size 105mmx60mmx1.25mm thick with necessary rebate of size 35x15mm for housing door shutters conforming to IS specification. Frames shall be fabricated to the specified door size with joints properly welded and grinded. Stiffeners with 25x3mm MS flat shall be provided around the frame at 60cm intervals. The cost shall also include for providing 3 Nos. of MS clamps with 25x3 flats each on either sides of door frame, providing bottom tie, with 10mm dia MS rod, providing necessary holes for receiving tower bolts 2 Nos. with stiffeners on inner side, providing the required number of I.O hinges of size 125x30mm for shutters properly welded to the frames, finishing the door with one coat of good quality red oxide primer with cement concrete 1:2:4 (One cement, two sand and four aggregate) using 20mm gauge hard broken granite stone jelly packed inside to the frame including cost of all materials, fabrication and conveyance to the site and fixing in position with necessary scaffolding etc., complete complying with standard specification and as directed by the departmental officer.
Supplying and fixing in postion of 35mm thick solid core flush door shutters Double Leaves with following specification. with Commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in postion of 35mm thick solid core flush door shutters single leaf with following specification. with Commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, complete complying with standard specification and as directed by the departmental officers.
Supply and Fixing of M.S. steel doors with Single Leaves following specification. MS angles of size 40x40x 6mm at 3.5 kg/m used for the outer frame and MS angles of size 35x35x5mm at 2.60 kg/m for the shutter frames. Stiffners with 32x6mm at 1.50 Kg/m. MS flat is provided as the lock rail of the door and welded infact of both ends to the shutter frame, 18 gauge CR sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50 Kg / RM and MS flat on the rear side of the door sandwitching the CR sheet for rigidity with locking rail and bottom tie arrangements. Additional stiffners with 18x5 mm at 0.7 kg/m MS flats are provided horizontally diagonally on the rear side of the shutter. 2Nos of hinges in case of single leaf and 4Nos of hinges in case double leaf shutter is provided 6 Nos of hold fasts 200 length 40x40x6mm M.S. angle spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. one at top and the other at bottom are provided. One aldrop is provided incase of double leaves door at lock rail section in the door. For single leaf doors, one more aldrop is provided in the inner side at the lock rail section of the door.
One rotating locking arrangements at the inner side of the door and additional provision for locking arrangements for lock is provided with 32x6mm MS flat on the rear side of the door at an appropriate place incase of a double leaves door MS flat 32x6mm at 1.50 kg/m is provided on the edge of one shutter to conceal the gap between the shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given a shop coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials labour charges transportation taxes and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers..
Supplying and fixing 30mm thick solid core PVC door shutter with PVC frame of size 50x45mm with suitable rebate for housing the shutter consisting of frame made out of MS tubes 19 gauge thickness and size of 19x19mm for styles and 15x15mm for top and bottom rails, MS frame shall be covered ith 5mm thick heat moulded PVC 'C' channel of size 30x50mm forming styles and 75x50mm for top rai8l, lock rail and bottom rail on either side and 10mm thick 20mm wide cross PVC sheet as gap insert for tap rail, botytom rail, panelling of 5mm thick PVC sheet bearing on either side and join together other side etc. An additional 5mm thick PVC strip of 20mm width is to be stack and the interior side of the 'C' channel using PVC sealant adhesiv e including cost of all furniture fittings, such as aluminium aldrop of size 250x16mm -1 No. aluminium tower bolt 250x12mm-1 No. aluminium D type handled 200mm etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position of solid panel PVC door with sliding aluminium frame. The outer frame will be 62x38x2mm @ 1.17 kg/m and 40x20x2mm Aluminium "C" section. Soild PVC door shutter using 16 Gauge 19mm MS Sq. tubes for styles and outer frames. 15mm Ms. Sq. Tubes for top Lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture fittings. The overall size of styles shall be 50mmx30mm. The overall size of top rail, lock rail and bottom rail shall be 75mmx30mm, with suitable rebate for housing the shutter etc., complete complying with standard specification and as directed by the departmental officer.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
Manufacturing, Supplying and fixing Stainless Steel hand rail for staircase using 50mm dia 304L Grade stainless steel pipe of 1.60mm thick at at required locations to a height of 1000mm from finished floor level welded to 38.30 mm dia stainless steel pipe post of 1.00mm thick as vertical at 900 center with 3nos of 25.40mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100x100x6mm MS base plate encased in the base concrete. The rate is inclusive of charges for cutting , bending , welding , grinding polishing conveyance, electrical charges , etc., complete complying with standard specification and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for toilets of Differentially abled person using 50.80mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete complying with standard specification and as directed by the departmental officers.
Painting the new wood work two coats with best approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work).
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. (The quality and colour of paint should be got approved by the departmental officer before use on work).
Supplying and fixing of special type Terra Cotta Jally of size 20x20x5cm of approved pattern including pointing neat finishing and labour charges for fixing the jally in position etc., complete complying with standard specification and as directed by the departmental officer.
Supplying and installation of Ceramic Steel chalk writing board with the following specification. The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners. The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers.
Providing expansion joint of 20mm width in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non - absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed by the departmental officers..
Providing expansion joint of RCC floor slab for 20mm width using polysulphide as sealent on top and bottom for a depth of 7.5mm each and packing the inner space using compressible non - absorbent, filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers..
Providing expansion joint of 20mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non - absorbent, flexible and well compressible filler materials of approved quality and covering top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers..
Supplying, laying and jointing PVC soil / waste pipes of approved and best variety conforming to IS. Specification with ISI. mark of the following sizes including, cutting and threading of PVC Pipes, fixing specials but excluding cost of such specials but including fixing to wall with necessary teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in roof and making good the dismantled portion to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. The PVC Pipes should be got approved by the Departmental Officers before use on work. Below ground level.
160mm dia PVC soil pipe
110mm dia PVC soil pipe
75mm dia PVC soil pipe
Supplying and fixing PVC Ventilating shaft of 110mm dia (having working pressure 4 kg / sq.cm) and 3 m height including cost of cylindrical cowl of best approved quality etc., complete complying with standard specification and as directed by the departmental officers. The PVC ventilating shaft should be got approved by the departmental officers before use on work.
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm dia PVC door Elbow
110mm dia PVC door Tee (Single)
110mm dia PVC door (Single) "Y"
75mm dia PVC door Elbow
75mm dia PVC door Tee (Single)
75mm dia PVC door (Single) "Y"
110mm dia PVC Cowl
75mm dia PVC Cowl
75mm dia PVC Plain Tee
75mm dia PVC Plain Elbow
75mm dia PVC Bend
Supplying, fabricating, erecting and fixing new GYP BOARD FALSE CEILING using 10mm thick plain sheets of approved quality and design suspended from ceiling using 'U' shaped GI channels of size 25mmx0.55mm thick at 1.2m c/c on both longitudinal and cross direction for vertical supports and fixing 'U' shaped GI channels of size 50mmx30mmx0.55mm thick at 0.90m c/c in cross direction and longitudinal direction respectively for horizontal support by using teak wood reapers at corners and intermediately fixing plaster of paris on the panel provided as per design/pattern given by the site Officer and finishing the ceiling surface with same plaster of Paris materials etc., necessary opening should be made for providing spot light florecent tubes in the ceiling complying with standard specification two coat of distempering and as directed by the Departmental officers.
Supplying and fixing Gyp-board designed Cornices of 100mm width in the edges of the false ceiling wherever necessary as per the direction of the filed officers. The rate includes the cost of materials, transportation charges and fixing charges and other incidental charges etc., the pattern of the cornice has to be approved by the Executive Engineer before used on work etc., complete complying with standard specification and as directed by the departmental officers.
Providing cupboard shutter using termite/water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc. as directed by the departmental officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer before use on work.
Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with 'P" trap or 'S' trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet and all accessories should be got approved by the departmental officers before use on work)
Supplying and fixing in position White Glazed European water closet of best quality and approved make with 100mm P or S trap with double flapped rigid PVC.seat cover with chromium plate brass hinges, including supplying and fixing PVC. Low level flushing tank 10 litre capacity of approved quality on wall with teak wood plugs, brass screws and 2 numbers 15mm dia gun metal wheel valve, 15mm dia nylon connection and giving necessary water supply connection as directed by the departmental officers. The rate includes cost of 100mm dia PVC.Pipe 60cm long including cost of 3 Kg.of white cement 6Kg.of cement, spunyarn, shellac, thread ball, teak wood plugs, brass screws 75mmx10mm etc., complete complying with standard specification and as directed by the departmental officers. (The European Water Closet and flushing tank should be got approved by the Departmental Officers before use on work.)
Supplying and fixing in position best quality of approved make white glazed earthernware wash hand basin (without pedestal) of size 550x400mm with a pair of cast iron brackets , including cost of 15mm diametre brass chromium plated pillar tap, 32mm diametre C.P.waste, 32mm diametre PVC waste pipe with rubber plug and chain, 15mm diametre gun metal wheel valve, 15mm dia brass nipple, 15mm dia nylon connection etc. including fixing the wash hand basin in the wall in position with pair of C.I.brackets with teak wood plugs and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anti-corrosive paint including testing for leakage etc., complete complying with standard specification and as directed by the departmental officers.(The wash hand basin and specials should be got approved by the departmental officers before use on work)
Supplying and fixing in position 15mm dia Chromium Plated brass screw down tap (heavy type) of approved make conforming to ISS.and including cost of shellac, thread complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Departmental Officers before use on the work)
Supplying and fixing Stainless steel health faucet of best quality with control valve etc., complete complying with standard specification and as directed by the departmental officers (The materials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position PVC Nahini trap of size 100x75mm with best pvc gratings of approved brand and quality with fixed over a bed of brick jelly lime concrete 1:2:5(one part of lime,two parts of sand and five parts of 40mm size brick jelly)and finished with cement Mortar 1:3(one cement and three sand)including dismantling masonry works wherever found necessary and making good the damaged portions to the original condition giving connections to the pipe etc., complete complying with standard specification and as directed by the departmental officers. (The PVC Nahini trap with grating should be got approved by the departmental officer before use on works).
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. For External Water supply arrangements. (Above Ground Level)
20mm dia UPVC pipe
25mm dia UPVC pipe
32mm dia UPVC pipe
40mm dia UPVC pipe
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. For External Water supply arrangements. (Below Ground Level)
50mm dia UPVC pipe
Supplying and fixing in position of the following UPVC specials best approved quality conforming to ISS and providing leak proof joints with UPVC adhesive etc., including fixing to walls with necessary teak wood plugs screws etc., and giving connections to the UPVC pipe dismantling the brick masonry RCC floor or roof slab and redoing the disturbed portion to original conditions etc., complete complying with standard specifications. -The UPVC specials should be got approved from the Executive Engineer before use on works -.
20mm dia UPVC Coupler
25mm dia UPVC Coupler
32mm dia UPVC Coupler
40mm dia UPVC Coupler
50mm dia UPVC Coupler
20mm dia UPVC Elbow
25mm dia UPVC Elbow
32mm dia UPVC Elbow
40mm dia UPVC Elbow
50mm dia UPVC Elbow
32mm dia UPVC Bend
40mm dia UPVC Bend
50mm dia UPVC Bend
20mm dia UPVC Tee
25mm dia UPVC Tee
32mm dia UPVC Tee
40mm dia UPVC Tee
50mm dia UPVC Tee
20 x 15 mm dia UPVC Reducer
25 x 20 mm dia UPVC Reducer Tee
32 x 25 mm dia UPVC Reducer Tee
50 x 40 mm dia UPVC Reducer Tee
20 x 15 mm dia UPVC Reducer Elbow
32 x 25 mm dia UPVC Reducer Elbow
50mm dia UPVC Union
40mm dia UPVC Union
32mm dia UPVC Union
25mm dia UPVC Union
Supplying and fixing in position first quality and approved variety of Gun metal Gate/Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25 mm dia G.M Wheel valve
32 mm dia G.M Wheel valve
25 mm dia G.M gate valve
40 mm dia G.M Gate valve
50 mm dia G.M Gate valve
Supplying and Fixing RCC precast slab in reinforced cement concerete 1:2:4 (One of cement, two of sand and four of aggregate) using 20mm hard broken stone jelly and river sand, excluding the cost of reinforcement grills and including fabrication charges, moulding, curing, finishing charges and fixing in position neatly etc., complete complying with standard specification and as directed by the departmental officers.
50mm thick
Paving the floor with best approved quality fine polished Jet Black Granite Slabs of size 1200 x 600 of 16 / 18mm thick and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Labour charges for finishing the top of working tables and staircase step portion with nosing arrangements in Granite slab tiles including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers.
Supplying and Fixing of white Porcelain sink of size 600mm X 450mm X 200mm including cost of 32mm dia 'B' class GI waste water pipe with rubber, plug and chain and 32mm dia CP waste coupling, 15mm dia brass nipple including fixing the sink in position and testing for leakage etc., complete complying with standard specification and as directed by the departmental officers. (The sink and specials should be got approved by the Executive Engineer before use on works). (For fixing the sink on masonry support walls to be measured and paid in main item.)
Supplying and erecting 5.00 H.P. monoblock pump set with panel board of approved make conforming to ISI.including cost of all accessories, transportation charges, labourcharges for erecting and fixing the motor in position testing as directed by the Departmental Officers complete complying with standard specification. The quality and standard of product should be got approved by the Departmental Officers before erecting. Necessary warranty card should be produced before erection of Motor.
Supplying and fixing of 2.50 sq.mm PVC insulated and sheated 2 core armoured aluminium cable confirming to IS 694/1990 etc., complete complying with standard specifications and as directed by the departmental officers..
Finishing the top of flooring with granolithic floor finish of following thickness with plain cement concrete of mix 1:2:4 (One cement, two M sand and four aggregate) using 20mm / 10 to 12mm ISS gauge hard broken granite stone including finishing the top smooth and forming thread lining and curing etc., complete complying with standard specification and as directed by the Departmental officers
25mm thick
40mm thick
Supplying and laying of 83 mm thick high strength type of interlocking rubber moulded hydraulic pressed paver block of approved colour made up of designed concrete mix 1:1:2 using 10 to 12mm size HBG stone jelly in required shapes and sizes having minimum compressive strength of 40 N/mm2 to be laid in flurrying bone pattern with approved non sticking surface at top. The rate is inclusive of levelling the site, compacting with power compactor and sweeping the sand grouting and also inclusive of transportation charges, loading, unloading and labour charges for laying the paver block, etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of 40mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc. complete complying with standard specification.
Supplying and filling of 20mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc. complete complying with standard specification.
Supplying and fixing of Incinerator for Ladies Toilet etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Fixing of PVC ready made water tank of approved quality with standard specification and best brand including testing for leakages after making installations and connections. The cost inclusive of lid and lock with bolt and nuts for PVC tank, transportation, loading, unloading, lifting, installation and necessary connections etc., complete complying with standard specifications and as directed by the departmental officers.(The PVC Water Tank should be got approved by the Executive Engineer before use on works).
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) powder type fire extinguisher of 6 kg capacity as per IS:15683with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc. including conveyance, all incidential charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the Departmental Officers. Make: Excellent/Safety First/equivalent.
Supply and fixing of carbon-di-oxide gas type 2 kg. capacity Fire extinguisher as per new IS:15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc. including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the Departmental Officers. Make: Excellent/Safety First/equivalent.
Construction of INSPECTION CHAMBER 600 x 600 x 600 mm clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five M sand] using best quality of Fly Ash bricks of size 230×110×70mm " with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Supplying and Fixing of white Stainless Steel sink of size 1200mm X 550mm X 180mm including cost of 32mm dia 'B' class GI waste water pipe with rubber, plug and chain and 32mm dia CP waste coupling, 15mm dia brass nipple including fixing the sink in position and testing for leakage etc., complete complying with standard specification and as directed by the departmental officers. (The sink and specials should be got approved by the Executive Engineer before use on works). (For fixing the sink on masonry support walls to be measured and paid in main item.)
Supplying and fixing new one of best approved quality Chromium plated Soap Tray of size 150x100mm of approved quality and brand including cost of rawel plug, brass screws etc.,complete complying with standard specification and as directed by the departmental officers. (The materials should be got approved by the Executive Engineer before use on works).
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand of size 600x450mm x5.5mm thick with necessary plastic back, PVC frame with bottom stand of approved colour with brass screws, rawal plugs etc. complete complying with standard specification and as directed by the departmental officers. (The materials should be got approved by the departmental officers before use on works)
Supplying and fixing of Reverse Osmosis Plant of capacity 250 litres per hour. The Reverse Osmosis plant is stainless steel skid mounted with the parts. Raw water from the water tank is fed in to Pressure sand filter by raw water feed pump. The Pressure sand filter consists of FRP Vessel, Multiport valve and filtration media of pebbles & sand. Raw water enters in to the top of vessel and percolate through filter media and the suspended particles traps in the filter media top. Filtered water flows through Activated carbon filter for removal of colour and organic particles present in the water.The water passes through 10, 5 Micron filter to ensure the fine filtration of feed water. Micron filter made of Polypropylene material and its housing also made of PP. This fine prefiltered water pumped in to RO membrane in the pressure of 10-12 kg/cm2 through high pressure pump.The RO membrane made of thin film composite polyamide and it pore size 0.0001 microns (pore size lesser than Bacteria and virus). After penetrating through this membrane the purified water is collected in the center of the membrane and the salt, bacteria are rejected from the membrane side way. This purified water is collected in to water storage tank for further distributions. The reject water from the RO plant will have a higher TDS and the water is suitable for external applications like sanitary applications, flushing lines, gardening, etc., and as directed by the departmental officers. The rate includes cost of plant, cost of storage tank, loading and unloading, transportation charges, electrification charges, all taxes and all other incidental charges etc., complete.
Supplying and fixing of bare Galvalume sheet (aluminium zinc alloy coated sheet) with yield strength 550Mpa and 0.47mm thickness incluidng all fittings as directed by the departmental officers. The rate is including cost of materials, labour charges for fixing conveyance, loading and unloading and all taxes etc., complete complying with standard specification. (The Bare Galvalume sheet ould be got approved by the Executive Engineer before use on work).
Supplying and fabricating and fixing in position 50mm dia GI pipe 'B' class for holding the AC sheet roof including cutting the pipe to the required length and shape grinding the edge smooth welding wherever necessary as directed by the departmental officers including cost of one coat red oxide primer etc., complete complying with standard specifications and as directed by the departmental officers . The rate includes cost of GI pipe, taxes and labour charges for fixing in position.
Supplying and fixing in position of Indian make white glazed earthen ware lipped mouth flat back Urinal of best approved quality with 32mm dia bell mouthed PVC connection,15mm dia G.M wheel valve,fixing the Urinal to the wall in position with necessary T.W. plugs,clamps,screws shellac etc.,including dismantling masonry if necessary and redoing the same to original condition,fixing the 15mm GI pipe connection and wheel valve, painting the pipe with two coats and checked without any leakage etc., complete complying with standard specification and as directed by the departmental officers.(The urinal should be got approved by the departmental officers before use on work).
Supplying and fixing in position of polished white marble slab (Adanga) of 20mm thick for urinal partition of size 1.20x0.60m including and fixing the marble slab with C.M.1:3 etc. complete complying with standard specification and as directed by the departmental officers.
Sub Total
N. Devaprabhu
ABIRAMI ENGINEERING CONSTRUCTION AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .