Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 677A DIAMOND HARBAR ROAD HINDUSTAN PARK BEHALA KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹7.5 L+₹1,320 (0.18%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹7.5 L+₹1,458 (0.20%)Rejected-Finance BANSHBARI MALDA | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹14,944
Closing Date
21 Sept 2022, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
E.I Work for installation of AC machine along with necessary Electrical works at Component Separation Room in Blood Bank of District Hospital, Bishnupur Health District
2022_WBPWD_404109_1
WBPWDTE/EE/BED/NIQ_85/Q of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹14,944
22 Nov 2022
9 Sept 2022
23 Sept 2022
9 Sept 2022
21 Sept 2022
9 Sept 2022
Amount
SUB-HEAD 1 -- SITC OF EI Work Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 19 mm dia 3 mm thick [ 3 (a)/ E- 2 ]
25mm dia 3 mm thick [ 4 (a)/ E- 2 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC
2x(4 sqmm)+1x (2.5 sqmm)
S & F 240V 21A OLP - 30 Electrronic starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetion as per direction of EIC for AC Machines
S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S.
S/F railway type water guard protection G I loop box size 10x8x6 inch & both side having 2 no.s nuts bolt for earth protection & having a locking arrengement & inside of box and including fixing of 32 A FP MCB Isolator.( for 3 phase A.C machine control outdoor side)
S/F (2+4) 4 way double door DB box(Encloser: 607700) with FP 32A 1 no. Isolator (make-Legrand) as per EIC.
Timer Panel:Supplying and fixing (2+12)way Legrand DB enclosure for housing the following A) One no.single dial digital timer (Legrand) B)One no. FP pole, conctractor 40 AMP,(LEGRAND) C) One no. FP 63A MCB (Legrand) D) One no. auto/manual Toggel Switch and other required material The complete arrangement must be wiring by PVC insulated Cu wire as per GS
S/F of 10 way Legrand double door SPN DB (607721) with acrylic cover complete with one 40A Dp isolator, One no.single dial digital timer (Legrand), one 25A DP contactor, one indicator(004484) and one outgoing MCB (6-32A) with interconnection by cupper wire complete as per direction of EIC.
Dismantling of Split AC machines from the existing position and reinstalling them to desired places as per the authority concern as per direction of EIC.
S&D of Recessed mounting square type 18W LED light Cat No LSCSM-18W-CDL Make Crompton/Havells/Phillips
SUB-HEAD 2 -- SITC OF AC MACHINE Supply & Delivery of Ceiling suspended ductable type split airconditioners having Microprocessor based control system and the following specification. Capacity-5.5 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity -66000 BTU/Hr No. of IDU-1 No Air-flow/IDU-2200CFM No of ODU- 1 Nos Compressor -1 No Scroll Compressor Refrigerent -R410A/R407C Condenser & Cooling Coil:Copper coil Power Supply :415v, 50Hz,3 Ph AC (with applicable tolarance) [ Make-O General/Mitsubishi Electric/Hitachi/ DIAKIN]
Installation, Testing & Commissioning of the above Air Conditioners by making scaffolding arrangement as per site condition, supply of necessary refrigerent, connecting control & power cabling & other necessary materials to complete the job For 8.5 TR Ductable Units.
7/8" (22.2 mm.) dia (Hard drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation.
Supply & Fixing Pipe Insulation in suction line with 9mm nitrile rubber tube for 5.0 TR Concealed split Ac machine(Make:Accoroflex/Suprime)
6 core x 1.5 mm² Round PVC insulated copper cable (Make-Polycab/Haavells/ Gloster/Finolex /RR Kable/KEI).
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal (Make-Tata steel/Sail/Jindal) rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, venes, hangers, support etc as per approved drawings and specification of following sheet complete as required For 24 SWG
For 22 SWG
Duct tharmal insulation by supplying and fixing of following thickness dully laminated aluminium foil of mat finish closed cell Nitrile rubber (Class 'O' ) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 9 mm
Duct Acoustic insulation by supplying and fixing of following thickness Open cell Nitrile rubber (Class 'O' ) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 10 mm
Supply & Fixing of Powder Coated extruded aluminium Supply Air Grills with aluminium volume controll dampers complete as per specification.
Supply & Fixing of Powder Coated extruded aluminium Return Air Grills with louvers but without volume controll dampers complete as per specification.
Supply & laying PVC Drain Pipe 25mm dia with 6mm thick Nitrile Rubber Insulation (Make: Suprime/Oriplast)
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame for installation of outdoor unit of 8.5 Tr Ductable Split AC & High wall split incl. drilling holes in each channel, cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm as per direction of E.I.C.
Supply & Fixing of Fusiable Link Fire Damper,Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995),with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed
Supply and fixing of Opposed blade GI Non returnDuct Damper. (Make - Ravistar / Caryaire / Dynacraft).
Supply, cutting & fixing drop ceiling made of gypsum & E-board (3 mm thick) incl. Al. channel & complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete to cover the indoor units of concealed split unit incl. painting the board as per direction of EIC.
Charges for trap door with 3 mm thick ACP board (MAKE- Aludecor/ Urobond or others reputed make) complete with inkages, levers, fitings.support all accessories for IDU maintenance ad per direction of EIC.
Supply,Installation, Testing & Commissioning of 1.5 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32 of BEE 3 Star rated. Full Copper Condenser and Evaporator (Make- OGeneral/Hitachi/Daikin/As per approved by EIC) 1.5 TR AC machine(Cat No-ASGG18CKTA-B /AOGG18CKTA-B)
Supply & Laying Extra Add-on items- 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 3 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for A.C. Machine. and Supply & laying PVC Drain Pipe 19mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C.
Control copper Cabling from ODU Unit to IDU unit of Split AC 3 Core 2.5sq. mm. Communication Cable
Supply & fixing of Powder coated MS ODU Bracket
SKY DECORATIONS PRIVATE LIMITED
M/S KUNDU CONSTRUCTION
technical_793713.pdf
PDF • 0.19 MB
techsummary_793713.pdf
PDF • 0.19 MB
finance_793713.pdf
PDF • 0.19 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_793713.pdf
PDF • 0.20 MB
85Q.pdf
PDF • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .