| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | ₹20.1 L Quoted ₹21.6 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹22.4 L+₹80,098 (3.71%)Rejected-Finance | ₹22.4 L+₹80,098 (3.71%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹24.1 L+₹2.5 L (11.5%)Rejected-Finance | ₹24.1 L+₹2.5 L (11.5%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹24.3 L+₹2.7 L (12.4%)Rejected-Finance | ₹24.3 L+₹2.7 L (12.4%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹25.6 L+₹4.0 L (18.3%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | ₹25.6 L+₹4.0 L (18.3%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
26 Jul 2023, 6:00 pmClosed
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN 226002 C/O 56 APO
REPAIR/ RENEWAL TO INTERNAL WIRING INCLUDING FITTINGS AND FIXTURE AT OFFRs MD ACCN AT GAUR ENCLAVE DILKUSHA THIMMAYA MARG RAK MARG KB ROAD CERTAIN ACCN AT SP MARG MG ROAD AND AT JCO/OR MD ACCN AT NIRBHAY VIHAR GE (WEST) LUCKNOW
2023_MES_606633_1
GE/W/LKO/29 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
Lucknow
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (WEST) LUCKNOW
₹68,000
Yes
1 Sept 2023
28 Jun 2023
28 Jul 2023
28 Jun 2023
26 Jul 2023
12 Jul 2023
28 Jun 2023 - 5 Jul 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc for taking credit and making good disturbed surfaces of walls, floors,etc. complete all as specified and as directed.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC(FRLS)insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and as directed.
All as per Item No 2 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 2 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
All as per Item No 2 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
All as per Item No 2 above but for One light point controlled by two way switch complete all as specified and as directed.
All as per Item No 2 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into and including suitable size surface conduit/casing caping, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and as directed.
All as per Item No 8 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 8 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
All as per Item No 8 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
All as per Item No 8 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn into existing conduit, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and as directed.
All as per Item No 13 above but for one 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 13 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
All as per Item No 13 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
All as per Item No 13 above but for One light point controlled by two 2 way switch complete all as specified and as directed.
All as per Item No 13 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm complete all as specified and as directed.
M & L for Point wiring complete with 1.5 sqmm PVC (FRLS) insulated stranded copper conductor single core cable drawn through existing rigid non metalic PVC conduit and conduit accesseries concealed in walls/ceiling, electrogalvanised pressed steel modular metal flush box 1/2 module to 8 module concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer along with white cover plate with plate up to 6 module for housing modular switches, and sockets 1.5 sqmm PVC insulated (green insulation copper conductor) earth continuity cable drawn with wiring and connected to common earth dolly complete all as specified and as directed.
All as per Item No 19 above but for one 5 Amp socket outlet point on an independent board complete all as specified and as directed.
All as per Item No 19 above but for one 5 Amp socket outlet point on the same board with other switch complete all as specified and as directed.
All as per Item No 19 above but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed.
All as item No 19 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board complete all as specified and as directed.
S & F switch piano flush button single pole one way 5 Amp 240 volt complete all as specified and as directed.
S & F switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and as directed.
S&F switch piano flush button single pole two way 5 Amp 240 volt complete all as specified and as directed.
S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and16 Amp, 230 volts complete all as specified and as directed.
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6Amp, 230 volts complete all as specified and as directed.
S&F fan regulator electronic,step up socket type,230 volt,125 W and conection complete all as specified and as directed.
S&F modular switches 1 way 6A,1 module complete all as specified and as directed.
S&F modular switches 1 way 16A,1 module complete all as specified and as directed.
S&F modular 6 A sockets-5 pin 2 module complete all as specified and as directed.
S&F modular 6A/16A sockets-3/5 pin combine 2 module complete all as specified and as directed.
S&F Modular white cover plate with frame 8 module complete all as specified and as directed.
S&F Modular white cover plate with frame 6 module complete all as specified and as directed.
S&F Modular white cover plate with frame 4 module complete all as specified and as directed.
S&F Modular white cover plate with frame 3 module complete all as specified and as directed.
S&F Modular white cover plate with frame 2 module complete all as specified and as directed.
S&F modular bell push single pole one way 6Amp,240 volt,1 module,fuesh type complete all as specified and as directed.
Supply and fix modular type blanking plates,1 module complete all as specified and as directed.
Supply & fix modular fan regulator 120/100 W, 2 Module for ceiling fan fixed, in board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and as directed.
S&F ceiling rose surface bakelite three terminal complete all as specified and as directed.
S&F bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed.
S&F call bell AC single pole 240 volt ding dongType complete all as specified and as directed.
S&F angle type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.
Supply & fixing bulk head light fitting made from cast aluminium body with heat resistance pressure die cast housing, IP-65 and IK 08 protection cover suitable for bulk head fitting integrated type 10/7W LED, 6500K , 100 lumens/watt including inbuilt electronic driver complete all as specified and as directed.
Supply and fixing wall/surface mounting luminaires (Mirror Light) integrated LED Batten( 2 feet) 10/12 W, 6500 K, 230V , minimum 100 lumens/watt,with extruded aluminium housing & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements complete all as specified and as directed. Makes shall be provided group-I cat as per latest approved make given by HQ CECC
Supply and Fixing wall/surface mounting luminaires integrated LED Batten 20/22 W, 6500 K,100 lumens/watt , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver, 25k burning hours ,2.5 KV surge protection complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S& F in repair Decorative wall light fixture made up of Metal base, synthetic white in colour and square/round metal base with bend pipe and glass globe with nickel finish, ( B-22/E27 base), with 01 No. 7/9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connecting arrangements all as specified and as directed. Make Phillips Model Grace / Bajaj / Havells decorative model Floretine WL 1LS B22 SS ( Note: Rates incl 01X 7/9 W LED Bulb with each fitting)
Supply and Fixing wall/surface mounting luminaires integrated LED Batten 20/22 W, 3000/4000 K,100 lumens/watt , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver, 25k burning hours ,2.5 KV surge protection complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements all as per specified and directed by Engr-in-charge Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S& F in repair Decorative wall bed light fixture made up of Metal base, synthetic white in colour and round metal base with bend pipe integrated LED type, 230 V, 3000K, complete incl all required electrical connecting arrangements all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repairs Flexiion 5 Mtr LED strip 22 W, 3000K/6000K as required on site with driver with wide viewing angle for good light distribution, easy to install complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S&F in repair LED Building security light 20/25 Watt with high power LED source (>100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S & F in replacement of GI pipe light grade, 32 mm bore, 1.20 mtr long bend in required shape, MS clamp 40x3mm thick duly painted with two coats of synthetic enemal paint fixed on wall including bolts and nuts complete all as specified and as directed.
S&F 30 W flood light LED fitting Warm/day cool as required, IP 65 protection, minimum 100 lumens/watt with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and as directed . Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S&F in repairs of surface type round LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S&F in repairs of surface type square LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in repairs of reccessed type square LED 10/12W downlighter 6500K 2.5 KV inbuit surg protection minimum 110 lumens/watt, 50k burning hours aliminium PDC complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
Supply and fixing LED lamp 9/12 watt, complete all as specified and as directed.
S&F in repair super bright LED (2X2), 36 W, 6500 K recess mounting minimum 100Lumens/watt IP20 ,IK02 PF>.9 and 4kv inbuilt surg protection with high efficent LED source complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
Supply and fixing in repair FTL fittings with decorative LED batten made up of aluminium casting 18/20 W of size complete standard fittings and fixtures including fixing on walls/roofs/ through MS downrod suspended type with fitting arrangement including neccessary elect connection from ceiling rose to luminaries with suitable size PVC cord complete all as specified and as directed. Make: HAVELLS with cat Part No. REGALBATTEN8UPTO1X22WDSBSWH //Philips cat part no. TMC100 1XTLED13-20WH/CROMPTON OR EQUIVALNT MAKE shall be provided group- I cat as per latest approved make given by HQ CECC
Supply and fixing in repair Material glass led tube ,voltage range 220-240v-50hz ,cct 6500k,lumen ,wattage 20/22W surge 2.5kv ,CRI 70 POWER FACTOR >_0.9 ,BURING HOURS 25K HOURS 110 L/W ,6000 K with high efficency, with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as specified and as directed. Note: Makes shall be provided group- I cat as per latest approved make given by HQ CECC
S&F LED 7/9 Watt LED emergency lamp 6500K automatically turns on AC to DC while power cut, inverter battery AC/DC (6 hrs Backup), rechargeable, cool white as required complete all as specified and as directed.
S & F in repairs integrated LED type Post top lantern with high power 25/30 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl neceesary electrical connection complete all as specified and as directed. Make: Havells Ruby clear with cat Part No.RUBYPT25WLED757PSYMTOPC / Bajaj ARIAN cat no BGCTN 25W LED WW / Halonix with cat part no. HLPT-01-30-CW
S & F in repairs integrated LED type Bollard , 10/12 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution incl LED driver complete and incl neceesary electrical connection complete all as specified and as directed. Note: Makes shall be provided group-I cat as per latest approved make given by HQ CECC
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and as directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn into existing conduit complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of earth wire.
Supply and fixing in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.
Supply and fixing in replacement for 2.5 sqmm single core copper, multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.
Supply and fixing in replacement for 4 sqmm single core copper, multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.
S & F three core PVC insulated FRLSH sheathed cable with 1.5 sqmm stranded copper conductor complete all as specified and as directed.
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed.
S&F sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and asdirected.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and as directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.
S&F MCB, single pole & neutral 32/40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, triple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.
Supply and fixing modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and directed by Engr-in-charge.
S&F MCCB 63-125 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and as directed.
Supply and fix wall mounting fans 400 mm (white) string controlled oscillating type including provn of flexible three core cable from ceiling rose to terminal for making connection, fitting on wall including all necessary fixing accessories complete all as specified and as directed .
S&F in replacement modular switches 1 way 6/10A,1 module. complete all as specified and as directed.
S&F in replacement modular switches 1 way 16A,1 module complete all as specified and as directed.
S&F in replacement modular pendent bed switches, 6A, 1 module complete all as specified and as directed.
S&F in replacement modular bell push ,1 module complete all as specified and as directed.
S&F in replacement modular 6 A sockets-2/3 pin combine 2 module complete all as specified and as directed.
S&F in replacement modular 6A/16A sockets-2/3 pin combine 2 module complete all as specified and as directed.
S&F in replacement fan step regulator modular 100/120W, 2 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame ,2 module complete all as specified and as directed.
Same as item ser No 92 hereinbefore but 3 module complete all as specified and as directed.
Same as item ser no 92 hereinbefore but 4 module complete all as specified and as directed.
Same as item ser no 92 hereinbefore but 6 module complete all as specified and as directed.
Same as item ser no 92 hereinbefore but 8 module complete all as specified and as directed.
Supply and fixing PVC casing and caping, 15mm wide complete all as specified and as directed
Supply and fixing PVC casing and caping, 20mm wide complete all as specified and as directed
S & F in replacement of switch piano flush button single pole one way 5/6 Amp 240 volt complete all as specified and as directed.
S & F in replacement of switch piano flush button single pole one way 15/16 Amp 240 volt complete all as specified and as directed.
S&F in replacement of socket outlet flush type multipurpose 2 in 1, 3 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and as directed.
S&F in replacement of unservicable socket outlet flush type multipurpose 2 in 1, 6pin 5 .Amp, 230 volts complete all as specified and as directed.
S&F in replacement of switch socket outlet combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and as directed.
S&F in replacement bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed.
S&F in replacement call bell AC single pole 240 volt ding dong Type. complete all as specified and as directed.
S&F in replacement high range, cordless call bell with wireless remote including batteries complete all as specified and as directed.
S&F in replacement angle/batten type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.
S&F in replacement PVC gang box fitted with and including piano type switch 5 A and socket 5 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.
S&F in replacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.
S & F rectangular laminated hylum sheet top cover for switch sockets of size' (125mmx125mmx3mm) complete all as specified and as directed.
Same as item 110 here in before but (200mmx125mmx3mm) complete all as specified and as directed.
Same as item 110 here in before but (225mmx275mmx3mm) complete all as specified and as directed.
M & L of Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and as directed .
S&F call bell AC single pole 240 Volt musical type Complete all as specified and as directed.
Shree Kanth Technologies
rajan construction
M/s PS Associates
M/S SHIVA CONSTRUCTION
Mangalam Trades
Mount International
VIDYA TRADERS
Unnati Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .