Loading…
Loading…
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
9 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
GE (West) Delhi Cantt-10
GE (West) Delhi Cantt-10
Repair/replacement including day to day maintenance of internal electric components including wiring, submain, VTPN DBs, light fittings and allied works in OTM Accn of 226 ASC,1811 Pioneer, ESD, 21 MC Group units under GE(West) Delhi Cantt-10
2026_MES_773365_1
GE/DW/TOKEN/47 OF 26-27
Open Tender
Civil Works
180 days
delhi
Class E and category a(i) or b(i)
9 documents required · 9 mandatory
₹500
GE(West) Delhi Cantt
₹50,000
Yes
19 Jun 2026
19 Jun 2026
11 Jul 2026
19 Jun 2026
9 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. | 460 | Per point | - | - |
| 2Material & Labour for point wiring with 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge at site for the following :- | |||||
| 2.01 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. (Switch to be measured and paid separately) complete all as specified and directed. | 270 | Per point | - | - |
| 3Material & Labour for point wiring with 2.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 2.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge at site for the following :- | |||||
| 3.01 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. (Switch and socket to be measured and paid separately) | 75 | Per point | - | - |
| 3.02 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board along with other switches. (Switch and socket to be measured and paid separately) | 35 | Per point | - | - |
| 3.03 | One 3 pin 6/16 Amps socket outlet point controlled by one way switch on independent board. (For Power Point) | 60 | Per point | - | - |
| 4 | Material & Labour for point wiring with 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction for one 3 pin AC Box outlet 20 Amps concealed and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge. (For AC point) | 20 | Per point | - | - |
| 5 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/fresh air fans and connects electric circuit, tightening of loose wiring/conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments,screwing/tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed. | 360 | Each Job | - | - |
| 6 | M&L for rewinding of ceiling fans of any type and make with super enamelled copper wire of appropriate gauge suiatble for existing make in the workshop including necessary lathe work on shaft, both sides of rewinding covered with high quality varnish and provisions of new nuts/pins including taking out old burnt wind of copper/aluminium complete all as specified and directed. | 220 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
ps47.pdf
Tender Documents • 0.77 MB
BOQ_865953.xls
BOQ • 1.17 MB
Download all tender documents and submit your bid