Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Accepted as techno commercially eligible L1 bidder |
| 2 | L2₹1.4 Cr+₹13.9 L (10.8%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹1.4 Cr+₹13.9 L (10.8%) | L2 | Rejected-Finance Rejected as L2 bidder |
| 3 | L3₹1.5 Cr+₹22.8 L (17.8%)Rejected-Finance | ₹1.5 Cr+₹22.8 L (17.8%) | L3 | Rejected-Finance Rejected as L3 bidder |
| 4 | L4₹1.5 Cr+₹25.3 L (19.7%)Rejected-Finance AT RANGIAMUNDA PO TANGARPALI DIST SUNDARGARH ODISHA | KENDRAPARA | ODISHA | 754217 | ₹1.5 Cr+₹25.3 L (19.7%) | L4 | Rejected-Finance Rejected as L4 bidder |
Tender Value
₹1.5 Cr
EMD Value
₹1.8 L
Closing Date
17 Jul 2023, 5:00 pmClosed
GM CSR Civil-Welfare n TA
Office of GM CSR Civil-Welf n TA
Electrical Power supply arrangement to the sports complex of Jagruti Vihar, MCL HQ
2023_MCL_282058_1
MCL/SAMB/TA/ENM/2023-24/01 DATED 26/06/2023
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
MCL HQ
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.8 L
2 Dec 2023
26 Jun 2023
19 Jul 2023
26 Jun 2023
17 Jul 2023
26 Jun 2023
26 Jun 2023 - 4 Jul 2023
Amount
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply and laying of 3.5 core 400 sq.mm size multi stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 400 sq. mm (82mm)
Supply and laying of 3.5 core 300 sq.mm size multi stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Supply and laying of 4 core 25 sq.mm size multi stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
Supply and comissioning and testing of On load 100A Change Over Switch ( 2 ON Position & 1 NEUTRAL Position) of L&T/ABB/Schneider or of equivalent reputed make
Supply and laying of 4 core 16 sq.mm size, multi-stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supply and Laying of 3 core 35 sq mm size, multi stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required suitable for 25/70 sq.mm size
Supply and laying of 300mm internal Dia Hume Pipe as per requirement
Supply and laying of 900mm internal Dia Hume Pipe as per requirement
Supply and Laying of 6 inch/150mm dia PVC Heavy duty pipe as per requirement
Supply and fixing of 6 inch/150mm GI clamp along with suitable nuts and bolts as per requirement
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply and fixing of earthing coil in the existing pit
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and fixing 16 amps rating, SPN, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 10 amps rating, SP, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 amps rating, SPN, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 amps rating, SP, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required with MCB of Havells/L&T/ABB/Schneider or of equivalent reputed make
Supplying and fixing of 63Amps, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 40 Amps, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of 2+10 way, SPN,single door,MCB DB
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply and fixing of 20W LED, Downlight of minimum 50,000 burning hours of Crompton/Syska/Orient or equivalent reputed make along with suitable wiring for connections
Supply of 400mm sweep 3 blade pedestal fan of Compton/Orient/havells or equivalent reputed make
Supply of 400mm sweep 3 blade wall mounted fan of Compton/Orient/havells or equivalent reputed make with necessary boting arrangement to wall
Supply and fixing of LED strip light of IP 68 rating and withstanding high temperatures suitable for steam and sauna with necessary power adoptor, etc as required
Supply and fixing of hanging lights of white powder pendant finishing of Jaquar make or of equivalent decorative item with necessary roof bolting arrangement, along with suitable wiring, etc
Supply and Installation of 300/305mm sweep Exhaust fan of Crompton/Orient/havells or of equivalent reputed make
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mm X 125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mm X 150mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75mm)
Supply and fixing of GI pipe 1&1/2" dia, 1.5 Mtr long for post lantern with fabrication of reduser including 1.5 sqmm copper wire
Supply and fixing of garden light of stainless steel royal gate light 300 mm dia clear tinted diffuser IP 54 suitable for 14 watt LED lamp.
Supply and fixing of 14 watt LED pin type bulb of Crompton/Syska/Philips/Surya/Bajaj or equivalent reputed make
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. with mounting bolt of 10 mm x 25 mm including form work etc. as required. ( 0.25 cum with 4 no mounting bolt)
Supply, Fabrication & connections of outdoor type pole box (size 200mm x 150mm x 100mm ) including the accessories like terminal box, 10A Kitkat Fuse, Clamp, etc as required
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (2 x 1.5 sq. mm)
Supplying and fixing 63 amps rating, Double Pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required with MCB of Havells/L&T/ABB/Schneider or of equivalent reputed make
Supply and installation of white / blue LED strip light as pe IP 65 suitable for 230 volt 50 Hz AC supply 2 watt per Mtr
Supply of connecting adoptor for above LED strip light
Painting of post top lantern pole of size 1 ½" X 1.5 mtr ( Approx) and pole box of size 200mm x 150mm x 100mm by one coat of red oxide primer and two or more coat of aluminium paint of reputed make including cost of cleaning of the pole by emery paper and wire brush and cleaning of post top lantern cover by washing powder as required .
Supply of 10 mtr steel tubular pole suitable for street lighting arrangement
Supplying and drawing 2 core 1.5 sq.mm insulated cable of FRLS PVC insulated copper conductor, in the existing pole as required
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Above 8.00 metre and upto 11.00 metre)
Painting of street light pole of 8 to 10 meters height including arm and pole box with one coat of red oxide primer and two or more coat of aluminium paint of reputed make including cost of cleaning of the pole by emery paper and wire brush etc as required
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Supplying and fixing of Double arm bracket of 50 mm dia X 1.50 metres long G. I. pipe (light class) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape with necessary fitting with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply and installation of 150 watt LED street light assembly of Syska/Havells/Bajaj or equivalent reputed make
Supply and laying of aluminium, 4 core 10 sq.mm size, multi-stranded, armoured, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of Polycab/Finolex/havells or equivalent reputed make
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Erection of Basket ball pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required along with suitable wiring with 2 core, 2.5 sq.mm cable
Painting of existing basket ball pole with suitable coating of red oxide and aluminium paint
Supply and fixing of 06 nos. 400W light fittings with suitable MS angle of 2 mtr on each pole of Syska/Bajaj/Jaquar/Havells or of equivalent reputed LED make
Supply, Fabrication & connections of outdoor type pole box (size 300mm x 300mm x 150mm ) including the accessories like 4 way terminal box - 06 nos., , 16A Kitkat Fuse - 06 nos. Clamp, Glands, etc
Supply, Fabrication & connections of outdoor type pole box (size 300mm x 300mm x 150mm ) including the accessories like 4 way terminal box - 06 nos., , 16A Kitkat Fuse - 06 nos., 10A SP MCB - 03 nos., 16A SP MCB - 01 no., 16A Switch & 16A Socket, Clamp, Glands, etc
Air Conditioning Arrangement
Supply of Variable refrigerant volume/flow modular type air-conditioning system suitable to operate from 360-440 volt, 50 Hz, 3 phase AC power supply with Heating & Cooling function. The condensing unit should have multiple compressor i.e. Outdoor units with capacity more than 20 HP should have minimum Two (2) numbers of inverter compressor. The condensing unit shall be have 4-way type heat exchanger with factory- assembled unit housed in a sturdy weatherproof casing constructed from rust proof galvanized powder coated steel panels. The compressors shall be of Inverter driven variable speed type scroll or twin-rotary type, capable of changing the capacity in accordance to the cooling load requirement. The condenser coils shall be constructed out of copper tubes mechanically bonded to aluminum fins. All necessary safety devices shall be provided to ensure safe operation of the system. Outdoor Unit as per quantity given below including full charging of R-410A / R407 Green refrigerant gas complete as per specifications. The system will be capable of cooling with external ambient temperatures upto 52°C. Minimum EER should be MIN 3.3 at 100% load at AHRI conditions. (Make: CARRIER / TOSHIBA/MITUBUSHI or of equivalent reputed make ) 34 HP
Supply of High static Ductable Indoor units capacity as mentioned below with remote 8 TR
VRF Y JOINTS FOR BRANCH DISTRIBUTION REFRIGERENT PIPE JOINTS Indoor branch joints
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia (OD) (Soft drawn) 13 MM INSULATION
9.5 mm dia (OD) (Soft drawn) 13 MM INSULATION
12.7 mm dia (OD) (Soft drawn) 13 MM INSULATION
15.86 mm dia (OD) (Soft drawn) 13 MM INSULATION
19 mm dia (OD) (Hard drawn) 13 MM INSULATION
22.2 mm dia (OD) (Hard drawn) 13 MM INSULATION
25.4 mm dia (OD) (Hard drawn) with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with 19 mm thick insulation
31.8 mm dia (OD) (Hard drawn) with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with 19 mm thick insulation
Supply & installation of site fabricated GSS Ducting as per IS 655 with neoprene gaskets, elbows, vanes, hangers, supports etc as per approved drawing'
Supplying and fixing thermal insulation 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on duct
Supply and fixing of accoustic insulation of supply/ return air with c- Insulation using Arma sound or equivalent material with 9-13 mm thick as reqd.
Suppling and fixing of powder coated, extruded aluminium grille/ diffuser with volume control dampers
Suppling and fixing of powder coated, extruded aluminium grille/ diffuser without volume control dampers.
Supplying and fixing of volume Control Dampers
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
a) Fire Damper
b) Actuater
Canvas Connection
Supply ,Installation and Testing of rigid PVC Drain Piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
25 mm dia
SITC of GI perforated Cable Tray for the refrigerant pipe hanging & Covering
Supply & fixing of control cum transmission wiring of Copper conductor cable along with PVC conduit for looping between indoor & outdoor VRF system.
2 C X 1.5 Sq. mm
Additional Refrigerant charging
Installation & commissioning of above system
Cable trench
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement:3 coarse sand (zone-lll) derived rrom natural sources :6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns for mass concrete
Centerin8 and shuttering including strutting, proppin8 etc. and removal of form work for : etaining walls. return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positioh and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -Allwork up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-lll) derived from naturalsources :3 graded stone aggre8ate 20 mm nominalsize de rived from natural sources)
Providing, hosting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain windowsills and the like, including the cost of required centering, shutterin8 but, excluding cost of reinfo.cement with 1:1.5:3 (1 cement : 1.5 coa.se sand (zone-lll) derived from naiuralsources : 3 graded stone ag8regate 20 mm nominalsize derived from natural sources).
Structural steel work in single section, fixed wit or without connecting plate, including cutting, hoisting, fixing in position and applying a priming cost of approved steel primer all complete
6mm cement plaster 1:3(1 cement:3 fine sand) finished with a floatng coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of R.C.C slabs and beams
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S LIGHT PALACE
CONTROL TECH ENGINEERS
GOURI BIDYUT CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .