| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.1 LAccepted-AOC | L-1 | Accepted-AOC Accept | |
| 2 | L-2₹38.4 L+₹33,891.14 (0.89%)Rejected-Finance 50 PANCHVATI COLONY KODARIYA MHOW PIN 453441 | MHOW | MHOW | MP | 453441 | L-2 | Rejected-Finance High Rates | |
| 3 | L-3₹38.6 L+₹54,876.79 (1.44%)Rejected-Finance | L-3 | Rejected-Finance High Rates | |
| 4 | L-4₹42.4 L+₹4.4 L (11.4%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L-4 | Rejected-Finance High Rates |
Tender Value
₹41.2 L
EMD Value
₹82,340
Closing Date
9 Nov 2022, 6:00 pmClosed
GE (MCTE) Mhow
GE (MCTE) Mhow (MP) 453441
SPL REPAIR TO BUILDING NO WB-134 (NCOS BLOCK) OF MCTE AND WALKING PATH AROUND CHILDREN PARK NEAR DENNIS ROAD UNDER GE (MCTE), MHOW
2022_MES_553625_2
GE(MCTE)/MHOW/41(T) OF 2022-23
Open Tender
Civil Works
Works
180 days
GE (MCTE) Mhow
As Per Tender Document
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) Mhow
₹82,340
Yes
31 Dec 2022
21 Oct 2022
11 Nov 2022
21 Oct 2022
9 Nov 2022
27 Oct 2022
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provider for complete all as specified and directed.
Dismantling PVC water tanks Exc 250 ltrs but not 500 ltrs including taking down of float valve and removing from site complete.
S&F 500 Ltrs capacity rotational moulded polyethylene water storage tanks, (cylindrical vertical with threaded closed top) hoisted and fixed in position, all as specified and directed complete.
S&F in repair ball valve/float ball high pressure of PTMT 20mm with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimum weight 210 gm etc all as specified and directed.
Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, and Cutting chases for concealed water tubing in brick wall and making good in CM 1:3 cutting n.exc 10cm girth.and including taking down exsiting steel tubing complete for the following sizes: -
(a) 15mm dia bore
(b) 20mm dia bore
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed.
M & L for non-skid/ mat finish coloured joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles, 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick on vertical surfaces such as dados, skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat to receiving to wall tiles in Cement mortar 1:4 complete all as specified and directed.
Mirror polish on kota stone where ever required to give high glossy finish over existing floor complete all as specified and directed.
Dismantling of stone slabs and tiles Interlocking of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed
M&L for black Granite 20mm thick(of any type) work (table rubbed and polished) for wall lining (Veneering to wall) and laid on cill of parapet wall cooking platform over 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite colour Red or brown including round the edging as wherever required as per direction of GE
M & L for 20-25mm thick machine cut Kota stone slab in flooring or treads single piece of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note :- The size of Kota stone slab shall not less than 550mm x 550mm cut size, except the location where the balance portion remain less than size as specified above.
All as per item No.12 above but as in skirting or vertical surfaces including 10mm thick rendering in cement mortar 1:4, complete all as directed and specified.
Taking down chowkhats or frames not exc 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkhats or frame exc 1.5 sqm but not exc 4 sqm with shutter (without taking off shutter frome the frame) complete all as specified and directed.
S & F 125 x 60mm x 1.5mm thick size Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,hold fast etc., complete as specified
M&L for PCC (1:2:4) type 1:2:4 B0 with using 12.5mm graded stone aggregate as in bed blocks, coping, for fixing holdfast/lugs,filling hollow space of pressed steel door frame etc including necessary form work all complete as specified and as directed.
M & L for 2nd class hard wood 35mm thick Plain, framed panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as speciifed and directed.
S & F for 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) fitted to chowkats complete all as specified and directed. Note :- Glass pane and wire mesh shall be measured and paid separately in respective supply only item.
S & F PVC solid factory made door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as shown in drawing on Sl. Page No.180 of SSR Part-II
S & F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as directed by GE/ Engineer-in-Charge and all as shown in drawing on Sl. Page No.176 of SSR Part-II
S & F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete .
S & F aluminium 200mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.
S & F aluminium 150mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete.
S & F 150mm size aluminium handles cast type, anodised ISI marked complete
S & F 250mm aluminium alloy, anodised sliding door bolt ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete.
S & F 300mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete fixed to steel frame/ wooden frame including necessary welding, cutting, opening of wall for fixing bracket and making good complete.
Providing and fixing fixed louvers Eco Series fabricated from Roll formed sections made of galvanized Steel colour coated/powder coated (base Steel as per IS 513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 grams/ Sqm) with thickness of 0.58mm coated sections to be primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick, section for external frame 33 x 58mm, glass holding flanges made of polypropylene, sections are to be cut to length, mitre jointed with corner bracket. The above frames should be fixed to the concrete/ masonry walls by means of self expanding screws incl window glass 4mm thick. & making good the adjacent sides of jambs of ventilators by plastering in CM (1:4) all as specified and directed by Engineer-in-charge. Make : NCL or equivalent as approved by GE.
Providing and fixing pre painted steel sliding windows Eco Series 3-Track, 2 glass panel and 01 SS mesh panel sliding window including grill fabricated from Roll formed sections made of galvanized Steel colour coated/ powder coated (Base Steel as paer IS 513 'D' quality, galvanized as per IS 277 with zinc of 120 Gm/Sqm) with total coated thickness of 0.58mm. Primer coat with epoxy primer 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 micron thick. Section for external frame should be of 107 x 44mm, section for shutter should 35 x 49mm. Section of mesh should be of 35 x 49mm. The windows should be paneled with 4mm thick plain clear glass. Corner bracket for internal and external frame made of glass filled nylon. Gaskets are to be made of Ethyl Propylene Diamine Monomer (EPDM). The sections to length, joined and assembled by means of corner bracket. The above frames should fixed to the concrete/ masonry walls by means of self expanding screws, including supply and fixing of MS grill 10mm solid square bare @ 150mm centre to centre for horizontal direction and two 10mm solid square bare in vertical direction alongwith all-round the frame using 30mm x 3mm MS flat with necessary welding and fixing anchorage and making good the adjacent sides of jambs of windows i.e, plastering in CM 1:4 complete all as specified and directed. Make : NCL or equivalent.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over & including of redoxide zinc chrome coat complete all as specified and as directed.
M & L for preparation of old painted steel surfaces of any description over 10 cm in width or girth not otherwise described and applying one coats of synthetic enamel paint over of redoxide zinc chrome coat complete all as specified and as directed.
M & L for Preparation of New wood or previously untreated surfaces of any description, not otherwise description, over 10 cm width or grith apply two coat of synthetic enemel paint (ordinary tint) over & including a coat of pink primer complete all as specifed and directed.
M & L for Preparation of old painted wooden surfaces of any description, not otherwise description, over 10 cm width or grith apply one coat of synthetic enemel paint (ordinary tint) over a coat of pink primer complete all as specifed and directed.
S&F in repair stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm
Demolition of Brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed
M&L for Brick work with sub class 'B' modular brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
M & L for reparing of RCC projection, chajjas, roofs, facia, coloum beam etc by necessary preparation i.e scrapping, cutting, chiseling, derusting and cleaning exposed reinforecement, surfaces of damaged, loose RCC surfaces and applying one coat of rust remover by brushing to rusted reinforecemnt to remove loose rust particles and allow to dry it for 2 to 3 Hrs, insert the new reinforcement to damaged portion by drillig hole at required distance, fill the epoxy in to the hole by 2/3 of the hole and insert the reinforcement in the hole, and binding the reinforcement at rusted portion of reinforcement, apply Nitobond chemical overexisting concrete area as per manufactured instruction, and plaster the surfaces with cement, sand and Polymer liquid in 1: 3 : 15% of cement by weight and water as required, mixing properly and plaster the surface, finished even and smooth by making the edge water dropping grooves complete all as specified and directed. Note :- (i) Cost of formwork shall be deemed to be included. (ii) Work shall be got done from authorised applicator as approved by the GE.
Taking down cement plaster any description on brick, concrete stone surfaces incl. raking out joints hacking for key, scrubbing down with water etc.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in two layers (10mm thick bottom layer & top layer 5mm thick), mixed with water proofing compound in top layer by weight of cement or as per manufacturer instructions, finished even & fair without using extra cement all complete as specified and as directed. (Note :- water proofing compound will measured and paid separately)
Supply only Integral water proofing compound conforming to ISI
M&L for rendering 15mm thick cement plaster on other than fair surfaces of brick work in cement mortar (1:6) complete all as specified and as directed.
M&L for rendering 5mm thick cement plaster on ceiling in cement mortar (1:3) finished fair & even complete all as specified and directed.
M&L for applying three coats of white washing on new plastered surfaces of ceiling including preparation complete all as specified and directed.
M & L for preparing old decorated plaster or un-plastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M & L for Preparation of newly plasterd wall surface apply two coat of Anti fungal weather coat acrylic emulsion paint over & including a one coat of wall primer plastered and other surface with alkali resistant priming paint complete all as specified and directed.
M&L for Preparation of decorated old plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of Anti fungal weather coat acrylic emulsion paint paint including washing floors, cleaning glass, joinery, electrical fittings wiring etc, of drops and splashes complete all as specified.
Complete Removal of Existing treatment on walls/ Ceiling including washing rubbing down and stopping of distempered and painted surfaces
M&L for preparation of new plastered surfaces of walls and provision of 1mm thick birla white wall care putty and applying a coat of primer chalk whiting on new plastered surfaces of walls and applying two coats of oil emulsion distemper
Preparation of old plastered surface of walls and provision of 1mm thick birla white wall care putty and applying a coat of primer chalk whiting on old plastered surfaces including two coats of oil bound distemper on wall surface.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc. 15cm thickness (below or above ground level all as specified and directed).
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate 75mm thick as in plinth protection, finished concrete surfaces even and smooth without using extra cement complete all as specified and directed.
S & F in repairs Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes coupling, including bedding in cement mortar to dwarf wall or including fixing cantiliver brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330 x 160mm complete all as specified and directed. (Make : Nirali or equivalent approved)
S & F in repair vitreous china squatting pan “ORISSA PATTERN” of size 580mm x 440mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete.
Supply and fixed in repair 10 Ltr capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with and including 32mm bore PVC flush pipe complete all as specified and directed.
S&F in repair PVC connection pipe 15mm bore 450 long with PTMT nut at both ends complete.
S & F (in repair) brass chromium plated angle cock 15mm bore screwed for iron pipe or brass ferrule, complete. Make : Plumber Cat No FLP-0507/ Prayag Cat Part No 7810/ Jaquar Cat Part No CQT-23059 complete all as specified and approved.
S&F for brass chromium plated tubular towel rail, 20mm bore, D type, 60cm long between flanges
S&F in repairs swivel shower of CP with shower arm 15mm size any colour for fixing with 15mm pipe. Make : Jaquar, Plumber or equivalent approved
S&F in repair 15mm bore concealed type stop valves, cast copper alloy, chromium plated, screwed down, high pressure with handle, screwed both ends for iron pipe or union complete all as specified and directed. Make : Jaquar, Plumber or equivalent approved
S & F in repair 15mm bore Bib tap fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make : Jaquar, Plumber or equivalent approved
S&F in repairs powder coated steel peg set having 06 Nos spikes fixed to wall complete all as specified and directed (Make as approved by GE)
S&F in repair decorative curtain rod 25 dia with decorative head on both end of rod and necessary clamps/ fixing brackets, stops, rollers etc. complete fitment all as specifed and as directed.
S & F in repair Gun-metal, globe of gate valve/ flush cock of 20mm bore with iron wheel head, screwed both ends for iron pipe etc all as specified.
S & F in repair PVC (SWR) nahani trap with grating having diameter of outlet 110mm including joining to waste pipe with solvent cement complete.
S & F in repair 110mm bore. PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floor/ trenches complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in floor/ trenches complete all as specified and directed.
S & F in repair 110mm bore. PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) bends any radius with solvent rubber ring joints, fixed complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) bends any radius with solvent rubber ring joints, fixed complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) junction single, single (T) equal or unequal with solvent rubber ring joints, fixed complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) junction single, single (T) equal or unequal with solvent rubber ring joints, fixed complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) branch piece single (single Y) equal or unequal with rubber ring joints, fixed complete all as specified and directed.
S & F in repair 75mm dia bore PVC (SWR) branch piece single (single Y) equal or unequal with rubber ring joints, fixed complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) vent cowl rubber ring joints, fixed complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5M wide and not exceeding 1.5M in depth for foundation sewage line, manhole etc not exceeding 10sqm on plan and getting out in any type of soil complete.
Returning, filling in Soft/ Loose soil including spreading, levelling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete.
Demolition of reinforced cement concrete of any description complete as specified and directed.
M & L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregate as in Chajja all as specified and directed.
Use & waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges. all as specified and directed
S & F mild steel TMT bars 6 to 8mm dia as in reinforcement, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm bore or securing with clips complete.
M & L for repair to sunken floor by provide water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed :- (a) Provide PCC 1 : 1.5 : 3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement. (b) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion. (c) Applying surfaces of bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. on complete sunken surfaces of floor & wall and provide necessary connections to soil/ waste pipe from WC/ nahani trap etc including demolation of old sunken complete all as specified and as directed. (d) Applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat would be paid seperately). (e) APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and directed. Note : (i) Floor Area shall be measured for payment. (ii) Treatment shall be carried out from authorised applicator as approved by the GE with testing & 10 years guarantee bond.
M & L for provide PVC spout pipe of 25mm bore & 45cm length in sunken floor including cutting holes in brick walls built in cement mortor and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate with wall finish at the disturbed portion of external surfaces complete as directed and specified.
Removing excavated material exc. 50m and and n.exc 100m, depositing where directed at a level n exc. 1.5 m above the starting point
M&L for 150mm thick Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
M&L for PCC (1:4:8), 150mm thick, type D-2 using 40 mm graded stone aggregate in sub base for receiving interlocking tiles, chequered cement tiles etc complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 Grade, with using grey cement and not pigment complete all as specified (Note :- shape of paver block shall be got approved from GE before incorporation in work)
M&L for PPC 1:2:4 type B-1 using 20mm graded crushed stone aggregate in roof kerbs or mud stops, coping, rounded or chamfered on edges of interlocking tiles etc all as directed.
M & L for pre-cast cement concrete in kerb stone, type B0 1:2:4 (unsing 12.5mm graded stone aggt) of size 30cm (length) x 30cm (height) x 80mm thick all surfaces finished even and smooth without using extra cement incl jointing in cement mortar 1:4 complete all as specified and directed. Note : One edge of PCC kerb stone should be (i.e. 30cm long side) slightly rounded/ chamfered shaped and no additional cost to be paid for the same).
M&L for preparation of concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of weatherproof emulsion paint over a coat of concrete primer complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate in foundation, filling and mass concrete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping etc. incl. fromwork complete all as specified and directed.
M&L for providing reinforced cement concrete Type B-1, (1:2:4) (using 20mm grade aggregate) as in slab supported on walls, beams and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape as reqd, including cranking, bending srirally for hooping for columns, hooking ends binding with and including MS (annealed) wire not less than 0.9mm dia or securing with clips all as specified.
Use & work of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) incl edge of concrete.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc, and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully copper/ aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully MCB DBs/sheet metal earth plug socket any size and any type including MCBs any type and making good the disturbed surface of walls and floors etc all as directed by Engr-in-Charge.
Taking down existing ceiling fans/ Exhaust fan any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/ connector complete all as specified and directed by Engr-in-Charge.
Taking down existing geyser any size in position and re-fixing the same after B/R work including over oiling, painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable with 16 Amps Pin top for connection from MCB box/16 Amps socket complete all as specified and directed by Engr-in-Charge.
Taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and re fixing after work above the suaitable rectangular wooden box including all fixing arrangement complete all as specified and as directed.
Taking down existing old unserviceble LT UG/ service cable of any descrition and size complete all as specified and directed .
Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FRLSH copper conductor cable in and including rigid non-metallic PVC concealed conduit of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular metal flush box, modular cover plate and modular cover frame of suitable size all fittings and accessories and making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:- Make of cable : Havells/ Finolex/ RR Kabel Ltd./ L&T Make of PVC Conduit (FRLS) : Presto Plast/ Finolex/ Jindal/ Asian/ AKG
(a) One light/ fan/ bell point controlled by one switch
(b) One light/ fan/ bell controlled by one, two way switch 5/6 Amps
(c) One 5 Amps socket out let point controlled by one switch on SAME BOARD with other switches.
(d) One 5 Amps socket out let point on independent board controlled by one switch.
All as per item No.108 here in before but using pvc insulated unsheathed 2.5 sqmm cross sectional area FRLSH cable for phase/ neutral & for earth 2.5 Sqmm green PVC insulated FRLSH cable for 15 Amps socket point on independent board controlled by one switch.
Supply and fix in repairs Modular Switch flush type 6 Amps single pole, one way complete all as specified. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
S&F modular switch 2 way 6 Amp, 1 module complete all as specified and directed. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply and fix in repairs Modular Socket outlet, multi purpose, 5 Pin combined 6 Amps flush type complete all as specified. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply and fix in repairs Modular Bell push flush type, 6 Amps complete all as specified. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply and fix in repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socket complete all as specified. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply and fix in repairs Modular Switch 16 Amps single pole, one way complete all as specified. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply & fix in repairs Modular fan regulator step type, 2 module type complete. Make : Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS
Supply and fix in repairs Bell, ding dong type, AC 230 Volts, single pole complete.
S&F in repairs ceiling rose surface bakelite three terminal complete all as directed.
S&F in repairs lamp holder insulated body with back plate for batten fittings complete all as directed.
Supply and fix LED bulb of 7 watt, Of base B-22, suitable for fixing in lamp holder.
S & F for wall mounted LED tube light fitting 20 watts for surface mounted, anodized extruded aluminium housing, Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient high transmissitivity diffuser, high lumen ouput 230 volts and intregrated electronic driver connector block etc. complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : Havells Cat Part No. LHEXBLP7PN1W020 or its equivalent in Philips, Wipro.
S & F for LED 9/10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make : Havells Cat Part No LHEXACP7IN1W010 or its equivalent model in Wipro, Philips.
Supply and fix in repairs Wall light fittings suitable for & including LED bulb of 7 watt, including connection with all necessary fixing accessories complete all as specified and directed by Engr-in-Charge. Make : Havells Cat No. LHDL07150099 or equivalent in equivalent in Bajaj, Philips/ Crompton.
M&L for Sub main wiring in repairs with two runs of single core PVC insulated unsheathed FRLS cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm bore including one run of PVC insulated unsheathed 6.0 sqmm FRLS cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed.
Supply and fix in repairs double door SPN DBs eight ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete.
S & F in repairs MCB SPN 6 to 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F Single pole and neutral enclosure 230 V with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps all as specified and directed.
Supply and fixing LED street light (in building peripheri) fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp GI bracket, clamps, nuts, bolts grounded with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 Amps MCCB as incomer and SPN/ TP MCBs as out going, 4 way (Optium 1+12 Module) complete all as specified and directed by Engr-in-Charge.
S&F (in replacement) MCCB 4 pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 100 Amps rating, 16 KA breaking capacity complete
S&F modular TV socket as following :- (a) TV socket 1 module Make : Legrand Cat Part No 675546 - 01 Nos (b) Modular with plate for TV socket 1 No Make : Legrand Cat Part no 674517 (c ) Plastic flush boxes for 1 module jack Make : Legrand Cat Part no 673302 -01 Nos
S & F Rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipehooks etc.
Supply & fix plastic body exhaust fan, AC single phase 230/ 240 V of size 250mm sweep with louver, white in colour including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed. Make : Havells Model Ventil Air-DX White or equivalent in Crompton/ Almonard
Supply and lay XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade of size 35 sqmm 3.5 core, cross sectional area laid in trenches/ wall/ poles/ ducts/ pipes or through sleeve etc including connecting/ jointing with lugs and testing all as specified and directed by Engineer-in-Charge.
Supply laying and jointing GI pipe 'light grade' 50mm bore in trenches under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed by Engr-in-Charge.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed. (Note : Punned thickness of sand shall be measured)
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and as directed.
M&L for in repairs for Sub main wiring in repairs with two runs of single core FRLS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor FRLS drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm bore including one run of FRLS PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed.
M & L for earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised Iron Wire of size 4 sqmm as earthing lead by means of bolts, nuts, cheek nut and washers of galvanised iron or steel besides at all joints as shown in Electrical Plate No-3 of SSR Part-I and including excavation and earth work GI pipe 20mm bore light grade protection pipe and including chorcoal filling common salt, PCC 1:3:6 type CI using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 6mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm dia graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both ways with MS handle 12mm dia, CI funnel and wire mesh 20mm dia GI pipe medium grade for watering and connected to earth Test point (Including testing complete all as specified and directed).
Supply & fix in repair sheet metal enclousure box with a 3 pin (2 pin and earth) plug & socket complete with one MCB SP 20 Amps of breaking capacity 10KA, 'C' series, 240 volts complete all as specified and directed. Make : Cat Part No 810393 of Indo-Asian/ Bentec/ Havells.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .