Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹19.9 L+₹92,153.65 (4.85%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹19.9 L+₹96,152 (5.07%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹20.3 L+₹1.3 L (6.94%)Rejected-AOC ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹20.5 L+₹1.5 L (8.02%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
Closing Date
5 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ 135 WE
HQ 135 WE C o 56 APO
SPL REPAIR TO BLDG NO P 12 SINGLE JCO LIVING ACCN AT FD WKSP COY EME UNDER GE N AKHNOOR
2021_MES_429144_1
CWE/JA-46/2020-21
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
As per NIT
8 documents required · 8 mandatory
₹500
Yes
Exempted
11 Jun 2021
9 Mar 2021
7 Apr 2021
9 Mar 2021
5 Apr 2021
22 Mar 2021
9 Mar 2021 - 15 Mar 2021
60 days
Amount
Taking down cement plaster on brick or stone walls & ceiling surfaces etc including raking out joints hacking for key scrubbing down with water etc., complete all as specified and directed.
Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement in CM1:4, mixed with water proofing compound @ 3% by weight of cement, complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately).
Supply only Integral water proofing compound, complete all as specified and directed.
Rendering 5 mm thick in cement and sand mortar 1:4 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Fixing 10mm outer dia PVC nozzles by drilling 1/3rd depth of the slab / sunken floor and injection grouting using Dr Fix IT URP 301 of M/s Pidilite Industries or equivlent as in sunken floor/roof slab all as specified and directed as per manufacturers instruction.
Applying two coats of Dr Fix IT fast flex 113 ( coverage area 0.50 Sqm per Kg for two coats) of M/s Pidilite Industries or equivlent as in floor/wall all as per manufacturer's instruction.
Complete removal of existing treatment on walls all as specified.
Preparation of old ( removal of existing treatment shall be paid under item No 08 above ) & new plastered surfaces and applying two coats of OBD over 3mm thick wall care putty all as specified and as directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Preparation of old plastered / old finished surfaces of ceiling and applying two coats of white wash complete all as specified and as directed.
Preparing of new plastered surface and applying two coats cement base paints over a coat of cement primer on walls, complete all as specified and directed.
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of cement concrete (reinforced) in any description and any position otherwise described for (reinforcement cut as reqd to facilitate to demolition) complete all as specified and as directed.
M&L Reinforced Cement concrete (nominal mix) 1:11/2 :3 type A-1, using 20 mm graded stone aggregate as in chajjas, roof projections etc complete all as specified and as directed.
Formwork (rough finished flat surface) to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and directed.
M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring levelling course etc., complete all as specified and directed.
M & L Non skid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces incl 10mm thick screed bed/bedding layers in cement and sand mortar 1:4, complete all as specified and directed.
M & L Non skid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces incl 10mm thick screed bed/bedding layers in cement and sand mortar 1:4, complete all as specified and directed.
M & L Glazed ceramic tiles coloured in vertical surfaces of size 450x350x7mm thick, jointing in neat cement slurry and pointing in colour cement to match including incl 10mm thick backing plaster in cement and sand mortar 1:3, complete all as specified and directed.
20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:3 complete all as specified and as directed by Engineer-in-Charge.
Ditto all as per item No 23 here-in-before but in skirting/dado with 15 CM 1:3 complete.
20 mm thick makrana white marble as in Steps/stair, skirting/dado, border etc, bedded and jointed in cement mortar 1:6 of 20mm thick including pointing in white cement 1:2 using marble dust including cutting and polishing complete all as specified and as directed by Engineer-in-Charge.
20 mm thick makrana white marble as in Steps/stair, skirting/dado etc, bedded and jointed in cement mortar 1:3 of 10mm thick including pointing in white cement 1:2 using marble dust including cutting and polishing complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white ( excluding flushing cistern and pipe) complete fixed in repair, all as specified and as directed.
PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 90 cm long etc, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Vitreous china wash basin, white, flat back, size 550x400mm including pillar tap, waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe and pillar tap etc., fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
Brass chromium plated tubular towel rail 20 mm dia, D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
Stainless steel gratings 100mm bore size fixed with cement motar.
S & F GI water tubes 15mm bore dia medium grade galvanised (ISI Marked) with all fittings and fixed complete to walls and ceiling or laid in floor including taking down existing water tubing, all as specified and directed
S & F GI water tubes 20mm bore dia medium grade galvanised (ISI Marked) with all fittings and fixed complete to walls and ceiling or laid in floor including taking down existing water tubing, all as specified and directed
Stop valves/angle valve, cast copper alloy, chromium plated fancy typescrewed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge
Stop valves/angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 20 mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge
Bib taps, cast copper alloy (chromium plated, fancy type) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
Pillar taps cast copper alloy, fancy type with capstan head, CP, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
S&F of Brass chromium plated shower rose125mm with or without swivel joints fixing to steel pipe fixing in repair.
Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracket guard and railing 60cm long all as specified.
S & F Rotational moulded polyethiene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top triple layered) hoisted and fixed in position including making necessary arrangement for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down of old existing tank, complete all as specified and directed by Enginieer-in-Charge.
S&F mild steel framed work as in grills & framework for water tanks and similar work conforming to Fe-290,grade E-165, complete all as specified
Taking down chowkats or frames n.exc 1..5 Sqm each with shutters (without taking off shutters from the frames) all as specifed and directed.
Taking down chokats or frames with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but n.exc 4 Sqm each , complete all as specified and directed.
Pressed steel frames for doors of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, provding mild steel 6mm dia thresh hold bar and filling hollow of frame of sizes of frame 125 x 60mm, complete all as specified and directed.
PCC 1:3:6 type C-0 using 12.5mm graded stone aggragate as in filling of pressed steel frame complete all as specified and directed.
PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed by Engineer-in-Charge.
35mm thick, IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified & as directed by Engineer-in-Charge.
35 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and as directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube supplying and fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded etc. with suitable PVC sheet beading including hinges etc., complete all as specified and directed.
S&F butt hinges 100 mm medium weight, cold rolled mild steel ISI marked, complete all as specified and directed.
Aluminium alloy, anodised silding door bolt of length 300mm with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast aluminium extruded alloy and fixed, complete all as specified and directed. .
S&F aluminium anodised barrel tower bolt 200 mm, extruded section, complete all as specified and directed.
Aluminium anodised handle extruded section of size 150mm, complete all as specified and directed.
300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
All as per item No 59 here-in-before but without glazing bars.
S&F sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane 3mm thick, complete all as specified and directed.
Figured glass pin head type glazed with oil putty in square n. exc 0.5 Sqm in each pane 4mm thick, complete all as specified and directed. .
S&F for glavanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvnaised wire staples, complete all as specified and directed.
Applying two coat of synthetic enemal paint over & including a coat or red oxide zinc chrome primer over a new steel & iron surfaces of any description not otherwise described over 10cm in width or girth including prepartion of surfaces, complete all as specified and directed.
Applying two coat of synthetic enemal paint to steel surfaces over factory coated a coat of red oxide primer of any description not otherwise described over 10cm in width or girth including prepartion of surfaces, complete all as specified and directed.
Preparation of old painted steel surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint incl removal of old paint complete all as specified and directed.
Preparation of new wooden surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of old treated surfaces of walls (plastered or unplastered) and applying two coats of Apex exterior emulsion paint over a coat of primer as in roof projection / chajjas or pillar projections complete all as specified and directed.
Dismantling of CI pipe of 50/75/100mm bore all as specified.
Fixing only in repair 100 mm dia Cast Iron (spun cast) soil , waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with CI/MS holder bat clamps complete all as spd and directed.
All as description of Srl 70 above but 75mm bore
All as description of Srl 70 above but 50mm bore
S&F 100 mm dia Cast Iron (spun cast) soil, waste and vent pipes in any length with or without ears, with lead joints, laid in trenches or in floors complete all as spd and directed.
All as description of Srl 73 above but 75mm bore
CI bend for 100 mm bore any radius diminishing pieces or tapers (larger bore measured) with CI access door complete as specified.
All as description of Srl 75 above but 75mm bore
Taking down carefully copper/aluminium point wiring (light,fan , llight socket or power socket) complete, incluing fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of wall etc all as directed.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Make of Cables Havells, KEI,Anchor Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M&L for concealed point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn through PVC conduit 20 mm dia, med grade , ISI marked and fixed in concealed surface of wall , ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as specifed and directed by Engr in -charge for the following :-Make of Cables Havells, KEI,Anchor (a) One light/fan/bell point controlled by one way switch
(b) One socket outlet 05 Amps on the same board
(c) One socket outlet 05 Amps on independent board
M&L for concealed point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn into PVC conduit 20 mm dia, medium grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as pecifed and directed by Engr in -charge. ( Note for ser No 4 & 5 - (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one RM). (b) Rate are inclusive cutting chases of bricks and making good to disturbed surfaces when ever required). (c) Proper colour coding should be adopted for phase, neutral and earth .
Supply and fix in replacement of 5 and 15 Amps Switch socket combination, 2 in 1, 6 pin, flush type multi purpose, all as specified. Make Indoasian,Havells,SSK
S& F in replacement of Ceiling rose, 5 Amps surface type 240 volts bakelite three terminal as ordered and directed . Make Indoasian,Havells,SSK
S&F in replacement of Switch piano, single pole one way 5 Amps 240 volt capacity flush type all as specified.Make Indoasian,Havells,SSK
S&F in replacement of 5 pin, 5 Amps Switch Socket combination flush type multi purpose 2 in 1 type (2 pin and 3 pin) and all as specified and directed.Make Indoasian,Havells,SSK
S& F in replacement of Socket out let 5 pin, 5 amp flush type on same board.Make Indoasian,Havells,SSK
S&F in replacement of Fan regulator electronic step type 230 volts suitable for any type of ceiling fan sweep on the existing phenolic laminated sheet etc all as specified and directed.Make Indoasian,Havells,SSK
S&F in replacement of Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, all as specified and directed.Make Indoasian,Havells,SSK
S&F in replacement of Bell push piano switch flush type 5 amp Make Indoasian,Havells,SSK
S&F in replacement of Bell , Ding dong AC, 230 volt, single pole
Supply and fixing VTPN verticle loadline double door distribution box (DB) are fitted with Bus bar neutral link, blanking plates of 4 way with suitable for incomming MCCB 'I/C' frame Make -Indoasian part No- 811888 or its equivalent in Havells ,Legrand, L & T etc.
Supply and fix MCCB TPN 415 volts 16 KA, 63 Amp suitable for TPN vertical loadline DB mentioned at ser No 16 here in before.Make Indoasian,Havells,SSK
Supply & fix in replacement distribution board double door SPN, 12 way powder coated, CRCA steel sheet constructed as per IS:8623 for flush/surface mounting distribution board, factory made and tested complete , protection class IP 36 complete all as specified and directed. Make Indoasian or equivalent in Schnieder,L&T,Legrand
Supply & fix and in repair MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed. Make:- Indoasian cat no-811122 to 811129 and equivalent in Legrand, Havells, schinder.
Supply & fix and in repair MCB SPN 32 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed.Make:- Indoasian cat no-811154 and equivalent in Legrand, Havells, schinder. Note brand for MCBs and DB Boxes shall be matched for srl Item No 15 to 19
Taking down old unserviceable Ceiling fan of any type/size from existing location and deposit in MES store yard and Supply and fix Ceiling fan 1200mm size powered by invertor technology ECM with advance BLDC motor ( to save electricity upto 50 % ) BEE 5 star rated controlled by smart APP. Make Orient electric or equivalent.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmx 600mmx 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45x 45x 45 CM,RCC cover 1:2:4 type B1 of size 45x45x6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. Note : 1. On testing , after completion , if the earth resistance equal or less 2 ohms is not obtained , earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
S & F in replacement of 20 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . (Make- Havells, cat part No ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent in Bajaj/Philips/Crompton Greaves
Taking down old unserviceable Exhaust fan of any type/size from existing location and deposit in MES store yard and Supply and fix exhaust fan single phase metal body, AC 230 Volt, 50 Hz of size 300mm sweep with louvers shouter complete with all accessories including connecting up from ceiling rose to motor all as specified and directed. Make Havells,CG,Luminous
Material & Labour for surface & wall mounted LED tube light fitting 10 W, 2 feet long extruded PVC housing provided for efficient heat dissipation to polycarbonate diffuser & integrated electronic driver with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make- Havells catpart No ENDURALINEARNEOBS10W LED865SPCWH OR equivalent in Philips/ Crompton/ Bajaj
Supply & fix in replacement 10 W LED lamp.Make-Havells Cat No-LHLDERUEML8X010 OR equivalent in Philips/ Crompton/ Bajaj
S & F Wall/Surface mounted LED batten, 20 watt, 230 V, extruded aluminium provided for efficient heat dissipiation with polycarbonate diffuser & integrated electronic driver complete including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make- Havells, cat No ENDURALINEARNEOBS20WLED865SPCWH or equivalent in CG, Philips, Bajaj etc.
Supply and lay XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 16 sqmm 4 core all as specified and directed.
S & F GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts , bolts etc. all as specified.
Excavation in trencehs n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for fdn/ deep for foundation of laying cable etc in any type of soil, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a leven n.exc 1.5 mtr abovee the starting point in any type of soil, complete all as specified and directed.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable, complete all as specified and as directed by Engineer-in-Charge.
M&L sand cushioning in trenches using clean dry river sand for cable cushioning, complete all as specified and as directed by Engineer-in-Charge. Note : Thickness of sand cushioning after punning down will be measured and paid.
M/S KARAN SINGH CONTRACTOR
M/s Joginder Lal Malhotra
M/s Shivam Construction Co
M/S Rajesh Kumar Contractor
M/s Sekinder Paul Sharma
M/S VERMA ENTERPRISES
M/S JEEVAN LAL SHARMA
ASIA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .