Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC SAI VILLA C 65 EKTA NAGAR BAREILLY UTTAR PRADESH 243 122 | BAREILLY | UTTAR PRADESH | 243122 | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.5 Cr+₹4.2 L (2.87%)Rejected-Finance | ₹1.5 Cr+₹4.2 L (2.87%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.5 Cr+₹6.9 L (4.74%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr+₹6.9 L (4.74%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.5 Cr+₹7.2 L (4.96%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr+₹7.2 L (4.96%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.5 Cr+₹7.7 L (5.26%)Rejected-Finance NO 9 LAKSHMI NIVAS SOMASHETTAHALLI CHIKKABANAVARA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹7.7 L (5.26%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | A.GOVINDARAJ L5 | devan enterprises L3 | Maruthi constructions L9 | RMK PROJECTS L10 | LAKSHMI CONSTRUCTIONS L4 | shashi shekar construction L6 | UNIVERSAL ENGINEERING L4 | RAMESH BABU CO L7 | M/S SRI BALAJI ENTERPRISES L8 | SREE BUILDERS L2 | NORTH INDIA PEST CONTROL L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facia for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermax Limited( as approved by GE) and cleaning the steel reinforcement properly, complete all as per manufactures instruction and all as specified and directed by Engineer-in-Charge.allowed to dry. | 30 | Sqm | 1,100 ₹33,000 | 1,850 ₹55,500 | 1,300 ₹39,000 | 888 ₹26,640 | 850 ₹25,500 Lowest | 1,490 ₹44,700 | 850 ₹25,500 Lowest | 980 ₹29,400 | 1,100 ₹33,000 | 1,850 ₹55,500 | 1,198 ₹35,940 |
| 2.00Note :- (a) Providing cement based angle fillet for 75mm X 75mm admixer with Sikacim, integral waterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’s instructions over a coat of acrylic emulsion bonding agent, such as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosroc chemicals, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like rougheing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 bar pressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc complete all as manufactures instructions and all as specified and directed by Engineer-in-Charge. (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. | ||||||||||||||
| 3.00(b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. | ||||||||||||||
| 4.00c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make from M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd, (as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface,complete all as specified and directed. | ||||||||||||||
| 5.00(d) Note : The work under (Item No. 1 to Item No. 4 of BOQ) shall be carried out through authorized and qualified applicators from any of the following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermax Limited | ||||||||||||||
| 6.00(e) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified | ||||||||||||||
| 7.00(f) The unit rate quoted is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land. Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs. | ||||||||||||||
| 8.00 | M&L for cleaning and removing all corrosion scales , rust , etc using emery / wire brush and finally cleaning using rust remover & cleaning agent that is one part alkaline based material, with corrosion inhibitors and dispersing agents and supplied as a clear brown solution. The specific gravity shall be 1.2 – 1.22 @ 25°C. The pH value shall be between 9.5 to 10 and the coverage shall be 5 – 6 m2/ L as per manufacturer instructions complete all as specified and directed by Engineer-in-charge. | 5 | Sqm | 530 ₹2,650 | 100 ₹500 Lowest | 550 ₹2,750 | 406 ₹2,030 | 500 ₹2,500 | 403 ₹2,015 | 500 ₹2,500 | 351 ₹1,755 | 600 ₹3,000 | 450 ₹2,250 | 497 ₹2,485 |
| 9.00 | M&L for repair to cracks and damaged existing surfaces by Hydrogen Free Expanding And Plasticising Additive . It plasticizes the mix, allowing for substantial reduction in water without affecting the fluidity, thus improving the strength and impermeability, the admixture/ additive in cement to provide non‐shrink properties Cementitious Cable Encapsulation .
(a). Fixing of pvc nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing pvc nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depth complete all as specified and directed. | 10 | Each | 290 ₹2,900 | 50 ₹500 Lowest | 300 ₹3,000 | 256 ₹2,560 | 250 ₹2,500 | 205 ₹2,050 | 250 ₹2,500 | 251 ₹2,510 | 350 ₹3,500 | 300 ₹3,000 | 318 ₹3,180 |
| 10.00 | M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm @ 3 hours and and ultimate compressive strength of 70N/mm in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983as per manufacturer instructions complete all as specified and directed by Engineer-in-charge. | 10 | Each | 145 ₹1,450 | 100 ₹1,000 | 150 ₹1,500 | 122 ₹1,220 | 100 ₹1,000 | 95 ₹950 Lowest | 100 ₹1,000 | 120 ₹1,200 | 120 ₹1,200 | 150 ₹1,500 | 157 ₹1,570 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
12 Dec 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF DAMAGED ROOF FACIA PROJECTION OF BLDGS ROOFING WELCOME MAINTENANCE INCLUDING CERTAIN ELECTRICAL REPAIR WORKS AND MISC B R WORKS AT AFTC 2 DC AREA CQAE WE AND AFS JALAHALLI
2025_MES_739932_1
8237/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer M AF Jalahali
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.3 L
31 Dec 2025
14 Nov 2025
19 Dec 2025
14 Nov 2025
12 Dec 2025
5 Dec 2025
14 Nov 2025 - 21 Nov 2025
Amount
M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facia for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermax Limited( as approved by GE) and cleaning the steel reinforcement properly, complete all as per manufactures instruction and all as specified and directed by Engineer-in-Charge.allowed to dry.
Note :- (a) Providing cement based angle fillet for 75mm X 75mm admixer with Sikacim, integral waterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’s instructions over a coat of acrylic emulsion bonding agent, such as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosroc chemicals, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like rougheing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 bar pressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc complete all as manufactures instructions and all as specified and directed by Engineer-in-Charge. (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry.
(b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry.
c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make from M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd, (as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface,complete all as specified and directed.
(d) Note : The work under (Item No. 1 to Item No. 4 of BOQ) shall be carried out through authorized and qualified applicators from any of the following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermax Limited
(e) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified
(f) The unit rate quoted is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land. Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
M&L for cleaning and removing all corrosion scales , rust , etc using emery / wire brush and finally cleaning using rust remover & cleaning agent that is one part alkaline based material, with corrosion inhibitors and dispersing agents and supplied as a clear brown solution. The specific gravity shall be 1.2 – 1.22 @ 25°C. The pH value shall be between 9.5 to 10 and the coverage shall be 5 – 6 m2/ L as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for repair to cracks and damaged existing surfaces by Hydrogen Free Expanding And Plasticising Additive . It plasticizes the mix, allowing for substantial reduction in water without affecting the fluidity, thus improving the strength and impermeability, the admixture/ additive in cement to provide non‐shrink properties Cementitious Cable Encapsulation . (a). Fixing of pvc nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing pvc nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depth complete all as specified and directed.
M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm @ 3 hours and and ultimate compressive strength of 70N/mm in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for Shear thinning agents in RCC/ walls/ ceiling/ columns/ beams/floor/bricks cracks after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 8 mm complete with three components compound graded filler, E-Resins and Shear thinning agents with adjustable consistency by varying the filler component epoxy resin based complete all as specified and directed by Engineer in Charge.
M&L for applying 2 coats of two component amine cured epoxy mastic coating using Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern.it should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate.it should achieve Compressive Strength of >70 MPa after 14days, having pot life, minutes at 27⁰C, 100 g >40 mass as per manufacturer instructions complete all as specified and directed by Engineer-in-charge
M&L for providing and fixing welded MS wire mesh weighing not less than 1Kg/Sqm of size 50mmX50mm of 2.6mm dia on the prepared surface & surface should be cleaned and be removed from dirt, fungus and all foreign material complete all as specified and directed by Engineer in Charge.
M&L for removing old existing rubbish/battered/useless mixture of the binding materials such as cement / Lime and fine aggregate (<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve), fine Aggregate of any description and in any position from existing external/internal surfaces of RCC components or any surface having average profundity of 15mm (Approx height 10m from natural ground level) by hand tool that has a long metal blade with a sharp edge at the end, chisel and hammer or using robust pneumatic chisel hand tools and removal beyond MoD land including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioted/decayed loose surface complete all as specified and directed by Engr-in-charge.
M&L for applying 2 coats of primer slurry prior to the application of the repair mortar having multiple corrosion inhibiting synergies and which is a blend of pc graded fillers corrosion inhibiting additive and re-dispersible polymers in powder form mixed with water for application by brush to coat the reinforcement/steel within 10mm of the finish surface and where chlorides are present so as to achieve adhesion bond strength of 1 MPa to steel. Pot life of 0.5 hr @ 30°C. It shall be workable for not more than 15 minutes at same temperature. The mixed density shall be not more than 2.05. The water/powder ratio shall be 0.3 by weight complete all as specified and directed by Engineer-in-charge.
M&L for applying 20mm shear thinning fibre reinforced polymer modified , impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar with alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/sqmm, tensile strength @ 7days (ASTM C 307)> 3 N/sqmm, compressive strength of 35MPa at 7 day and 45MPa at 28 days, at the outer or inner RCC which provides excellent bond to concrete, Improves tensile and flexural properties of mortar, Versatile having specific gravity of 1.02 cement sand can be used for finishing purpose complete all as specified and directed by Engr-in-charge.
M&L for providing and spraying polyamine cured epoxy coating incorporating a special alkali reactive emulsion breaking system compound over the plastered surface. This impervious film prevents excessive water evaporation which in turn permits more efficient cement hydration, thus reducing shrinkage and increasing durability. It shall have a specific gravity of 1.02 and the minimum application temperature shall be 10°C and the strength of concrete complies with the internationally recognised ASTM C309-90 standards typically within the range of 200 to 285 ml/sqm, SG - 1.02 including all tools and tackles complete all as specified and directed by Engr-in- charge.
M&L for applying 3 coats of corrosion inhibiting, polymer matrix with excellent mechanical properties such as adhesion and elongation as waterproofing barrier coating. It should be non toxic and non-re-emulsifying. Should conform to JIS Z 1535 and IS-3085 and DIN-1048. having Hardness - Shore 'D' scale of 20,wet density of 1.66 g/cc, flexibility at low temperatures, tensile strength > 0.4 MPa, Elongation > 20%, adhesion to substrate greater than 1.5 N/mm², waterproofing to withstand 330 KPa positive pressure and 160 KPa negative pressure, Mixing should be done by electric rotary mixers. The substrate should be free of laitance, loose concrete, dust, oil etc. if applied on screed or any other cementitious surface the surface should be properly cured prior to application complete all as specified and directed by Engineer-in-charge
M&L for applying two coat of mixture of two monomer unsaturated liquid hydrocarbon , gaseous hydrocarbon and polymesrized them to get the high polymer dispersion emulsion successfully bonded to mortar, to improve adhesion to concrete, better durability, reduced shrinkage and increased flexibility and resistant to emulsification in damp condition modified Ensuring no porosity in new/old surface, temperatures between +5°C and +35°C, Resist to penetration of CO2 4.600 micron , compressive strength (11.5 N/mm2) at 3days strength - 11.5 (N/sqmm ) and at 28 days - 25.30N/sqmm as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
M&L for Sprinkling sand particles of saturant making mechanical key, over which applying Single component, fiber reinforced cementitious repair mortar which is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking for a thickness of 10 mm. water ratio of which shall be 0.16, 28 days compressive strength shall be 30 MPa,mixed density shall be 2.18 kg/ltr, flexural strength shall be 6 MPa for 7 days and tensile strength for 7 days shall be more than 2MPa.Its adhesion bond strength shall be greater than 2 MPa with creep strain reduction of 8%.Single component, fiber reinforced cementitious repair mortar.cement and sand can be used for finishing purpose. The modulus of elasticity of this product shall be 23-26 KN/mm² complete all as specified and directed
Note for item No. 8 to 20 :- The work for items Srl No 8 to 20 shall be executed directly by manufacturer or through their authorized and qualified applicators of any following manufacturer only. M/s Fosroc chemicals, M/s Thermax Limited, M/s BOSTIK India Pvt limited, M/s Tiki Tar Danosa India Ltd.
The contractor shall submit performance guarantee certificate for structural repair/leakage/seepage for a period of 10 years from the certified date of completion.
The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto 15 mtr height from natural ground level.
The defect liability period for the structural repair work shall be 05 (five) years from the certified date of completion of work.
A security deposit of value equal to 2.5% of the rate quoted against each item shall be retained from Final bill payment due to the contractor for the defect liability period.
The unit quoted rate is deemed to include taking up or down of water pipe, tanks, wires etc found on roof or other working areas and re-fix same at the original position after completion of work.
Adoption of necessary safety arrangement like safety belts, ropes, helmet, netting etc are required for safety of working labour at height exceeding 3 to 15 mtr shall be mandatory & deemed to be included in the unit quoted rate
Taking down cement plaster on brick or stone walls, or concrete walls including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for 15 mm thick plastering in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note :- (a) Water proofing compound shall be measured and paid seperately. (b) The unit rate quoted is deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land.
Taking down cement plaster on brick or stone walls, or concrete walls including raking out joints, hacking for key, scrubbing down with water, etc.,including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for 10mm thick cement plaster in CM (1:6) on brick work or concrete surfaces rendering is to be even & smooth without using extra cement for internal walls complete all as specified and directed.
Taking down cement plaster on brick or stone walls / ceiling , or concrete walls/ceiling including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for 5mm thick cement plaster in CM (1:3) on brick work or concrete ceiling surfaces incuding finishing even & smooth without using extra cement complete all as specified and directed
Supply only integral water proofing compound complete all as specified and as directed. Make:-Dr. Fixit/ Pidi Proof and equivalent.
M&L preparation of newly plastered surfaces wall / ceiling and applying three coats of white washing on ceiling/ walls surfaces complete all as specified and directed.
M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
M&L Repair to leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed
M&L Repair to leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall to avoid the leakage/ seepage at the site of work complete all as specified and directed.
Note for item No 34 & 35 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case leakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer's specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 75 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 110 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S&F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed.
S&F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed.
S&F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 75 mm complete all as specified and as directed.
S&F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 110 mm complete all as specified and as directed.
S&F in repairs 125/ 110 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed.
S&F in repairs PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 110 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore complete all as specified and directed.
S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 75 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed.
S&F in repair viterous china squatting pan 'Orissa pattern ' size 580 x 440mm white with integral foot rests incl connecting to 'P' or 'S' trap and to flush pipe anti syphonage pipe etc complete including provn of lime concerte bedding and making good to floor complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for ceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed.
M&L Repair to ends of chajjas/ parapets by removing old concrete, loose material & cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good with existing finishes complete all as specified and as directed. Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding.
M&L for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
M&L for preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion (APEX) weather proof paint complete all as specified and as directed.
M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint not otherwise described over 10 cm width or girth, complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint over 10 cm width or girth, not other wise described complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Petty repair to door shutters for easy closing/opening (size upto 3 Sqm) including minor repair and easing, adjustment/alignment to openable with assessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc, complete all as specified and directed.
Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm and not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down shutters of any description exc 1.0 Sqm and n.exc 2.0 Sqm each complete all as specified and directed.
M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed.
S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Factory made 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters all as specified and directed.
Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Providing and injecting chemical for post constructional Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed.
S&F Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads in section area 6 sq.cm but not exc 13 sq cm including taking down exisiting one complete all as specified and as directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm in each pane complete all as specified and directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm in each pane complete all as specified and directed.
Taking down and refixing MS window shutters n. exc 1.5 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt to the same window by necessary welding. The quoted rates shall be included the following aspect:- (a) Cutting of existing piano hinges, handle and tower bolt from window frame and shutter. (b) Fixing of removed shutter in the same frame on MS box type hinges 100mm, MS handle 100mm and MS tower bolt 100mm by welding. (c) Easing and adjusting the shutter before re-fixing if required. (d) Finishing the window frame and shutter with two coat of synthetic enamel paint. (e) Necessary scaffolding material to be included as the building height is more than 10mtr. Note : Box type hinges, handle and tower bolt shall be measured separately as supply only and labour element is deemed to be included in this item.
Supply only MS Box type hinges 50mm.
Supply only MS Handle 100mm.
Supply only MS tower bolt 75mm
Supply and fixing in repair steel window peg stay all as specified and directed.
Petty repair to easing of wooden window, wooden ventilator, cupboard door, wardrobe door, PVC door, window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments , (size upto 3 Sqm). minor repair and easying and adjustment/alignment to openable with accessories and including taking down and refixing complete all as directed.
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed.
Taking down and re-fixing the same existing aluminium door/window/partitions (each shutter area n. exc 5sqm) after carrying out certain repairs as required, removing the existing beading and fixing new (i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) rubber beading of suitable size with adhesive, overhauling of floor springs including repairing/cleaning/greasing etc and making the same fully functional all as specified and directed.
Petty repair to aluminium section/glass doors, windows, ventilators, partitions and making good the same size upto 2 Sqm (i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) included taking down and refixing complete all as specified and directed.
S&F Plate rack of size 65 cm x 96 cm (heavy duty) made of stainless steel fixed in repairs complete all as specified and directed.
Supply and fixing in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws,included rubber beading complete all as per architectural drawings and as directed.
Supply and fixing in repairs powder coated aluminium for shutters of window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, star lock, including rubber beading complete all as per architectural drawings and the directions of Engineer-in-Charge.
Material and labour for 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, including side beading fixed with screws to Aluminium frame work complete all as specified and directed.
Supply and fixing 12mm thick Veneered particle board, solid core, exterior grade, with decorative face veneers for both faces, lamination, including side beading fixed with screws complete all as specified and directed.
Supply and fixing in repairs 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed.
S&F in repair aluminium handles cast type anodised 150 mm long complete all as specified and as directed.
Supply and fixing in repairs aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
Supply and Fixing in repairs 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed.
S&F in repairs 250mm, ordinary mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one all as specified and directed.
S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed including taking existing one complete as directed.
S&F 5mm thick rubber beading strips of entrance doors having width exc 3cm and not exc 5cm to arrest entry of insects including taking down existing one complete all as specified and as directed
Applying silicon sealent on joints of wall,cill jambs roof etc complete all as specified as directed
S&F in repairs of aluminium anodised grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC15) of approved design/pattern(DG 104), with approved standard section and fixed to existing window frame with CP brass/stainles steel screws not less than 50mm and @ 200mm c/c, incl cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section ( 28mm x 19mm x 2mm thick) around the opening, complete as per site requirement and direction of EIC.
S&F 5 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 5 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50 Sqm in each pane complete all as specified and directed.
Supply & Fixing of UPVC glazed 3 track-2 panel sliding windows with mesh made out of multi chambered uPVC sections with TPE gaskets having isolated drainage and reinforced with Galvanized iron profiles throught out the window. The outer frame having an overall size of 108 x 48 mm with reinforcement of 1.2mm thickness and sash with overall size of 38 x 61 mm with reinforcement of 1.2 mm thickness mesh sash of overall size 38 x 58mm Fiber mesh reinforced with 1.2 mm of GI. Glazing bead for fixing of glass shall be of size 16mm x 19mm and TPV gasket. Windows will be provided with 5mm thick plain float glass and stainless steel wiremesh, With "Astrapia" hardware or equivalent & Single point locking system of flush lock. Wall thickness of frame & sash shall be 2-2.2mm complete all as specified and directed.
S&F in repair manually operated polyester fabric vertical venetian blinds of approved colour and pattern of any size and thickness of 0.45mm (+/- 0.05mm) including high strength aluminium alloy channel fixing with two Nos clamp including all connected fittings and fixtures for windows,ventilators etc complete all as specified and directed.
S&F in flush door 30mm thick membrane doors decorative finish on one side duly finished and polished and other side all as per manufacturers directions as per tint / colour including necessary teak wood lippings, complete all as specified and directed.
S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed.
M&L 20mm dia mild steel powder coated drapery rod cut to length required without joint in between and including mild steel powder coated fancy type brackets and fixed at openings including taking down existing one complete all as specified and directed.
M & L for re-writing letters or figures (Block, Roman, Italic or Indian) n. exc 30 cm high and width, complete all as specified and directed.
M&L 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work including taking down old complete all as specified and as directed.
S&F Decorative laminates of 0.90 mm thick type matt finish, colour and pattern as approved including taking down existing one complete all as specified and as directed.
S&F Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete including taking down old one all as specified and as directed.
S&F Magnetic catches with 8mm dia steel ball and brass body and striking plate including taking down existing one complete all as specified and directed.
S&F PVC beading for cupboard work, colour and pattern as approved. Including taking down existing one complete all as specified and as directed
Supply and fixing anodised alunimiun size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with Hangers of suitable size/ dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and including 6-8 mm thick gypsum boards designer tiles, fixed to sheet suitably placed in false ceiling grid made of aluminium/G.I./ M.S.as per pecification and drawing and including dismantling old unservicable wall and celing board & including frame with of any type and description, complete all as specified and directed.
S&F Solid PVC Wall Lining / panelling consisting of 5mm thick wooden colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing including taking down old one complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing including taking down old one complete all as specified and directed.
Supply and fixing in repairs 7 feet 4 pipes pulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm, made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit. Make Easydry or equivalent.
M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protection finishing the surface even and smooth with using extra cement, including necessary demolition of old concrete all as speecified and as directed.
Cleaning of existing tiles in wall/flooring including mirror polishing, cleaning and joints filling and apply white cement complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar (1:6) complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar (1:4) complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed.
Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface as in level course etc including demolition of existing old cement concrete, including disposal of demolition material upto 500mtr from MD land complete all as specified and directed.
Taking down existing manually/machine operated steel rolling shutters area not exc 30Sqm each and erecting in same position, after easening, applying of greasing of all parts in rolling shutters uncluding changing of anchor rod, springs, steel rolling strips, locking plate, ball bearings. locks and vertical channels all as directed. Spare parts shall be measured and paid separately, after replacement of following unserviceable parts as required for smooth functioning of rolling shutter and refixing properly including bracket complete all as specified and directed.
(a) Shaft 50mm mild steel pipe all as directed.
(b) Helical spring 600mm long all as specified and directed.
(c) Ball bearing for 50mm dia pipe all as directed.
(d) Gear box set all as specified and directed.
(e) Lath patty (strips) of 75mm wide & 1.20 mm thick MS all as directed.
(f) Crancked wheel of any size all as directed.
S & F in repairs Steel rolling shutters, in any size and any position with ball bearing, as specified including top cover, anchoring rod, shaft, lath patty,crank wheel, side cover, hood cover, locking plate, hasp and staple and one shop coat of primer; erected in position as indicated, complete manual or gear operated type. Thickness of laths 1.25mm complete all as specified and directed.
Grinding of existing mozaic/kota stone in flooring including mirror polishing, cleaning and joints filling and apply white cement complete all as specified and directed.
M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed.
Material and labour for Preparation of old plastered or unplastered surface of ceiling, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
M&L for Preparation of old decorated surfaces of walls by using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufauture instruction of required shade complete all as specified and directed.
Supply and fixing Anodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with hangers of GI wire of suitable dia (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unservicable ceiling board including frame of any type and description, complete all as specified and directed.
Supply and fixing for false ceiling as per manufacturer instructions, 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unservicable ceiling board including frame of any type and description, complete all as specified and directed.
Supply and fix polished Sadarahalli granite slab flooring 20 to 22 mm thick with grey cement slurry mixed with pigment to match the shade of the slab including 20mm thick screed bed in cement mortar 1:4 complete on staicase complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B-2 (using 20 mm graded crushed stone agg) as in hard standing and similar works with , spike rolling ,or making impression of expanded metal, while the concrete is green etc including demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises and M&L for Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.18 Sqm but n exc 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as specified and directed.
Cleaning of air/dust blokages in the internal water supply lines concealed or fixed on the wall or floor surfaces by dismantling the fitting such as taps, valves, unions etc to facilitate/stimulate clearance of blockages/airlocks and re fixing the dismantled items after clearance of blockage/airlocks including fiiitngs etc complete all as specified and as directed
Petty repair to internal/external water inlet water pipe line coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing the blockage including concealed water tubing etc of any height using scaffolding and and making the water supply functional complete all as specified and directed.
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed.
Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank of 500 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down old unserviceable tank complete all as specified and directed.
S & F in repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed.
M&L Petty repairs to leaking water in bib taps, pillar cock, stop cock, angle valve, concealed stop valve, bottle trap of any description by changing the PVC washers/ Sheet washers,spindle brass,jumper brass or any other minor accessories (incl taking down and refixing) complete all as specified and directed
S & F in repair bib tap standard of PTMT any colour screwed for iron pipe and fixed,15 mm bore (minimum weight 90gms) complete all as specified and as directed.
S & F in repairs Bib taps cast copper alloy chromium plated fancy type screwed down screwed for iron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed.
S & F in repairs pillar tap with capstan heads chromium plated fancy type screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed.
S&F in repairs of Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) complete all as specified and as directed.
S&F in repairs of pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and as directed.
S&F in repairs Vitreous China, half stall Urinal (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and as directed
S & F in repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to 'P' or 'S' trap incl connecting flush pipe with flushing rim complete all as specified and as directed.
Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed.
Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of including rubber washers, syphon set, float valve, handle,fixing to wall clamp/bracket, stopping of leakage etc wherever required complete all as specified and as directed
S & F in repairs PVC low level flushing cistern 10 Lit capacity including necessary brackets incl connecting flush pipe etc and making good the disturbed surfaces complete all as specified and as directed.
S & F in repairs 15 mm dia stop valves of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed.
S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S&F Wash hand basin table counter type 560x400x200mm vitreous china (white) with cantilever CI/Angle iron brackets embedded in concrete block, including long shank pillar tap, Brass chromium plated waste coupling 32mm bore, Waste pipe bottle trap, complete all as specified and as directed.
S&F Angular stop cock, chromium plated valves high pressure screwed both ends iron pipe or for unioins 15mm dia, including taking existing one complete as directed.
S&F in repairs Glass self assembly of 12mm thick and n exc 60cm length, 15cm wide with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets complete all as specified and as directed
Supply and fixing in repairs MS Mortise lock, 4 levers vertical type, size 100 mm for fixing to glass all as specified and directed.
S & F in repair tubular towel rail brass chromium plated 20 mm dia 'D' type 60 cm long between flanges complete all as specified and as directed.
S & F in repair Toilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screws and complete all as specified and as directed.
S&F in repairs of Swivel Shower with arm of PTMT any colour and 195mm long bend of 45 degree with flange for fixed with 15mm pipe(Minimum weight15mm-90gms) complete all as specified and as directed.
S&F PVC body cabinet box mirror of size 350mm X 450mm X 100mm of PTMT alloy of approved pattern and design including taking down existing one complete all as specified and directed.
S&F in repairs Overhead Shower rose 125mm size (Brass Chrome Plated) complete all as specified and as directed.
S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, complete all as specified and directed.
S&F in repairs grating doom 125mm dia with waste hole of Chromium plated (Min wt 40 gms) complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank of 1000 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe all as specified and directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out old u/s steel/plastic/cpvc water tubing and connections complete all as specified and directed.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out old u/s steel/plastic/cpvc water tubing and connections complete all as specified and directed.
Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified.
Supplying and fixing in repairs of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified.
Supplying and fixing in repairs 20mm outer dia CPVC brass elbow all as specified and directed.
Petty repairs to refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back with including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar to dwarf wall and connecting union to pipe, filling gap in white cement and all necessary fittings to fixed in repair (including taking down and refixing in same position) complete all as directed.
S&F Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairs all as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA.
S&F CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwed for iron pipe 15mm bore. including taking down existing one complete all as specified and as directed.
Petty repair to wall mixer,basin mixer,sink mixer etc including replacement of spindle brass, Jumper brass, rubber washer, head incl taking down and refixing ete all as specified and directed
S&F 32 mm Waste Coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing one complete all as specified and as directed.
S&F in repairs 40 mm Waste coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed one complete and all as specified and as directed.
S&F in repairs PVC waste pipe 32/40mm bore for WHB, Urinal & Sink complete all as specified and as directed.
S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified and directed.
S&F in repairs CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe in repairs 15mm bore complete all as specified and as directed.
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note : (i) The Unit rate quoted is included for demolition of old Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar. (ii) Cost of rounding of stone deem to be included in unit quoted rate.
Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping ets as per site requirement on walls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc complete for the following :- Make of wire: Polycab/Plaza/Havells Note: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 194 here in before but for One light point/fan point controlled by one way 5 Amp switch.
All as per item No. 194 here in before but for One light point controlled by two way 5 Amp switch.
All as per item No. 194 here in before but for one bell point controlled by one way bel push.
All as per item No. 194 here in before but for One 3 pin socket out let 5 Amp on the same board
All as per item No. 194 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per item No. 194 here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed.
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F in repair and replacement of MCB single pole 240 volts 6 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast
S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast
Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply and Fix in repair and replacement of surface mounted Square/Round for LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source with Driver clear diffuser with separate electronic driver with complete accessories all as specified and directed .Make : Philips/ Bajaj / CG/Havells.
Supply and fixing Exhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No. with synthetic enamel paint all specified and directed.Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard without any extra cost to the deptt.
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsible of the contractor.
Taking down and refixing of existing serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. complete all as specified and as directed .
S&F in repair PVC insulated FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt,1.5 Sqmm of 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
S&F in repair metal clad switch socket single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Legrand/ L&T/ Indo Asian
S&F in repair plug top 3 pin 5 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply and Fixing bakelite sheet not less than 3 mm thick of size up to 1 Sqft as per site requirement, including refixing of old/ fixing of new Switch/socket/regulator etc complete all as specified and directed.
Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG
Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos of clamps set, nut, bolts, washers, and incl taking down old unserviceable GI pipe complete all as specified and directed
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 224 here in before but for one light point/fan/bell point controlled by one way switch.
All as per item No. 224 here in before but for one light point controlled by two way switch.
All as per item No. 224 here in before but for one bell point controlled by one bell push.
All as per item No. 224 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 224 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No. 224 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed.
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular switch bell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and fix White cover plate with frame,2/3 module
Supply and fix White cover plate with frame,4 module
Supply and fix White cover plate with frame,8 module
Supply and fix White cover plate with frame,6 module
Supply and fix White cover plate with frame,12 module
S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed Make : Legrand/ Crabtree/ Anchor
S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed Make : Anchor/Havells/L&T
S & F electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T
S & F 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
S & F fan regulator 120W, for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB in repair and replacement of SPN 240 volts 16 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in repair of new PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply and fixing Exhaust fan 250 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor
S & F in replacement 9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
S&F in replacement factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB in repair and replacement of SPN 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 Sqmm 3 core, complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
S&F in repair plug top 3 pin 15 Amps AC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza
S&F in replacement factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directedMake : Indoasian/ Havells/ Legrand.
Supply only TPN, MCB 20 to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etc in soft/loose soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 4 core 10 Sqmm to 3.5 core 25 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 25 Sqmm to 35 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply, installation, testing and commissioning LT Feeder pillar box CPRI Tested of Size 800x600X450 mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation as per site requairment to accomodated to the following. INCOMING (a) MCCB 4 pole 250 Amp 36 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No OUTGOING (a) Through Bus Bar
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, installation, testing and commissioning LT Feeder pillar box CPRI Tested of Size 800x600X450 mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation as per site requairment to accomodated to the following. INCOMING (a) MCCB 4 pole 400 Amp 36 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No OUTGOING (a) Through Bus Bar
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board VTPN, 8 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directedMake : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply and Fixing of 4 feet surface mounted emergency battern type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. complete all as specified and directed. Make : Philips/ Bajaj /CG/Havells.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Havells/ L&T/ Indoasian
S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Dismantling structural steel work including doors, gates etc but excluding framed trusses any description and in any position complete all as specified and directed.
S&F in repairs Pre painted Coloured Galvalume roofing sheet 0.50 mm thick having Zinc aluminium alloy coating double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws etc, including dismantling of old u/s sheets of any description complete all as secified and directed.
S&F in repair 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap in roof, wall etc fixed with L-type or J-type or cranked hook bolts in lieu of screw complete all as specified and directed.
S&F in repairs 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
S&F in Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 as in MS tubes, square bars, angle square bar using various sections such as poles, rafters, purlins, ladders and cleats etc, including dismantling of old one complete all as specified and directed.
S&F in Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, grill, gratings, flat iron, angle iron etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing Fe-290, grade E 165, including dismantling of old one complete all as specified and directed.
M&L for welding in repairs not exceeding 10 Cm length & thickness of metal to be welded not exceeding 6mm comlete all as spcified and directed.
M&L in repairs walling of random rubble, uncoursed, Bangalore type masonry well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed.
Walling of random rubble, uncoursed, Bangalore type masonry (except stone) well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including removal and refixing, built in cement mortar of any description as specified and directed. (Old stones shall be re-used)
S&F in repair concertina coil of 610mm dia (in stretched position) hot dip galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed wire with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touch the bottom barbed wire with the help of hog rings (14 SWG) including removal of old materials etc complete all as specified and directed.
M&L for broken glass coping on top of walls in cement mortar 1:3 including taking down old glass and removing the rubbish to a distance not less than 100 m and deposited where directed complete all as specified and directed. Note : The unit quoted rate deemed to be included for following :- (a) 25mm thick layer of cement mortar glass (of bottle or thick glass) broken to approximately 63mm gauge, shall be firmly embedded at the rate of 10 Kg of glass per square metre of rendered surface, jogged edges of the glass being left projecting. (b) Taking down existing glass from coping. (c) Scaffolding for execution of work and protective measures should be taken by the contractor.
S&F in repair galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc , complete all as specified and directed. (each line wire to be measured)
Restraining and resecuring barbed wire including making good staples etc (each line wire to be measured), complete all as specified and directed.
M&L in repairs 300mmx300mmx25mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry and pointed in white or coloured cement to match the floor and including 20mm thick screed bed in CM 1.4, including removal of old and neccessary demolition, all as specified and directed.
M&L for broken stone boulders hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer and including Demolition of cement Concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed..
M&L in repairs Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 and demolition of old brick work / stone masonry/PCC block built in cement mortar of any description complete all as specified and as directed.
Material and labour for keyed pointing in cement mortar 1:4 to random or polygonal rubble including racking out joints / points in cement mortar to squared rubble masonary coursed or un coursed etc complete, all as specified and directed.
Site clearance by Scraping of grass/wild growth/trees cutting n.exc 0.30m girth etc in soft/loose soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation of manholes, drains, walls and similar works etc, ncluding demolition existing cement concrete, including disposal of demolition material upto 500mtr MD land complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in surface channel of drain, benching in manhole and wall / drain and similar works etc finished even and smooth with using extra cement ncluding demolition existing cement concrete, including disposal of demolition material upto 500mtr MD land complete all as specified and directed. complete all as specified and as directed.
M & L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setting in CM 1:6 work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain faces and Demolition of reinforced cement concrete of any description and in any position and completed all as specified and directed.
M & L mild steel TMT bar 10mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick or concrete surfaces of wall and finished the surface even and smooth without using extra cement with neeru finish to plastering complete all specified and directed.
M&L for preparation of new steel surface and iron work of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed .
M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment including removal of old and necessary demolition complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
M&L for in repairs Providing precast cement concrete louvres and jallies, 35mm thick (measured solid) set in CM 1:4, type B0 1:2:4 , faces are finished smooth including demolition of old mouldings complete all as specified and directed.
S&F Welded steel wire fabric cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mmdia or fixing with with galvanised steel staples supplied and fixed complete to wood or steel members not exceeding 4kg/sqm complete all as specified and directed.
Material and labour for Providing 50mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in concrete in floor of SWT, laid to slope for further treatment with using integral water proofing compound and Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided. Note : WPC shall be measured and paid separately).
Dismantling posts or struts (wood, steel, or RCC) any section, any length not exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in post hole/ foundation filling and for mass concrete and similar works etc all as specified and directed
S&F in MS angle iron Hand rails, fencing of posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
Supply only of chain link fencing MS galvanised sqaure wire mesh of any size, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc all as specified and directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling of old fencing wire mesh of any type etc, complete all as specified and directed.
S&F in repairs MS round bars 10 mm dia and over Fe 290 (Gde - E-165)cut to length bent to shape required including cranking, bending spirally, hooking ends and fixed complete all as specified and directed.
S&F in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, complete all as specified and directed.
Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and included side kerb concrete, included removal and refixing and all as specified and directed .
Note :- An amount of Rs 2,13,092.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
SREE BUILDERS (BID ID -3492831)
devan enterprises (BID ID -3493098)
UNIVERSAL ENGINEERING (BID ID -3495688)
LAKSHMI CONSTRUCTIONS (BID ID -3494725)
A.GOVINDARAJ (BID ID -3492653)
shashi shekar construction (BID ID -3495683)
RAMESH BABU CO (BID ID -3496384)
M/S SRI BALAJI ENTERPRISES (BID ID -3496462)
Maruthi constructions (BID ID -3493999)
RMK PROJECTS (BID ID -3494017)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_828521.xls
BOQ • 0.52 MB
8237GENPAGE.pdf
Tender Documents • 0.46 MB
8237PS.pdf
Additional Documents • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .