| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹16.2 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹18.4 LRejected-Finance | ₹18.4 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹18.6 LRejected-Finance PASCHIM KHILKAPUR G P BARASAT BLOCK 1 | PASCHIM BARDHAMAN | WEST BENGAL | 713148 | ₹18.6 L | L3 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | MODERN ELECTRIC L3 | BANERJEE CONSTRUCTION AND CO L2 | M/S R. K. ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | PART-A (A.C WORK)
Supply Installation, Testing & Commissioning of- 5.5 TR Capacitiy Air cooled Ducted Split Air-Conditioner Unit. [Rated Cooling Capacity-90,000 BTU/HR-(min)] The Outdoor unit shall have 2 set R-410 A duty hermetic sealed scroll compressors of AC/ 3 ph/415 Volt power supply, 3 row deep Condenser Coil having internally grooved copper tube & aluminum fins, Propeller Fan with 220 V motor, control, gauges & accessories. Ceiling Suspended Indoor unit having air flow rate-3000 CFM (min) complete with 3 row deep evaporator coil shall have internally grooved copper tube & aluminum fins, DIDW centrifugal blower with direct drive motor, synthetic washable 10 micron filters, refrigerant controller, valves & gauges like multi port distributor, thermostatic expansion valves, electronic thermostat, refrigerant valves & all other accessories. The unit shall be provided with microprocessor based control panel with corded remote controller. (Make-Hitachi/Mitsubishi Heavy/ Daikin/Voltas) | 3 | Nos. | 1,89,500 ₹5.7 L | 1,89,500 ₹5.7 L | 2,20,000 ₹6.6 L |
| 2.00 | Supply Installation, Testing & Commissioning of-2.0 TR Capacity Air Cooled Concealed Split Air-Conditioner Unit. [Rated Cooling Capacity-24,000 BTU/HR-(min)] The Outdoor unit shall have single R-410 A duty hermetic sealed rotary compressor of AC/220 Volt power supply, 2/3 row deep Condenser Coil having internally grooved copper tube & aluminum fins, Propeller Fan with 220 V motor, control, gauges & accessories. Ceiling Suspended Indoor unit having free air flow rate-800 CFM (min) complete with 4 row evaporator coil shall have internally grooved copper tube & aluminum fins, DIDW centrifugal blower with single phase motor synthetic washable 10 micron filters, refrigerant controller, valves & gauges like multi port distributor, thermostatic expansion valves, electronic thermostat, refrigerant valves & all other accessories. (Make-Hitachi/Mitsubishi Heavy/ Daikin/Voltas) | 1 | Nos. | 67,000 ₹67,000 | 67,000 ₹67,000 | 80,000 ₹80,000 |
| 3.00 | Supply, Installation, Laying, fitting, brazing jointing including leak testing of Hard Drawn Copper Refrigerant Piping Work In between each set of above AC Outdoor & Indoor units complete with necessary bend, elbow, tee & other fittings, GI bracket/ hanger supports etc. entire pipe line shall be duly insulated with 12/9 mm thick aluminum foil faced closed cell nitrile foam tube sleeve, each joint to be bonded with recomended adhesive & covered with self adhesive aluminum tape at 15" interval 1
1/2"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc. | 45 | Mtr. | 200 ₹9,000 | 195 ₹8,775 | 80 ₹3,600 |
| 3.10 | 7/8"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc. | 45 | Mtr. | 648 ₹29,160 | 632 ₹28,440 | 75 ₹3,375 |
| 3.20 | 5/8"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc. | 10 | Mtr. | 466 ₹4,660 | 456 ₹4,560 | 80 ₹800 |
| 3.30 | 1/4"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc. | 10 | Mtr. | 280 ₹2,800 | 280 ₹2,800 | 72 ₹720 |
| 4.00 | Control Cabling from ODU Unit to IDU unit of Ductable Split AC Communication Cable along with necessary sockets and glands.[NS]
4 Core 2.5 Sqmm unarmoured Copper cable | 10 | Mtr. | 162 ₹1,620 | 161 ₹1,610 | 100 ₹1,000 |
| 5.00 | Supply & Laying Drain Water piping work out of PVC/HDPE hard pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(Mk. Oriplast /Supreme) [NS] | 100 | Mtr. | 125 ₹12,500 | 120 ₹12,000 | 70 ₹7,000 |
| 6.00 | S& F of GI AC Tray underneath the indoor units of AC machines.
2.0 Tr | 1 | Nos. | 2,900 ₹2,900 | 2,800 ₹2,800 | 6,500 ₹6,500 |
| 6.10 | 5.5 Tr | 3 | Nos. | 4,700 ₹14,100 | 4,600 ₹13,800 | 7,500 ₹22,500 |
Tender Value
₹19.9 L
EMD Value
₹39,800
Closing Date
7 Jan 2026, 1:00 pmClosed
EEI,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
SITC of AC machine including requisite E. I work at the 1st Floor of Accounts section of Administrative building RGKMCH.I) AC Installation Work. II) EI Work.
2025_WBPWD_922589_1
WBPWD/EE/KNHED/e-NIQ-48/25-26
Open Tender
ELECTRICAL WORKS ORG
45 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹39,800
Office of the EE, KNHED,PW Dte
23 Apr 2026
13 Oct 2025
9 Jan 2026
13 Oct 2025
7 Jan 2026
30 Oct 2025
29 Oct 2025
Amount
PART-A (A.C WORK) Supply Installation, Testing & Commissioning of- 5.5 TR Capacitiy Air cooled Ducted Split Air-Conditioner Unit. [Rated Cooling Capacity-90,000 BTU/HR-(min)] The Outdoor unit shall have 2 set R-410 A duty hermetic sealed scroll compressors of AC/ 3 ph/415 Volt power supply, 3 row deep Condenser Coil having internally grooved copper tube & aluminum fins, Propeller Fan with 220 V motor, control, gauges & accessories. Ceiling Suspended Indoor unit having air flow rate-3000 CFM (min) complete with 3 row deep evaporator coil shall have internally grooved copper tube & aluminum fins, DIDW centrifugal blower with direct drive motor, synthetic washable 10 micron filters, refrigerant controller, valves & gauges like multi port distributor, thermostatic expansion valves, electronic thermostat, refrigerant valves & all other accessories. The unit shall be provided with microprocessor based control panel with corded remote controller. (Make-Hitachi/Mitsubishi Heavy/ Daikin/Voltas)
Supply Installation, Testing & Commissioning of-2.0 TR Capacity Air Cooled Concealed Split Air-Conditioner Unit. [Rated Cooling Capacity-24,000 BTU/HR-(min)] The Outdoor unit shall have single R-410 A duty hermetic sealed rotary compressor of AC/220 Volt power supply, 2/3 row deep Condenser Coil having internally grooved copper tube & aluminum fins, Propeller Fan with 220 V motor, control, gauges & accessories. Ceiling Suspended Indoor unit having free air flow rate-800 CFM (min) complete with 4 row evaporator coil shall have internally grooved copper tube & aluminum fins, DIDW centrifugal blower with single phase motor synthetic washable 10 micron filters, refrigerant controller, valves & gauges like multi port distributor, thermostatic expansion valves, electronic thermostat, refrigerant valves & all other accessories. (Make-Hitachi/Mitsubishi Heavy/ Daikin/Voltas)
Supply, Installation, Laying, fitting, brazing jointing including leak testing of Hard Drawn Copper Refrigerant Piping Work In between each set of above AC Outdoor & Indoor units complete with necessary bend, elbow, tee & other fittings, GI bracket/ hanger supports etc. entire pipe line shall be duly insulated with 12/9 mm thick aluminum foil faced closed cell nitrile foam tube sleeve, each joint to be bonded with recomended adhesive & covered with self adhesive aluminum tape at 15" interval 1 1/2"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc.
7/8"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc.
5/8"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc.
1/4"φ Copper HD Pipe with Tee/ bend/ Reducer/Socket etc.
Control Cabling from ODU Unit to IDU unit of Ductable Split AC Communication Cable along with necessary sockets and glands.[NS] 4 Core 2.5 Sqmm unarmoured Copper cable
Supply & Laying Drain Water piping work out of PVC/HDPE hard pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(Mk. Oriplast /Supreme) [NS]
S& F of GI AC Tray underneath the indoor units of AC machines. 2.0 Tr
Supply & erection of GI Fire Damper with Fusible Link to be placed at blower outlet of supply air ducting for 5.5 Tr units
S&F IDU to Duct Chamber S & F flexible double canvass connection for Ductable Air conditioner.
Supply, Fitting & Balancing of Extruded Aluminum Powder Coated Supply Air Grille/ Diffusers with GI enamel painted oppose blade volume control dampers. Supply air grilles shall have duel adjustable louvers .Brand Approve by as directed by EIC.
Supply & Fixing of Thermal Insulation on Supply/ Return air ducting with 12mm thick aluminum foil pasted closed cell nitrile rubber sheet, to be fixed with special synthetic adhesives, jointing tape, etc. as required for the areas of duct as specified in approved shop drawings. Brand Approve by as directed by EIC.
Fabrication, Supply & erection of Supply & Return Air Ducting, fabricated out of galvanized sheet in rectangular or square in shape complete with bracing, flange connection, turning guide vanes, outlet collar, GI full threaded down rod with anchor fastener, supporting angle etc. as per constructional specifications & approved duct layout drawing.(Tata,Zindal) 22 Gauge GI Sheet Ducting
24 Gauge GI Sheet Ducting
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation Protection of outdoor unit of 1 nos. of 5.5 TR split concealed AC incl. by drilling 3 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 6 nos. of horizontal angle having size of 25 mm x 25 mm x 5 mm placed upon the base channel. The platform should be baricaded & safe for ODU Maintenance in outer edge by placing vertically 4 nos. of angle size 35 x 35 x 5 and 25 mm x 5 mm MS flat for connecting upto the edges of the angle.Area of the platform is 2.5 Mtr x 1.2 Mtr or as per Machine configuration & load with adequate service access as per direction of EIC. The charges for painting 1 coat of RO primer and 2 Coats of Aluminuim paint. scafolding arrangement.[NS]
Supply and installation of trap door of 1200 mm x 600 mm and 9 mm thickness ACP board (MAKE- Aludecor/ Urobond) or others reputed make) complete with linkages, levers, fitings.support all accessories for IDU maintenance made of aluminium channel & ply wood for IDU/Suction unit for maintenance as per direction of EIC.
The structure should be made of 1.5"x1", 16 SWG aluminium Angle . The grid (4'x3') of aluminium preperation in such way that it rest the ACP ducting .iii)Suspension :-Suspension is done from celling with 6mm/8mm dia 10' long GI threaded rod .the GI rod is fixed at ceiling with clamp & Flush nut . At least 8' gapping inbetween them Pasting of 9 mm thick Nitrile rubber thermal insulation with adhesive on ACP ducting cum ceiling . The insulating ruber containing thin aluminium foil on it at other side. (make-Supreme/alrmstrong or as directed byn EIC ).
Supply and fixing of 2 inch thickness thermal insulating medium made of thermocol to be pasted upon the outside wall of the building using necessary requirement of glue etc.and protective layer upon it to prevent it from further damage.
PART-B (E .I WORK) Supply and fixing of 3 phase Timer mini control panel within Horizontal PDB enclosure on wall comprising of i) 415 V AC, 4 Pole 25A Power contractor Make-L&T and Simense ii) Dial type analogue timer 24 hour C capacity, 230 V AC Supply, iii) 415 V, 25 A,4 POLE MCB C-type, Make-Siemense, legrand iv) 230 V AC toggle switch Single pole double through, 6 A 230 V, v) 415 V, 25 A, 3 way terminal vi) 15 A, 8 way phase & natural bar to be mount on DIN rail with 1.5 (control & sq. mm cu flexible 10 sq. mm(power) wire (finolex/havels/kei) including ferrule marking & socketing with in the Horizontal PDB MCB Enclosure Box( Make- Legrand / L&T) with LED indicator on wall angel iron frame
S&F AC machine timer for one no. machine febricated with double door 8 Way SPNDB as per L&T Cat no-LTSDO8N/Siemens/ABB) i) 240 V, 25A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T/Siemens/GIC)-1 No ii) 22A DP power contactor with 220 coil voltage (L&T, Cat no-MNX22-2P, CS90238/Siemens/GIC)-1 No. iii) Digital timer switch (L&T, cat no-Crono 67DDTO/Siemens/GIC)-1 No iv) Toggle switch -1 No. [NS]
S&F of outdoor type loop Box with 8" x 10" alongwith fitted din rail along 40 A Isolator . The cable entry area must be curved out of holes cutter. [Make-Legrand/Sintex/Hensel]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [Average run 11 mtr] 2(c)/E-1]
Supply & Fixing 240 V, 2 nos. 6A and 2 Nos. 16 A plug socket with separate 2nos. 6 A and 2 Nos. 16 A Piano key type switch, indicator & 25A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required[NS]
Supplying and fixing 20/25/32/40mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 2 x 4.0 Sqmm +1x 2.5 Sqmm
2 x 2.5 Sqmm +1x 1.5 Sqmm
2 x 6 Sqmm +1x 4 Sqmm [Acc. building ]
4 x 16 Sqmm+ 2 x 10 Sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 16 Sqmm
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make-Legrand/Siemens/ABB ] Up to 160A 8 way
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection[10/D-8] [Make-Legrand/Siemens/ABB] [160 A]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [MakeLegrand/Siemens/ABB] 63 TP
S & delivery of 4 Core 95 Sqmm (Al/Ar) Cable on wall/ surface with saddles/clamps incl S& F of MS saddles with earthing arrangement in 10 SWG Gi Hot dip wire making holes etc as necy mending good the damages and painting. [Academy SubStation To Administrative Building] & [ FP 15 to Normal Panel AVH] Make: Gloster/Havells/RR Kabel]
S & delivery of 4 Core 70 Sqmm (Al/Ar) Cable on wall/ surface with saddles/clamps incl S& F of MS saddles with earthing arrangement in 10 SWG Gi Hot dip wire making holes etc as necy mending good the damages and painting.[AVH Panel 2 to PDB 5&6,SOT] Make: Gloster/Havells/RR Kabel]
S & delivery of 4 Core 25 Sqmm (Al/Ar) Cable on wall/ surface with saddles/clamps incl S& F of MS saddles with earthing arrangement in 10 SWG Gi Hot dip wire making holes etc as necy mending good the damages and painting. [G&O 3rd Floor,Main Boys, Hostel TPN DB, Academy 4th Floor ]
S & delivery of 4 Core 10 Sqmm (Al/Ar) Cable on wall/ surface with saddles/clamps incl S& F of MS saddles with earthing arrangement in 10 SWG Gi Hot dip wire making holes etc as necy mending good the damages and painting. [VTPN to AC Outdoor ]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand[4(a)/F-3]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [2e/F-1]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 95 Sqmm
4 Core 70 Sqmm
4 Core 25 Sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :[7/F-4] 4 Core 95 Sqmm
4 Core 70 Sqmm
4 Core 25 Sqmm
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[4(a)/D-3] 160 A L&T/Siemens/ABB on Angle iron frame
Supply and delivery of 230 V,50 Hz, 450 mm sweep heavy duty Full metal body wall bracket fan having wattage less than 90 Watt RPM < 1325 Air displacement (in CFM 3550 complete with all accessories.[Make- Orient/ Crompton/ EPC]
Supplying and fixing of 3 Phase DOL Starter with short ciruit protection 9 HP 6.6 kW, Relay Range 3-14 A , 415 Volt [Make- Havells / ABB ] For 5.5 Tr
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [Make- Legrand] [5(a)/E-17]
Supply & Fixing 240 V, 21 A, OLP starter (Make-Electron) inbuilt protection on 4 Module MS Box flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[17/E-19]
Charges for Dismantling of old wiring, fittings & fixtures and ceiling fans and depositing to the respective section office including carying charges. [ 1 No. of Skilled and 1 no. of Unskilled technician]
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.[15/C-2]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire[21(a)/C-3]
Fixing only fan clamp for RC ceiling as per specification after cutting the ceiling & binding with reinforcement and mending good the damages.[27/C-3]
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.[Mending the damaged earthing continuity]
(Rate should be quotated including all taxes and duties, GST and considering the value of less cost materials.)
BANERJEE CONSTRUCTION AND CO (BID ID -7332739)
MODERN ELECTRIC (BID ID -7722087)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2138916.xls
BOQ • 0.33 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid