Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹12.2 L+₹2.0 L (20.1%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹14.0 L+₹3.9 L (37.9%)Rejected-AOC NEAR RAM JANAKI HIGHER SECONDARY SCHOOL H NO 03 THAKURBAR DIMAPUR NAGALAND 797112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹9.9 L
EMD Value
₹19,900
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR AND REPLACEMENT OF PERIMETER LIGHTHS, SIGN BOARDS, NOTICE BOARDS, AWARENESS CHART AND REPAIR MAINT OF COOLING APPLIANCES AND ITS ALLIED WORKS AT ZAKHAMA MIL STN UNDER AGE (I) ZAKHAMA
2024_MES_659448_1
8263/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹19,900
3 Sept 2024
13 Jun 2024
18 Jul 2024
13 Jun 2024
16 Jul 2024
27 Jun 2024
Amount
Supply and fix energy saving high power LED Street light fitings complete of 90 W made up of pressure die cast aluminum housing with embeded PC cover having TOP Opening separate driver compartment with IP66 Protection including GI Pipe bracket made out of 40mm dia light grade pipe of length 1.2 Mtrs, bend to shape 120-130 degree and MS clamps made out of 25x3mm flat iron 2 Nos including nut and bolts for fixing the bracket and making connections in flexible counduit and taking out the existing fittings complete all as directed. Make-Havells/Bajaj/Philips/Crompton
Taking down defective street/ flood light/Perimeter lights fittings of any wattage from height upto 11metre pole for repairs and refixing the same,after removing the carbon/ deposit forein materials to make fuctional, replacing defective accessories like LED driver, SPD, PVC insluted sheathed copper conductor etc if required complete all as specified and as directed. (Note :For New spare parts/components of street light fittings shall be measured and paid separately under respective items as supply only however, screws, insulation sleeves, nuts, bolts, washers and PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmm X 3 core from light fitting to Street light feeder (max 1.5 metre ) deemed to be included in quoted rate.)
S&F in repairs aluminium cunductor, 1.5 sqmm, 2 Core for secuirty light connection as per relevent IS Code and complete all as speified and directed.
Supply only constant current LED driver suitable for LED luminaries of wattage of 90 Watt complete all as specified and as directed Make- Bajaj / Surya/ Havells / C&S
S & F in repairs HIGH GRADE METAL Emergency First Aid Kit Box/Emergency Medical Box/First Aid Box for Office/Wall Mountable, Multi Compartment (Metal) First Aid Kit (Sports and Fitness, Vehicle, Workplace) , complete all as specified and directed.
S & F in repairs cable junction box with necessary busbar and provision of incoming and outgoing cable 3 phase 4 core and fixing accesories, incl MCB SP 5 Amps ,complete all as specified and directed.
S&F in repair main entrance board with suitable fixing/ hanging arrangements/frame, made of High Quality Acralic Sheet Material of thickness 3 mm with Vinal cutting Red colour single side, Writing "NO ADMISSION EXCEPT ON DUTY" or as per format for notice board/awareness chart and as directed by Engr-in-Charge.
Taking down unserviceable Air-Conditioner split Type of any capacity and make from its existing location by disconnecting electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. (Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of split type AC are deemed to be included in the unit rate of the item.
Supply only hermetically/rotary type sealed compressor suitable for 1.5 TR split type Air conditioner. Note : Compressor oil for initial charging will be measured and paid separately
Supply only starting capacitor, paper impregnated of capacity 80/100 mfd AC 240 volts (for 1.5 Ton AC).
Supply only running capacitor, paper impregnated di-electric type of capacity 36-45 mfd AC 240 volt
Supply only thermostat switch to match with the existing Air conditioner of capacity 1.5 Ton
Supply only over load protector AC 230 volt single phase for 1.5TR AC (Make : Ranutrol/Sriram).
Supply and charging of compressor oil Make: Freezol/bajaj (Capila-D)
Supply only PCB (electronic control circuit board) of split type AC 1.5 TR capacity of (make:- carrier/voltas)
Taking out worn-out suction/discharge copper tube for Air-Conditioner and supply and fixing of new copper tube of appropriate quality and size to match in existing including jointing, brazing and testing complete all as specified and as directed by Engineer-in-charge suitable for split type ACs of 1.5 TR capacity.
Dismantling of unserviceable fan motor from the Air conditioner of 1.5 Ton capacity and re-winding of fan motor with existing gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing complete all as specified and as directed by Engr-in-Charge.
Supply and charging of refrigerant R-22 after vaccumaziming the system thoroughly, sealing and leak testing complete all as specified and as directed by Engineeer-in-charge.
S&F in Repair of insulation for copper tubes of Split type AC units,insulation type superion of sizen 3/8" diameter
S&F in Repair of insulation for copper tubes of Split type AC units,insulation type superion of sizen 5/8" diameter
S&F in repair Remote of any size and capacity of Split AC complete all as directed
Taking down parts of Refrigerator of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.
Supply only hermatically sealed compressor for refrigerator of capacity. Upto 310 Ltrs
Supply only open type relay as per existing one upto 310 Ltr capacity refrigerator.
Supply only thermostat switch to match with the existing item suitable for refrigerator of any capacity.
Supply only PCB (electronic control circuit board) of refrigerator upto 310 Ltrs
Supply only over load protector suitable for refrigerator to match with the existing design.
Taking down parts of Deep freezer of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.
Supply only hermatically sealed compressor for Deep freezer of capacity. Upto 425 Ltrs
Supply only open type relay as per existing one upto 310 Ltr capacity Deep freezer
Supply only thermostat switch to match with the existing item suitable for Deep freezer of any capacity.
Supply only over load protector suitable for Deep freezer to match with the existing design.
Taking down voltage stablizer and removing of burnt coil winding with new super enammeled copper winding as per existing gauge including varnishing drying alongwith replacement of unsv minor spares parts of voltage stablizer complete upto rating of 05 KVA reassembling complete all as speciied and directed.
Rameshwar Prasad
SHRIi Bachulal shah
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .