Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-Finance KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | ₹33.8 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹34.1 L+₹37,081 (1.10%)Rejected-Finance | ₹34.1 L+₹37,081 (1.10%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹35.2 L+₹1.4 L (4.17%)Rejected-Finance | ₹35.2 L+₹1.4 L (4.17%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹35.3 L+₹1.5 L (4.49%)Rejected-Finance | ₹35.3 L+₹1.5 L (4.49%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹35.6 L+₹1.8 L (5.35%)Rejected-Finance | ₹35.6 L+₹1.8 L (5.35%) | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | ANKIT SHIP REPAIRERS AND SUPPLIERS L7 | PEGASOS ENGINEER TRADERS L1 | SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS L4 | OM SAI ELECTRICALS AND HARDWARES L5 | M/S VERNEKAR AGENCIES L6 | HARSHITA MARINE SERVICES L2 | SRI GURUPRASAD INFRATECH L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for rectifying defects in domestic fluorescent tube/LED light fittings of any type and at any height, including ceiling roses and electric bells, by tightening loose connections, rectifying defects, and testing complete, all as specified and directed. | 200 | Each Job | 80 ₹16,000 | 50 ₹10,000 | 70 ₹14,000 | 80 ₹16,000 | 40 ₹8,000 Lowest | 58 ₹11,600 | 70 ₹14,000 |
| 2.00 | M&L for opening switch mounting plates at normal heights up to 1.5 m, rectifying defects in fittings and fixtures such as switches, bell pushes, fan regulators, sockets, etc., by tightening loose connections, refixing the switch plate, and testing complete, all as directed. | 200 | Each Job | 90 ₹18,000 | 50 ₹10,000 | 70 ₹14,000 | 50 ₹10,000 | 40 ₹8,000 Lowest | 58 ₹11,600 | 70 ₹14,000 |
| 2.01Note for Item Nos. 1 & 2: The unit rate quoted shall be deemed to include labour only for rectifying and making the fittings and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost of labour and materials for the same will be measured and paid for under “S&F in repairs" under relevant items of this schedule hereinafter. In such cases, the above items will not be measured or paid for. | ||||||||||
| 3.00 | Taking down copper/aluminium point wiring (light, fan, socket, or power), complete with fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc.; removing materials to store for safe custody or for taking credit (credit for the above items shall be made separately as per conditions), and making good disturbed surfaces of walls, floors, etc. | 550 | Per point | 130 ₹71,500 | 40 ₹22,000 Lowest | 70 ₹38,500 | 80 ₹44,000 | 80 ₹44,000 | 84 ₹46,200 | 50 ₹27,500 |
| 4.00 | M&L for surface point wiring for one light/fan point controlled by one switch of 1100 volts grade using 1.5 Sq.mm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking, laid in PVC casing and capping of medium grade, including all accessories on walls/ceilings/floors/roofs, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover, including 1.5 Sq.mm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as a continuous earth wire connected to a common earth dolly, all as specified and directed, for the following:- | 80 | Per point | 650 ₹52,000 | 500 ₹40,000 Lowest | 700 ₹56,000 | 700 ₹56,000 | 605 ₹48,400 | 568 ₹45,440 | 600 ₹48,000 |
| 5.00 | All as per Item No.4 above but one 3 pin socket outlet 5 Amp on same board with other switches. | 40 | Per point | 140 ₹5,600 | 300 ₹12,000 | 80 ₹3,200 Lowest | 200 ₹8,000 | 160 ₹6,400 | 106 ₹4,240 | 140 ₹5,600 |
| 6.00 | All as per Item No.4 above but one 3 pin socket outlet 5 Amp on independent board. | 50 | Per point | 680 ₹34,000 | 500 ₹25,000 Lowest | 700 ₹35,000 | 500 ₹25,000 Lowest | 620 ₹31,000 | 568 ₹28,400 | 600 ₹30,000 |
| 7.00 | All as per Item No.4 above but one bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sq.mm size. | 15 | Per point | 680 ₹10,200 | 500 ₹7,500 Lowest | 700 ₹10,500 | 500 ₹7,500 Lowest | 620 ₹9,300 | 568 ₹8,520 | 600 ₹9,000 |
| 8.00 | M&L for point wiring with 2.5 Sq.mm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 2.5 Sq.mm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engineer-in-Charge. | 60 | Per point | 900 ₹54,000 | 550 ₹33,000 Lowest | 1,300 ₹78,000 | 850 ₹51,000 | 1,130 ₹67,800 | 1,035 ₹62,100 | 800 ₹48,000 |
| 9.00 | All as per item No.8 above but with cables 4 Sq.mm for one 3 pin socket outlet 15 Amps on independent board | 45 | Per point | 1,100 ₹49,500 | 700 ₹31,500 Lowest | 1,400 ₹63,000 | 950 ₹42,750 | 1,520 ₹68,400 | 1,236 ₹55,620 | 800 ₹36,000 |
Tender Value
₹45 L
EMD Value
₹9 L
Closing Date
25 Aug 2026, 6:00 pmClosed
GE SEABIRD KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTINGS FIXTURES AND HIGH RISE TOWERS INCLUDING SBS AT SITE A1 OF NAVAL BASE AREA KARWAR
2026_MES_777922_2
8523/E8
Open Tender
Civil Works
Item Rate
240 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
₹9 L
Yes
27 Aug 2026
4 Aug 2026
27 Aug 2026
4 Aug 2026
25 Aug 2026
11 Aug 2026
4 Aug 2026 - 11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for rectifying defects in domestic fluorescent tube/LED light fittings of any type and at any height, including ceiling roses and electric bells, by tightening loose connections, rectifying defects, and testing complete, all as specified and directed. | - | Each Job | 1.25 | - |
| 2 | M&L for opening switch mounting plates at normal heights up to 1.5 m, rectifying defects in fittings and fixtures such as switches, bell pushes, fan regulators, sockets, etc., by tightening loose connections, refixing the switch plate, and testing complete, all as directed. | - | Each Job | - | - |
| 3 | Taking down copper/aluminium point wiring (light, fan, socket, or power), complete with fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc.; removing materials to store for safe custody or for taking credit (credit for the above items shall be made separately as per conditions), and making good disturbed surfaces of walls, floors, etc. | - | Per point | 1 | - |
| 4 | M&L for surface point wiring for one light/fan point controlled by one switch of 1100 volts grade using 1.5 Sq.mm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking, laid in PVC casing and capping of medium grade, including all accessories on walls/ceilings/floors/roofs, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover, including 1.5 Sq.mm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as a continuous earth wire connected to a common earth dolly, all as specified and directed, for the following:- | - | Per point | 2 | - |
| 5 | All as per Item No.4 above but one 3 pin socket outlet 5 Amp on same board with other switches. | - | Per point | 3 | - |
| 6 | All as per Item No.4 above but one 3 pin socket outlet 5 Amp on independent board. | - | Per point | 4 | - |
| 7 | All as per Item No.4 above but one bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sq.mm size. | - | Per point | 5 | - |
| 8 | M&L for point wiring with 2.5 Sq.mm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 2.5 Sq.mm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engineer-in-Charge. | - | Per point | 6 | - |
| 9 | All as per item No.8 above but with cables 4 Sq.mm for one 3 pin socket outlet 15 Amps on independent board | - | Per point | 7 | - |
| 10 | M&L for point wiring for one light/fan point controlled by one switch with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engineer-in-Charge. | - | Per point | 8 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tender8523.pdf
Tender Documents • 0.97 MB
BOQ_876945.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .