Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.1 L+₹32,433.50 (2.05%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.5 L+₹1.7 L (10.7%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹18.0 L+₹2.2 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹20.7 L+₹4.9 L (31.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20.8 L
EMD Value
₹41,560
Closing Date
14 Jan 2020, 6:00 pmClosed
GE South Pathankot
GE South Pathankot
Provn of high mast security pole fitted with 8 Nos 200W led flood LT fittings for each pole at unit lines of 9 FOD and certain Revenue and Minor works under AGE E/M Pathankot of GE (South) Pathankot.
2019_MES_307240_1
GES/PKT/T-50/2019-20
Open Tender
Civil Works
Item Rate
180 days
Kandrori
Refer tender documents and NIT
9 documents required · 9 mandatory
₹500
GE South Pathankot
₹41,560
Yes
25 Feb 2020
17 Dec 2019
15 Jan 2020
17 Dec 2019
14 Jan 2020
1 Jan 2020
17 Dec 2019 - 23 Dec 2019
Amount
Supply, erect, test and commissioning of minimum 16 metre high mast system with its accessories. Mast shall be in two sections, hot dip galvanized and suitable for wind velocity 50 M/ sec as per IS 875 part 3. It shall consist of GI lantern carriage suitable for 8 luminaires symmetrically & their control gear boxes and lighting finial, double drum winch with both motor and manual operation, suspension system with SS wire rope 6mm dia (7/19 construction), trailing cable of flexible copper conductor cable 5 core 2.5sq.mm (minimum), torque limiter adjustable type, lightening arrestor & 01 No. aviation obstruction light (LED type). The mast shall have an integral power tool with reversible option installed inside the base compartment for its operation complete all as specified and as directed. Note: The rate quoted shall be inclusive of the following: (a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set (b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings - 01 Job
(c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer's design of foundation drawing as approved by GE. (d) Erection and commissioning of the high mast with the help of suitable equipment. (e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour. (f) Provision of Aviation obstruction light LED type. (g) Provision of lightening arrestor spike. (g) The Contractor shall submit OEM technical specification of High mast for approval of Acceptance Officer before placing order. (h) The Contractor shall submit warranty & TC before claiming payments.
Note : (i) The earth work in any strata i.e. excavation,return filling, removal , RCC foundation with foundation bolts manufactured from special steel with nuts, wahsers, anchor plate and template deemed to be included in item rate.(ii) The M/L for LED flood light fittings & Control panel required will be measured and paid separately under relevant Schedule items.
Supply and fix LED flood light fitting 200 Watts (with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 66 and external SPD of capacity 10 KV in addition to inbuilt SPD of electronic driver , having Pressure die cast housing with high efficient output emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including MS Clamps of suitable size for fixing on High Mast /Pole complete all as specified and as directed.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes 25 sqmm 4 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoure35 sqmm 3.5 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoure 10 sqmm 2 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays complete all as specified and as directed.
All as per item No 06 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs complete all as specified and as directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid complete all as specified and as directed.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and as directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and as directed.
Supply and fix LED flood light fitting 120 Watts (with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 66 and external S PD of capacity 10 KV in addition to inbuilt SPD of electronic driver , having Pressure die cast housing with high efficient output emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including MS Clamps of suitable size for fixing on High Mast /Pole complete all as specified and as directed.
Notes for Item No.2, 14, 43 to 47 : (i) Driver Efficacy – more than 85% ( constrant current driver).(ii) Driver Type – Potted (iii) THD - < 10% (iv) Led Driver Current – less than 750 mA (v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 10 KV (vii) Working Humidity - 10% to 90% RH (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply and installed Deep Freezer, double door, glass top electric driven (single phase 230 volt 50 Hz),minimum capacity 300 litres 5 star rated frost free with CFC free refrigerant, energy efficient complete all as specified and directed.
M&L for power point wiring with PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 2.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting complete all as specified and as directed.
M&L for switch socket combination 15 amps 240 volts with polycarbonate body complete all as specified and as directed.
Supply, installation, testing and comissioning self contained drinking water cooler Stainless steel electric driven single phase with (non CFC refrigerant) energy efficient compressor,cooling cap 40 Ltr,storage Cap 80 Ltr with stainless steel tank and anti corrosive blue film. Note: The rate inclusive of (i) PCC foundation for Watercooler (ii) Plug and socket including 2.5 sqmm submain wiring from DB to plug and socket complete all as specified and directed. (iii) Necessary incl. water connection/valves and drain etc complete.
M & L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 4.0 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. “ Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
Supply and installation,testing of Water heater (geyser), electric ,suitable for operation on 230 V 50 Hz AC, storage type of capacity 25 Ltrs, BEE star rated, 5 star rating, suitable for minimum 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body including all accessories complete all as specified and as directed.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Supply & Fix sheet metal enclosure with DB's ( grouted in walls) single pole and neutral double door type for MCB's 08 ways with 200 Amps 240 volts rated bus bar complete all as specified and directed.
M&L 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' series complete all as specified and as directed.
S&F MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' series complete all as specified and as directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked complete all as specified and as directed.
S&F angle valve, brass CP screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm dia of ISI Marked complete all as specified and as directed.
S&F bib tap long body brass CP screwed down high pressure, with or without lettered Hot or Cold of size 15mm dia of ISI Marked complete all as specified and as directed.
Supply , install , testing and commissioning of desert cooler electric driven, single phase of approx minimum size 600 x 810 x 635 mm made out of 2mm thick GI sheet for body, with water tank of capacity 50 Ltr and with front grills and side direction grills, suitable for minimum air Delivery- 4000 Cum/hr,approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of minimum capacity 40 watt, 1300 RPM suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch for fan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including stand of minimum height 900 mm made out 25mmx25mmx3mm MS angle iron , duly coated with weather proof paint of black colour all as specified and directed. Note : The rate inclusive of 3 core 2.5 Sqmm PVC sheathed and insulated flexible copper cable chord of 2 mtr long with 3 pin 5 Amp top plug for power supply complete all as specified.
M&L for point wiring with PVC insulated FRLS copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated FRLS copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). a) One light point or one fan point or bell point controlled by one switch SP one way 230 Volts. Note : In ceiling portion surface conduit wiring shall be carried out
all as per item No 32 above but One 3 pin socket outlet, 5 amps,independent board complete all as specified and as directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and as directed.
M&L for socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and as directed.
M&L for ceiling rose 2-3 terminal size 65x20mm complete all as specified and as directed.
M&L for Cutting hole for exhaust fan of size 400/300/250 mm including masonary work complete all as specified and as directed
Supply & Fix Exhaust fan AC sinlge phase 230/240 volts of size 250 mm sweep steel body with louvers including connecting to ceiling rose complete all as specified and directed.
Supply & Fix Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvers including connecting to ceiling rose complete all as specified and directed.
S&F Ventilation fan AC Single phase 230/240Volts of Size 250 mm sweep plastic boby with louvers including connecting to ceiling rose complete all as specified and as directed.
S & F distribution board iron clad, double door with IP-54, 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.Note : (i) DB shall be minimum IP-54 with mechanical strength IK-09 and manufacturer/OEM certificate for the same to be submitted. (ii) The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.(v) Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment”
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2300 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 25 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl GI bracket and necessary clamps etc complete and testing on completion complete all as specified and as directed.
Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl GI bracket and necessary clamps etc complete and testing on completion complete all as specified and as directed.
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion complete all as specified and as directed.
Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion complete all as specified and as directed.
Supply & fix decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) complete all as specified and as directed. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and as directed.
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as specified and as directed.
Supplying and fixing service cable size 4 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as specified and as directed.
Supply & Fix wall mounted fan AC sinlge phase 230/240 volts of size 400 mm sweep PVC/Plastic body ISI marked with all accessories complete including connecting to ceiling rose complete all as specified and as directed.
Supply & Fix inverter type wall mounted with 4 hours backup fan AC single phase 230/240 volts of size 400 mm sweep PVC/Plastic body ISI marked with all accessories complete including connecting to ceiling rose complete all as specified and as directed.
Supply, Install, Testing and Commissioning of ‘SOLAR WATERSYSTEM' (Evacuated Tube Collector) based on direct transferring of heat of capacity 300 LPD with power backup complete including submain wiring 4 sqmm with connected DBs and MCBs complete all as specified and directed. Water Heating system at 600 C (Average) temperature comprising of : (a) Flat Plate collector(as per BIS 12933),01 No for each system of 300LPD(b) Stand for the collectors (c) Hot water tank (SS-304)TIG welded with PUF insulation & Stainless Steel Outer cladding (d) Stand for hot water Tank (e) Hydraulic steam hose pipe with check nut (f) Air vent 1 No for each system Note : (a) The Contractor shall submit OEM technical specification of High mast for approval of Acceptance Officer before placing order .(b) The rate quoted deemed to be inclusive of angle iron supports of solar stand
S&F triple layered Rotational moulded polyethylene water storage tanks of capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. Note : The angle iron supports of staging of PVC tank will be measured and paid separately under relevant Schedule items.
S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 20 mm bore complete all as specified and as directed.
S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 25 mm bore complete all as specified and as directed.
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe of following sizes :
20 mm dia bore
25 mm dia bore
Supply and lay in trenches / on roof / on wall / steel water tubing galvanised medium grade (cold water piping)with all fittings of following sizes :
20 mm dia bore
25 mm dia bore
15 mm dia bore
S&F brass ball valves high pressure with polythene float and flynut complete, screwed for iron pipe or ferrule at any position and description of 25 mm bore size all as specified and directed by Engr- in - charge.
M&L for PCC 1:2:4 type B1 20mm graded stone grade aggregate for the bottom basement layer of the solar stands including necessary form work complete all as specified and as directed.
M & L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. “ Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
Supply, fabricate and fix mild steel work as in cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint complete all as specified and as directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
commercial traders
SATISH AND CO
KULBHUSHAN AGGARWAL
M/S Vijay Punj Constructions
M/S BALWINDER SINGH
Ashoka Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .