Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹29.4 L+₹74,275 (2.60%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹30.5 L+₹1.9 L (6.66%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹38.3 L+₹9.7 L (34.0%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹40.0 L+₹11.4 L (39.7%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
3 Jun 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIR MAINTENANCE AND OVERHAULING OF DG SETS AND ALLIED WORKS UNDER AGE EM NO-II OF GE U SECUNDERABAD
2020_MES_343218_1
GE(U)/SEC/TOKEN/05 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹84,000
Yes
14 Jul 2020
7 May 2020
5 Jun 2020
7 May 2020
3 Jun 2020
22 May 2020
Amount
M&L for Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- (i) Engine oil shall be measured and paid separately (ii) Labour & transportation shall be arranged by contractor,quoted rate deemed to be inclusive in the unit rate. Make: KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON
up to 18 KVA DG Set
above 18 KVA and up to 30kVA DG Set
above 30 KVA and up to 40KVA DG Set
above 40 KVA and up to 63 KVA DG Set
82.5 KVA DG Set
100 KVA DG Set
125 KVA DG Set
182.5 KVA DG Set
200 KVA to 250 KVA DG Set
320 KVA DG Set
400 KVA DG Set
625 KVA DG Set
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 150 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge. Make:- EXIDE/ AMARON
M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed by Engr-in-charge. Make:- EXIDE/ AMARON
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engr-in-charge. Note :- Spare Parts for rectify the fault is measured and paid seperately.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 125 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 125KVA and upto 320 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 320 KVA and up to 625 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
M&L for Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge for the following capacity DG Sets.
up to 30KVA
40KVA to 182.5 KVA DG set.
200 KVA to 400 KVA DG set.
500 KVA to 625 KVA DG set
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of 24 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.
M&L for Disconnecting the oil cooler of capacity up to 100 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge
M&L for Disconnecting the oil cooler of capacity above 100kVA to 320KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge
M&L for Disconnecting the oil cooler of above 320KVA and up to 625 kVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge
M&L for Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed by Engr-in-charge: - Make for item No.10 to 10.04:OEM recomended
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
above 320 KVA and up to 400 KVA DG Set
above 400 KVA and up to 625 KVA DG Set
M&L for Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the following DG sets all as specified and directed by Engr-in-Charge:
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
above 320 KVA and up to 400 KVA DG Set
above 400 KVA and up to 625 KVA DG Set
M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as directed by Engr-in-charge
S&F Automatic cut off type Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
M&L for Renewal/replacement of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- FENNER/ DUNLOP
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
above 320 KVA and up to 400 KVA DG Set
above 400 KVA and up to 625 KVA DG Set
M&L for Renewal/replacement of fan belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
above 320 KVA and up to 400 KVA DG Set
above 400 KVA and up to 625 KVA DG Set
M&L for Renewal/replacement of Dynamo belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
above 320 KVA and up to 400 KVA DG Set
above 400 KVA and up to 625 KVA DG Set
M&L disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.
M&L for replacement of existing unserviceable water temperature gauge with new water temperature gauge for the DG set of any description inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replaceemnt of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the DG set of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replacement of existing unserviceable oil pressure gauge with new oil pressure gauge for the DG SET of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replacement of unserviceable solenoid switch with new solenoid switch 12volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recomended
M&L for replacement of unserviceable solenoid switch with new solenoid switch 24volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recommended
S&F in repairs the following spare parts for any type/make of DG sets, as and when required by the department complete all as specified and directed. Make for item no 32.01 to 32.10:- OEM recommended
Starting/Ignition - key/button
Volt Meter 0-500V
Amps Meter
Frequency Meter
S.D Valve assembly
Oil safety control
Water safety control
Water separator bowl 3247715
Hour Meter
Radiator Metal Pipes
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO
Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 625 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set capacity up to100 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended
Drain out the fuel from the fuel tank of DG set of capacity 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.
escription all as per item No. 37 above but upto 500 Ltrs complete all as directed by Engr-in-charge.
S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 625 KVA capacity with all listed parameters including testing complete all as specified and directed.
S&F in replacement of Rectifiers of existing Make to DG Set capacity up to 100 KVA capacity with all listed parameters including testing complete all as specified and directed.
M &L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for up to 100KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 100 KVA to 320 KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.
M&L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for above 320 KVA to 625 KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.
M&L disconnecting & removing the unservicable AC wiring from AMF panel of DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & replacement of electrical/electronic spares and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. (ii) Electrical/Electrnoc spares shall be measured & paid separately under relevant items.
Supply only following spare parts :-
Push buttons
AMF Panel Hooter
Earth fault relay.Make: OEM recomeded
Over load relay.Make: OEM recomeded
Over/Under voltage relay.Make: OEM recomeded
Auxilary relays 12v/6Amps Make: OEM recomeded
Power Contactor 4 pole,02 NO +NC,400Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Power Contactor 4 pole,02 NO +NC,250AmpsAmps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Power Contactor 4 pole,02 NO +NC,200Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Power Contactor 4 pole,02 NO +NC,160Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Power Contactor 4 pole,02 NO +NC,130Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Power Contactor 4 pole,02 NO +NC,100Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Single phase preventer,make:minilec/GIC
Auxiliary Relays 24Volts / 6A Make: OEM recomeded
PLC based AMF relay unit Make: OEM recomeded
Low lube oil safety switch Make: OEM recomeded
Booster Relay 24Volts / 10A Make: OEM recomeded
Battery charger 24 V /10A panel mounting type Make: OEM recomeded
Battery charger 12 V /10A panel mounting type Make: OEM recomeded
Coolant temparature sensor Make: OEM recomeded
Power contactor 4 pole, 02NO+02NC,63 Amps ,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
contactor operating coil of Power contactor 4 pole, 02NO+02NC,400 Amps ,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Contactor operating coil of Power Contactor 4 pole,02 NO +NC,250AmpsAmps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Contactor operating coil of Power Contactor 4 pole,02 NO +NC,200Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
contactor operating coil of Power Contactor 4 pole,02 NO +NC,160Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
contactor operating coil of Power Contactor 4 pole,02 NO +NC,130Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
Contactor operating coil of Power Contactor 4 pole,02 NO +NC,100Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
contactor operating coil of Power contactor 4 pole, 02NO+02NC,63 Amps,Make: L&T/Tc/ABB/SIEMENS/Schnieder/GE
M&L for Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.
M&L for Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable spares for water manifold and Radiator spares upto 63 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 63 and upto 182.5 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 182.5 kVA and upto 320 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 320 kVA and upto 625 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as directed by Engr-in-charge.
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.
S&F battery brass terminal and jelly complete all as specified and directed.
M&L for Disconnecting all connection & remove the PT pump from engine and transport to OEM authorised service center and Calibration of PT pump for maximum efficiency by OEM Authorised Service center & replacement of PT Pump kit, gear gasket, etc in its original position by making all necessary connections complete whichever required under AGE E/M-II(U) AOR for smooth functioning of fllowing DG Set capacities complete all as directed by Engr-in-charge
DG Set capacity up to 63KVA
DG set capacity above 63KVA to 182.5KVA
DG Set capacity above 182.5KVA to 320KVA
DG Set capacity above 320KVA to 625KVA
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity up to 63 KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for Item No 57 above up to 63KVA capacity DG set
Supply only Barrel and Plunger for Item No 57 above up to 63KVA capacity DG set
Supply only FIP Bearing for Item No 57 above up to 63KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 63 KVA and upto 182.5KVA Note: Major spares required will be measured and paid seperately.
Supply only orfice for Item No 61 above above 63 KVA and upto 182.5KVA capacity DG set
Supply only Barrel and Plunger for Item No 61 above above 63 KVA and upto 182.5KVA capacity DG set
Supply only FIP Bearing for Item No 61 above above 63 KVA and upto 182.5KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following unservicable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 182.5 KVA and upto 320KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for Item No 65 above above 182.5 KVA and upto 320KVA capacity DG set
Supply only Barrel and Plunger for Item No 65 above 182.5 KVA and upto 320KVA capacity DG set
Supply only FIP Bearing for for Item No 65 above 182.5 KVA and upto 320KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 320 KVA and upto 625 KVA : Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 320 KVA and upto 625KVA capacity DG set
Supply only Barrel and Plunger for above above above 320 KVA and upto 625KVA capacity DG set
Supply only FIP Bearing for above above 320 KVA and upto 625KVA capacity DG set
Supply and fix self starter Motor, 24 volts, Make LUCAS or its equivalent make approved by OEM of DG Set suitable for existing DG set above 82.5 KVA to 400 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge
Supply and fix self starter Motor, 12 volts, Make LUCAS or its equivalent make approved OEM of DG Set suitable for existing DG set capacity up to 82.5 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge
S&F Flexible Bellow suitable for up to 182.5 KVA Gen Set. Make as per OEM
S&F Flexible Bellow suitable for above 182.5KVA and up to 625 KVA Gen Set. Make as per OEM
M&L for lifting the Gen Set above 125 KVA and up to 250 KVA after dissconnection complete from cables, Shifting to other place within 25 mtr sourrounding area and making PCC foundation of size suitable to existing DG Set with 1 : 2 : 4 PCC. Including smooth finishing. Shifting the DG Set on new foundation with all necessary arrangement of Cables Connections, Testing and commissioning complete all as directed by Engr-in-Charge. Notes :- All items & Manpower including Crane for lifting up and placing again on new foundation is included in quoted rates.
M&L for lifting the Gen Set upto 125 KVA after dissconnection complete from cables, Shifting to other place within 25 mtr sourrounding area and making PCC foundation of size suitable to existing DG Set, with 1 : 2 : 4 PCC. Including smooth finishing. Shifting the DG Set on new foundation with all necessary arrangement of Cables Connections, Testing and commissioning complete all as directed by Engr-in-Charge. Notes :- All items & Manpower including Crane for lifting up and placing again on new foundation is included in quoted rates.
M&L for Servicing of DG Set panel's ACB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
M&L for Servicing of DG Set panel's MCCB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 125kVA up to 320 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 320 KVA up to 625kVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 125 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity above 125KVA and up to 320 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity 125 to 625 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 125kVA up to 625 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
M&L for disconnecting all electrical & mechanical connections,Dismantle the Engine (make KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON) from 100KVA to 200 KVA DG set capacities located at various location under AGE E/M-II(U) and transported to OEM Authorised service center for complete overhauling, replacing the following unservicable worn-out spares with new appropriate make minor spares & major spares (minor spares- up to Rs 2500/Each), after assembling the spares the Engine again shfted to original existing place and reassembled to alternator& radiator,AMF panel/Electrical panel board of DG set complete testing, commissioning all as per OEM recomendation and as directed by Engr-in-charge.The quoted rate inclusive of Manpower, Crane charges for transporting engine to wokshop and back after repairs Note: - (i)Major Spare parts shall be measured and paid separately.
Supply only spare parts for Item No 90 above :-
Gear fuel Pump
Total Gakets Set
Core & cooler set
Shaft rocker arm
Oil seal
Ball Bearings set
Main Bearings set(STD)
Material and labour for repairs to Alternator of following DG Set, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note: Copper winding material will be measured and paid seperately under relevant Item
Upto 100 KVA capacity
Above 100 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity.
Above 320 KVA and upto 400 KVA Capacity
Supply only High conductivity copper conductor winding material including necessary insulation material as requred for complete all as specified and directed by Engr-in-Chrage
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same for the following capacities including testing complete all as specified and directed.
DG Set of capacity above 40 KVA and up to 82.5 KVA
DG Set of capacity above 100 KVA and up to to 182.5 KVA
DG Set of capacity above 182.5 KVA and up to 250 KVA
DG Set of capacity above 250KVA and up to 400 KVA
DG Set of capacity above 400 KVA and up to 625 KVA
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it out side work to workshop, complete all as specified and directed:-
DG Set of capacity 7.5 KVA To 40 KVA
DG Set of capacity above 40 KVA and up to 82.5 KVA
DG Set of capacity above 100 KVA and up to to 182.5 KVA
DG Set of capacity above 182.5 KVA and up to 250 KVA
DG Set of capacity above 250KVA and up to 400 KVA
DG Set of capacity above 400 KVA and up to 625 KVA
M & L for dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Value Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed:-
DG Set of capacity 7.5 KVA To 40 KVA
DG Set of capacity above 40 KVA and up to 82.5 KVA
DG Set of capacity above 100 KVA and up to to 182.5 KVA
DG Set of capacity above 182.5 KVA and up to 250 KVA
DG Set of capacity above 250KVA and up to 400 KVA
DG Set of capacity above 400 KVA and up to 625 KVA
M&L preparation of old painted surfaces of the DG Sets of the 7.5 KVA to 25 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 25 KVA and up to 82.5 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 82.5 KVA and up to 182.5 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 182.5 KVA and up to 320 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 320 KVA and up to 625 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
S&F in replacement of microprocessor based control unit suitable to DG set of 200 KVA to 320 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed.
S&F in replacement of microprocessor based control unit suitable to DG set of 400 KVA to 625 KVA capacity with all listed parameters as per OEM recommendation including testing complete all as specified and directed.
M&L on load change over switch 630 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T//HPL.
M&L on load change over switch 400 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L on load change over switch 320 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L on load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L Off load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,side handle operated with sheet metal enclosure suitable for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L Off load change over switch 400 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,side handle operated with sheet metal enclosure suitable for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
Supply and connect LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for the following sizes with necessary jointing materials complete all as directed by Engr-in-charge. Make :- M-SEAL/ DENSON/3-M/ RAYCHEM
3.5 core x 25/35 sqmm.
3.5 core x 70/95 sqmm.
3.5 core x 120/150 sqmm.
3.5 core x 185/240 sqmm.
3.5 core x 300/400Sqmm
Supply,test,install & commsissioning of Bus bar chambers(including 4 bus bars i.e R,Y,B and neutral),3-Ph with netral,1100volts,50Hz including suitable sheet metal enclosure along with necessary screws,nuts,bolts and other Misc accessroies and making connections(input &out put) with cable terminal ends complete for the following current carrying capacities Make: Havells/L&T/Standard
4-Way, 100 Amps
4-Way,250Amps
4-Way,400Amps
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 315 Amps to 400Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 630Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Supply&Fixing of 3 pole MCB,32-63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc of the following sizes and including taking out unserviceable burnt out cable from its existing location complete all as specified and directed by Engr-in-Charge :- Make for item No 116.01 to 116.08: Polycab/Havells/Gloster
2 Core X 10 Sqmm
4 Core X 16 Sqmm
3.5 Core X 25 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in soft/ loose soil complete all as specified and as directed Engineer-in-Charge.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engr-in-charge.
M & L Galvanised iron tubing 80 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply&Fixing of 200/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
Supply&Fixing of 400/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.
S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed . Make - Finolex/Havells/Standard /Finecab.
S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.
Notes for all items :- (a) Daily Collecting of complaints from JE/AGE is responsiblity of Contractor. After collecting Complaints from Complaint Register or Insturction by JE by Phone/SMS, complaint should be completed within 48 Hours of complaint receiving, Major complaints/AMF panel wiring/Rewinding etc items should be completed within 05 days, (b) Minimum 01 Technician with all tools, ladder and testing Equipment, as per the site requirement shall be provided by contractor. (c) Every month complete testing for serviceablity of DG Set for all Generator shall be done and reports submitted to Engr- in -Chage at the end of every month (if items required shall be paid under relevant items given above). (d) Documents required for complaints like Stationery, Complaint Register, Slips & Site Order Book shall be provided by the contactor.(e) safety precautions shall be responsible by the contractor. (f) Contractor to comply all the respective notes of Particular Specifications attached.
SUN LIGHT HOUSE
omsai thermax engineers
STANDARD AGENCIES
Srinivasa Consructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .