Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹6.9 L
EMD Value
₹13,880
Closing Date
30 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Col Saikat De
CWE (Navy) Vasco
CONSULTANCY SERVICES FOR STRUCTURAL AUDIT AND LOAD TESTING OF NULLAH BRIDGE INS VAJRAKOSH AT NAVAL BASE KARWAR
2026_MES_798024_1
86170/E8
Open Tender
Civil Works
Item Rate
60 days
karwar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SB Karwar
₹13,880
Yes
9 Nov 2026
9 Nov 2026
2 Dec 2026
9 Nov 2026
30 Nov 2026
23 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | VISUAL SURVEY
Visual inspection for surface damages, damage classification. The visual inspection shall largely cover areas of high distress, corrosion, moisture, leakage, abnormal variations in structure, algae and fungus growth, efflorescence, etc. Visual inspection would be documented in the form of worksheets, photographic records, and distress over drawings. Simple tools and instruments like camera with flash light, magnifying glass, binoculars, chisel and hammer, etc shall be used for measuring the distresses as per site requirement. | 1 | Nos | 53 | ₹53 |
| 2 | REBOUND HAMMER
For determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 13311 (Part-2)-1992, ASTM C 805-02, BS 6089:1981 and BS 1881: Part 202, BS-EN:13791, also establishing correlation chart between rebound hammer and other confirmatory test for having estimated in-situ strength of concrete if required. In absence of the confirmatory test strength data will be generated on the basis of empirical formula (obtained from the calibration chart) but those results will have 25% variation as per IS 13311 Part 2 1992 | 20 | Nos | 10 | ₹200 |
| 3 | ULTRA SONIC PULSE VELOCITY
for ascertaining the quality of concrete, uniformity of concrete in terms of soundness and density of concrete as per IS 13311 (Part-1)-1992, ASTM: C597-83, BS 6089: 1981 and BS 1881: Part 203 and BS EN: 13791; also establishing correlation chart between USPV and other confirmatory test for having estimated in- situ strength of concrete if required | 20 | Nos | 11 | ₹220 |
| 4 | CORE EXTRACTION TESTING
Extracting the concrete core samples following the codal provisions; and evaluating the properties (fck value, grade of concrete) in the laboratory from the core samples selected. IS 456:2000; IS 516:1959, IS 1199:2002; ASTM C-42, without encountering any steel reinforcement from the RCC members covered under the study at specified locations by site in-charge with portable power driven core cutting equipment | 6 | Nos | - | - |
| 5 | HALF CELL
Measuring the half-cell / surface potentials at selected locations on RCC members of the structures covered under the study to understand the extent of reinforcement corrosion in terms of probable risk of corrosion of steel bar as per ASTM C876 The rate shall include surface preparation, moistening concrete surface | 10 | Nos | 10 | ₹100 |
| 6 | COVER CARBONATION TEST
Measurement of carbonation depth by phenolphthalein spray test at selected locations (drilled powder sample or concrete core sample as per site condition) on RCC members of the structures covered under the study to see the depth of carbonation as per BS EN 14630:2006, BS EN 13295:2004. Cover depth is also measured at the same location to know the ration of Carbonation depth | 10 | Nos. | 10 | ₹100 |
| 7 | REPORT INTERPRETATION AND RECOMMENDATION
Preparing and submitting comprehensive report consisting of findings from visual inspection, test data, interpretation of results, conclusions and final recommendations along with sketch indicating the location of the test. Recommendation part does not include the repair scheme/DPR or BOQ related to the project. Evaluation and presentation on recommendations/suggestions for approval measures of UNESCO/ICM/EAG final submission. The HD quality site photographs and Video shall be provided to employer in a good quality of CD/DVD/USB hard disk along with softcopy but any data generated from the patented software can't be edited so those files can't be provided in the editable format.
VETTING OF STRUCTURAL AUDIT REPORT : The structural audit report shall be vetted only through the National Institute of Technology (NIT) or Indian Institute of Technology (IIT) after completion of all inspections, testing, surveys, and preparation of the draft report.
The complete cost towards vetting, review, modifications, observations compliance, liasoning, travelling, and final approval from IIT/NIT shall be borne by the agency and shall be deemed to be included in the quoted rates. No extra payment shall be admissible on this account. | 1 | Nos | - | - |
| 8 | LOAD TESTING
Testing Live Load and Dead Load of the structure and its impact along with Report
Note:The consultant shall submit complete as built drawings of the bridge, including plans, elevations, structral details and all other requisite details, to faciliate planning and execution of any future strengthening/modification works | 1 | Nos | 1 | ₹1 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
86170Tender.pdf
Tender Documents • 0.63 MB
BOQ_895221.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .