Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.3 L+₹33,616.95 (1.35%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹28.9 L+₹3.9 L (15.6%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
18 Nov 2020, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
SPECIAL REPAIR TO CONCERTINA COIL AND BARBED FENCING WIRE AT CERTAIN PLACES AND PROVISION OF CERTAIN SANCTIONED WORKS AT AF STN KANHERI HILLS UNDER GE AF THANE
2020_MES_386487_1
8964/E8
Open Tender
Civil Works
Item Rate
180 days
THANE
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE AF THANE
₹52,000
Yes
25 Feb 2021
14 Oct 2020
20 Nov 2020
14 Oct 2020
18 Nov 2020
31 Oct 2020
14 Oct 2020 - 31 Oct 2020
Amount
Surface dressing n.exc 15 cm deep in hard/dense soil , complete all as specified and as directed.
Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and getting out hard /dense soil.
Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and laying of Water Main /Pipe, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/loose Soil, complete all as specified and as directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in hard/dense soil , complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Surplus Soil providing Heaps along the Route of the Pipe Line in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated materials, in soil ,not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Removing excavated material exc. 500m but n exc. 1.50 km and depositing where as directed ,complete all as specified and as directed.
M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface ,complete all as specified and as directed.
M&L for Plain Cement concrete in foundations, filling and mass concrete ,type B-2 (1:2:4) using 40mm graded stone aggregate as in foundations, filling & mass concrete ,complete all as specified and directed by Engr-in-Charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete ,type C-2 (1:3:6) using 40mm graded stone aggregate as in foundations, filling & mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete ,type D-2 (1:4:8) using 40mm graded stone aggregate as in foundations, filling & mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete ,type B-2 (1:2:4) using 40mm graded stone aggregate in surface channels and for benching of drains, complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions ,complete all as specified and directed by Engr-in-Charge. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after
M&L for plain cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in SSR Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating ,complete all as specified and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete block masonry type C-1, 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed by Engr in Charge
M&L for Providing precast cement concrete type B1 , 1:3:6 (using 20mm graded stone aggregate) as in drain cover slab of any section with plain fair faces including chamfers, weatherings, throating etc and setting in cement mortar 1:4 complete with joints to match.complete all as specified and directed by Engr-in-Charge.
M&L for RCC type B1, 1:2:4 (using 20mm graded stone aggregate) nominal mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M& L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc (Inner girth only measured), complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound , complete all as specified and directed by Engr-in-Charge.
M&L for Brick work by using old size bricks ,with sub class 'B' bricks ,straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for brick work by using modular bricks with sub-class‘B’ bricks, built in CM 1:6 straight or curved on plan exc 6m mean radius, complete all as specified and directed by Engr-In- Charge
M&L for Providing ,black granite (of any type) 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite , complete all as specified and directed by Engr-In- Charge
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) on flat rough finished surface of concrete , complete all as specified and directed by Engr-In- Charge
M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, on flat rough finished surface of concrete . (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item of SSR No.07010) , complete all as specified and directed by Engr-In- Charge
M&L for Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads, Exc 13 Sq cm & n Exc 25 Sq cm, in 2nd class hardwood, complete all as specified and directed by Engr-In- Charge
M&L for Plain fillets, square, rectangular or triangular in section, clean sawn, secured with mills or brads, not Exc 3 Sq cm,in 2nd class hardwood , complete all as specified and directed by Engr-In- Charge.
M&l for making Chamfers, splays, grooves, rebates, rounded angles, rounded nosings, tongued and grooved edges (each tongue and each groove measured) etc., exc 3mm but n. exc 75mm girth on softwood , complete all as specified and directed by Engr-In- Charge.
S&F 75 mm brass handles, cast type , polished bright , complete all as specified and directed by Engr-in-Charge.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed by Engr-in-Charge
S&F framed works such as grills gratings etc, with ends of bars shoulders and or reveted, or forged into spike framed guard bars barred iron doors ladders framed balusters, walk way railing , frame work of water tank and similar work con- forming Fe.290 Gde-E-165 , complete all as specified and directed by Engr-in-Charge
Ditto as per item Item No-30 above but for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 , complete all as specified and directed by Engr-in-Charge.
S&F Mild steel rag or lewis bolts,(diameter of neck is 12mm) screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 15cm long , complete all as specified and directed by Engr-in-Charge
M & L for TMT bars 10 mm dia and over, cut to length bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips ,quality confirming to TMT bars ,complete all as specified and directed by Engr-in-Charge.
Ditto as per Item no-34 above but for 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
S&F rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc.(cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe-410-W (Gde E-250 quality B), complete all as specified and directed by Engr in Charge.
S&F Plates (plain or chequered) channels, Square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming Fe-410-W (Gde E-250 quality B) , complete all as specified and directed by Engr in Charge.
M&L for rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc and similar work conforming Fe-290 (Gde-E-165) , complete all as specified and directed by Engr in Charge.
S&F steel work as in tubular (round/square/ rectangular shape of pipes as approved by Engr-in-Charge) trusses upto height 3 mtr including post special shaped washers etc complete incl necessary nut bolts wind tiles and gusset plates etc using ERW or induction butt welded tubes conforming to IS 1161-1998 grade Yst-240 , complete all as specified and directed by Engr in Charge.
S&F mild steel welded steel wire fabric (Weight per square metre) Exc 4 kg per Sqm fixed to wood or steel members ,The rates include for straightening rolls of sheets, and raking or circular cutting and waste , complete all as specified and directed by Engr in Charge.
Fixing only mild steel welded steel wire fabric Exc 4 kg per Sqm fixed to wood or steel members, complete all as specified and directed by Engr in Charge.(Note: The reusable material retrieved from dismentaling shall used under this item)
Restraining and resecuring including making good staples etc.of exiting galvanised barbed wire and fixing to any type of standard rails straining bolt including securing or tying at crossing with and provision of galvanised M.S wire stapes or steel pins, etc or direct (each line wire to be measured) complete all as specified and directed by Engr in Charge.
S&F galvanised 2 strand, steel barbed wire(min galvanising 140 gsm) 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc( each line with to be measured, complete all as specified and directed by Engr in Charge.
S&F rolled sections with ERW or induction butt welded MS tubes black conforming to IS 1161-1979 grade St 240 as in main and cross beam, hip and jack rafters, parlins when connected to common rafters, and running rails & guides for sliding door, fixed with angle cleats or other connecting plates , complete all as specified and directed by Engr in Charge.
M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr in Charge.
M&L for medium density fibre (MDF) board ,exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work or SS trolley's with necessary clits and clamps,complete all as specified and directed by Engr-in-charge,of the following sizes:-
For (MDF) board 12mm
For (MDF) board 18/19mm
M&L for 75mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) laid in alternate bay as in path / flooring / hardstanding etc finishing the concrete surface even and fair ,complete all as specified and directed by Engr-in-charge
M&L for 50mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base etc. finishing the concrete surface even and fair, complete all as specified and directed by Engr in Charge.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base ,complete all as specified and directed by Engr-in-Charge.
S&F coloured Glazed ceramic tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick in CM 1:4 as backing coat to receive skirting / dado or tile, complete all as specified and directed by Engr-in-charge.
M&L Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc., as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick in CM 1:6 as backing coat to receive floors ,complete all as specified and directed by Engr-in-charge.
Labour only for fixing dismantled machine pressed precast concrete interlocking paver block with grey cement and no pigment and match the existing surface, ,complete all as specified and directed by Engr-in-charge.(Note : Paver block obtain from dismentailing shall be used against this items)
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment to match over 10mm thick in CM 1:6 as backing coat to receive floors ,complete all as specified and directed by Engr-in-charge.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises ,complete all as specified and directed by Engr-in-charge.
M & L for Rendering 10mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished the surfaces even and smooth and without using extra cement , complete all as specified and directed by Engr-in-charge
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall and finishing the surface withwith sagol finish to internal surfaces wall , complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement complete all as specified. Note: Water proofing compound will be measured and paid seperately, complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint , complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash , complete all as specified and directed by Engr-in-charge.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane ,fixing cabinet shutters with necessary screw/fittings and other accessory , complete all as specified and directed by Engr-in-charge.
M&L for preparation of new or previously untreated surface of wood & wood based surfaces over 10cm width & applying two coats of synthetic enamel paint ((ordinary tint) (eachcoat)) over a pink primer as a priming coat , complete all as specified and directed by Engr-in-charge.
M&L for preparation of old steel surfaces of any description over 10 cm in width or girth not otherwise described and apply one coat of synthetic enamel paint (ordinary tint) , complete all as specified and directed by Engr-in-charge.
M&L for preparation of old steel surfaces of angle iron of boundry wall with fixed barbed wire and concentrina coil, priming with red oxide zinc chrome, and applying one coat of Synthetic enamel paint (ordinary tint) ,complete all as specified and directed by Engr-in-charge.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coat of synthetic enamel paint (ordinary tint) over a coat of red oxide primer ,complete all as specified and directed by Engr-in-charge.
Labour only for disconnecting existing over head tanks of capacity exc.500 and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment ,cleaning etc and hoisting if required ,reconnecting and re-fixing in position after necessary work without damaging to existing services etc ,complete all as specified and directed by Engr-in-charge.
S&F, in repairs ,110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints , laid in trenches or in floors or fixed to walls ,complete all as specified and directed by Engr-in-charge.
S&F 110mm bore PVC (SWR) bends any radius provided with access door ,complete all as specified and directed by Engr-in-charge.
M&L for Cement Concrete bed to drain pipes bore of pipe is 100 mm ,including packing under and completely surrounding pipes with concrete after they are laid and tested in cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) ,complete all as specified and directed by Engr-in-charge.
M & L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ in 100 thickness of concrete slab,complete all as specified and directed by Engr-in-charge.
Demolition of brickwork or stone boulders masonry built in built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles ,complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level),complete all as specified and directed by Engr-in-charge.
Demolition of reinforcement cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided ,complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) of any description and in any position provided as in roof padding, roof curb etc,complete all as specified and directed by Engr-in-charge. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.
Demolition of cement Concrete (unreinforced) in Roofs, floors (other than ground floors), beams,staircases, landing, chajjas, and similar suspended work ,complete all as specified and directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for fencing, carefuliy without damaging existing structure ,complete all as specified and directed by Engr-in-charge.
Dismantling fencing wire mesh, any type,complete all as specified and directed by Engr in Charge.
M&L for Stainless steel trolley made with perforated sheet of not less than 1.52 mm thick and SS edging and bottom wire not less than 4mm dia ,slided over SS telescopic runners which is fixed to wall or stone with suitable screws and other connected accessory of desired shape and size ,complete all as specified and directed by Engr-in-charge. (Note : SS telescopic runner shall be paid under relevent item of Sch A)
S&F Stainless steel soft close hydraulic action hinge with capacity to take load of 12 to 20 mm thick board with suitable screws and other connected accessory required for fixing shall be included in quoted rates ,complete all as specified and directed by Engr-in-charge.
S&F magnetic catcher brass body and striking plate with aproved quality with suitable screws and other connected accessory required for fixing shall be included in quoted rates ,complete all as specified and directed by Engr-in-charge.
S&F heavy duty SS Zink plated Telescopic runners for SS trolleys having fully extended length min 500mm and 45.4 mm wide, loading capacity 45 kg/pair including concealed screws and bolts fixed to the wall or stone with suitable screws and other connected accessory of desired shape and size ,complete all as specified and directed by Engr-in-charge.
M&L for Drilling holes of 25 mm dia through cuddappah stone and RCC slab together of thickness 100-250mm ,complete all as specified and directed by Engr-in-charge.
S& F in repair GI punched type concertina coil of 900 mm dia obtained from old wall duly streched & fixed to angle iron posts/ struts with 3mm thick punch/clip/staple or steel pins, complete all as specified and directed by Engr in Charge.(Note: Seviceable GI punched type concertina coil retrieved from demolition or dismentailing shall be used against this item)
S& F in repair GI punched type concertina coil of 550 mm dia obtained from old wall duly streched & fixed to angle iron posts/ struts with 3mm thick punch/clip/staple or steel pins ,complete all as specified and directed by Engr in Charge.(Note: Seviceable GI punched type concertina coil retrieved from demolition or dismentailing shall be used against this item)
S & F GI punched type concertina coil of 900 mm dia duly streched & fixed to angle iron posts/ struts with 3mm thick punch/clip/staple or steel pins,complete all as specified and directed by Engr in Charge.
S & F GI punched type concertina coil of 550mm dia duly streched & fixed to angle iron posts/ struts with 3mm thick punch/clip/staple or steel pins, complete all as specified and directed by Engr in Charge.
Removing existing water proofing treatment where so ever exist (except concrete padding) and removing debris/rubbish off the site,complete all as specified and directed by Engr in Charge.
Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (MAKE : TEXSA/BITUMAT/BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
Supply only integral water proofing liquid admixture for concrete and mortar,,complete all as specified and directed by Engr in Charge.(Make :CONPLAST X421IC of Fosroc /SIKA No 1 of SIKA/equivalent brand of PIDILITE)
S&F Oil and GREASE TRAP fabricated of Stainless steel having size 42" x 24" x 30" having 3 compartment Manual fully stainless steel 304 Grade with perforated sludge Basket including Lid and all conected fittings and fixture etc complete all as specified and directed by Engr-in- Charge.
Supply, Install, Testing and commissioning of water heater storage type, energy efficient, five star rating electric supplied and installed capacity 25 ltrs including conecting to with PVC pipe 450 mm long for incoming and outgoing water supply with all arrangement of hanging of water heater with required nut bolts, washers ,complete all as specified and directed by Engr in Charge.
M&L for Self-closing taps, 15mm bore dia ,cast copper alloy, chro-mium plated, screwed for iron pipe and fixed ,complete all as specified and directed by Engr in Charge.
S&F MCB SP 6 to 32 Amps single pole 240 V AC, 'B' Series ,complete all as specified and directed by Engr in Charge.
M & L GI tubing (Medium grade) with all fitting and fixtures ,fixed on wall or ceiling or laid in trenches of size 15 mm bore ,complete all as specified and directed by Engr in Charge.
M & L for PVC Connection 15mm dia size ISI marked with PTMT Nuts of length 450 mm, complete all as specified and as directed. MAKE : POLYTUF/ PRAYAG
M & L for stop valve ,15 mm bore pipe, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated ,complete all as specified and directed by Engr in Charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non- metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way,complete all as specified and directed by Engr in Charge.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 3 Pin, ,complete all as specified and directed by Engr in Charge.
M & L for wall mounting fan AC 230 Volts 50 Hz single phase 450 mm sweep, energy efficient, five star rating, with built on ON/OFF & speed regulator inside mounting base oscillating type with aluminium alloy one piece blade double ball bearing heavy duty motor sturdy close mesh guard stainless steel stem having vertiical angle adjustmenty from 22 degree to 45 degree including grouting of MS rugged studs/bolts inwall/column for mounting the fan ,complete all as specified and directed by Engr in Charge.
M&L for Supply and fix exhaust fan, heavy duty 450 mm sweep, 1400 RPM enrgy efficient, with louvers, Single phase, 50 Hz with three core twisted cable of size 23/0.0076 for connecting upto ceiling rose and cutting of wall for fixing the exhaust fan of size 380 mm and making the surface good including masonary work, cement plastering applying distemper job to match the existing colour c,complete all as specified and directed by Engr in Charge.
S&F MCB DB 4-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded in Wall including Concealed upto Wall Surface including connecting with existing Cable Incoming and Outgoing with Cable Lugs as per the requirement and and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the existing Finishes, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Supply and Fix MCB SP, 40 Amps 240 Volts, 50Hz, 10KA ,complete all as specified and directed by Engr in Charge.directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 6 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0 mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET OUTLET 6 AMP ON THE SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Rigid Non- metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and making Good in Cement Mortar 1:3 mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. including 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor connected to Common Earth dolly for ONE 3 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
Supply & laying XLPE insulated, Screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electric Power Cable Earthed, heavy duty, 1100 Volt grade with Aluminium Conductor, ISI marked, IS:7096, Cross sectional area 25 Sqmm, 3½ Core, laid in Trenches, Duct, through Pipe or laid in Floor or fixing to Pole, jointing and testing including taking down/ out Cable, complete all as specified and as directed.
Supply and lay in trenches PCC cable cover class LV, type 1, flat of size 250 mmx150 mmx 40 mm for cable protection ,complete all as specified and directed by Engr in Charge.
M&L for fine sand cushioning in trenches 80 mm thick before laying the cable and 150 mm thick after laying the cable ,complete all as specified and directed by Engr in Charge.
S&F Crash bell Single phase, 50 Hz ,complete all as specified and directed by Engr in Charge.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, ,complete all as specified and directed by Engr in Charge.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level ,complete all as specified and directed by Engr in Charge.
S&F Powerline vertical type TPN DB 4 way Double Door for accommodating Incoming MCCB Four Pole 100 Amp rating, regal gray colour, sheet steel phosphatised, powder coated, with bus bar, neutral link earth bar & din rail duly embedded in wall incl. concealed upto wall surface incl connecting with existing cable in coming & out going with cable lugs as per the requirement and making disturbed surface good to match with the existing complete,complete all as specified and directed by Engr in Charge.
S& F pipe galvanised medium grade 25 mm dia , with all fitting; laid in trenches including fittings ,complete all as specified and directed by Engr in Charge.
S&F Gun Metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 25 mm dia ,complete all as specified and directed by Engr in Charge.
Cutting of existing CI or GI Pipe line Dia 50 mm for inserting Tee 80 x50 x 80mm for branch line ,complete all as specified and directed by Engr in Charge.
S&F stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 25 mm bore pipe,complete all as specified and directed by Engr in Charge.
M&L Sub-main Wiring with 4-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked and its Accessories including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
S&F Rigid non metallic PVC conduit 25 dia (external ) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc,complete all as specified and directed by Engr in Charge.
M&L for earthing complete with Copper earth plate electrode 600x 600x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 5 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii). Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate.
S&F Rotational moulded polyethylene water storage tanks ,1000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including making inlet/outlet water connection with fixtures and fittings ,complete all as specified and directed by Engr in Charge.
S&F in repair MCB Triple Pole & Neutral, 63 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz ,complete all as specified and directed by Engr in Charge.(Note : Material retrieved from repair shall be used against this item)
M&L Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked and its Accessories including 1-Run of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes,complete all as specified and directed by Engr in Charge.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity of 1.5TR ,complete all as specified and directed by Engr in Charge.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked and its Accessories including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes,complete all as specified and directed by Engr in Charge.
Supply and fix single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20 amps ,complete all as specified and directed by Engr in Charge.
M&L for Supply and fixing Voltage Stabilizer of capacity 5 KVA with Intelligent Time Delay System, Low and High Voltage Protection, Latest IC Technology, Thermal Overload Protection, Wall Mounting Cabinet design, Input 130-300 , 50 Hz ,complete all as specified and directed by Engr in Charge.
Safe Construction Co.
Nissan Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .