| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAdmitted-Finance SIRSA | ₹9.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹10.0 Cr+₹29.8 L (3.06%)Admitted-Finance | ₹10.0 Cr+₹29.8 L (3.06%) | L2 | Admitted-Finance |
| 3 | L3₹10.3 Cr+₹54.6 L (5.60%)Admitted-Finance 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹10.3 Cr+₹54.6 L (5.60%) | L3 | Admitted-Finance |
| 4 | L4₹11.2 Cr+₹1.5 Cr (15.0%)Admitted-Finance PLOT NO 44 54 5 59 3 SURVEY NO 169 DHOOLAPALLY VILL IDA JEEDIMETLA MEDCHAL MALKAJGIRI HYDEARBAD TELANGANA 500055 | MEDCHAL MALKAJGIRI | TELANGANA | 500055 | ₹11.2 Cr+₹1.5 Cr (15.0%) | L4 | Admitted-Finance |
| 5 | L5₹11.6 Cr+₹1.9 Cr (19.0%)Admitted-Finance | ₹11.6 Cr+₹1.9 Cr (19.0%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Shree Gautam Construction Co. Ltd. L3 | Mechfab engineering industries pvt ltd L2 | BDS PROJECTS L6 | M/s. Shivji Singla and Sons L1 | BUILDRITE CONSTRUCTION L5 | NRE INDUSTRIES LLP L4 |
|---|---|---|---|---|---|---|---|---|---|
| 10.00Design and Detailing (2% of the overall quoted value which will be automatically loaded in the Total Amount cell- BA225, for details refer SCC.) Design, detail engineering, planning and preparation of shop drawings, plan & elevation drawings, vetting and proof checking of the structural design of the warehouses and ground investigation report. All documents to be approved by any Indian Institute Technology (IIT)/National Institute of Technology (NIT) prior to start of construction at site. Preparation and submission of Construction Drawings and soil reports are not limited to the following in three sets along with a copy of the same in soft (in .dwg and .tekla format, editable) form in CD. 1. Detailed soil investigation report. 2. Structural analysis report (using Tekla Software). 3. Architectural drawings (using Softwares like AutoCAD/Sketchup/Lumion). 4. Detailed Shop drawings for structural fabrication. 5. Detailed Structural drawings (RCC and Steel) like- i. Layout of Footings & tie-beams, pedestal, columns, etc ii. Plan, Sections, Elevations of the warehouse. iii. External wall details, internal partition wall details. iv. Door Window Details, louver details. v. Detailed Room layout. vi.Plumbing & Sanitary Layouts (internal & External). vii. Landscape and hardscape layout and design viii. Electrical layout ix. Modular Electrical Provisions Such as Electrical Circuits, Wiring, Electrical Fittings, Fixtures Panels Service lines. Note- Successful agency to provide documents other than the above mentioned documents as necessary for successfull completion of the project as per the directions and advice of Engineer-in-charge. Read in conjunction with Section 9.3 of SCC. | |||||||||
| 20.00Civil Works | |||||||||
| 20.00 | Demolition of RCC Work
Demolition of RCC WORK including stacking of serviceable materials and disposal of un-serviceable materials at suitable locations within/outside the Refinery Area as advised by EIC (including above ground and foundation). Dismantling of existing structures like culverts, bridges, retaining walls, drains, trenches, and other structure comprising of masonry, cement concrete, including Tools and Machineries and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 500 m outside Pragati Dwar exit gate (By mechanical means) (Reinforced Cement Concrete of all Mix grades) | 20 | M3 | 4,500 ₹90,000 | 2,100 ₹42,000 | 4,000 ₹80,000 | 4,500 ₹90,000 | 5,000 ₹1,00,000 | 2,000 ₹40,000 Lowest |
| 20.00 | Demolition of Road Work
Demolition of ROAD WORKS including stacking of serviceable materials and disposal of un-serviceable materials at suitable locations within/outside the Refinery Area as advised by EIC | 50 | M3 | 450 ₹22,500 Lowest | 500 ₹25,000 | 5,000 ₹2,50,000 | 4,500 ₹2,25,000 | 1,000 ₹50,000 | 1,400 ₹70,000 |
| 20.00 | Taking Out and Stacking of Pavers
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. | 4,200 | M2 | 75 ₹3,15,000 | 100 ₹4,20,000 | 500 ₹21,00,000 | 500 ₹21,00,000 | 100 ₹4,20,000 | 40 ₹1,68,000 Lowest |
| 20.00 | Laying of Old Pavers
Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). | 2,000 | M2 | 110 ₹2,20,000 Lowest | 500 ₹10,00,000 | 500 ₹10,00,000 | 350 ₹7,00,000 | 200 ₹4,00,000 | 250 ₹5,00,000 |
| 20.00 | E/W from Grade Level upto 1.5 m
Earth work in machine excavation below ground level in all kind of Soil for all kind of works in foundation including pipe / cable trenches, pavements, manholes, footings, pipelines, pipe sleepers, drains, UG pits etc. including all labour, materials, dressing of sides, leveling, grading and ramming of bottom, pumping & bailing out water accumulated due to rain and/ or subsoil waters by any method including well point system if required and including disposal or stacking, leveling and neatly dressing as directed by Engineer-in-Charge, Keeping of surplus excavated material within a lead of 500 M etc. including dismantling and providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., including shoring/ strutting if required, all materials tools, tackles and labour all complete and as directed by Owner/Engineer-in-Charge for following depth: from Grade Level upto 1.5 m
Excluded: General Filling, General Excavation in Hard Rock, Disposal of Earth to designated Areas
Note: Payment for Excavation shall be made on PCC Foot Print Area basis | 1,980 | M3 | 250 ₹4,95,000 Lowest | 301 ₹5,95,980 | 400 ₹7,92,000 | 350 ₹6,93,000 | 450 ₹8,91,000 | 260 ₹5,14,800 |
| 20.01 | E/W from 1.5 m to 3 m
All activities & scope same as in Sl no. 60 but for excavation below 1.5 M and upto 3 M below existing ground level. | 1,980 | M3 | 350 ₹6,93,000 | 340 ₹6,73,200 | 450 ₹8,91,000 | 350 ₹6,93,000 | 500 ₹9,90,000 | 325 ₹6,43,500 Lowest |
| 20.01 | Manual Excavation upto 1.5 m
Earthwork in excavation: Earth work excavation in Manual Mode below
ground level in all kind of Soil for all kind of works in foundation including pipe/ cable trenches, pavements, manholes, footings, pipelines, pipe sleepers, drains, ug pits etc. including all labour, materials, dressing of sides, leveling, grading and ramming of bottom, pumping & bailing out water accumulated due to rain and/ or subsoil waters by any method including well point system if required and including disposal or stacking, leveling and neatly dressing as directed by Engineer-in-Charge, keeping of surplus excavated material within a lead of 500 M etc. including dismantling and providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., including shoring/ strutting if required, all materials tools, tackles and labour all complete and as directed by Owner/Engineer-in-Charge for following depth: from Grade Level upto 1.5 m
Excluded : - General Filling, GeneralExcavation in Hard Rock, Disposal of Earth to designated Areas
Note: Payment for Excavation shall be made on PCC Foot Print Area basis | 50 | M3 | 450 ₹22,500 Lowest | 650 ₹32,500 | 800 ₹40,000 | 500 ₹25,000 | 1,000 ₹50,000 | 700 ₹35,000 |
| 20.01 | Manual Excavation from 1.5 m to 3 m
All activities & scope same as in Sl no. 80 but for excavation below 1.5 M and upto 3 M below existing ground level. | 50 | M3 | 600 ₹30,000 | 850 ₹42,500 | 1,000 ₹50,000 | 1,000 ₹50,000 | 1,250 ₹62,500 | 400 ₹20,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹22.9 L
Closing Date
12 Sept 2025, 11:00 amClosed
Madhu Kiran Dyavanapelly 9700022443
Numaligarh Refinery Limited
Design, Detail Engineering and Construction of 02 nos. of Pre-fabricated Warehouses for Storing Mandatory Spares at NRL, Numaligarh
2025_NRL_875370_1
OC10000525/MK
Open Tender
Warehouse
Works
300 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹22.9 L
Yes
As per tender
4 Nov 2025
30 Aug 2025
13 Sept 2025
30 Aug 2025
12 Sept 2025
30 Aug 2025
4 Sept 2025
Design and Detailing (2% of the overall quoted value which will be automatically loaded in the Total Amount cell- BA225, for details refer SCC.) Design, detail engineering, planning and preparation of shop drawings, plan & elevation drawings, vetting and proof checking of the structural design of the warehouses and ground investigation report. All documents to be approved by any Indian Institute Technology (IIT)/National Institute of Technology (NIT) prior to start of construction at site. Preparation and submission of Construction Drawings and soil reports are not limited to the following in three sets along with a copy of the same in soft (in .dwg and .tekla format, editable) form in CD. 1. Detailed soil investigation report. 2. Structural analysis report (using Tekla Software). 3. Architectural drawings (using Softwares like AutoCAD/Sketchup/Lumion). 4. Detailed Shop drawings for structural fabrication. 5. Detailed Structural drawings (RCC and Steel) like- i. Layout of Footings & tie-beams, pedestal, columns, etc ii. Plan, Sections, Elevations of the warehouse. iii. External wall details, internal partition wall details. iv. Door Window Details, louver details. v. Detailed Room layout. vi.Plumbing & Sanitary Layouts (internal & External). vii. Landscape and hardscape layout and design viii. Electrical layout ix. Modular Electrical Provisions Such as Electrical Circuits, Wiring, Electrical Fittings, Fixtures Panels Service lines. Note- Successful agency to provide documents other than the above mentioned documents as necessary for successfull completion of the project as per the directions and advice of Engineer-in-charge. Read in conjunction with Section 9.3 of SCC.
Civil Works
Demolition of RCC Work Demolition of RCC WORK including stacking of serviceable materials and disposal of un-serviceable materials at suitable locations within/outside the Refinery Area as advised by EIC (including above ground and foundation). Dismantling of existing structures like culverts, bridges, retaining walls, drains, trenches, and other structure comprising of masonry, cement concrete, including Tools and Machineries and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 500 m outside Pragati Dwar exit gate (By mechanical means) (Reinforced Cement Concrete of all Mix grades)
Demolition of Road Work Demolition of ROAD WORKS including stacking of serviceable materials and disposal of un-serviceable materials at suitable locations within/outside the Refinery Area as advised by EIC
Taking Out and Stacking of Pavers Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Laying of Old Pavers Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost).
E/W from Grade Level upto 1.5 m Earth work in machine excavation below ground level in all kind of Soil for all kind of works in foundation including pipe / cable trenches, pavements, manholes, footings, pipelines, pipe sleepers, drains, UG pits etc. including all labour, materials, dressing of sides, leveling, grading and ramming of bottom, pumping & bailing out water accumulated due to rain and/ or subsoil waters by any method including well point system if required and including disposal or stacking, leveling and neatly dressing as directed by Engineer-in-Charge, Keeping of surplus excavated material within a lead of 500 M etc. including dismantling and providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., including shoring/ strutting if required, all materials tools, tackles and labour all complete and as directed by Owner/Engineer-in-Charge for following depth: from Grade Level upto 1.5 m Excluded: General Filling, General Excavation in Hard Rock, Disposal of Earth to designated Areas Note: Payment for Excavation shall be made on PCC Foot Print Area basis
E/W from 1.5 m to 3 m All activities & scope same as in Sl no. 60 but for excavation below 1.5 M and upto 3 M below existing ground level.
Manual Excavation upto 1.5 m Earthwork in excavation: Earth work excavation in Manual Mode below ground level in all kind of Soil for all kind of works in foundation including pipe/ cable trenches, pavements, manholes, footings, pipelines, pipe sleepers, drains, ug pits etc. including all labour, materials, dressing of sides, leveling, grading and ramming of bottom, pumping & bailing out water accumulated due to rain and/ or subsoil waters by any method including well point system if required and including disposal or stacking, leveling and neatly dressing as directed by Engineer-in-Charge, keeping of surplus excavated material within a lead of 500 M etc. including dismantling and providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., including shoring/ strutting if required, all materials tools, tackles and labour all complete and as directed by Owner/Engineer-in-Charge for following depth: from Grade Level upto 1.5 m Excluded : - General Filling, GeneralExcavation in Hard Rock, Disposal of Earth to designated Areas Note: Payment for Excavation shall be made on PCC Foot Print Area basis
Manual Excavation from 1.5 m to 3 m All activities & scope same as in Sl no. 80 but for excavation below 1.5 M and upto 3 M below existing ground level.
Carriage of Materials upto 3 KM Carriage of Materials by mechanical transport including loading, unloading and stacking: Earth Upto 3 KM
Carriage of Materials 3<=5 KM Carriage of Materials by mechanical transport including loading, unloading and stacking: Earth from 3 KM to upto 5 KM
Material Shifting Engagement of unskilled workers for miscellaneous activities.
Backfill with Borrowed Earth Backfill with material supplied by contractor: Backfilling around foundations, plinth, trenches etc to proper grade and level with approved borrow pits (arranged by Contractor) including cost of backfill material along with all royalties/taxes etc. loading, transporting from all leads and lifts and laying at all depths/ heights in layer of 200 mm loose thickness, watering and ramming to proper compaction to achieve 95% maximum proctor density, dressing etc all complete and as per directions of Engineer-in-Charge. (Compacted thickness shall be considered for volume of works measurement and payment)
Backfill with Sand Backfill with Sand Supplied by Contractor: Supplying and filling SAND from Approved source of specified quality under floors, in foundations, plinths, tank foundations, cable trench etc. for all depths and heights including cost of sand,royalties, transportation to site for all leads and lifts,including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm,watering,ramming,compacting with mechanical compactors and/or other equipment to the specified levels to achive 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope,providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge.The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete
Anti Termite Treatment Providing and injecting approved chemical emulsions as specified for pre constructional Anti Termite Treatment and creating a chemical barrier under and around column pits, wall trenches, basement excavations, top surfaces of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints. surrrounding of pipes and conduits etc. all complete as specified and directed (Plinth area of the building at ground floor only shall be measured).
Water Proof Lining Providing and laying 40 mm thick Damp Proof Course on plinth level with plain cement concrete of grade M20 with 10mm & down size graded crushed stone aggregates. integral water proofing compound conforming to IS:2645 shall be mixed with concrete, placed in two layers of 20mm thick with two coats of hot bitumen (Grade A90 / S90 conforming to IS:73) applied @1.7 Kg/sq.m. over each layer as per specifications including cleaning, watering the top surface of walls, centering, shuttering, placing, tamping. curing, sprinkling an even layer of dry & sharp sand over the hot bitumen etc. all complete as specified and directed.
Plinth Protection Providing and laying plinth protection around the building perimeter including shuttering and excluding reinforcement consisting of a layer of 150mm thick compacted sand and 100mm thick of M20 grade concrete top layer, laid to slope including tools & labor, excavation, disposal of surplus earth, trowel finishing the top layer, curing etc. all complete as specified in the Drawings, specifications and directions of Engineer-in-charge. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope.
PCC - M10 Supplying, mixing, placing in position, plain cement concrete of M10 grades as per IS:456 under foundations, floors, plinth beams etc. including compaction by vibration, curing, using 20mm /40 mm down aggregate all per sec 2 of tech-spec. but excluding form work and reinforcement.The rate shall include all tools, tackles, labours, consumables etc.
RCC - M30 Supplying, mixing, placing in position RCC of grade M30 using 20 mm down coarse aggregate as per IS:456 in foundations,beams, plinth beams, columns, portals, slabs, walls, curved walls, retaining walls, pedestals, including compaction, vibration, curing and finishing all but excluding form work and reinforcement. All from foundation level to top of plinth level. The rate shall include all tools, tackles, labours, consumables etc.
RCC - M30, above plinth level All activities & scope same as in Sl no. 210, but from above plinth level and upto +6 m level
F/W Centering & shuttering, Substructure Providing and fixing Centering & shuttering Plywood Shuttering / Steel Plate Shuttering in foundations, footings, raft, beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/ machine foundations, pedestals, abutments, pipe sleepers, culverts, drains, pipe way bridges, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels / bunkers / silos / shafts / hoppers / liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting. bracing, propping etc., keeping the same in position during Concreting and removal of the same after specific period etc. for Straight / Inclined Shuttering, keeping necessary provisions for Inserts, Projecting Dowels, Anchor Bolts or any other Fixture, tools, equipments and labour necessary for the work,etc., all complete and as specified and directed.
F/W Centering & shuttering, Superstructu All activities & scope same as in Sl no. 230, but for superstructures, all heights above plinth level
HYSD TMT bars for substructures High Yield Strength Deformed (HYSD) / TMT Bars #Grade Fe 500D for # Cast-in-Situ/Pre-cast Sub Structures: Supplying, Cleaning and placing in position TMT bars / High Yield Strength Deformed Steel Bars Reinforcement of Grade Fe 500D conforming to lS:1786, for RCC work (Cast-in-Situ and/ or Pre-cast Reinforced Concrete Works) Including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all Sub Structures like Foundations, Culverts, Basins, Drains, Sleepers, etc. at all depths as specified in the Drawings, Annexure IV to SCC and all completed as per directions of EIC. Materials to be supplied as per approved vendor lists attached with special conditions of contract. Supply of all material in contractor's scope. Measurement: Weight calculated as per the approved BBS. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used. Wastages & unauthorized laps shall not be considered for payment. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope.
HYSD TMT bars for superstructures All activities & scope same as in Sl no. 250, but for superstructures, all heights above plinth level
Brick Work in Substructure Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Full Brick Work in Superstructure Providing and constructing 230mm or more thick masonry with locally available approved quality Fly ash bricks having minimum crushing strength 35 Kg/Sq. cm and water absorption maximum 20% in cement mortar CM 1:6 (1 cement : 6 Sand) mixed with approved non-shrinking compound as per manufacturer's instruction in specified courses of approved bond and including raking out joints, curing, doing independent double legged scaffolding, all complete as per specifications etc. at all heights, depths and leads all as directed by EIC to satisfaction.
Half Brick Work in Superstructure Providing and constructing half brick (115mm thick) masonry with locally available approved quality Fly ash bricks having minimum crushing strength 35 Kg/Sq. cm and maximum water absorption 20%, in cement mortar CM 1:4 (1 cement : 4 Sand) mixed with approved non-shrinking compound as per manufacturer#s instruction in specified courses of approved bond and including providing RCC patli beam of 115mm x 100mm at every 1.00m c/c with 2 nos. 8 mm dia Tor bars and 6 mm dia links at 300 c/c in cement concrete of mix M 20, required formwork complete with raking out joints, curing, doing independent double legged scaffolding as per specifications etc. at heights and leads all as directed by PM to his entire satisfaction. (Patli beam is part of the item)
12 mm Plaster Providing and applying 12 mm thick smooth cement plaster with waterproofing compound conforming to IS-2645 (CICO/ approved equivalent) at all heights and below plinth in CM fine sand 1:4 to walls, beams, column, drain, bends, moulds, grooves, pattas and drip course to all brick and RCC surfaces including raking joints, scaffolding, curing finishing smooth including cost of cement, cleaning, hacking concrete surfaces, scaffolding, providing drip moulds, pointing if required, watering, curing etc. complete for all heights. Also providing and fixing 20 gauge GI chicken mesh @150 mm wide to junctions of concrete and masonary.
20 mm Plaster Providing and applying 20 mm (12mm + 8 mm) thick smooth cement plaster with waterproofing compound conforming to IS-2645 (CICO/ approved equivalent) at all heights and below plinth in CM coarse sand 1:4 to walls, beams, column, drain, bends, moulds, grooves, pattas and drip course to all brick and RCC surfaces including raking joints, scaffolding, curing finishing smooth including cost of cement, cleaning, hacking concrete surfaces, scaffolding, providing drip moulds, pointing if required, watering, curing etc. complete for all heights. Also providing and fixing 20 gauge GI chicken mesh @ 150 mm wide to junctions of concrete and masonary. Including providing grooves in plaster as specified in drawings and specifications and as directed by Engineer-in-charge.
Wall Putty Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Prime Coats Applying priming coats with primer of approved brand and manufacture, with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Acrylic Emuslion Paint Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour: Two Coats
Exterior Paint Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Vitrified Tile in Flooring & Skirtng Providing and Laying Vitrified Tiles in Flooring and Skirting of Approved Shape, Size and Shade confirming to IS:770 and including cost of Tile cutting, providing a 30 mm thick bedding in cement mortar 1:4 mix, providing a coating of adhesive as per manufacturer’s specifications, flush pointing and filling of joints with cement slurry (using white cement), providing the pigment confirming to IS:2114, Table 1 matching the shade of the tiles, finishing, curing, protecting the surface with POP till final handing over etc. all complete as per drawings, specifications and as directed by Engineer-in-charge. for coloured glazed vitrified tiles of size 600 mm x 600 mm x 8 mm thick to be used in Flooring
Vitrified Tile in Dadoing All activities same as Sl no 360 but for dadoing
Tremix Vaccum dewatered flooring Supply and laying Tremix Vaccum dewatered concrete flooring M30 (150 mm thick), providing & sprinkling synthetic, nonmetalic, high-abrasion resistant floor-hardener POLYABRES of FOSROC, M/s Sunanda Speciality Coatings Pvt. Limited or equivalent, while the base-conceret is about to set and the bleeding water appears over the surface, at 3 to 5 kg/m2 (excluding concrete) and finished with trowel as per requirement. Allow to set for 24 hours and proceed with regular concrete curing specification. Light foot traffic may be allowed after 24 hours etc, including cutting of grooves 5 mm wide and one-third the thickness of the concrete, subsequently filled with a sealant equivalent to Polysulphide all complete as per satisfaction of Engineer in Charge. The rate shall include all tools, tackles, labours, consumables etc.
PU Coating Providing and applying PU based Car deck protection system (Masterseal Traffic 1331 of M/s. BASF or equivalent approved) consisting of followings - (a) Cleaning the surface of the slab, making it absolutely free from dust, oil or any type of deleterious materials etc., and chipping off the loosely adhered mortar. The cleaning and preparation of the RCC surface must be carried out thoroughly to leave a sound base for the application. Release oil and other contaminants shall be removed prior to the application of the primer. use of surface grinder is must. Surface must be fully dry before application. (b) Applying MasterSeal P 2525 or equivalent, a two component solvent free primer based upon epoxy resins for use with appropriate resin overlays and coatings to improve their adhesion to existing concrete substrate. Consumption rate : 0.4 kg/m2. (c) Applying MasterTop SRA 3 or equivalent, graded, high purity quartz aggregate with a particle size in the range 0.3#0.9mm. Consumption Rate: 0.6 kg/m2. (d) Applying MasterSeal TC 242 or equivalent, Solvent free two component Polyurethane coating for traffic decking application suitable for application as a topcoat on traffic deck systems. Consumption : 0.7 - 0.8 kg/m2. (e) Applying MasterTop SRA 3 or equivalent, a graded, high purity quartz aggregate with a particle size in the range 0.3#0.9mm. Consumption Rate : 0.3 - 0.4 kg/m2. (f) Applying MasterSeal TC 268 or equivalent, 2K-PU top coat, high solids, pigmented, UV stable, for broadcasted outdoor car parking systems. All complete as per specifications of approved manufacturer and satisfaction of the EIC.
Aluminium work for fixed portion Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron)
Aluminium work for shutters All activities & scope same as in Sl no. 400, but for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Dash Fasteners Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mm
Particle board Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of EIC. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Glazing Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Hinges Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete: 100X58X1.90 mm
Sliding Bolts Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
Tower Bolts (200x10 mm) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm
Tower Bolts (150x10 mm) All activities & scope same as in Sl no. 470, but for 150x10 mm
Aluminium Handles Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Door Stoppers Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
False Ceiling Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm,cross-T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge.With 15 mm thick regular edged light weight calcium sliciate false ceiling tiles
PVC Pipe 100 mm Dia Includes but not limited to Supplying, delivering to site and fixing rain water down take pipe of Cast Iron / PVC Materials with holder / clamps / elbows / accessories, including cost of all materials, fixing to column / wall, scaffolding, jointing etc with all tools, labour and materials necessary to complete the work as per drawings and as directed. Cast Iron Pipes shall be as per IS 1729. PVC Pipes shall be Class 2 Pipes with a pressure rating of 4kg/m2 as per IS 4985. Brackets shall be of wrought iron clevis type, lip ring type or perforated strap iron type. roof drain head shall be dome type. Length installed shall be measured as per IFC drawings
Rolling Shutter Rolling shutter: mechanically operated from both inside and outside by reduction gear type mechanism. Supplying and fixing in position 18 SWG mild steel push and pull type rolling shutters, conforming to IS: 6248 including tools, labour, all accessories like shutter (constructed with inter locking lath sections formed out of cold rolled steel strips 0.9mm thick, 80mm wide and 1.25mm thick, 80mm wide respectively for shutter width up to 3.5M and above 3.5M), jointless M.S. channel section for guide (min. 3.15mm thick), M.S. girders, pressed bottom rails, shutter suspension stud shaft with pully and cage with cowl, top rolling springs, locking arrangement and all fittings and accessories as per approved manufacturers drawings, painting with two coats of synthetic enamel of approved make & shade over a coat of approved quality red oxide zinc chromate primer, making good of all damaged surfaces etc. all complete and as directed. Make: DynaKavach or equivalent.
Under deck insulation Supply and installation of Closed Cell Elastomeric Nitrile Rubber insulation with all fitting accessories like adhesive, mesh, etc conforming to IS 14164 and relevant international standards (EN, ASTM, BS, UL, FM, RoHS, GreenGuard, EPD etc.), with thermal conductivity ≤ 0.035 W/m-K at 0°C mean temperature, moisture diffusion resistance factor (µ) ≥ 7,000 without external barrier, water absorption by volume < 0.2%, density 40–55 kg/m³, and service temperature range −50 °C to +85 °C. Material shall have fire performance meeting Class O/1, UL 94 V0/HB, and FM approval, be dust and fibre free, formaldehyde free, CFC & HCFC free, ROHS compliant, with ODP and GWP of zero, and possess GreenGuard Gold Certification and Environmental Product Declaration approval. Thickness shall be as specified for each application, and installation shall be carried out strictly as per manufacturer’s recommendations and IS 14164 guidelines. (Make: Armacell, Armaflex, equivalent)
Ridge pieces - Profile Providing & fixing Ridge pieces - Profile, material quality conforming to item no. 540
Eaves Gutter - Profile Providing & fixing Eaves Gutter - Profile with external liner fascia as per EIC's direction, material quality conforming to item no. 540
Corner Flashing - Profile Providing & fixing Corner Flashing - Profile, material quality conforming to item no. 540
Profile Gable Flashings Providing & fixing Profile Gable Flashings, material quality conforming to item no. 540
Deep Trims Providing & fixing Deep Trims, material quality conforming to item no. 540
Polycarbonate Sheets Providing and fixing 2 mm thk. Polycarbonite sheets supplied by G.E. polycarbonate of approved profile including all quality fastenings,fixing with self tapping screws from Buildtex/Hilti, metal washers and Neoprene / EPDM washers, matching colour caps etc.complete.
Z Type Fixed Louvers Providing and fixing Galvalume Z type fixed louvers with bird screen including necessary framing and fixing arrangements.
Tubular Daylighting System Providing, supplying, and installing factory-fabricated tubular daylighting system with proper sealing and leakproof mounting system suitable for installation on PEB/metal roof structures, consisting of: UV-stabilized daylight collector dome made of polycarbonate or equivalent transparent weather-resistant material, specular reflective aluminium light transfer pipe with internal mirror-like coating having minimum reflectivity of 98% integrated with ceiling-mounted anti-glare polycarbonate diffuser for even distribution of natural daylight. FRP or metal flashing base designed to match the existing roof profile, ensuring proper sealing and leakproof installation. All required hardware including mounting brackets, insulation sleeves, silicon sealants, and weatherproof gaskets. The entire system shall comply with IGBC/GRIHA daylighting standards, and be installed as per manufacturer’s specifications, tested, and commissioned complete in all respects to the satisfaction of the EIC. Min 750 mm dia, Make: Skyshade, SVS, Solatube or equivalent
Table Providing and installation of cabin table of size 1800mm(L) X 750mm(D)X750mm(H). Table top : 25mm thick prelam thick laminated table top with Aluminum Flipup provision. Support : 25mm thick PLB gable ends and 18mm thick 450ht PLT modesty panels with necessary fixtures. Wire Management : MS Powder coated full length wire tray & vertical cable risers considerd for wire management PLB Mobile Pedestal 2D+1F. 2 Pencil drawers + 1 filing drawer. Size :400mm(W) x 450mm(D) x 650mm(H) with central locking system & Aluminum D ypte / Depress handles. Inclusive of (A) Side support storage of (Inclusice 2D ) Size: 1700mm(W) x 450mm(D) x 635mm(H ). Flipup (B)Back storage of 1800mm(W) X 450mm(D) X 750mm(H); Table top : 25mm thick E1 grade PLPB table top with Reverse Chamfer Edge on back painted on four sides with provision. Size: 500mm(W)x120mm(d) in Anodized finish only. Understructure : M.S. Powder coated/Chrome finish Conclave leg with die cast brackets and MS Powder coated beams are considered to support table top. Modesty: MS Powder coated perforated metal modesty with 450m(H)is considered. Wire management : MS Powder coated full length wire tray with switch plate and PVC wire guard are considered for wire management. SIDE/REAR STORAGE SPECIFICATIONS- Top- 25mm thick and Body made pf 18mm thk pre-laminated particle board with 400W pedestal of 2 pencil Drawers and 1 File drawers remainaing with openable shutters with Aluminium Finish C Handles+Lock and Keys.
High Back Chair Providing and supplying a high back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of commercial plywood or ABS or steel materials padded with high resilience polyurethane foam. The same shall be upholstered with pure leather. The backrest shall be made by keeping the natural curvature of the spine which helps to provide lumbar support. The chair shall be supplied with PP/ steel arm / die cast Aluminium alloy with cushion having leather / wooden covering top pivot joint with back. For seating durability the chair shall have knee tilt / synchro tilt 360 degree revolving mechanism having minimum three position locking and tilt tension adjustment with anti-shock feature which provides back strength for the chair. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to standard class gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The pedestal should have five legged made of CRCA chrome plated / Die-cast aluminium / steel with leatherite/ wooden covering top having pitch circle dia. 640mm and fitted with 5 nos. twin wheel castors.
Mid Back Chair Providing and supplying mid back chair with ergonomic design. The seat shall be made of commercial plywood / ABS materials upholstered with high resilience moulded polyurethane foam with fabric tapestry and the back shall be made of two piece injection moulded polypropylene net cover upholstered with breathable mesh tapestry. The base of the seat shall be supplied with PP cover and the backrest shall be made by keeping the natural curvature of the spine and cushion base adjustable lumbar support which helps to provide full back support. The chair shall be supplied with black integral 3D adjustable polyurethane / polypropylene arm having sliding, up-down, to & fro motion or aesthetically appealing wooden arm. For seating durability the chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-with gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The pedestal should have five legged injection moulded in glass filled nylon / steel having pitch circlewith 5 nos. twin wheel castors.
Work Station Providing, supplying and installing L Shape Workstations of size 1500(W)mm+1200mm(L) x 600/450mm (D) x 1050mm (H) Type : Desk based system (SOLE SERIES) Table top : 25mm thick E1 grade PLPB table top with matching edgebanding and Aluminum Flipup provision. Size: 500mm(W)x120mm(d) in Anodized finish only.Main spine- 18mm thick : 1350mm(W) X 300mm(H) Magnetic Board with holding brackets are considered. Brackets are anodized.Understructure: Timber Legs with die cast connectors and MS Powder coated metal metal beams are considered for support.Wire management : MS Powder coated full length wire tray & vertical cable risers considerd for wire management.Below table top-Modesty: MS powder coated modesty is considered in main spine at below table top. Leg- Modesty: MS Powder coated perforated metal modesty in main spine below table top. Make of Modular workstation complete and Low height storages to be of Make Featherlite
PLB mobile pedestal Providing, supplying and installing PLB Mobile Pedestal- 2D+1F; 2 Pencil drawers + 1 filing drawer. Size :400mm(W) x 450mm(D) x 650mm(H) with central Numeric locking system Finger grove handles with aluminium L patti.
4 Drawer Vertical Filing Cabinet 4 Drawer Vertical Filing Cabinet Specifications: Material: Prime quality CRCA steel with antirust treatmentSmooth drawer movement with precision telescopic slider mechanism Anti-rebound mechanism to prevent the drawer from coming out after it is pushed in Anti-tipping mechanism that allows only one drawer to be opened at a time to prevent toppling over of the cabinet, each door separate Locking system with key Dimension: Height (+/-10 mm): 1370 mm Width (+/-10 mm): 520 mm Depth of the cabinet (+/-10 mm): 610 mm Use: Office use Warranty: 2 years on product Certificate from Manufacturer on compliance of relevant codes & standards. Product having BIFMA certification: Yes
2 Door Steel Almirah 2 door steel Almirah Specifications: Material: Prime quality CRCA steel with antirust treatment Efficient insulation between inner and outer walls Approx. Dimensions: Width x Length x Height: 90 cm x 48 cm x198 cm 2 Doors 4 adjustable shelves. Door Type: Hinged Door Multi lever locking system with keys Fire resistant Use: office use Warranty: 2 years on product Certificate from Manufacturer on compliance of relevant codes & standards Product having BIFMA certification: Yes
Structural Steel Works Supplying, transporting, storing, straightening, cleaning, fabricating and erecting in position bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250BR (conforming to IS:2062), BSEN 10025 S275JR/ S275JO/ S355JO (for Universal Columns/ Beams) at all locations and levels, including all type of sections in all types of structural work, Miscellaneous activities wherever required, including preparation of fabrication drawings and getting reviewed from Owner/Consultant along with supply of all necessary prints including submission of AS-built drawings 2 set with soft copy in CD, all materials and labour complete as per drawings, specifications, standards and as directed by the EIC. Preparing the Surface for painting (SSPC-SP-10), Supply and apply painting as per Annexure IV to SCC after fabrication with one coat of 65 to 75 micron DFT of inorganic zinc silicate primer (FP-6), 1 coat of 170 micron Two pack Epoxy HB Aromatic amine cured (FP-3A), 1 coat of 40 micron Acrylic Polyurethene (FP-1) fixing in line or level with temporary staging, complete with all tools, equipments and labour for all depths and heights as per drawings and directed. Materials to be supplied as per approved vendor lists attached with special conditions of contract. Structure shall be erected as stic buiit/modular .
Fabricated Structural Steel Work Supply, transportation, erection, inspection, testing of Pre-Fabricated Structural Steel Elements / Structural Modules in position along with Supply and fixing of all type of Connection Bolts (Erection, Hot Dip Galvanised/ Non-Galvanised Permanent bolts) as per Specifications, Layouts and Fabrication Drawings released for IFC. Scope shall include all activities like Bolting, Welding, Aligning, making necessary alterations caused due to mismatch of Bolt Holes and / or during fabrication, Torque Tightening of Bolts, cleaning, giving final touches to the welded parts, etc as required complete in all respect. Making necessary arrangement of required labour, equipment, tools & tackles, steel scaffolding, consumables, etc to execute the works at all heights as per drawings and specifications conforming to Annexure IV to SCC and item no. 700 along with all related works in order that the Structure is handed over to the complete satisfaction of the Engineer-in-charge.
Ladder and Cage Include but not limited to Supply of Materials required to fabricate and erect the Structural Elements required for providing the Access, by way of ladders, to all types of Platforms at all Heights and Depths along with Cage Ladders and the Safety Chains (or Bars) that are provided at the Entrance of the Platforms from the Ladders. Steel material shall be as per FY=250Mpa Grade 250BR or as per specifications. Fabrication of Structural Steel Materials for ladders including arranging required labour, consumables, equipment, tools and tackles, etc., loading, unloading, intermediate handling, transportation to painting yard, collecting from painting yard and carting the same to erection site / laydown area complete in all respects. It also includes Erection of fabricated Ladders and Safety Barriers along with Supply and fixing of all type of Connection Bolts (Erection, Hot Dip Galvanised/Non-Galvanised Permanent bolts) as per Specifications, Layouts and fabrication Drawings. Scope shall include all activities like Bolting, Welding, Aligning, making necessary alterations caused due to mismatch of Bolt Holes, Torque Tightening of Bolts, cleaning, giving final touches to the welded parts, etc. as required complete with all tools, equipment and labour, for all depths and heights along with all related works in order that the Structure is handed over to the complete satisfaction of the Engineer-in-charge.
Anchor bolts upto 36 mm dia Supplying, fabricating, casting, installing and fixing in position at all levels & locations M.S.holding down threaded bolts conforming to IS 2062 Grade A or BR as per drawings and nomenclature, including supply and fixing nuts, washers, anchor plates, pipe sleeves, etc., as per Standard in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed by EIC. Supply of all material in contractor's scope.( No extra payment shall be given for template or any dummy structure) For Anchor Bolts upto 36 mm dia. E250A Grade
Grouting anchor bolts, pockets etc. Providing and grouting anchor bolts,pockets with FOSROC, CONBEX, GP2 OR equivalent.including formwork, finishing, curing at all elevation as per Annexure IV to SCC. The rate shall include all tools, tackles, labours, consumables etc.
Chequred Plate Supplying MS chequered plate (5 mm to 10 mm thickness), transporting, fabricating, fixing at various levels with help of supports cleat/stiffners on floors,platforms,stairs, including grinding edges & supplying all bolts, nuts, washers etc.,including necessary modification for supporting structure, drilling holes in plates and supporting structure including one coat of inorganic Zinc Silicate primer (Avg. 75 micron thickness), including forming cutouts in chequered plates and reinforcing edges by M.S. strips; providing toe plate of 50x6 mm height all along the edges,complete as per drawing, specifications & as directed by Engineer in Charge, but stitch welded on structures.
Square/ Rectangular Gratings Supplying, fabricating and erecting in position at all levels and locations Electroforged Gratings purchased from approved manufacturer conforming to Technical specs as mentioned in SCC in walkways, platforms, stair landing, drains, catch basins etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fabricating clamps, fixing, tack welding, preparation and submission of fabrication drawings etc. all complete as specified and directed. Painting shall be as specified and wherever required, repairs of damaged surface coat after erection, complete with all tools, equipments and labour, for all depths and heights as per drawings and as directed by Engineer-in-Charge. Inspection and checking shall be deemed considered. Floor Grating shall be Electroforged from mild steel Grade E250A IS:2062 and shall be minimum 25mm thk. Maximum size of voids shall be limited to 30x100 mm. Floor grating shall be hot dip galvanised in accordance with IS:2629 and tested as per IS:2633 and IS: 6745. Quantity of zinc coating shall be min 120 microns (900 gm/sqm) and as per specifications. Supply of all material is in contractor's scope.
Miscallaneous Gas Cutting work Miscallaneous cutting and welding works: (Not applicable for regular works as per issued drawings but applicable only for specific re-works/ modification works/ Miscellaneous works as per directions of EIC) Gas cutting in Structural beams, plates etc
Miscallaneous Welding work All activities and scope same as Sl no 770 but for welding work
Urinal Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Urinal Partition Supplying, fixing and commissioning of Compressed laminate urinal partition with 12mm thick high pressure compressed laminate panel as per IS:2046 and EN 438 all-round polished of size 450x900x12mm thick, using 2 nos SS clamps embedded in 150 x 150 PCC pocket etc. complete as directed by Client/ Engineer in charge.
Angle Valve Providing and fixing C.P. brass angle valve for basin mixer of approved quality (conforming to IS:8931 a)15 mm nominal bore Jaquar Model no. KUP-35053PN/ Roca Model no. RT5A8020CA1/ Kohler Model no. K-80154IN-4-CP/ equivalent
Floor Clean Out Supplying, fixing and testing of Floor Clean Out which are provided in floors slab as per the following specification. Material: Stainless steel. Size: 150 X 150 mm Square floor plate with push fit. Duty: Heavy duty clean out plate with screws. Marking, fixing, testing, comissioning and filling the caps around the cover. Installation: As per the approved drawing
Toilet Panel and Door Providing & fixing panel and door in Toilet of following standard dimension which includes 600mm wide door made of heat, bacteria, water, chemical, scratch, impact, anti bacterial resistant 12mm thick solid compact laminate panels.Finish of the compact laminate should be Suede/Raw Silk, which includes doors, pilasters & finished with approved texture/ shade as per the detail drawings & as per IS 2046 ( Indian Standard ) or international code. Preference will be given to Green Guard Certified product. Including all necessary hardware/ fittings and fixtures made out of Stainless steel (Grade 304) as per manufacture's specifications like Door Knob, Gravity Hinges, Thumb turn lockset indicators, Coat hooks, U- Channels, SS Shoe Box Plate, MS- Base Plate, Rubber noise deafening tape, Screws & Wall Plugs. All screws will of 304 Grade in stainless steel with satin finish. Pilasters are to be supported by MS-Base Plate. Bottom Cladding with Stainless Steel Shoe Box Plate. The base of the stainless steel shoe box will be anchored to the floor with a clearance height up to 110mm. Fixing of intermediate panels to the wall shall be stainless steel Bracket or stainless U- Channel section are fixed into wall with screw insert. Sizes as per the Architectural drawing. Finished, complete as per the specification and instruction of Engineer In Charge
Water Closet Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead,CP brass hinges and rubber buffers, CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) White(ii) Wall mounted Closet (inclusive of seat cover and fittings) Jaquar Model no. DRS-WHT-37951/ Hindware Model no. 92097 (P-21)/ Kohler Model no. K-17647IN-S-0/ equivalent
Concealed Cistern Supplying, fitting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) Concealed Cistern with Control Plate (CP) from approved manufacturer. Hindware Model no. 518237 (Concealed Cistern)/ Hindware Concealo Neo (Aura) (Flush Plate)/ Roca Model no. RE890010100 (Concealed Cistern)/ Roca Model no. RE890195000 (Flush plate)/ Kohler Model no. K-77029IN-M-NA (Concealed Cistern)/ Kohler Model no. K-4177IN-M-CP (Flush plate)/ equivalent
Health Faucet Providing and fixing Jaquar make Health Faucet (Jaquar Catalogue Reference ALD-573) or any other approved equivalent all complete as per drawings, specifications and as directed by Engineer-in-charge.
Flush Cock Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified.(G.I. & C.P pipes shall be included)Flush cock with wall flange 25mm with plain knob.
Toilet Paper Holder Providing and fixing Jaguar make Toilet Paper Holder (Jaguar Catalogue Reference AHS-1551) or any other approved equivalent all complete as per drawings, specifications and as directed by Engineer-in-charge.
Soap Holder Providing, fitting and fixing CP soap tray/ soap dish of approved manufacturer complete as directed and specified. Jaquar Model no. AKP-35731/ Hindware Model no. F840006/ Kohler Model no. K-17524T-CP
Two Way Bib Cock Supply & intallation of Premium grade matching SS/CP/Brushed steel finish on brass 2 way bibcock faucet with spout head and flange for hygiene spray complete with screws, plugs, rossette etc, wall mounted.
Robe Hook Supply & intallationof SS/CP/Brushed steel finish on brass double robe hook. Wall mounted, any of the below make & model or equivalent ROCA: RA816651001/ KOHLER:25073IN-C
Under Counter Wash Basin Supply & intallation of Under counter white ceramic wash basin length & breadth will depend as per site execute to sit completely below the vanity counter; of any of the below make & model: ROCA:RS327871461/ KOHLER:2211IN-0/ American Standard CL0474I-6DACTLU/ VITRA:Cat No 6069B003H0012/ equivalent. Inclusive of installation if any cutout or holes needed, after completing it have to concealed the cutout and holes with cement / mortar/ plaster no extra money will be paid.
Kitchen Sink with Drain Board Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Granite Counter Providing, constructing Granite platform as per Architectural drawing: out of a) 18 mm thick 600 mm wide mirror polished approved Granite stone exposed faces / edges rounded and mirror polished. (Top of the counter) b) 18 mm thick 75 mm wide granite fascia exposed edges mirror polished and moulded as detailed, c) 18mm thick 50mm high approved Granite stone back splash exposed edges mirror polished and moulded as detailed. Granite stones shall be anchored and grouted with stainless steel pins, clamps and anchor fasteners into concrete and wall, Granite stone at bed shall be bedded in cement sand mortar (1:4) with required cement punning. fascia shall be fixed with epoxy resin work shall include require drilling of hole, makingnotches, grooves, grouting with epoxy and cement finishing, curing all complete asper detail drawing of Architect and as per instruction from PM from time to time.Further work shall include required cutting in granite to receive stainless steel sinkpolishing of cut edges to the approval of PM. All joints with masonry stone work and stainless steel sink shall be sealed with silicon sealant. Basic Rate- 250/Sqft)
Basin Faucet Supply and installtion of Deck mounted single lever faucet with SS/CP/Brushed steel finish on brass, with aerator, for cold water only. Of any of the below make & model: 1. TOTO: TTLR102/ VITRA:A41590IND/ ROCA: RT5A4220CA1/ KOHLER:20747IN-8-CP/ equivalent
Soap Dispenser Supply & intallation of Decorative glass body manual push down pump action liquid soap dispenser with CP trimmings, with screws, plugs, rossette etc for wall mount complete.
Towel Ring CP on brass towel ring corresponding to 200 mm dia with wall mount with screws, plugs and rossettecomplete ; of any of the below make & model or equivalent- TOTO:YTT406C/ American Standard FFAS6590-908500BF0/ VITRA: A44943/ ROCA:RA8166590015/ KOHLER:25067IN-CP
Concealed Stop Cock Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (ii) Concealed stop cock with adjustable wall flange. Jaquar Model no. ALD-083 (concealed part), KUP-CHR-35083KPM (exposed part)/ Roca Model no. RT5A1520CA1/ Hindware Model no. F850096 (concealed part), F520007 (exposed part)/ equivalent
Mirror Supplying fitting and fixing 6mm thick side bevelled mirror backed with 6 mm thick water proof ply fixed with necessary adhesive with the mirror. The edges of the glass should be extended by 5 mm beyond the ply board in all directions. Cutting necessary holes for screw to fix the mirror with wall / tile surfaces with ss screw having 12 mm or more dia screw concealed head. Finished and complete as per instruction of Engineer- in charge.
Waste Coupling (FT) Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.(i) Waste coupling (full thread) 32 mm. Jaquar Model no. ALD-705L130/ Hindware Model no. F850002/ Kohler Model no. K-45432IN-CP/ equivalent
CPVC Pipes 20 mm Dia Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
CPVC Pipes 25 mm Dia All activities and scope same as above but for 25 mm dia pipes
CPVC Pipes 32 mm Dia All activities and scope same as above but for 32 mm dia pipes
CPVC Pipes 40 mm Dia Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40 mm nominal dia Pipes
CPVC Pipes 50 mm Dia All activities and scope same as above but for 50 mm dia pipes
GI Pipe Sleeve Supplying, fabricating and fixing in position GI Pipe Sleeves of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding In position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. GALVANIZED IRON (G.I.) PIPES (HEAVY)
C I Cover Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg
RCC-M15 Reinforced Cement Concrete of M-15 grade in compound walls, posts, pillars all cast in situ as per drawing and relevant technical specifications covered under various sections, including shuttering, finishing, curing etc. but excluding reinforcement.
Supply and fixing MS structures Supplying, fabricating and fixing in position M S flats, angles, channels, M.S.tubes, bars etc. as per IS 2062, for fixing of Chain link jali/mesh including welding, drilling holes, nuts, bolts, washer, and including providing & applying two coats of epoxy paint over one coat of epoxy primer. All complete as per drawing. (All the materials shall be procured by the contractor and included in their quoted rate. No separate weights shall be considered for payment on account of bolts, nuts and washers, which are deemed to be included in quoted rate by the contractor).
Concertina Wire Fencing Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
2100 mm GI chain link Providing and fixing chain link fencing, including excavation, disposal of surplus earth, form-works, concrete blocks, back-filling etc, supplying and installing 50 mm x 50mm x 8 gauge mesh welded to 50mm dia G.I. pipe frame work and fixing to structural steel posts or walls, painting with two coats of anti-corrosive paint and two coats of approved aluminum synthetic paint etc., all complete as per standard drawings/specifications with all tools, labour etc and as per directed.
Granular Sub Base Construction of granular sub-base for drainage layer spreading 150mm THK. for road/paving portion , tough, sound, clean and durable including cost of stone aggregate all royalties, taxes, handling, transportation to site, stacking the same by the side of road with all leads and lifts, spreading and laying to form draingae layer 150 mm compacted thickness to proper grade, camber and level,compacting with 8 to 10T vibratory road roller, watering including the required test involved, complete as per drawing, specifications, and directions of Engineer-in-Charge.
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control
Water Bound Macadam Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density including subgrade compaction,minimum soaked CBR 5% measured as per IS:2720-31. 98% of OPM on at least 500 mm thickness (optimum proctor is per IS:2720-7). Grading 1 (90 to 45mm) Using crushable screening such as moorum gravel for Gr.I. By mechanical means. The item is inclusive of all leads and lifts for carriage of the aggregates
Paver Block Providing and laying concrete interlocking colored paver blocks 80 mm thick. Paver Blocks shall be minimum M40 grade and shall conform to IS 15658:2006. Sampling and Testing Procedure strictly As Per IS 15658:2006. Laying and Laying Patterns shall be as per IRC SP-63. All other visual/ physical & dimensional acceptance on parameters like aspect ratio, squareness etc to be as per IS-15658:2006. with sand bedding, base layer of PCC/ WBM/ WMM/ Crushed Rock/ Soil-Cement including subgrade compaction, leveling and vibrating after laying of blocks, brooming extra sand, including edge protection, etc. all complete as per specifications, sketch/ drawings and as directed by Engineer-in-charge.
Type I Pavement Providing and laying Reinforced Concrete for Paving & Paving supported pedestals any Shape/ Location/ slope/ Type/ Thickness for specified concrete grade (Ready Mix Concrete with design mixes) with 20mm and down size graded crushed stone Aggregates / Gravel, using Ordinary Portland Cement/Portland Pozzolona Cement, including all earthworks in filling/ excavation as necessary, sub-grade compaction with base-course laid in layers if required by relevant specifications or drawings, casting of reinforced concrete slab in alternate panels, formation of required slopes, leaving pockets, if necessary, making recess/ drains, kerbs, shuttering, tamping, curing all inclusive.finishing the top surface smooth, Providing the Drains for Floors, etc. all complete including the Supply and Laying of Admixtures and corrosion inhibitors as per drawings, specifications and directions of Engineer- in-charge. For concrete refer specification for Plain and Reinforced concrete. All materials including cement to be supplied by contractor. Reinforcement shall be paid separately. For type-I pavement (Upto and inclusive of thickness of 200 mm). (Including providing and laying MS dowel bar, painting as required, GI pipe and cap and cotton waste). Concrete grade : M30
300 mm dia NP3 RCC Hume pipe Providing , Laying and jointing of RCC hume pipe of NP3 class with socket and spigot ends conforming to IS:458 of approved make, to proper grade slopes and alignment, including earthwork in excavation in all types of soil except soft and hard rock for pipe trenches, pits, manholes etc. including dewatering of surface / sub surface water as required to facilitate lowering of pipes, taking all safety precautions, supporting existing U/G services, shoring and shuttering if necessary, dressing of sides, levelling, grading and ramming of bottoms, cutting the R.C.C. pipes to required lengths, lowering the pipes, jointing including connecting the pipes to manholes and grouting the pipes body with manhole wall using cement mortar 1 : 2 (1Cement:2Sand), testing, draining of water and cleaning of pipes after testing, PCC bed, sand cushion and haunch concrete, backfilling the trenches with serviceable available earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15 Cms., watering, rolling and ramming by manual methods / mechanical compactors
Vegetal Soil Surface Installation Surface landscaping including mixing of Manure with soil for creation of green area in presence of obstacles or restrictions like foundations, kerbs etc if any, both in flat or sloped areas, including laying the soil in specified thickness and/or IFC drawings, all complete. Supply of all materials, labour and tools and tackles required to complete the job in all respects is in the scope of contractor.
Painting on Roads Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/ concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification including all required mateial, tools, manpower etc.
Wodyetia Bifurcata Palm Tree Supply of Wodyetia bifurcata palm tree of minimum 3000 mm clear trunk and height 4500 centre to centre
Flowering Shrubs Supply of aesthetically appealing flowering shrubs that matches the surroundings and uplifts the beauty of the front facia of the building
Hedge Supply of hedges that reflects the character of the surrounding landscape and matches with the vegetation thereof.
Retro-Reflectrorised Sign Providing and erecting direction and place identification retro-Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area exceeding 0.9 sqm fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm, 2 nos. firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Rack System Design, Supply, delivery, and installation of Racking system of make- Godrej Altius Titan/ Equivalent Multitier Shelving System, suitable for warehouse application. The system is designed for high-density storage with integrated plain catwalk walkways, offering clear and organized material handling on Ground Floor. Successful bidder to submit detail design and orientation plans to EIC for approval. System Configuration: The rack system to be designed in such a way that maximum space is utilised with a standard circulation space. Total Units: Maximum units possible within the warehouse space. Per Warehouse size is approx. 1000 sqm. Load Capacity of the shelves of following capacities to be considered while designing the rack system - Type A- 500Kg UDL per level Type B-1000 kg UDL (Uniformly Distributed Load) on 1st & 2nd Tier – (500 Kg UDL will be accessed by single side) Catwalk Type: Plain Walkway Panels Catwalk Load: 300 Kg UDL per sq.m. Decking Panels: Min. 6-bend galvanized decking panels Mesh Cladding: Provided on back side of Type A units only Component Finish: Uprights & Base Plates: Sky Blue Beams: Deep Orange Bracings: Galvanized Decking Panels: Galvanized
Electrical Works
VTPN DB Supplying and fixing of following ways surface/ recess mounting, Vertical Type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and MCCB incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) Same specification for this and similar category of items below. Outgoing feeders ratings to be mentioned clearly to avoid confusion during bidding stage by bidders. 8 way (4 + 24), Double door
250A 4P MCCB Providing and fixing following rating and breaking capacity and pole MCCB with microprocessor based release with OC/EF/SC protection and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Same specification for this and similar category of items below. 250 A,36KA,4P MCCB. MCCB terminals shall be adequate enough to terminate minimum 1Rx 4Cx300 sq.mm Al armoured cable.
High Bay LED S & F of LED Light Fitting Ceiling mounting type, non-integral , high bay luminaries,with Optical lens with silicon loop, High quality SMD LED with MCPCB for uniform light distribution, comprises High pressure aluminium die cast housing for better heat dissipation & Separate LED driver box with extra cooling fins including 150W LED Lamp,(Make:SYSKA- LED UFO HI-BAY 150W 150lm/W)) or its equivalent in Phillips,havels, CG etc., including Suspension clamp, ring etc.
600X600 mm LED Light Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories of Recess mounted LED Panel Light (600mmX600mm) 30 W (Max), 3400 lumens(minimum) with white powder coated CRCA housing with Translucence diffuser,IP-20, CCT/CRI-4000K/80, .Electronic Balast similar to Wipro make-Elate or its equivalent item of Philips/ Abby Lighting/ Jaquar Lighting /Havels/Crompton/Syska as per tender specification & clients/EIC approval.
18W LED Down Light Supply, Installation and commissioning of18W LED Decorative Down lighting fixture
60W LED Street Light Supply, Installation, Testing & Commissioning of 60 W LED with complete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture, Mounting brackets, fastners etc. as required. Havell's Cat no: ENDURAPEARLPLUSSL60WLED757SASYTOPC or Equivalent.
20W LED Emergency Light Supply, Installation and commissioning of 20W LED Emergency lighting fixture with Battery back-up.
200W LED Flood Light With Pole Supply, Installation and commissioning of 200W LED Flood lighting fixture with 5m lighting pole
18Watt 4feet Batten Light Fixtures Supply ,Installation ,Testing and commissioning of 18W,6000K decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient equivalent to HAVELLS Ordering codeLHEXBTP7UN1W018, Make : Havells/Bajaj/Philips/Jaguar or equivalent as per the direction of EIC
Ceiling Fans Supplying including fitting and fixing of start rated ceiling Fan complete with all accesories like Down Rod, Canopy etc of following sweep with making necessary connection cable as approved by Client and as required and directed. -ECBC 1.1.2- Energy Efficient 5 Star 1200mm sweep fusion (Havells or equivalent make)
Industrial Pedestal Fans Industrial type Pedestal fan <Air circulator> having following specifications : Input: 1 ph, 230Vac+/-10%, 50Hz, Motor Insulation: Class- B/F Bearing: Permanently lubricated double sealed bearing with expected life of not less than 40,000 hours RPM:1500 Nos. of of Blade: 3 Protection: IP-65 Temperature Range : -40 to 50deg C Conforming to IS: 1169 Painting: Anti corrosive enamel paint Motor having Copper Winding : Yes Make: Orient/ Bajaj/ CGL/Usha/Equivalent
Wall fans Supplying including fitting fixing of following A.C. Wall fan V2 with metal blade, 450 mm sweep in the wall of following with making necessary connection as approved by the Client.)as required complete and as directed by the Client.(Make: Crompton/Orient/Havels/Usha)
Fan regulators Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
4 Way Junction Box. Supply, Installation of Industrial Lighting Junction Box 4 way for loop-in loop-out purpose with terminals suitable for 2.5/4 sq. mm and blind plugs as applicable for outdoor apllication.
12Way TPN LDB Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V,Double Door TPN MCB distribution board of sheet steel, dust protected, duly powdercoated, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, dinchannel for mounting MCBs as required .12-Way LDB
12Way TPN PDB Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V,Double Door TPN MCB distribution board of sheet steel, dust protected, duly powdercoated, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, dinchannel for mounting MCBs as required .12-Way PDB
Single pole MCB Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA ""C"" curve,SP miniature circuit breaker(MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole"
63A 4 P MCB Supplying and fixing 240/415 volts, ""C"" curve, miniature circuit breaker of following rating suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A,10KA 4P MCB
63A 3P MCB Supplying and fixing 240/415 volts, ""C"" curve, miniature circuit breaker of following rating suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 3 P MCB
3pin Socket with SPMCB Supply Installation and commissioning of 20A, 240V, single phase, 3 pin socket outlet with 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure.
3pin Socket with 1 HP motor Starter Supply Installation and commissioning of 20A, 240V, single phase, 3 pin socket outlet with 1 No. 4HP motor starter, in sheet steel enclosure.
Switch socket 3M Supply and installation of Decorative type switch socket back box with 1 no. 5/15A switch socket unit and 1 no. modular piano type switch
Switch socket 4M Supply and installation of Decorative type switch socket back box with 1 no. 5/15A switch socket unit and 2 no. modular piano type switch
Switch socket 5M Supply and installation of Decorative type switch socket back box with 1 no. 5/15A switch socket unit and 3 no. modular piano type switch
Switch socket 6M Supply and installation of Decorative type switch socket back box with 2 no. 5/15A switch socket unit and 2 no. modular piano type switch
Switch socket 4M Supply and installation of Decorative type switch socket back box with 1 no. 5/15A switch socket unit, 1 no. modular piano type switch and 1 no. piano type 2way switch
Switch socket 4M Supply and installation of Decorative type switch socket back box with 1 no. 20A switch socket unit, and 1 no. 4HP motor starter
3 phase Industrial type Socket Supply, installation & commissioning of of Industrial type, 415V, 63A, TPN & E socket outlet, with die cast Al LM6 enclosure with cable loop-in loop-out facility. The rate is inclusive of required TPN MCB etc. as required.
Pedestal Fan Supply, installation & commissioning of Pedestal Fan (400mm) with electronic speed regulator etc. as required with all fitings to complete etc.
Exhaust Fan 300mm Supply, installation & commissioning of heavy duty Exhaust Fan (300mm sweep)
Exhaust Fan 150mm Supply, installation & commissioning of Exhaust Fan (150mm sweep)
Wiring with 2.5sq.mm Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire The rates are inclusive of Conduits, saddles, screws, wires bends etc. as required complete.
Wiring with 4 sq.mm Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. The rates are inclusive of Conduits, saddles, screws, wires bends etc. as required complete.
Point wiring Group B Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Point wiring Group B
PVC Trunking 105X50mm Supply, installation, testing and commissioning of cable trunking system above and below working plane to distribute Power, Data and Telecom cables. The system shall comply with all relevant sections of the 16th edition of IEE wiring regulations and shall be CAT 6A compliant. Cable trunking shall comprise of base & lid with snap-fit lid and allied accessories such as Separate partition, Plastic Chip on Partition, body joint for base, cover joint internal angles, external angels, cable dividers, , angles, end caps, junctions, clips etc. complete as required as per direction of EIC. end caps, angles, flat junctions etc. System shall be non-corrosive and shall have excellent resistance to mineral acids, alkalis and detergents.Material used is non flame propagating."" 105x50mm Single Compartment
Supply of 3CX2.5 sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required. 3Cx2.5 mm2 2XWY copper (for Lighting other misc. power)
Supply of 3CX4 sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required 3Cx4 mm2 2XWY copper(for sockets, and other misc. power)
Supply of 4CX4 sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required 4Cx4 2XWY Copper
Supply of 4CX16 sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required 4Cx16 2XFY Copper (for SLDB, Lighting mast and other misc. power)
Supply of 3.5CX50 sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required 3.5Cx50 A2XFY Aluminium(for PDB, 63A socket outlets and other misc. power)
Supply of 3.5CX120sq.mm Supply, of following 1.1 KV grade XPLE insulated, PVC sheathed, and armoured FRLS cable in ground/pipe complete as required 3.5Cx120 A2XFY Alluminium(for incoming power)
Laying of 3CX2.5 sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on wall surface/Cable trays etc. as requiredwith 1mm thick shaddle/ screws etc. 3CX2.5Sq. mm
Laying of 3CX4 sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on wall surface/Cable trays etc. as requiredwith 1mm thick shaddle/ screws etc. 3CX4 Sq. mm
Laying of 4CX4 sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on wall surface/Cable trays etc. as requiredwith 1mm thick shaddle/ screws etc. 4CX4 Sq. mm
Laying of 4CX16 sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on Ground including excavation, sand cuoshing, protective covering, refilling the trench etc. as required . 4CX16 Sq. mm
Laying of 3.5CX50 sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on Ground etc. as required . 3.5CX50 Sq. mm
Laying of 3.5CX120sq.mm Laying of one number XLPE insulated, armoured and PVC sheathed multicore power cable of 1.1 KV grade of following size on Ground including excavation, sand cuoshing, protective covering, refilling the trench etc. as required . 3.5CX120 Sq. mm
LT cable laying OD upto 40 mm Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground as per direction of EIC. Cable laying OD upto 40 mm
LT cable laying OD above 40 mm Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground as per direction of EIC. Cable laying OD above 40 mm
End Termination 3CX2.5Sq.mm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3Cx2.5 mm2 2XWY (for Lighting other misc. power)
End Termination 3CX4 Sq.mm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3Cx4 mm2 2XWY (for sockets, other misc. power)
End Termination 4CX4 Sq.mm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4Cx4 2XWY
End Termination 4CX16 Sq.mm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4Cx16 2XFY (for SLDB, Lighting mast and other misc. power)
End Termination 3.5CX50 Sq.mm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5Cx50 A2XFY (for PDB, 63A socket outlets and other misc. power)
End Termination 3.5CX185 Sq.mm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5Cx185 A2XFY (for incoming power)
Supply of Cable tray 300mm Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. Same specification for this and similar category of items below. 300mm widthX 50mm depthX 1.6mmThickness
Supply of Cable tray 100mm Supply of 100 mm wide perforated straight run GI cable tray complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection),accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade) size: 100mm widthX 50mm depthX 1.6mmThickness
Inst. Of Cable tray 300mm "Installation of 300 mm Width Ladder Type GI Cable Tray Straight Element.300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection),accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)"
Inst. Of Cable tray 100mm Installation of 100 mm Width perforated Type GI Cable Tray Straight Element complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection),accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
GI 65mm Dia pipe Earth Pits Supplying, providing and constructing GI Pipe Earth electrodes as Per IS:3043; GI Pipe Medium Class 'B' 65 mm Dia; 3 m long complete with Earth Pit and all necessary materials including excavation of Earth Pit, filling with homogeneous layer of Charcoal and salt, Back filling, providing necessary Brick Masonry work, Plastering, MS/CI cover; Test links for connecting the earth Grid and Earth Electrode. This also includes testing of Earth resistance after completion as per Indian Electricity Rules. Minimum depth of burial shall be 3 m, homogenous hygroscopic material should not be less than 1 cum.& should cover 300 mm around the electrode up to a height of 2500 mm. The scope of work also includes providing earth pit markers indicating resistance, test date, next due date etc.
75x12 mm GI Strip Earthing conductors to be supplied and suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to structure / equipment foundations, racks, walls, roofs, trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface. The contractor shall supply the required materials to complete the earthing installation, the material such as welding of earthing conductor joints, GI clamps, GI fastners, Lugs at earth plate & at equipment end wherever required, supply & applying of bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints and necessary hardware for connecting, etc., 75 X 12 MM Hot Dip Galvanised GI Flat
Earth Bus Supply and installation of Earth Bus with required 10mm dia holes and Gi nuts/ bolts etc.
Lightning Arrestor LIGHTNING PROTECTION AS PER IEC 62305 / IS IEC 62305 AT LVL -IV (20X20 MTR ) EARTHING AS PER IEC 62561- 2 & 7 Supply and installation of Vertical copper Lighting Arrester of 16MM dia, 1000 mm long with Gun Metal base plate and required accesotries. This lightning rod shall be connected with main lightning grid/pit including supply of fixing fastners/ material.
7 digit strike counter Supply and installation of 7 digit lightning strike counter.
25X6 mm GI Strip Supply and laying of 25 x 6mm GI Strip for lightning on roof / down conductor/ ground etc, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Test Link Supply and Installation of Test link with required materials for completion.
8SWG dia GI Wire. Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Steel for supports Supply, Fabrication, erection ,cleaning, painting and Installation of supporting steel for trays, light fittings, JB, SLDB, Socket and miscellaneous works etc. All consumables such as welding electrodes is in the scope of the vendor.
High Mast Supply, Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire , testing and commissioning of lighting luminaires and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. Following Site Conditions will be considered for design and installation of 30 meter heigh High Mast : ● Maximum Ambient temperature : 38 Deg C ● Minimum Ambient temperature : 5 Deg C ● Equipment design temperature : 40 Deg C ● Earthquake Design factor : (Code IS-1893 Zone-V/Site spectra whichever is governing), As per IS 1893,Seismic factor = 0.36 ● Wind speed : 50 meter / sec ● Site Altitude : 90 m above MSL ● Relative humidity : 85% at 3 Deg C ● Environmental conditions : Corrosive Industrial Environment / Extreme Moisture (Tropical Climate) The High Mast shall be comply the flowing codes and standards as minimum, but not limited to the following : ●. PLG 7 High Masts for Lighting and CCTV ●. SANS 10225:2012 High Mast natural frequency calculation ●. IS 875 Part – 3 Wind Loading ●. IS 2062/ BS EN 10025 High Tensile Steel Sheets ●. IS 2062 Mild Steel ●. BS EN ISO 1461 Galvanization ●. IS 3459 / 2266 Stainless steel Wire rope ●. IS 9968 Part – 1 Trailing Cable ●. IS 12615 Motor ●. IP66, IK08, wind tunnel test on a specimen to establish the force coefficients of the 20-side polygon and the value received from the wind tunnel test is to be taken in design, The winches are to be type tested through reputed institutions like IIT as consultants. 30 Meter High Mast with 12x400W LED Lighting fixtures comprising of the following as a minimum : ● 30 Meter High Mast shaft in three sections suitable for required wind speed with raising / lowering system comprising of frame for luminaries carriage suitable to install 12 nos luminaries in symmetrical arrangement, SS Wire rope, trailing cable, motor, manual handle, junction box, lightning protections including lighting finile and all other accessories required for the complete installation of the High Mast. ● MS anchor Foundation bolts as per Civil drawing no : TP-1ZZZA-CV-COD-0007.01 along with nuts, washers, anchor plates and templates ● Non-integral flood light luminaries of 400W LED Fixtures with control gear boxes ● Two nos. aviation obstruction lights with 9W LED Lamps ● Outdoor stand mounted flameproof MCB DB/ flameproof Feeder pillar distribution box with Incomer / outgoing MCB, ELCB, timers suitable for Zone 2 gas group IIA/IIB, Temp. Class T3. ● Trailing cables, wires as required (except the incoming power cables to Feeder Pillar Box / MCB Distribution Box). ● Supply shall include commissioning spares as required (List shall be provided by bidder)
Supply of1.5 T AC Supply 1.5 T split AC with all accessories along with the copper pipe , communication cable between indoor and outdoor upto 3 mtr with insulation. Detail technical specification are as follows for split AC: 1. Technology of AC : Inverter AC (Variable Speed) 2. Refrigerant Type :R32 3. Refrigerant Global warming potential (GWP) :675 (For R32) 4. Refrigerant Ozone Depletion Potential is Zero :Yes 5. Heating :Cool Only 6. Coil Material (Evaporator) :Copper 7. Coil Material (Condenser) :Copper 9. With 7 stage air treatment and nano tech. coating for evaporating tube. 8. Compressor Warranty ( A ) :5.0 9. BEE Star Rating (Central Ministries:: Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star(where usage is Limited)or higher Star Rating of BEE) :5 10. Nominal cooling capacity(Ton) (1 ton = 3000 kcal::Hr) (+::-10%) :1.5 Ton 11. Conformity to Indian Standard: As per IS 1391(latest) Part 2 for Room Air Conditioners. 12. Availability of BIS Certification : Yes 13. Green Room Air Conditioner Compliant: 14. Company Certification : ISO 14001 15. Technical Parameters 16. Technology of AC: Inverter AC(Variable Speed) 17. Nominal cooling capacity(Ton) (1 ton = 3000 kcal/hr) (+/-10%): 1.5 Ton 18. Energy Performance Threshold (ISEER)(Wh/Wh) (for Greenroom AC): >/= ISEER 5.4 19. Refrigerant Type : R32 20. Coil Material (Evaporator) : Copper 21. Coil Material (Condenser) : Copper 22. Input Power Supply : 230V ac, 50Hz 23. Connecting pipe length (meter): 3 metre 24. Material of Air Filter : Synthetic fibre 25. Reusable Air filter: Yes 26. Noise level: As per latest IS 1391 27. Environmental Friendly Paint: Yes 28. AC Modes: Turbo Mode, Dehumidification mode, Power Saving Mode, Auto Clean Mode, Self Diagnosis Mode, Quiet Mode, Dry Mode, Eco saving, Anti Mildew 29. Remote Control Features*: Timer, Child Lock, Night Glow Buttons 30. Mandatory Marking: Manufacturers name, model, size, type, name and quantity of refrigerant, rated voltage, phase, rated frequency, nominal cooling capacity, power consumption at rated conditions, nominal current at rated conditions. 31. Accessories inclusive in the scope of supply: Installation kit, 2 nos of remote cell, manual and remote. 32. Warranty/Services : AC machine warranty: 1 Year Compressor warranty: 5 years 33. Installation: Standard Installation. Stand for outdoor unit to be supplied by the bidder at the time of supply of the ACs. 34. Availability Of Test Report From Central Govt/Nabl/ Ilac Accredited Lab To Prove Conformity To Specification : Yes 35. Copies of reports and certifications to be furnished to buyer on demand at time of supplies : Yes
ITC Of 1.5 Ton Ac ITC of 1.5T split AC
SITC of AC bracket Supply And installation of AC stand/ bracket as required.
SITC of Copper pipe S&I of Copper pipe
RCCB 25A Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Same specification for this and similar category of items below. 25A
SITC of 600MM Turbo Ventilators Supply nad Installation of : 600 MM Turbo Ventilators for warehouse with polycarbonate base plate min 2 mm thickness
2000 CFM exhaust fans Supply installation and commissioning of heavy duty industrial type Exhaust fans for Warehouse : 2000 CFM exhaust fan.
50 pair armoured telephone cable Supply of TELEPHONE CABLE (ARMOURED) 0.5 mm / 50 Pair (armoured) PIJFPIJF U/G Phone Cable
20 pair armoured telephone cable Supply of Telephone cables 20P x 0.5mm armoured cable
5 pair unarmoured telephone cable Supply of Telephone Cable (Unarmoured) 0.5mm/5pair(Unarmoured) Singlerun PVC insulated telephone cable, ISI approved. Make: DELTON, NETCO or Equivalent
100 pair Telephoen JB Supply and installation of 100 Pair halogen free and weather proof telephone junction box confirming to IP66 for outdoor installation and with metric knockouts for cable entry with 100 numbers of connecting modules(Krone) on back mounting frames(One connecting module have 10 slots for termination) in each JB's for termination of 0.5mm telephone cables and with all other accessories required for installation of the JBs and as per the direction of the Engineer-in-Charge.Make: Hensel or equivalent
50 Pair telephone JB Supply and installation of 50 Pair halogen free and weather proof telephone cable junction box confirming to IP66 for outdoor installation and with metric knockouts for cable entry with 5 numbers of connecting modules(Krone) on back mounting frames in all JB's for termination of 0.5mm telephone cables alongwith 6 nos of polyamide glands and with all other accessories required for installation of the JBs and as per the direction of the Engineer-in-Charge. Make: Hensel or equivalent
Cable glands 50 P Supply and installation of threaded cable glands for outdoor installation confrming to IP 65 of polyamide with lock nut suitable for termination of 50 pair telephone cable and as per direction of Engineer-in-Charge.Make: Hensel or Equivalent
PVC Mounting Box Supply and installation of PVC surface mounting box with 2 module,cover plate and double RJ11 telephone socket with shutter and with supply of all accessories required for installation of the boxes and as per direction of Engineer-in-Charge.Make: Legrand or Equivalent
Analog telephones Supply, Installation , Testing and commissioning of Push button Telephone handet with 3 step ringer volume, mute, pause & redial complete with connecting cords & jacks as required.
Caller ID telephones Supply, Installation , Testing and commissioning of Telephone handset with 24 keys 3 line display, Confrenece calls, Handsfree, Redial Memory, flash, mute, pause tone & pulse dialing redialing Desk/Wall mountable ringer indicator LED/CLI (with display) complete with connecting cords & jacks as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_920187.xls
BOQ • 0.52 MB
Tender.rar
RAR • 13.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .