| 1 | L1₹22.1 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹23.5 L+₹82,626 (3.65%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹24.8 L+₹2.2 L (9.74%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹47.7 L+₹25.0 L (110.5%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹48.5 L+₹25.9 L (114.2%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Rejected |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
16 Sept 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
PAINTING/CLEANING OF OVERHEAD RESERVOIRS/TANKS AND CERTAIN REPAIRS TO INSTALLATIONS UNDER AGE B/RI OF GE SUBROTO PARK
2023_MES_614751_1
GE/SP/ TOKEN-51/2023-24
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹1 L
Yes
15 Dec 2023
21 Aug 2023
23 Sept 2023
21 Aug 2023
16 Sept 2023
4 Sept 2023
Amount
Disconnecting existing tanks exc 250 and n.exc 500 ltrs and above, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately but including the writing letters or figures in (Block,Roma, Italic or Indian) n exc 30 Cm high using stencils with white synthetic enamel paint .Writng matter is (DATE OF CLEANED: )
Disconnecting existing tanks exc 500 and n.exc 1000 ltrs and above, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately but including the writing letters or figures in (Block,Roma, Italic or Indian) n exc 30 Cm high using stencils with white synthetic enamel paint .Writng matter is (DATE OF CLEANED: )
M&L for cleaning and removing all scale and dirt etc from tanks and mouths of circulating pipes, tank capacity exc 250 Ltrs but n exc 500 Ltrs capacity complete all as specified and directed.
M&L Cleaning and removing all scale and dirt etc from tanks and mouths of circulating pipes, tank capacity exc 500 Ltrs but n exc1000 Ltrs capacity complete all as specified and directed.
Dismantling existing tanks capacity exc. 250 ltr but n.exc 500 ltr,and removing.
Dismantling existing tanks capacity exc. 500 ltr but n.exc 1000 ltr,and removing.
S&F tripple layer rotational moulded vertical water storage tanks with closed tops white in colour ( cylinderical ) hoisted and fixed in position 1000 ltr capacity incl disconnecting and refixing the existing GI fitting and pipe complete
S&F tripple layer rotational moulded vertical water storage tanks with closed tops white in colour ( cylinderical ) hoisted and fixed in position 500 ltr capacity incl disconnecting and refixing the existing GI fitting and pipe complete
Taking down cement of cement lime plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 15mm thick plastering in CM 1:6 on any faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement on internal surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 5mm thick cement mortar (1:3) as in ceiling, soffit of staircase, chhajjas facia etc including cement slurry etc complete all as specified and as directed by the Engineer-in-Charge.
M&L renderning 15 mm thick plastering in CM 1:4 on brick or concrete surfaces on external surfaces finished even and fair complete all as specified and directed..
M&L applying three coats of white wash on ceiling, soffit of chhajjas facia etc newly plastered surfaces including preparation complete all as specified and as directed by the Engineer-in-Charge.
M&L distempering with Ist class acrylic distemper (ready mixed) having VOC content less than 50 gm/litre, of approved manufacturer, of required shade and colour complete as per manufacturer's specification. To or more coats on new work including preparation of new plastered surfaces complete all as specified and directed.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2014, Alkali and fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10sqm and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new plastered surfaces of wall/soffits of chajjas etc including preparation complete all as specified.
M&L applying one coat of white wash on wall including preparation of old painted surfaces with brooming down or steel wire brushing, scrapping down smoke soot, moulds,moss and efflorescent salts and trading oil and greasy spots complete all as specified.
M&L applying one coat of white wash on soffits/ceiling surfaces including preparation of old painted surfaces with brooming down or steel wire brushing, scrapping down smoke soot, moulds,moss and efflorescent salts and trading oil and greasy spots complete all as specified.
M&L finishing wall with Acrylic smooth exterior paint of required shade: old surfaces ( two or more coats applied @ 1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) including complete removal of existing treatment from walls and preparation of surfaces complete all as specified. Note :- The work shall also be carried out on over head reserviour upto 25 M height and cost of scaffolding required to carry out the work is deemed to be inclusive of rate quoted.
M&L applying one coat of synthetic enamel paint on old wooden surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L applying one coat of synthetic enamel paint on old steel surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L cutting/uprooting/clearing grass,bushes/plants ( girth n exc 15 cm of trunk to any of plants) in the premises of installations around over head resevious staging and other such locations as directed by Engr-in-Charge including removal of rubbish so obtained out side the area exc 50 M but n exc 250M complete all as specified.
M&L uprooting grass/ plants (girth n.exc 15 cm of trunk to any of plants)grown along the pipes or walls, chajjas, parapets and roof or any othder location on the building/over head tanks and reserviours upto fourth storey height including making good the surface as per existing surface and pouring acid not less than 100 ml for each plant in the roof to avoid further growth as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground levels,incl removing the demolished material outside the MOD land.
M&L 75mm thick PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in plinth protection finished even & fair including making groove not exc 3.00 meter interval and filling the same with mixture of sand and bitumen complete all as specified and directed.
M&L cement concrete 40mm thick type B-1, 1:2:4 (using 20mm graded stone aggregate) in floors pavings etc finished even & smooth with out using extra cement.
S&F glass dividing strips 3mm thick and 38mm wide inserted in position.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for PCC 1:2:4 type B-1(20mm graded aggregate), 25mm thick as in sub base to the tile flooring complete all as specified and directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors or dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and directed.
M&L Glazed printed/ coloured ceramic tiles in vertical surface 300x 600x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment and different colour shades patterns complete all as specified and directed.
M&L for oil bound distemper two coats over a coat of primer including preparation of newly plstered surfaces of walls or unplastered surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M&L applying one coat of distemper oil emulsion white or tinted including preparation old painted surfaces of walls complete all as specified and directed.
Demolition of brick work or stone masonry including pillars, cornices,arches etc built in cement mortar or cement lime mortar complete all as specified and dircted,
M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius in CM 1:4 complete all as specified and directed.
Taking down frame or Chowkhats (w/o taking off shutter from the frame) of any description exc. 1.50 Sqm and not exc. 4.00 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and directed.
Taking down frame or Chowkhats (w/o taking off shutter from the frame ) of any description not exc. 1.50 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Taking down shutter of any description exc. 1.0 Sqm but n exc 2.0 Sqm each complete all as specified and directed.
S&F framed work as in doors chowkats or gates of angle iron or other section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging doors fittings complete all as specified and directed.
S&F 35 mm thick plain framed panelled shutters (two or more panesl) with lock rail and panel of 9 mm BWP commercial ply wood. The size of rails and stiles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified.
S&F steel windows/ventilators with side hung shutters including projecting type hinges with steel handles and steel peg stay complete with glazing bars, devotailed or welded complete all as specified.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wood surface complete all as specified and directed.
S&F 100 mm long butt hinges medium weight cold rolled mild steel alloy with galvanized complete all as specified and directed.
S&F 150 mm long Aluminium door handle, cast type, anodized complete all as specified and directed.
S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F door stopper of aluminium, alloy body and tongue with hard drawn steel spring fixed in floors of 140 mm overall length of cover plate complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/ Steel /Aluminium frames glazed with putty or fixed with bead. (Old bead to be reused to fix glass) complete all as specified and directed.
Taking down or up steel water tubing and connections including cleaning for re-fixing of 15 mm bore removing the debris including mortar out side defence land complete all as specified and directed by Engineer-in-Charge.
All as per above Item No 52 but 20 mm bore.
S & F steel water tubing, galvanised, medium grade, ISI marked with all fittings and fixed on walls and ceilings or laid in floors bore of pipe 15 mm complete all as specified and directed by Engineer-in-Charge.
All as per Item No 54 above but 20 mm bore.
S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed suitable for iron pipe 20mm bore having weight not less than 210 gms complete all as specified and directed by Engineer-in-Charge.
S& F in repair 110 mm bore PVC (SWR ) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors etc including removing from site complete all as specified and directed by Engr - in- charge.
S&F in repair PVC (SWR) bends any radius for 110 mm bore PVC pipe with cement joints complete all as specified and as directed.
M&L chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, with grey cement and no pigment ,machine pressed, set and jointed and pointed in neat cement slurry in floorsover and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L machine cut kota stone slab flooring 20-25 mm thick over cement screed base 15 mm thick in cement mortar and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
All as per item No 60 above but in vertical surfaces such as dado/skirting over and including rendering 15 mm thick in cement mortar 1:4 complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, approns, vertical surface of walls etc..
Taking down existing steel rolling shutter incl hood cover pull & push type not exc 12 Sqm area of clear opening and cleaning the sides of shutters suspensions shafts,anti-guide channels and greasing all the moving parts of rolling shutters and straightening rolling shafts and replacement of bolts and nuts as required for smooth functioning of shutters and refixing the same incl hood cover complete all as specified and as directed.
S&F in repairs mild steel angle iron, flats and similar section, work as in post and struts in fencing including cutting tops to shape as directed, drilling holes,notching for ire etc,flat iron fillets(for securing ire mesh or chainlink fencing) including embeding post in concrete and all other necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified.
S&F in repairs chain link fencing mild steel galvanised fencing,any size or type to any type of standard rails, straining bolts, nuts, flat iron etc including provision of bininding wire if required complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in footings for fixing fencing posts complete all as specified and directed.
Excavating in post holes(or similar holes) in soft/loose soil, each n exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm thick including removal of surplus soil to a distance n, exc 50 m complete all as specified and directed.
Ashish Sehgal and Co.
shakti construction
deepankar trading co.
shiva enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .