| Sl No | Description | Qty | Unit | Auto Traders L3 | M/s DKS Electricals L1 | m/s rudraksh enterprises L5 | JYOTI ENTERPRISES L4 | Manu Enterprises L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down ceiling fan and exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fans and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed. | 586 | Each | 49 ₹28,714 | 25 ₹14,650 | 40 ₹23,440 | 45 ₹26,370 | 10 ₹5,860 |
| 2.00 | Taking down AC of any size, any capacity from existing location and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed. | 40 | Each | 449 ₹17,960 | 340 ₹13,600 | 500 ₹20,000 | 450 ₹18,000 | 100 ₹4,000 |
| 3.00 | M & L for sub main wiring with 02 runs of 6 Sqmm main wire along with 01 run of 06 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unsv sub main wiring complete all as specified and directed.
Note:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. | 332 | RM | 333 ₹1.1 L | 210 ₹69,720 | 340 ₹1.1 L | 450 ₹1.5 L | 260 ₹86,320 |
| 4.00 | S&F in repair for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with one single pole MCB SP 20 Amps complete all as specified and directed. | 20 | Each | 690 ₹13,800 | 850 ₹17,000 | 700 ₹14,000 | 900 ₹18,000 | 800 ₹16,000 |
| 5.00 | S&F of ceiling fans complete with blades including fan down rods upto two mtr, operating with regulator complete accessories, 230 V, 50Hz, 1400mm sweep and winding material : super enamelled copper wire rated power 32W (+10%) and rate speed 350 RPM (+10%) power factor 0.90 min, air delivery 220 CMM with service value shall not be less than 6.87 BEE as per BIS. Five star rated with brushless direct current motor (BLDC), painting to match with existing surfaces including writing the MES number complete all as specified and directed. | 577 | Each | 3,049 ₹17.6 L | 2,950 ₹17.0 L | 2,590 ₹14.9 L | 3,060 ₹17.7 L | 3,100 ₹17.9 L |
| 6.00 | S&F of exhaust fan , steel body AC single phase 230 volt of size 450mm sweep complete with blade, frame and louvers and mesh wire for cover the wall from outside including addition/ alteration of hole wherever necessary and making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed. | 8 | Each | 4,149 ₹33,192 | 5,560 ₹44,480 | 4,850 ₹38,800 | 3,060 ₹24,480 | 5,000 ₹40,000 |
| 7.00 | S&F of exhaust fan , steel body AC single phase 230 volt of size 380mm sweep complete with blade, frame and louvers and mesh wire for cover the wall from outside including addition/ alteration of hole wherever necessary and making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed. | 1 | Each | 3,500 ₹3,500 | 4,226 ₹4,226 | 3,850 ₹3,850 | 2,970 ₹2,970 | 4,500 ₹4,500 |
| 8.00 | S&F wall fans complete with blades and accessories, 230 V, 50Hz, 400mm sweep. Five star rated, including writing the MES number with synthetic enamel paint complete all as specified and directed. | 12 | Each | 2,600 ₹31,200 | 2,650 ₹31,800 | 2,350 ₹28,200 | 2,520 ₹30,240 | 3,000 ₹36,000 |
| 9.00 | Supply and install, testing hi wall 1.5 TR split units indoor/ outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum BEE 5 rating and not less than EER 3.2 of capacity as shown and refrigerant copper tubing of adequate length upto 20 feet as required at site and indoor mounting plate duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerant gas including making round hole on existing wall for taking up refrigerant tubing, heavy duty drain pipe upto 3 mtr with saddling, cable etc and making good disturbed surfaces by matching with existing adjoining surface colour complete all as specified and directed,
Note:- AC to be installed at various height and location of the building including outdoor unit with suitable size mounting bracket. The rates of mounting of bracket shall be deemed to be included in the quoted rates. | 40 | Each | 54,000 ₹21.6 L | 47,004 ₹18.8 L | 61,500 ₹24.6 L | 54,000 ₹21.6 L | 47,000 ₹18.8 L |
Updated dates
Tender Value
₹38.8 L
EMD Value
₹77,660
Closing Date
24 Feb 2026, 6:00 pmClosed
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
SPL REPAIR/ REPLACEMENT OF COOLING APPLIANCES AND SUMMER APPLIANCES AGAINST BER UNDER GE (MCTE) MHOW
2026_MES_747791_1
GE(MCTE)/MHOW/25(T) OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
Yes
GE (MCTE) Mhow
₹77,660
Yes
2 Apr 2026
9 Jan 2026
26 Feb 2026
9 Jan 2026
24 Feb 2026
30 Jan 2026
Taking down ceiling fan and exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fans and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed.
Taking down AC of any size, any capacity from existing location and deposit to MES store yard of AGE E/M No-III Mhow complete all as specified and as directed.
M & L for sub main wiring with 02 runs of 6 Sqmm main wire along with 01 run of 06 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unsv sub main wiring complete all as specified and directed. Note:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S&F in repair for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with one single pole MCB SP 20 Amps complete all as specified and directed.
S&F of ceiling fans complete with blades, down rods 15mm/ 12mm upto two mtr, including remote with battery and complete accessories, 230 V, 50Hz, 1400mm sweep and rated power 26W (+ 10%) and rate speed 350 RPM (+10%) Min air delivery 210 CFM with service value shall not be less than 8.00 BEE as per BIS. Five star rated with brushless direct current motor (BLDC), painting to match with existing surfaces including writing the MES number on the fan complete all as specified and directed.
S&F of exhaust fan , steel body AC single phase 230 volt of size 450mm sweep complete with blade, frame and louvers and mesh wire for cover the wall from outside including addition/ alteration of hole wherever necessary and making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed.
S&F of exhaust fan , steel body AC single phase 230 volt of size 380mm sweep complete with blade, frame and louvers and mesh wire for cover the wall from outside including addition/ alteration of hole wherever necessary and making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed.
S&F wall fans complete with blades and accessories, 230 V, 50Hz, 400mm sweep. Five star rated, including writing the MES number with synthetic enamel paint complete all as specified and directed.
Supply, installed, commissioning and testing hi wall 1.5 TR split inverter AC units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and not less than EER 3.2 of capacity as shown and regrigerant tubing of adequate length upto 20 feet as required at site and indoor mounting plate duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initinal filling of refrigerant gas including making round hole on existing wall for taking up refrigerant tubing, drain pipe upto 3 mtr with saddling, cable etc and making good disturbed surfaces by matching with existing adjoining surface colour complete all as specified and directed, Note:- AC to be installed at various height and location of the building.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Make25T.pdf
Tender Documents • 0.23 MB
TD25T.pdf
Tender Documents • 0.76 MB
PS-25T.pdf
Tender Documents • 0.31 MB
BOQ_837420.xls
BOQ • 1.82 MB
Undertaking25T.pdf
Additional Documents • 0.10 MB
Download all tender documents and submit your bid