| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.7 LAccepted-AOC HIMACHAL PRADESH | SHIMLA | HIMACHAL PRADESH | 171002 | L-1 | Accepted-AOC Awarded to Lowest bidder | |
| 2 | L-2₹15.4 L+₹69,070.85 (4.71%)Rejected-Finance VILLAGE AND POST OFFICE JEORI TEHSIL RAMPUR DISTT SHIMLA H P | JEORI | SHIMLA | HIMACHAL PRADESH | L-2 | Rejected-Finance Higher Amount | |
| 3 | L-3₹15.8 L+₹1.2 L (7.85%)Rejected-Finance VILLAGE DHARMEHAR P O JHATINGRI TEHSIL PADHAR DISTT MANDI H P | L-3 | Rejected-Finance Higher Amount | |
| 4 | L-4₹16.3 L+₹1.6 L (11.2%)Rejected-Finance | L-4 | Rejected-Finance Higher Amount | |
| 5 | L-5₹17.2 L+₹2.5 L (16.9%)Rejected-Finance 39 1 LASWAIKHAD PO BARYARA TEHSIL KOTLI DISTRICT MANDI PIN CODE 175052 | MANDI | HIMACHAL PRADESH | 175052 | L-5 | Rejected-Finance Higher Amount |
Tender Value
₹25.9 L
EMD Value
₹46,282
Closing Date
30 Dec 2023, 11:00 amClosed
Executive Engineer
Executive Engineer JSV Division Nalagarh HP
Sub Head Repair of Pump house cum attendant quarter of 1st stage Construction of Sector Storage Tank at Node No 18 52 78 Laying jointing and testing of GMS pipe of various dia in distribution system internal electrical wiring of pump house 1st and 2n
2023_HPIPH_82965_1
16216-56 dated 21-12-2023
Open Tender
Civil Works
Item Rate
180 days
Ramshehar
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
₹46,282
Yes
19 Jan 2024
21 Dec 2023
30 Dec 2023
21 Dec 2023
30 Dec 2023
21 Dec 2023
Amount
Excavation in foundation trenches upto all depths in all classification of earth work such as pick work,jumper work, saturated soil including bailing and pumping out water,blasting soft/hard rockor chiselling soft/hard rock where blasting is prohibited.In all lifts including trimming and dressing of sides,levelling of beds to correct grade i/c shoring,strutting,planking timbering and dewatering wherever required,stacking the usable and un-useable material / soil separately and after laying, jointing of pipes returning the useable soil in trenches in trenches in 15 cm (fifteen centimeters) layers including consolidating of each deposited layer by ramming and watering and disposing of all surplus excavated soil/ un useable materials as directed within all leads & lifts including restoration of un-metalled surfaces to its original condition and including cost of diverson for traffic night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc.complete in all respect with in all leads & lifts as per the direction of the Engineer-in-charge.
Excavation in drain and channels etc. earth work for pipes upto all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is probihited in all lifts including jungle clearence wherever required, trimming & dressing of sides, levelling of beds to correct grade including shoring/struting, planking , timbering & dewatering wherever required stacking the useable/unuseable material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/ unuseable material as directed with in all leads & lifts including restoration of un-metalled surfaces to its original condition & including cost of diversion for traffic, right signals, fixing caution boards, crossing over trenches for acess to houses, fencing etc. complete in all respect with in all leads and lifts and as per direction of the Engineer-in-charge at site of work.
Demolition above G.L. upto floor two level including stacking of serviceable materials and disposal of unserviceable materials within all lead and lifts & including cutting the necessary reinforcement and stacking of serviceable material and separating out from R.C.C. /R.B. works:- R.C.C. work. complete in all respect with in all leads & lifts as per the direction of the Engineer-in-charge.
Providing and laying cement concrete of design mix M-30 but not leaner than cc 1:1.5:3 (1Cement :1.5 Sand: 3 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in walls any thickness but not less than 0.1m thickness )attached pillasters,buttreses,plinth and level upto floor two level including entire carriage of materials with in all leads and lifts.
Flat surfaces such as suspended floors, roofs, beams and giders.
Vertical surfaces such as walls (any thickness not less than 0.1m thickness)partitions and the like including
Providing and laying cement concrete 1:4:8(Icement:4sand:8 graded stone aggregate 40mm nominal size)in foundation and plinth complete in all respect with in all leads and lifts and as per direction of the Engineer-in-charge at site of work.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring,shuttering,struting and propping etc with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu,reinforced concrete and plain concrete work in flat surface such as soffits of suspended floor,roofs,landing and the like including carriage of materials with in all leads and lifts.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.upto 200 mm thickness including carriage of material in all leads & lifts.
Vertical surfaces such as wall (any thick.) partitions & the like i/c attached pillasters, buttresses,plinth & string courses & the like.
Providing and laying cement concrete work 1:2:4 of design mix M-20 but not leaner than cc (Icement:2sand: 4 graded stone aggregate 20 mm nominalsize)and curing complete excluding cost of work and reinforcement for reinforced concrete work in :- Suspended floor roofs, landing and shelves and their support balconies, beam girderes bressumers and cantiliver upto floor two level.
Providing and Placing Tor steel reinforcement for RCC work i/c bending,binding and placing in possition complete including bending wire upto floor all level including carriage of material in all leads & lifts
Laying and jointing GMS scour pipe 100 mm dia (Light grade) including entire carriage of materials with in all leads and lifts as directed by the Engineer-in-Charge.
Prov. & fixing CI Man hole cover with frame having frames size of 500 mm internal dia. (Medium duty) The weight of cover & frame should not be less than 116 kg
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly) 80 mm dia
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb lock jamb,beed and if reuired angle threshold of mild steel angle of section 50X25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical means,adjustable lugs with split end tails to each jamb including steel but things 2.5 mm thick with guards,lock strike plate and shock absorber as specified and applying a coat of approved steel primer after pretreetment of the surface in all leads and lifts and as directed by Engineer-in-Charge.
Profile-"A".
Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint.using flat 30mm x6mm for diagonal braces and control cross/pieces including entire carriage of materials in all leads and lifts as per the direction of the Enginner-in-Charge.
40mm thick cement concrete flooring 1:2:4(1 cement:2sand:4graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement including carriage of materials with in all leads and lifts.as per the direction of the Enginner-in-Charge.
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel paint other than white complete in all respect in all leads and lifts as per the direction of the Engineer - in - Charge.
Laying,jointing and testing in trenches galvanised mild steel tube screwed and socketed of following dia and grade confirming to BIS 1239 ( with latest ammendment upto date) as per classification of pipe as specified below. The laying of pipe shall confirm to BIS 5822 (With latest ammendment upto date) providing and fixing pipe fittings such as G.I. Union ,bends,tees,sockets etc. all kind of specials such as bends of all degrees to made from parent tube, short pieces, tail pieces all made from parent tube within all leads & lifts. (earth work in trenches to be measured and paid for separately) including carriage of G.I. pipes as per direction & to the entire aatisfaction of Engineer-in-charge.
20mm dia(Light Grade)
25mm dia(Light Grade)
32mm dia(Light Grade)
Providing and fixing peet valve of following dia complete in all respect. The valves shall be of relevant BIS code including all kind of lead & lifts, carriage to the entire aatisfaction of Engineer-in-charge.
20 mm dia.
25mm dia.
32 mm dia.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group "C"
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials within all leads and lifts.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials upto all leads and lifts.
Wiring for circuit/sub-main with 4x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 2 No.2.5 Sq.mm.(4X2.5+2X2.5)HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials upto all leads and lifts.
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch,connections, painting etc. as required including carriage of materials upto all leads and lifts.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required "A" single pole including carriage of material within all leads and lifts.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required including carriage of material within all leads and lifts.Double pole Category "B" 63 Amp.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset,neutral link, earth bar, din-bar, detachable gland plate,blanking plate, cable, identification labels interconnections,phosphatized and powder painted, including earthing etc. as required including carriage of material within all leads and lifts.Single door-8 way.
Providing,installing,testing and commissioning of 2x36 Watt CFL street light Category "A" including wiring with 1.5 sq.mm. PVC insulated copper conductor single core cable as required complete in all respect including carriage of material within all leads and lifts.
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. Category "A".
Providing,installing,testing and commissioning of 1x36 Watt FTL(T-8) shock proof slim (Category "A") including wiring with 1.5 sq.mm. PVC insulated copper conductor single core cable as required complete in all respect including carriage of material within all leads and lifts.
NARAYAN SINGH
SUKH RAM
HARISH SHARMA
DEEPAK THAKUR
SURAT RAM D CLASS GOVT CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .