SITC of Street Lights and Allied Works in 2nd Phase at Various Location of BHU, Varanasi
2026_BHU_930756_1
UED/2026/16102026-1
Open Tender
Electrical Works
Works
90 days
UED BHU VARANASI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Registrar, Banaras Hindu University
₹2.6 L
16 Oct 2026
16 Oct 2026
30 Oct 2026
16 Oct 2026
27 Oct 2026
16 Oct 2026
16 Oct 2026 - 22 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 6 mtrs. height made from 3 mm thick HR Steel plate having bottom dia. of 130 mm & top dia. of 70 mm complete with window sleeve type cover arrangement at a height of 0.5 mtrs from the base for cable termination block welded on both ends etc. and galvanized base plate of size 220 mm x 220 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination.
Supply & fixing 6 mm thick laminated mounted sheet inside the window i/c providing mounting arrangement etc. complete as reqd.
Supply and fixing 63 amps. terminal block 8 nos. suitable for 1.1 KV grade 4CX 16 sq. mm Armoured cable on DIN channel i/c pdg. and fixing DIN channel of suitable length on the existing laminated sheet.
Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 No., earth stud -1 No., welded at suitable height one nos. washers, springs washers & nuts. Provision on suitable height one nos. washers sprinings washers & nuts. Provision on suitable height for fixing of additional bracket Cable supports clamps suitable for 4x10 /4 x 16 sq. mm cable.
(Make:-Valmont/Bajaj/RR Ispat/Paruthi/Utkarsh/BPP/Transrail)
(Drawing & pole should be approved by the Engineer In-charge) | 262 | Nos. | 13,413 | ₹35,14,206 |
| 2 | Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size 450 mm (L) X 450mm wide and 1200mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia. 1350 mm long (approx) 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia -1800mm (approx) 8 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing 40 mm dia. (O.D.) DWC, HDPE pipe of 0.3 mtrs. length for cable entry & exit as reqd.
(Drawing & Foundation should be approved by the Engineer In-charge) | 262 | Nos. | 4,721 | ₹12,36,902 |
| 3 | Supplying and Fixing 4 Nos. 20 mm dia. X 600mm long GI foundation bolt(EN8 grade) with nuts, washer including 2 Nos. template of 2 mm thick size 220mmx220mm with 4 Nos. 24mm dia. holes to match with PCD of Pole base plate as reqd. | 262 | Nos. | 1,367 | ₹3,58,154 |
| 4 | Fabrication, supplying & fixing of single/double/triple over hang galvanized arm bracket made out of Suitable dia. & 500 mm to 1500 mm long & top tube with suitable dia. etc. complete as required. (Design as approved by Engineer In-charge). | 1,350 | Kg | 128 | ₹1,72,800 |
| 5 | Supplying and drawing following size of PVC insulated copper conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.
(Make-Polycab/L& T/Finolex/Havells/KEI)
3 core 1.5 sq.mm 1.1 KV grade | 1,900 | Mtr. | 109 | ₹2,07,100 |
| 6 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Make-Polycab/Crompton/Wipro/Philips/Havells/Lighting Technology/Trilux/Surya/Orient/Regent)
120 Watt | 270 | Nos. | 2,612 | ₹7,05,240 |
| 7 | LED Flood Light, powder coated pressure di cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Make Polycab/Crompton/Wipro/Philips/Havells/Lighting Technology/Trilux/Surya/Orient/Regent)
150 Watt | 72 | Nos. | 3,166 | ₹2,27,952 |
| 8 | Supplying, fabrication & installation of outdoor type cubical feeder pillar of front area size 1 sq. mtr. (Prox.) depth not less than 40 cm, made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized having 4 strip busbar of 200 Amp capacity double door with locking arrangement for protection from rain, dust, duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) and having Apron upto 45cm above ground from three sides & arrangement for fixing of following accessories mouted inside the cubical panel i/c making connection, inter connection with aluminium thimbles, earthing with two nos. earth struds duly Powder coated complete etc. as reqd. (Drawing of Feeder Pillar should be approved by E-in-C before installation at site) i/c supplying & fixing of following accessorries in the existing cubical panel board/feeder pillar including connection testing etc. as reqd.
a. 63 Amp, 16 KA TPMCCB -1No.(Ics=100% Icu)
b. 6A Double pole C Cure 10 KA MCB - 1 No.
c. Selector switch for auto mannual operation- 1 No.
d. 20 to 32 Amp, TPMCB, 16 KA - 3 No
e. Indication lamps (RYB) with control HRC fuse with fuse fitting- 3 Nos.
f. Power contactor 3 pole -70 Amp-1No.
g. Digital Timer with 230 V AC coil Voltage-1 No
h. Neutral link 4 way 63 A- 1 No.
i Manual push button switch (Auto-1, Manual-1)
j. Danger Notice plate- 2 Nos. | 8 | sets | 72,761 | ₹5,82,088 |
| 9 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 4Cx10 Sq. mm UG cable size in the existing RCC/ HUME/ METAL pipe etc. as required
(Make-Polycab/Universal/Grandlay/Gloster/Havells/KEI) | 5,632 | Mtr. | 402 | ₹22,64,064 |
| 10 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 4Cx25 Sq. mm cable size in the existing RCC/ HUME/ METAL/DWC pipe etc. as required.
(Make-Polycab/Universal/Grandlay/Gloster/Havells/KEI) | 700 | Mtr. | 524 | ₹3,66,800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Bid_Document01.pdf
Tender Documents • 1.31 MB
BOQ_978067.xls
BOQ • 0.26 MB
Corrigengum.pdf
PDF • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .