Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.7 CrAccepted-AOC NEW PROFESSOR COLONY PO DUMRI DIST BEGUSARI BIHAR PIN 851101 | DUMRI | BEGUSARAI | BIHAR | 851101 | ₹9.7 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹10.1 CrRejected-Finance | ₹10.1 Cr | L-2 | Rejected-Finance L-2 Bidder |
| 3 | L-3₹11.2 CrRejected-Finance | ₹11.2 Cr | L-3 | Rejected-Finance L-3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | M/s Jai Mangla Construction L3 | BPC INFRAPROJECTS PRIVATE LIMITED L2 | MATA JANKI CONCRETE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Total Amount of BoQ | ||||||
| 1.10 | Amount after unconditional Rebate | 1 | Nos | 0.79 ₹11.2 Cr | 1.21 ₹10.1 Cr | 0 ₹9.7 Cr |
Updated dates
Tender Value
₹10.8 Cr
EMD Value
₹21.6 L
Closing Date
9 Dec 2025, 2:30 pmClosed
AGM(C)/PU-Head Ranchi
252/c, Road No.1C, Ashok Nagar, Ranchi-834002
Supply and installation of IMWB, Construction of Panel building/service buildings and other ancillary works, General Electrical works, Yard lighting with other works etc in connection with KDH Railway siding of CCL-PKG-IV
2025_RITES_255092_1
03/OT/RITES/PU-RNC/KDH-CCL
Open Tender
Civil Works - Buildings
270 days
Dakra
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,700
RITES Ltd
₹21.6 L
30 Mar 2026
11 Nov 2025
10 Dec 2025
11 Nov 2025
9 Dec 2025
18 Nov 2025
Total Amount of BoQ
Amount after unconditional Rebate
Abstract Sheet of Percentage Rate Tender
BoQ_Ver3.0
NS-7 Supply and Installation of Submersible Water Motor Pump of adequate capacity along with electric panel and wiring complete. (Min 1 HP)
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Schedules
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE: Schedule-1, Estimate of EI Panel Cabin Building, EI Goomty Building and TMS & Weigh Bridge Building. (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Schedule-1, Estimate of EI Panel Cabin Building, EI Goomty Building and TMS & Weigh Bridge Building.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removale as per requirement, all complete for borewell of 150 mm dia
Providing and fixing M.S Clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (a) Earthe work in filling
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:3 (1 cement :3 coarse sand)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M30 grade with minimum cement content of 350 kg / cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level : Concrete of M30 grade with minimum cement content of 350 kg / cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top lay
er 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
15 mm cement plaster on rough side of single or half brick wall of mix(Internal plaster) : 1:6 (1 cement: 6 coarse sand)
Neat cement punning.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. New Work (Two or more coats) over and including water thinnable priming coat with cement primer having VOC Content iess than 50 gram/litre (Interior)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, tread & riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Kota stone slab flooring over 20mm(average) thick base laid over and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement morter 1:4 (1 cement: 4 course sand) 25 mm thick
Kota stone slab 20mm thick in risers of steps,skirtings,dado and pillars laid on 12mm(avarage) thick cement morter 1:3 (1cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing bolts including nuts and washers complete.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s spec
ification and direction of Engineer in- charge Extruded section profile size 42x50 mm
Providing and fixing to existing door frames. 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. : With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Anodized (AC 15) aluminium
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm diameter
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single pushfit Coupler
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door - 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door - 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° - 110mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) - 110mm shoe
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 75 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing white vitreous china pedestal type wa
ter closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.Brass pillar taps, 32 mm C.P. Brass waste coupling of of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia
Providing and fixing mirror of superior glass (of approved quality and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe
Supply of fire extinguishing equipments (ISI) Marked, Rubber mat (ISI marked), G.I. fire buckets filled with clean dry sand held on free standing steel stand, first aid box with medicine (ISI marked) and associated materials, shock treatment chart on aluminium frame, schematic diagram of HT/LT installation & transformer data on white hylem sheet with aluminium frame & fixing/ providing in the sub station area as per details in Explanatory notes.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS : 3989
Providing and fixing heel rest sanitary bend 100mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing single equal plain junction of required degree : 100x100x100 mm Sand cast iron S&S as per IS - 3989
Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 100 mm
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100 mm dia
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe
Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work i) 40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. i) 20 mm nominal outer dia Pipes
ii) 15 mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nomial bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 : 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mmnnominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. H D - 20 Circular shape 560 mm internal diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 600 mm dia. R.C.C. pipe
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore l
og, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (Slotted / Plain pipe) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge 150 mm nominal size dia 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (Slotted / Plain pipe) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge 150 mm nominal size dia 150 mm nominal size dia
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
NUMBER #
Metre
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
Any other unforeseen items which are not covered by the items of work under the above schedule-1 to 4 will be operated as per DSR-2023/DSR-E&M-2022 (Excluding GST). The Rate will be quoted in percentage (below (-)/at par/above(+))
NUMBER #
RVNL SOR Item No- 33015 (B)
RVNL SOR Item No-33015 ( C )
RVNL SOR Item No- 33057 (I)
RVNL SOR Item No- 33057 (III)
Schedule-3: General Electrical Work, Yard Lighting and other allied work
BOQ-5,Schedule-3: General Electrical Work, Yard Lighting and other allied work
BOQ-6,Schedule-4: General Electrical Work, Yard Lighting and other allied work (Non Schedule Items)
BOQ-7,Schedule - 5 : (Any other unforeseen item)
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Erection
Supplying and fixing su
itable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre-wired, LED fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Numbering of Ceiling Fan/Exhaust Fan/LED Fittings as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc.as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 8 way Double door , single pole and nutral steel sheet MCB distribution board 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Supplying and fixing 12 way Double door , single pole and nutral steel sheet MCB distribution board 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Supplying and fixing 4 way (4 + 12), Double door Horizontal Type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Supplying and fixing 6 way (6 + 12), Double door Horizontal Type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Supplying and fixing of 4 way (4 + 12), Double Door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 4 way (4 + 12), Double Door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing 40A rating, double pole, (single phase and neutral), 240 volts, RCCB, having a sensitivty current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, four pole, (three phase and neutral), 415 volts, MCB, RCCB, having a sensitivty current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm
4 X 35 sq. mm
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm
Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrule and other jointing materials, for 3C of 70 Sq. mm of 3 core, XLPE aluminium/ copper conductor cable of 11 KV grade as required.
Supply and making Outdoor cable end termiation with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3C of 70 Sq. mm of 3 core, XLPE aluminium/ copper conductor cable of 11KV grade as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supply of surface /wall mounted, LED batten type light fitting complete with LED Lamp with system wattage 18-22w suitable to work on 220-240V AC supply as approved by Engineer
Installation
Supply of 43-48 watt LED Street light fitting, pressure di-cast aluminium housing with suitable cover, suitable to work on 220-240V AC supply with system
Erection, Testing and Commissioning
Supply, Installation, testing and Commissioning of 1.5 Tonne split type AC, inverter type AC unit, complete with LCD display cordless remote, min 3 star energy rating, suitable for 1- Phase, 230 volts +10% AC supply including supply & installation of suitable rating, wall mounted, IC controlled electronic auto voltage corrector-
Installation, testing and Commissioning
Supply of 11-15 W LED lamp as approved by Engineer
Installation, Testing and Commissioning of 11-15 W LED
Supply of AC exhaust fan 300 mm 900 rpm with/ without louver shutters suitable for 1- phase, 230 Volts, AC supply system complete with capacitor, louver shutters, grouting bolts with nuts, making opening/ modification in the wall to suit the size of the fan, making good the damages, connections with 1.5sq. mm FR, PVC insulated, multi stranded copper conductor, single core/ three cable as instructed, earthing etc. as required:
Erection, Testing and Commissioning of AC exhaust fan 300 mm 900 rpm with/ without louver shutters suitable for 1- phase, 230 Volts, AC supply system complete with capacitor, louver shutters, grouting bolts with nuts, making opening/ modification in the wall to suit the size of the fan, making good the damages, connections with 1.5sq. mm FR, PVC insulated, multi stranded copper conductor, single core/ three cable as instructed, earthing etc. as required:
Supply of 4 C X 16 sqmm 1.1 kV grade, XLPE
insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Laying of 4 C X 16 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Supply of 4 C X 35 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Laying of 4 C X 35 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Supply of 4 C X 70 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Laying of 4 C X 70 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Supply of 4 C X 120 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Laying of 4 C X 120 sqmm 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes conforming to IS:7098-(Pt-I)-1998 or latest.
Trenching work for single cable (LT cable)
Trenching work for multiple cables (LT Cable)
Supply of 32 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Erection of 32 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Supply of 50 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Erection of 50 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Supply of 100 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Erection of 100 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Supply of 150 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Erection of 150 mm dia GI pipe - class 'B' ISI marked with accessories including bends etc. for support of cable with erected pole/ recessing in wall/ floor/ passing earth strip OR passing cable as required:
Supply of 100 kVA 11 KV/440 V , 50 HZ , out door type, Delta/Star connected, copper wound, DYn11, ONAN cooled, power distribution transformer (outdoor type) conforming to IS:1180 (Energy Efficiency level shall not be less than–II), complete with all accessories and first filling of oil as required.
Installation, testing and commissioning of 100 KVA ,11 KV/440 V , 50 HZ , out door type Delta/Star connected, copper wound, DYn11, ONAN cooled, power distribution transformer.
Providing fencing/ enclosure for above item i.e. 14 Nos 100 KVA Tranformer.
Construction of foundation for 2 Nos 100 KVA transformer installation as required as per OEM Design/ Drawing (Grade M-15).
Supply of 3 pole, 11 kV, 400 amps, gang operated switch complete with drop out fuses etc. as required.
Erection, testing & commissioning of 3 pole, 11 kV, 400 amps, gang operated switch as required.
Supply of 3 pole, 11 kV, 400 amps, gang operated switch complete with drop out fuses etc. as required.
Supply of 3 Core,70 sqmm, 11KV(E) XLPE insulated, armoured, aluminium conductor HT cable as required.
Supply of 3 pole, 11 kV, 400 amps, gang operated switch complete with drop out fuses etc. as required.
Laying of 3 Core,70 sqmm, 11KV(E) XLPE insulated, armoured, aluminium conductor HT cable as required.
Trenching work for cable (HT Cable)
Supply, of weather proof LT feeder pillar 63Amp comprising of the items indicated as under ; (i) incoming MCCB 63A, 4 pole, 35kA, fixedtype (Ics=100%Icu) - 1 No ii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type(Ics=100%Icu) - 4 Nos iii) Outgoing MCB double pole, 40A,10kA-2Nos iv) Outgoing MCB Single pole, of 40 A, 10kA- 4Nos v) Sleeved/Epoxy coated copper bus-bar200 A in bus bar Chamber vi) Indication lights.
Installation, Testing & Commissioning
Supply, of weather proof LT feeder pillar 125 Amp comprising of the items indicated as under i) incoming MCCB 125A, 4 pole, 35kA (Ics=100%Icu) - 1 No ii) Outgoing MCCB 63A, 4 pole, 25kA (Ics=100%Icu) - 4 Nos iii) Outgoing MCB 40A, 4 pole, 10kA - 4 Nos iv) Outgoing MCB 32A, DP, 10kA, 4Nos v) Outgoing MCB Single pole 32A, 10kA-4Nos vi)Modular digital time switch and 3 phase contactor 63 A - 2 Set vii) Sleeved/Epoxy coated copper busbar 250A in bus bar Chamber viii) Indication lights.
Supply and making Outdoor cable end termiation with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3C of 70 Sq. mm of 3 core, XLPE aluminium/ copper conductor cable of 11KV grade as required.
Supply, of weather proof LT feeder pillar 250 Amp comprising of the items indicated as under i) Incoming MCCB 250 A, FP 35kA (Ics=100%Icu) Fixed Type - 1 No ii) Outgoing MCCB 125 A, FP 35kA (Ics=100%Icu) Fixed Type - 2 Nos iii) Outgoing MCCB 63 A, FP 25kA (Ics=100%Icu) Fixed Type - 4 Nos iv) Outgoing MCB 40 Amps, FP, 10kA - 4 Nos v) Outgoing MCB 32 Amps DP 10 KA - 4 Nos vi) Outgoing MCB Single pole 32A, 10kA -4 Nos vii) Modular digital time switch and 3 phase contactor 63 A - 2 Set viii) Sleeved/Epoxy coated copper bus-bar 400 A in bus bar Chamber. ix) Indication lights.
Supplyof 5 mtr of G.I Octagonal pole including digging of pit, making foundation with cement, sand & concrete in ratio 1:2:6, muffing, accommodating G.I pipe in foundation for cable loop-in-loop out.
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
Quintal
NUMBER #
PRICE SCHEDULE: Schedule - 2 : (Non- Schedule item/in-motion Weigh Bridge ) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NS-1 Design, manufacturing,Supplying, installation, calibaration, testing & commissioning of 140T pitless Electronics In-motion Rail Weigh bridge including freight charges, insurance, along with computers, printer, UPS, Digitizer etc Complete in all respect as per latest RDSO specification.
PRICE SCHEDULE -Schedule-4: General Electrical Work, Yard Lighting and other allied work (Non Schedule Items) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Schedule-4: General Electrical Work, Yard Lighting and other allied work (Non Schedule Items)
NS-1 Supply, erection, testing and commissioning of 30 mt High Mast tower along with feeder pillar box consisting with astronomical timer, aviation obstruction light, earthing (2no) with earthing connector by 25x5 mm GI earth strip as per specification. Supply
NS-2 Erection, testing & commissioning
NS-3 Supply & construction of RCC foundation with M-20 grade concrete by considering soil bearing capacity as 5 Ton per sq mt.
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
NS-4 Supply of 350W/400W LED 5700K-6500K flood light luminaires of eficaccy > 110 Lm/watt for a high watage luminaries with constant current electronic driver set consisting with 4 kV surge protection for internal and 10 kV surge protection for external.
NUMBER #
NS-5 Erection, testing and commissioning of 350W/400W LED 5700K-6500K flood light luminaires
NS-6 Preparation of building wiring diagram showing Incoming & Outgoing distribution circuit & all switch boards, electrical gadget in the buiding including as erected drawings.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD03OT.pdf
Tender Documents • 5.01 MB
Drg03OT.pdf
Other Document • 1.60 MB
BOQ_293852.xls
BOQ • 0.72 MB
Download all tender documents and submit your bid